h1sush7 timing glitch, models restarted

Sheila, Camilla, Jim, EJ, Dave:

At 16:29:25 we had a timing glitch on h1iopsush7 which stopped it from running. 

Sheila and Camilla checked the SDF settings for h1susfc1 and h1sussqzin models before the restarts.

I verified all the IO Chassis cards were present and correct, and then restarted all the models.

I untripped the HAM7 SWWD, but accidentally also untripped HAM1. I returned HAM1 back to PM1 bypassed, SEI-HAM1 tripped.