erik.vonreis@LIGO.ORG - posted 12:13, Thursday 19 February 2026 - last comment - 07:36, Friday 20 February 2026(89196)
h1ascimc restarted and DAQ restarted

DAQ was restarted around 12:02 PM  PST after restarting h1ascimc. 

Comments related to this report
david.barker@LIGO.ORG - 07:36, Friday 20 February 2026 (89208)

There were some issues with the new code, so we reverted h1ascimc back to its original code at 13:40. We will try again next week.

When h1ascimc was restarted by itself, h1iopasc0 ran long and reported a DAC error, though on the 16bit-DAC MEDM there were no associated FIFO errors reported.

When h1ascimc was started as part of a complete model restart (rtcds start --all) this DAC error does not appear.

The DAC error is clearable by DIAG-RESET'ing the IOP, but we are unsure if the DAC is a cycle behind at this point. At the moment the safest restart if DAC errors appear is a full restart of all models.