Reports until 16:42, Thursday 19 February 2026
H1 SUS (CDS)
oli.patane@LIGO.ORG - posted 16:42, Thursday 19 February 2026 (89198)
PM1, RM1, RM2, JM1, JM3 COILOUT/DAMP filters updated to solve our confusion

Rahul, Jeff, Oli

In December 2025 when we needed to compensate for the HAM1 DACs moving from 16- to 28-bit, we had decided to have FM10 in the COILOUTF bank be gain(1024), and put the remaining gain(4) upstream in multiple other places (88553). This led to our confusion today when we realized that when taking transfer functions for PM1 and JM3, the TEST banks had gone back to gains of 1 a couple weeks ago, and since we had damping off, the extra gain wasn't going through to the excitation. This might at least partially be why PM1 had dropped in magnitude, and why the JMs are so low in magnitude too.

To solve confusion, I've gone through PM1, RM1, RM2, JM1, and JM3 and removed the extra gain(4) that's in:
- DAMP bank FM4
- TEST bank gains (if still there)
- OPTICALIGN gains
- LOCK filter bank gains
Then I updated the gains in COILOUTF FM10 from gain(1024) to gain(4096).

I've sdf'd the values and loaded in the changed filter modules. I also committed the filter file.

*To remove future confusion about the difference in value of the "28BitDAC" filter module in COILOUTF FM10, I am going to go through all the suspensions and change the name of that filter from "28BitDAC" to be something like "16to28Bit" or "18to28Bit" depending on the previously used DAC bits