Reports until 16:57, Monday 09 March 2026
H1 General (ISC)
camilla.compton@LIGO.ORG - posted 16:57, Monday 09 March 2026 - last comment - 11:06, Tuesday 10 March 2026(89438)
Locking Notes - Monday 9th March - IMC now locks

Sheila, Ryan C, Ryan S, Marc, Daniel, Oli, Control Room...

During the morning, Sheila and Ryan struggled again with the IMC locking. Lots of trending and adjusting gains and signs. The IMC OLG looked noisy and the IMC could stay locked for ~1minute without SUS feedback but not with feedback. The MC1 DAC card was swapped 89426, 89427 and new transfer functions showed this was better than Friday 89435,  however IMC still wouldn't stay locked. Daniel, Ryan and Sheila then realized that MC2 M2 was not actuating and Marc and Oli tracked this down to a loose cable 8943489436. Oli opened FRS ticket: 37180.

After this was fixed, Sheila started editing the guardian to remove temporary fixes and remeasured the IMC OLG, see attached. This now looks good, 38.5kHz UGF is with 2W into the IMC, gain 5, one common boost on, which is as old guardian would have set it, except M1 feedback is still off. This was compared to 89046 Feb measurements. IM4 trans is 1.2W which is a little lower than before the JAC install. 

After the VAC team decoupled the AUX carts by HAM1/2, Jim unlocked the HAM2 HEPI. 

Ryan C locked the green arms using INTIAL_ALIGNMENT_OFFLOAD as Jenne reset those references last week 89385.

After HAM2 was unlocked, we struggled to turn on the MC2 M2 feedback, however the IMC was surprisingly stable with only the M3 and laser feedback, Sheila took IMC-MCL crossovers. It's a strange loop as M2 isn't really doing anything so Sheila tried copying the PRCL M2 filters over to actuate via M1, this didn't work. 

Sheila turned on the IMC WFS, this worked well and brought IMC_TRANS from 180 to 200. Then they were offloaded using the guardian (not the smoothest offloading). After the WFS were offloaded, we reset the guardian to include both M1 and M2 feedback and it worked.

The IMC-MCL crossover was re-measured to be on it's reference, see attached

Images attached to this report
Non-image files attached to this report
Comments related to this report
sheila.dwyer@LIGO.ORG - 11:06, Tuesday 10 March 2026 (89452)

The UGf that Camilla posted above (38.5kHz, with 2W input power before JAC and 5dB gain on IMC IN1) implies that the modulation depth for the IMC is about the same or slightly higher than it was before the JAC installation. See 89046 which was before the EOM crystal swap).

corey.gray@LIGO.ORG - 18:01, Monday 09 March 2026 (89443)

After the IMC was locked, Sheila mentioned for tonight there was not alot which could be done (the next steps would be phasing for sensors out on the In-Air Tables, and after that we could move on to locking DRMI).  But wanted to look at the BS & PR3 alignment.  Before doing that, we did a quick alignment of the Green Arms (to make sure the ITMs were aligned).  

While looking at AS_AIR camera the spot was on the camera but off to the right.  So, SR2 was moved (mostly in yaw) to get the spot halfway centered on the camera (actually we had two spots here); the BS was used to then get the two spots (one from each arm) on top of each other and centered on the camera.  At this point, Sheila mentioned the beatnote looked ok.  Sheila also trended PR3 and said its alignment looked good too.

For the night, the rotation stage is will stay at 2W and the IMC is locked.  We don't want the PSL to go over 2W, until protections for JAC are in place (trigger PD install on the In-Air JAC/IOT1 table?).  And for H1 recovery tomorrow, work will continue for moving on to DRMI locking and beyond.