jenne.driggers@LIGO.ORG - posted 17:42, Thursday 12 March 2026 - last comment - 10:36, Friday 13 March 2026(89491)
PRMI locked 1f using REFLAIR, many analog gains cranked up

[Sheila, Jennie, Jenne, RyanS, Corey]

We have been able to get PRMI locked (with arms held off resonance using ALS).  To do this we:

PRMI locked without too much fuss.  Since we've effectively also increased the noise on the error signals, it's a bit delicate, and I lost lock twice while touching up alignment. The third lock I was able to go a bit slower when touching up BS and PRM alignment, and we've now been locked for more than 20 mins (aka infinity).  Jennie is taking PRCL and MICH OLGs.

The attached image shows all the things that I had changed. 

Nothing is in guardian (except maybe some trigger thresholds which should be reverted), and nothing is saved in SDF. 

Images attached to this report
Comments related to this report
sheila.dwyer@LIGO.ORG - 10:36, Friday 13 March 2026 (89498)

I did a sneaky phasing of POP18 yesterday, by 180 degrees, to make the flashes positive. 

jennifer.wright@LIGO.ORG - 18:06, Thursday 12 March 2026 (89493)

I used the lscparams to change the MICH triggers so I shave put these values back.

Below are OLG TFs I ran from userapps/lsc/h1/templates/PRCL and userapps/lsc/h1/templates/MICH

For PRCL the measurement is shown here where blue is the reference measurement in the tenplate, and red and green are the measurements I took today with different injection amplitudes.

We had to raise the injection in PRCL by a factor of 2.5 ti check the wiggles we can see in the gain between 10 to 30Hz are real.

Here is the measurement for MICH. Not sure we understand either of these yet. More investigation to come tomorrow.

 

Here is an ndscope with the 'good PRMI ACQUIRE time' we were using to scale gains and trigger levels. That is a prmi where we eventually locked and I picked the highest flash that occurred before we did.

Images attached to this comment