Reports until 09:24, Saturday 02 May 2026
H1 CDS
david.barker@LIGO.ORG - posted 09:24, Saturday 02 May 2026 (90094)
PT100A gauge MEDM, code fix installed

I've created an MEDM for the new PT100A EPICS IOC which reads the raw ADC Voltage from h0vacly (TERM14-CHAN2) and converts it to PRESS_TORR. It can be opened via the VE pull down on the SITEMAP (see attached).

The python code pt100a_ioc.py had a connection issue yesterday when we lost network connection to h0vacly during the closure of GV6. This resulted in a freeze of its value until I restarted the service Friday night at 20:50PDT.

Jonathan and myself installed a new version of the code this morning (Sat 02may2026 09:10 PDT) which should handle disconnection events gracefully.

I have added PT100A trending to ndshooter for 1 and 7 day lookbacks, e.g.  vac_pt100a_1_day.png (see attached, yesterday's value freeze clearly seen).

Images attached to this report