Monday afternoon HAM123: Mostly done, one mystery scattering somewhere in/on the IFI assy (Disha, Rahul, Keita)

Summary

Whatever happened to IM1, Rahul did make it better again. Reasons for improvement is unknown but we proceeded with the alignment and we're mostly done.

There is a mystery scattering or maybe clipping somewhere close to the IFI output but not on the output baffle nor DKDP baffle. It could be a scatter from the CWP surface, or a ghost beam somewhere, or something else. It will take a LONG time to diagnose this, and quite likely this existed for a long time. I'm tempted to leave it at this time. But I'll try to take some more pictures.

There's also something weird about the 1st pico mirror PIT actuator for ISS array.

We'd still like to take pictures/measurements here and there on Tuesday.

Done: ASC REFL centering

Following the morning work (alog 90525), REFL ASC censors were centered using RM1 and RM2. About ~30% of DAC range was used for RM2 (RMs_happy_again.png). FYI, using flash peak, [P,Y]=[-0.003, 0.015] for REFL_A and [-0.020, 0.001] for REFL_B. (Doesn't matter how close these are to zero as far as they're within +-0.1 or so and the SUM is decent, but it feels better to be able to get close to zero.)

Done: ISS array centering

Then we looked at the ISS array and the QPD was not centered. A quick adjustment of the second pico that is closer to the array was all it needed (keita_ISS_happy1.png). [P, Y]=[-0.03, 0.05].

Done: IFO REFL baffle (HA13) adjustment

We looked at the IFO REFL baffle (HA13) in front of the HAM2-HAM3 septum window and it was too high even though it was not clipping, so we lowered it by a couple mm. Before: lower edge height = 105.5mm; upper edge = 206.8mm. After: lower edge = 103.6mm; upper edge = 204.5mm.

This baffle was already moved by a couple mm in +Y direction last week (because the beam was closer to +Y edge). See  IFOREFL_baffle_before_relocation.jpg and IFOREFL_baffle_after_relocation.jpg though it might be difficult to see the difference from this picture.

IFO REFL beam looked like IFOREFL_HA13_baffle_after.mov after the height adjustment.

Mystery flashes seen inside IFI output baffle aperture

We proceeded to check the IFI output baffle and I was bothered to find that something that looked like clipping was visible close to the left edge of the baffle using the IR camera. See IFI_OUT_clipped_720p.mov, this is a view from +Y door. But this was less frequent than the flashing itself. In a retrospect, this was probably the reflection from the PRM when the beam was swinging to the left of the video, but anyway we did various things:   

See IFI_out_another_view.mov, this is after the beam quieted down enough and after PRM PIT was changed. The bright thing at the left side of the baffle hole is not visible any more, but you can still see bright-ish scattering of some sort inside the baffle aperture which was there even when Rahul blocked the beam between PRM and IM4. IFI_out_another_view.jpg shows the same thing but with more useful exposure. This is concerning.

DKDP baffle behind the IFI output cwp baffle looked OK (IFI_DKDP_baffle.mp4). BTW, as was reported before, it looked to us that the IFI output baffle has an offset in -X+Y direction relative to DKDP. In the video, the beam on DKDP is slightly biased to the right on average because we tried to split the difference between two baffles.

We moved IM1 in YAW by +-200urad while observing the IFI output by IR viewer to see if there is a better beam position on IFI output. It seemed to me that actually we don't have much space here.

Look at IFI.png to see how the beam is routed through DKDP, output CWP and then passes by the parking beam dump pick-off.   

We'll be better once we're in vacuum because things will be quieter and the MC alignment will be better, so no beam motion and no HOM transmission, but I have to say that the clearance here looks to be unnecessarily narrow. I will NOT touch IFI itself so the only option for mitigation will be to move the parking BD pickoff, but it will be tedious to align that pickoff to steer the beam into the beam dump on top of HAM2. Given the limited time available I'll leave it as is.

We don't know what this scattering is, maybe it's the AR reflection of CWP or DKDP hitting something, maybe it's the surface scatter of CWP. I'll try to take the video from the back of the IFI output beamdump/CWP using a big inspection mirror.

Done: IM4 TRANS centering.

Rahul used pico mirror to roughly center IM4 TRANS while I was monitoring individual segments. IM4TRANS_ROUGHLY_BALANCED.png

Done: IM4 baffle (HA12) moved

As planned. The beam originally was offset in +X direction (IM4_HA12_before.jpeg shows the original location, IM4_baffle_HA12_before.mov shows the beam position), IM4 baffle was moved a bit in -X direction (IM4_HA12_after.jpg, IM4_baffle_HA12_after.mov).

Done but not really: Picturing the picos, one concern for the first ISS pico actuator.

We took three pictures (ISS_1st_pico.jpeg, ISS_2nd_pico.jpeg and  IM4_TRANS_pico.jpeg) but they're not great, the 2nd pico for ISS and the pico for IM4 TRANS don't show how much thread is left for the YAW actuator at all.
The 1st ISS pico is concerning in that the PIT actuator might have lost the ball tip or the stop ring got loose. Will investigate further tomorrow.
Images attached to this report
Non-image files attached to this report
Comments related to this report
keita.kawabe@LIGO.ORG - 14:04, Wednesday 10 June 2026 (90545)

Tuesday update:

Picos

We took new pico pictures today. All picos seem to have decent threads both ways, nothing is close to mechanical stops.

Potential issue I was worried about was that the pit actuator stop ring for iss array pico 1 might be directly contacting the aluminum frame of the mirror holder, which means that the ring got loose or maybe the ball end was lost when it was assembled. See ISS_array_pico1.jpg, the ring is circled in red. I tried to rotate the ring by finger while holding onto the actuator screw so the latter won't rotate, and couldn't move the former. It's not like the ring is loose. Also there seems to be a gap between the ring and the mirror holder frame. Also see ISS_array_pico1_zoom.jpg. These rings were manually removed and put back on during the initial assembly, so my guess is that this specific ring was set shallower than other actuators from the beginning. It's fine.

Beam position in front of PRM was OK

We confirmed that the beam position in front of PRM was pretty good without any adjustment of IMs.

Sliders snapshot

See the screenshot of alignment sliders as of now (even though HAM2 suspensions are in safe mode now, slider values should be valid).

Mystery scatter/whatever update

See alog 90549. I don't know what that is, but it is not the main beam clipping. I recommend to move on. See how Disha, Jennie, Rahul (and myself) feel.

Remaining tasks

Ground check in HAM2/3 for IO/PSL/ISC.

(Added later: Forgot to attach the photo of the retroreflection check iris, so here it is. retro_check_iris.jpg. Each time the IM2-IM3 line changed the iris itself had to be recentered, and then the return beam should be centered on the iris using PRM.)

Images attached to this comment
keita.kawabe@LIGO.ORG - 10:49, Thursday 06 August 2026 (91434)

Note that the anti-whitening in FM4 of H1:PSL-ISS_SECONDLOOP_QPD_SEG filters were all OFF, though it should have been ON.  (Explanation about this in alog 29798.)

This means that the signal was amplified by a factor of 10 for frequency higher than 4Hz.

It's still useful to look at the relative peak heights between segments but don't trust the absolute value. Same thing for H1:PSL-ISS_SECONDLOOP_QPD_SUM and NSUM.