Reports until 22:27, Thursday 25 June 2026
H1 SEI
arnaud.pele@LIGO.ORG - posted 22:27, Thursday 25 June 2026 - last comment - 10:00, Friday 24 July 2026(90763)
HAM3 CPS card setting

Shoshana, Jim, Arnaud

The x6 HAM3 new CPS boards have been set to the following configuration (as per E2200455): 

  board SN probe SN Location
H1 29536 22777 Slot 1 in crate +Y side
V1 38690 22781 Slot 2 in crate +Y side
H3 12563 22779 Slot 3 in crate +Y side
V3 38494 22775 Slot 4 in crate +Y side
H2 23370 22778 Slot 1 in crate -Y side
V2 11950 22780 Slot 2 in crate -Y side

There was some glitching noticed on the channels that were in range prior to this work, which was fixed after this setting change (see attached). Two of the cards were set to Master before and Jim is confident this would have created problems. 

Left to do : 

1- Label the cards at the front of the boards with module SN and corner #
2- Disconnect the grounding to the chamber of the crate on the +Y side 
3- Label the in-air lemo cables with H1, V1, H2 ...
4- Update ICS with the new boards SN
5- Gather the cards that were removed from WHAM3 to send back to microsense for recalibration with a new set of sensors (RMA)

The tracking spreadsheet for this ECR was updated here: E2500184 

Images attached to this report
Comments related to this report
arnaud.pele@LIGO.ORG - 10:00, Friday 24 July 2026 (91230)