Displaying report 1-1 of 1.
Reports until 16:11, Tuesday 23 June 2026
H1 SPI
jeffrey.kissel@LIGO.ORG - posted 16:11, Tuesday 23 June 2026 - last comment - 09:13, Monday 29 June 2026(90718)
SPI Pathfinder Analog LO Phase Rotators Set to 0.0 [deg] and 0.0 [deg]
J. Kissel, for J. Freed

At the last minute on 2026-06-18, Josh figured out that we had errantly been sending the SPI's double mixer two copies of a COS wave of 4096 Hz rather than a SIN and COS (LHO:90680). This was because someone had errantly put a 90 [deg] rotation in the SIN analog output path. He fixed it before he left, but didn't save it in the SDF system and it got lost during Monday's bootfest of h1seih23 (LHO:90689). I'm not sure if Josh (or anyone) tuned it to any specific value, but I've changed the SIN analog rotation phase to 0.0 and accepted it in SDF so we don't lose it.

Josh may add some more details in the comments below, in the comments to his LHO:90680.
Comments related to this report
joshua.freed@LIGO.ORG - 09:13, Monday 29 June 2026 (90790)

During investigation I found that that SUS-R2 rack was energiezed by about 1mV. This was found to be caused by SPI RF Splitter being attached to the rack directly. I ran out of time to correct this before my visitation ended

Displaying report 1-1 of 1.