Reports until 15:16, Wednesday 22 July 2026
H1 SEI
shoshana.apple@LIGO.ORG - posted 15:16, Wednesday 22 July 2026 - last comment - 13:10, Monday 27 July 2026(91179)
CRS Commissioning Updates

We been commissioning the CRS this week, so far we've done a tilt to tilt measurement:

Summary:

Images attached to this report
Comments related to this report
shoshana.apple@LIGO.ORG - 13:10, Monday 27 July 2026 (91257)

Made some adjustments to the CRS_TransferFunction code which generates the SensInv filter.

  • Changed zero Q 50-->30
  • Fixed an issue where we weren't normalizing the CRS TF data to the CPS TF data.
    • Removed a factor of 12.5 orignally used for calibration rather than normaizing to CPS
    • Paramter changes: delta= 1.04e-5m-->1.05528e-05m, w0= 0.0222Hz-->0.0222222Hz, wR/(2pi) = 0.0253Hz--> 0.0254Hz, wg=0.0764Hz-->0.0.0771
  • Put new filter in the 2nd spot in the bank, called SensInv_Meas

 

Filter is saved in : /ligo/svncommon/SeiSVN/seismic/HAM-ISI/H1/HAM3/CRS/Filters/ CRS_SensInv_Filter.mat