Reports until 15:44, Monday 03 August 2026
H1 SQZ
camilla.compton@LIGO.ORG - posted 15:44, Monday 03 August 2026 - last comment - 16:27, Tuesday 04 August 2026(91371)
SQZ OMC Scans and M^2 Measurements with new ZM4 ZM5 PSAMS Preloadings

Sheila, Ryan S, Camilla

We spent the morning repeating 90783, now that ZM4 preloading has been adjusted (90951) and ZM5 has been swapped and now has a different preloading than our O4 ZM5 (91292):

Sheila then used her script to run OMC scans at a grid (below) of PSAMS locations. These initially look great, showing sqz to omc mode mismatch is as good as 1%. with some alignment fluctuations. Ndscope of data taking attached. 

PSAM_VALUES_V5 = [-8, -5.5, -3.3, -1]
PSAM_VALUES_V4 = [-3.2, -1, 1.2, 3.4] 

Ryan then took M^2 measurements on SQZT7 of a slightly different grid:

PSAM_VALUES_V5 = [-8,  -6.75, -5.5, -4.5, -3.3, -1]
PSAM_VALUES_V4 = [-3.2, -1, 1.2, 3.4] 
Images attached to this report
Comments related to this report
eric.oelker@LIGO.ORG - 16:27, Tuesday 04 August 2026 (91390)

Below I calculate the astigmatism based Ryan's grid of M^2 measurements.

 

I compute the 1D overlap between the x and y directions using the q values from the M^2 measurements

eta_1D  =  4*zRx*zRy / ( (z0x - z0y)^2  + (zRx + zRy)^2 )   where z0 is the waist position and zR is the rayliegh length  = pi * w /(M^2*lambda)

The astigmatism, which i express as  1 - eta_1D is tabulated below in %

ZM5  \  ZM4 -3.2 -1 1.2 3.4
-8 0.52 0.52 0.55 0.59
-6.75 0.51 0.48 0.60 0.64
-5.5 0.56 0.55 0.62 0.50
-4.5 0.57 0.56 0.55 0.36
-3.3 0.52 0.50 0.40 0.29
-2 0.42 0.50    
-1 0.56 0.78 0.62 0.15

 

The dependance is pretty weak over much of the grid, but things get a bit squirly in the lower right corner near the positive end of the range for both PSAMS.  We're not as sensitive to the strain gauge setting as ZM2 (91185), but there's clearly a noticible dependence.  