Displaying report 1-1 of 1.
Reports until 18:01, Friday 14 August 2026
LHO VE (VE)
gerardo.moreno@LIGO.ORG - posted 18:01, Friday 14 August 2026 (91555)
BSC8 PT-180 Gauge Removed and Replaced

(Travis, Gerardo)
We removed the old gauge a BCG-450 and installed a new one a BPG-552.  Since the gauge at this location does not play role with relays and such, the old pigtail did just fine, provided the power to the new gauge.  The new gauge is powered on and connected to the same EtherCAT cable as the one that that we removed.  Dead volume of this assembly is getting pumped down with a small can turbo pump and an aux-cart, and a very long flex hose, and probably will continue to pump over the weekend.
No issues were encountered while replacing the gauge.

Images attached to this report