anthony.sanchez@LIGO.ORG - posted 14:20, Friday 02 October 2026 (92173)
Statecounter DRMI No ALS Pre BBS & PRMI No ALS Pre BBS

If anyone is looking for times that the PRMI is locked and the ALS COMM was Down, then Ryan C. Went ahead and found all those times for ya.
please see the following attached text files.

PRMI35-Locked_NoALS100_preBS.txt is a list of GPS time when H1:GRD-ISC_DRMI_STATE_N= 35 (in a PRMI state) AND H1:GRD-ALS_COMM_STATE_N = 100 (the Down State)

This was created via a tool called statecounter found in /ligo/gitcommon/statecounter. 

To run this particular command we used the following:
python3 statecounter.py -chan "H1:GRD-ISC_DRMI_STATE_N H1:GRD-ALS_COMM_STATE_N " -operator "==" -value "35 100" -trend "m-trend" -gpsstart "1198828818" -gpsstop "1459036818" --host h1daqnds0 -port 8088 -output "/ligo/home/anthony.sanchez/Documents/TonysOps/StateCounterResearch/PRMI35-Locked-NoALS100preBS.txt"

I also did the same for a bunch of DRMI states too which are included below.

Thanks for your help dividing and conquering Ryan C!