Displaying reports 2081-2100 of 88717.Go to page Start 101 102 103 104 105 106 107 108 109 End
Reports until 14:20, Wednesday 18 February 2026
H1 AOS
jeffrey.kissel@LIGO.ORG - posted 14:20, Wednesday 18 February 2026 (89181)
Setting Lens Position for SPI In-vac SuK Fiber Collimators: New Measurement Technique Yields Great Success; Both MEAS and REF Collimators Beam Waist Radius within +/- 0.1 [mm]
J. Kissel

Executive Summary
Using 
   - the AxcelPhotonics butterfly diode laser,
   - the "beam splitter / near-field / bypass" measurement setup described in LHO:89123 to rapidly check the beam diameter at z = 0.991 [m] (near field) and z = 5.41 [m] (far field), 
   - elevating the beam height elevated to 5 [inches] to avoid any sort of clipping on other optomechanical setups on the table from other teams, and
   - loosening the lens position set screws only just barely, 
   - paired fiber collimators, in-vac feedthrus (with integrated patch cords), and ex-vac 7.5 m patch cables in-vac feedthrus 

      Beam Path   Char Date    Collimator   Feedthru (Pwr Transmission*)
      MEAS        2026-02-13   S0272503     S3228003 (100%)    
      REF         2026-02-17   S0272502     S3228002 (99%)    

      * Power transmission as reported from SWG:12296

I was "rapidly" tune the lens position, z_lens, for *both* the MEAS S0272503 and REF S0272502 fiber collimators to within 0.010998 (i.e. 11 [mm] - 2 [um]) with uncertainty of +/- 1 [um] , such that 

each fiber collimator sends out a free-space beam whose parameters meets SPI's requirements:
   - the desired waist radius (in both x/y dimensions) , w0 = 1.05 [mm], of within +/- 0.10 [mm], and
   - the desired waist position (in z), z0 = 0.0 [m] to within +/- 0.18 [m].

(where "rapidly" is in quotes: about 4 hours each from "install into measurement setup" and "I'm happy with a final full-position-vector scan). with no signs of strong astigmatism that I saw in the initial setup. (The later point confirms my suspicion that I was clipping on the EOM characterization setup, and there is *no* issue with the laser seed mode, polarization, or the beam splitters).

Support Media

The raw data from the beam profiles of each free-space beam are posted as
    2026-02-17_spi_fc_S0272502_ft_S3228002_7p5mPatchCord_AxcelPhotonicsLaser.txt
    2026-02-13_spi_fc_S0272503_ft_S3228003_7p5mPatchCord_AxcelPhotonicsLaser.txt

where the columns are jammt-friendly format of z Position [cm], Y waist radius [um], X waist radius [um]. 

Notes: 
    (1) as opposed to all previous data sets (e.g. LHO:89047, LHO:86350, LHO:84825) -- I added an additional measurement at z = 0.25 [m] to try to improve the accuracy of the fit beam.
    (2) X is "Axis 1" of the NanoScan parallel to the optical table, Y is "Axis 2," perpendicular to the table. As discussed in LHO:89099, jammt seems to import any three-column dataset such that the first column ends up fit as the "tangential w0," and the second column end up fit as the "w0." With a la mode, the data is typed in a matlab script manually, so X and Y data are modeled separately the entire time without rename, and thus kept consistent. Thus the intentional flip the X and Y axes in the text file such that a la mode and jammt are now both treating w0 = X = Axis 1 = parallel to table, and tangential w0 = Y = Axis 2 = perpendicular to the table.

I imported these beam profiles into both matlab (to run a la mode) and jammt to obtain waist radius, w0, and waist position, z0, fits to the AxcelPhotonics beam profiles, see attached plots:
    S0272502  a la mode  jammt
    S0272503  a la mode  jammt

Some pictures of the measurement setup with the NanoScan head at the new z = 0.25 [m] position (upstream of the beam splitter bypass):
    2026-02-13_FC_S0272503_S3228003_MeasSetup.jpg
    2026-02-17_FC_S0272502_S3228002_MeasSetup.jpg

Some pictures of the clean fiber collimator + vacuum feedthru systems packed up after measurement:
    2026-02-13_FC_S0272503_S3228003_PackedUp.jpg
    2026-02-17_FC_S0272502_S3228002_PackedUp.jpg

Detailed Analysis Results

Here's a table of the fit results from both a la mode and jammt. 

FC + FT S/NModelw0x [m]z0x [m]w0y [m]z0y [m]
S0272502 + S3228002a la mode1.0392-0.0651961.0427-0.020038
jammt1.0392-0.065211.0427-0.02007
S0272503 + S3228003a la mode1.0396+0.177041.0282-0.030537
jammt1.0396+0.177021.0282-0.03051
It's not a typo, the two fitting softwares agree to within the precision of the each display; +/- 10 [um] on both the waist radius and waist position. From here on in this section, since I intentionally paired up fiber collimators and fiber feedthrus to match the last two digits of serial number, I'll refer to them as either "MEAS = S[...]03", or "REF = S[...]02". From the table of fits, you see that the statement in the executive summary about the waist position, z0 = 0.0 +/- 0.18 [m], is defined expanded to cover the X axis waist position of MEAS = S[...]03 z0x = +0.177 [m]. But really, the other axis of the MEAS = S[...]03 FC+FT pair is at z0y = -0.031 [m], and the REF = S[...]02 FC+FT pair is within z0x = -0.065 [m], and the best z0y = -0.020 [m]. So the waist positions are really *quite* close to 0.0 [m]. Good. So let's use these numbers to do recast the fit (using jammt numbers only) into context: (1) Percent Difference between desired waist radius and final measured waist radius: REF, S[...]02 :: (w0x, w0y) = ([1.0392 1.0427] - 1.05) / 1.05 = [-0.0102860 -0.0069524] = [-1.0% -0.7%] Within 1.050 +/- 0.1 [mm] = 1.050 [mm] +/- 9.5 [%] = [1.15 0.95] [mm]? Both axes waist radius are a factor of 10x better than reqs. MEAS, S[...]03 :: (w0x, w0y) = ([1.0396 1.0282] - 1.05) / 1.05 = [-0.0099048 -0.020762] = [-1.0% -2.1%] Within 1.050 +/- 0.1 [mm] = 1.050 [mm] +/- 9.5 [%] = [1.15 0.95] [mm]? Both axes waist radius are a factor of 5x better than reqs. (2) Rayleigh Range: (zR := pi * w0^2 / lambda) REF, S[...]02 :: (zRx,zRy) = (3.1886, 3.2102) [m] MEAS, S[...]03 :: (zRx,zRy) = (3.1911, 3.1215) [m] There's no requirement on where the Rayleigh range sits, but for a waist radius of w0 = 1.05 [mm], we would expect a Rayleigh Range of zR = 3.255 [m], and these values are at most z = -13 [cm] from that or 4% "short" of the target value. This doesn't really matter to SPI, as long as the Rayleigh Range is somewhere in between the ISIK breadboard and the ISIJ reflector 15.427 [m] away. The real requirement is the spot size at the ISIJ reflector, which we need to keep at the design value of 5 [mm] (whose value was determined with the original design waist radius of 1.05 [mm], and the acceptance that we didn't have enough room on the ISIK transceiver breadboard to install telescopic lens solutions to keep the spot size around 1 [mm] both within the transceiver *and* at the ISI reflector). (3) Astigmatism: A := (zRx - zRy) / (zRx + zRy) REF, S[...]02 = -0.003376 = -0.3% MEAS, S[...]03 = +0.011026 = +1.1% Here, again, there's been no requirement on the astigmatism, but ~1% astigmatism doesn't smell too terrible. (4) Spot size at 15.427 [m]: w(z) = w0 * sqrt(1 + (z/zR)^2) REF, S[...]02 :: (x,y) = (5124.569, 5155.038) [um] MEAS, S[...]03 :: (x,y) = (5194.496, 5075.909) [um] Recall the design value of waist radius at the ISIJ reflector, z = 15.427 [m], is w(z = 15.427) = 5 [mm]. As discussed in SWG:12273, that ADC noise with the large spot size is limiting the sensitivity of the pitch and yaw readout, as dx/dTheta ~ sqrt(8/pi) L / w(z). But still, a 1.1% level of astigmatism -- which would result in a different sensitivity / noise performance between pitch and yaw, means that pitch is only ~2.1% worse than yaw. Great! We're good to go!
Images attached to this report
Non-image files attached to this report
H1 IOO (CDS, IOO, ISC)
keita.kawabe@LIGO.ORG - posted 14:15, Wednesday 18 February 2026 (89183)
IMC ASC model needs a better JAC integration

Or, rather, a better JM3 integration and PSL unintegration.

I made a temporary IMC_WFS_MASTER and IMC_WFS_OUTMATRIX_kk screen such that it's easy to route IMC WFS signal to JM3, not the PSL PZT, because I wanted something that works now.

However, right after I made what looks to be an OK screen, I realized that this doesn't work. PIT signal should be routed to JM3 YAW and vice versa. No fully-working IMC WFS until the next model update.

In addition, earlier today Daniel suggested to nuke PSL PZT from the IMC ASC (good idea).

If you want to revert back to the old medm, copy the backup

/opt/rtcds/userapps/trunk/asc/common/medm/imc/IMC_WFS_MASTER_BAK_20260218.adl 

to

/opt/rtcds/userapps/trunk/asc/common/medm/imc/IMC_WFS_MASTER.adl 

Images attached to this report
LHO VE
david.barker@LIGO.ORG - posted 11:29, Wednesday 18 February 2026 (89182)
Wed CP1 Fill

Wed Feb 18 10:12:42 2026 INFO: Fill completed in 12min 38secs

Gerardo confirmed a good fill curbside.

Images attached to this report
H1 General
oli.patane@LIGO.ORG - posted 07:32, Wednesday 18 February 2026 (89179)
Ops DAY Shift Start

TITLE: 02/18 Day Shift: 1530-0030 UTC (0730-1630 PST), all times posted in UTC
STATE of H1: Planned Engineering
OUTGOING OPERATOR: None
CURRENT ENVIRONMENT:
    SEI_ENV state: MAINTENANCE
    Wind: 3mph Gusts, 1mph 3min avg
    Primary useism: 0.02 μm/s
    Secondary useism: 0.44 μm/s 
QUICK SUMMARY:

More HAM1 work today

LHO General
ryan.short@LIGO.ORG - posted 17:06, Tuesday 17 February 2026 (89176)
Ops Day Shift Summary

TITLE: 02/18 Day Shift: 1530-0030 UTC (0730-1630 PST), all times posted in UTC
STATE of H1: Planned Engineering
INCOMING OPERATOR: N/A
SHIFT SUMMARY: Busy day today! The HAM1 EOM was moved to it's final position this morning, JM3 was placed in position downstream of the JAC, and recovery of beam alignment into the IMC is ongoing. Cranes were worked on in the LVEA as well today.
LOG:

Start Time System Name Location Lazer_Haz Task Time End
22:49 SAF LVEA is Laser SAFE LVEA NO* LVEA is Laser SAFE *Bifurcated HAM1/2* Ongoing
16:47 SEI Jeff Opt Lab Local SPI work 21:25
16:49 FAC Kim, Nellie LVEA N Technical cleaning 18:03
16:58 FAC Randy LVEA N Scaffold at test stand in W-bay 17:27
17:00 JAC Keita LVEA YES HAM1 EOM alignment 18:19
17:08 JAC Betsy LVEA YES HAM1 JAC alignment 18:54
17:10 JAC Jason LVEA YES HAM1 JAC alignment 18:33
17:12 FAC Chris MY N Getting parts for FAMIS 18:12
17:17 JAC Camilla LVEA YES JAC table alignment 19:11
17:17 IOO Jennie CR N IMC recovery 18:52
17:48 FAC Crane tech LVEA N Crane repairs 23:30
18:04 FAC Kim FCES N Technical cleaning 18:54
18:14 CDS Fil, Marc LVEA N Cable pulling HAM5/6 20:16
18:24 FAC Nellie MY N Technical cleaning 18:52
18:29 VAC Travis, Gerardo LVEA N HAM6 AIP jack swap 18:40
18:30 JAC Jenne +3 LVEA - Tour and JAC work intro 19:02
18:32 TCS Oli MER N TCS chiller checks 18:40
19:03 JAC Jason LVEA YES HAM1 alignment 20:11
19:27 JAC Jennie LVEA YES HAM1 alignment 20:11
19:32 FAC Kim EX N Technical cleaning 20:15
19:48 FAC Tyler LVEA N Checking on crane tech 19:53
19:53 JAC Camilla Opt Lab, LVEA - Getting parts for JAC table 20:26
21:04 SAF Travis LVEA, EX, EY - Laser safety signage 21:57
21:34 --- Camilla +4 Roof N Sightseeing 21:48
21:45 EE Marc, Fil LVEA YES Finishing up cable pulling in trays above H456 22:30
22:13 FAC Mike, others MY N CEBEX site survey 22:54
22:30 CDS Marc, Fil MY N Getting cables 00:30
22:31 TCS Sophie Prep Lab Local CHETA table work 00:54
22:38 JAC Keita, Jason LVEA YES HAM1 alignment checks (Keita out @ 23:07) 00:12
22:39 SUS Rahul LVEA YES JM3 installation 00:11
22:50 PEM Robert EX N Grounding work Ongoing
22:50 JAC Jennie LVEA YES HAM1 alignment 00:16
22:52 AOS Camilla, Shreyan LVEA, Prep Lab YES JAC table alignment 00:52
22:59 VAC Gerardo LVEA N Looking for parts 23:59
23:09 JAC Betsy LVEA YES JM3 installation 00:15
23:17 FAC Tyler LVEA N Checking on crane tech 23:30
23:21 CDS Tony EX, EY N CDS inventory 00:26
H1 IOO (INS, IOO, ISC)
keita.kawabe@LIGO.ORG - posted 13:36, Tuesday 17 February 2026 - last comment - 09:21, Wednesday 18 February 2026(89171)
JAC EOM moved, looks OK (Jason, Betsy, Keita)

This morning we have pushed the JAC EOM by about 0.6mm (using ~25 thou thick washers) in -Y direction, following the finding of last Friday (alog 89158). 

After that the beam was good on the input side plate (the beam is offset in +Y direction by 0.1mm) and was OK on the output side plate (0.5mm offset in -Y direction).

The beam position on the crystal itself should be ~0.13mm in +Y direction on the input face and ~0.36mm in +Y direction on the output face. The angle between the nominal path and the actual path outside of the crystal is about 0.6 degrees. See pictures and cartoon.

Calculation depends on the refractive index, I assumed n~1+deflection/wedge=1+2.35/2.85~1.85, but using 1.85+-0.5 instead won't change anything in a meaningful manner.

This is acceptable, the beam is more than 1.5mm away from the side face of the crystal, cannot remember the beam radius but it should be smaller than 600um if FDR is still valid, so it might be 2.5 beam radius or maybe more.

Images attached to this report
Comments related to this report
keita.kawabe@LIGO.ORG - 15:30, Tuesday 17 February 2026 (89173)

IFO REFL beam check was done.

After Jennie restored the IMC alignment to post-IMC axes check state, IMC was locked, PRM was alignmed and the IFO refl beam in HAM1 was quickly checked to see if the REFL air path somehow interferes with the new POP periscope stiffener. It didn't.

JM3 swap is ongoing.

Partly in the interest of time, I asked others to go ahead. Rahul and the team are working on it right now.

Yet to be done items:

  • Ghost beams and beam dumps (important).
    • Forward-going beam of S-pol (wrong polarization).
    • There is a reflection of L3 coming back, reflected by JM3 and going high toward JM2.
    • We haven't found the septum reflection yet.
  • JAC RF locking.
  • Modulation depth measurement with the new crystal.
    • It should be done at some point, but after JM3 swap is fine, I'm not worried about huge differences relative to the old crystal. 
  • Beam profile.
    • Should be done in IOT-2L but the beam quality is not as bad now due to new crystal and the mode matching seems to be pretty good, so this is not a priority. Could be done after JM3.
jennifer.wright@LIGO.ORG - 17:59, Tuesday 17 February 2026 (89177)

I calculated the mode-matching before we replaced JM3 and got a limit of 0.26 % for the mode-mismatch as the TM20 mode was hidden in the noise at 100mW input power. We turned up the whitening gain to 42 dB from 30dB to have a better chance and still couldn't see it.

This plot shows the zoomed out ndscope of the TM00 modes and this one shows the max value for TM20.


After JM3 was installed and its position, pitch and yaw had been tuned by Rahul and Betsy to optimise the pointing through our HAM1 irises, Keita, Jenne and I tried to tweak up the alignment with JM3 sliders.

I have left the sliders near here and could not get them much better.

I measure the mode-matching to be 0.43 % with this alignment which is worse by at least a factor of two.

See photo of TM20 mode here.

The 10 and 01 modes are much higher than they were previously, so we will need to do some alignment of the fixed JM2 or JAC_M3 mirrors.

Note for the MM measurement we were accidentally scanning with the MC2 length and the PSL laser frequency so this might make the measurement confusing.

Images attached to this comment
keita.kawabe@LIGO.ORG - 18:12, Tuesday 17 February 2026 (89178)

I closed the light pipe and turned up the purge air before going home.

masayuki.nakano@LIGO.ORG - 09:21, Wednesday 18 February 2026 (89180)

Let me point out that the term “mode matching” used in Jennie’s post is not exactly accurate in this case; it would be more precise to refer to it as the TEM20/02 mode peak fraction. Since there is a large misalignment, the second-order modes are also enhanced. Therefore, that contribution should be subtracted before attributing the remaining fraction to mode mismatch.

H1 SEI
ryan.short@LIGO.ORG - posted 11:57, Tuesday 17 February 2026 (89170)
HEPI Pump Trends - Monthly

FAMIS 39953

Starting about two weeks ago, the pressure at the EX station started getting more "noisy" for some reason. Not sure why this would happen or how significant it is, but noting it here just in case.

Images attached to this report
H1 AOS
jennifer.wright@LIGO.ORG - posted 11:19, Tuesday 17 February 2026 - last comment - 15:38, Tuesday 17 February 2026(89169)
Restoring IMC suspensions to good time from last week

Jennie W, Ryan S, Keita K

 

Summary: MC suspensions back to good time from 10th of Feb, we should only lock the IMC length loop manually during this installation period to avoid the WFS engaging.

 

Today Ryan and I had the task of figuring out why the IMC suspensions seemed to be badly aligned on Friday.

We found a good reference time 16:48:29 UTC on Tuesday 10th Feb at the end of the period where Olli, Jenne and I set the IMC axis back to its nominal state before the vent using ASC loops for DOF 1 and 2 of the IMC plus manual moves of the JM3 mirror in chamber as this cannot be moved by an ASC loop as it is not a tip-tilt currently. See photo of the WFS and MC mirror top mass OSEMS here. Note it is important to choose a time when IMC is in the locked state as the MC2 mirror gets mis-aligned when the IMC guardian is offline.

 

We figured out that the alignment was changed about 19:33:17 UTC on 13th Feb probably by the IMC guardian as Elenna used it to lock the IMC for phase check measurements. See photo, where the vertical cursors are set at the good reference time and today.

After some investigation of the guardian we reminded ourselves that DOFs 3-5 are turned off in the IMC WFS MASTER filter banks. DOF4 and 5 are normally off and DOF3 is intentionally left off because of the replacement of PSL PZT actuator by JM3.

When the IMC guardian is used to lock it automatically triggers the WFS through some logic from the simulink model, and so when Elenna used the guardian to lock it turned on the feedback to DOFs 1 and 2.

Until we install the JM3 tip-tilt and are finsihed most commissioning of the HAM1 hardware we should only lock the IMC manually by engaging the MC-L servo using the common mode servo board controls.

 

Keita and I zeroed the M1 LOCK fiters for all 3 MC mirrors and I changed the alignment sliders so the M1 osems were back to their values from the reference time on the 10th. See photo of ndscope.

Images attached to this report
Comments related to this report
ryan.short@LIGO.ORG - 15:38, Tuesday 17 February 2026 (89174)IOO

To ensure the IMC WFS loops don't cause the MC mirrors or the PZT upstream of JAC to move on us like they did last week, we've turned the outputs of the IMC-DOF_{1,2,3}_{P,Y} filters OFF. Since these outputs are not touched by the IMC_LOCK Guardian, we can now safely use the Guardian to lock the IMC without the concern of WFS turning on and changing alignments.

At some point, the h1ascimc model will need to be updated to send the output of the DOF_3 loop to JM3 instead of the PZT (and medm screens updated too), as that's what's immediately upstream of the IMC now.

H1 TCS
oli.patane@LIGO.ORG - posted 10:53, Tuesday 17 February 2026 (89168)
TCS Chiller Water Level Top-Off FAMIS

Closes FAMIS#28228, last checked 88988

TCSX: 30.5 - Did not add water

TCSY: 10.4 - Did not add water

Flow and filters looked good, but had to remove a notification about preventative maintenance for the filter for both chillers (TCSX, TCSY) in order to see the flow rates. 

No leak in water cup

Images attached to this report
H1 CDS
erik.vonreis@LIGO.ORG - posted 10:40, Tuesday 17 February 2026 (89167)
Workstations updated

Workstations were updated and rebooted.  This was an OS packages update.  Conda packages were not updated.

LHO VE
david.barker@LIGO.ORG - posted 10:22, Tuesday 17 February 2026 (89166)
Tue CP1 Fill

Tue Feb 17 10:13:47 2026 INFO: Fill completed in 13min 43secs

 

Images attached to this report
H1 PSL
ryan.short@LIGO.ORG - posted 08:26, Tuesday 17 February 2026 (89165)
PSL 10-Day Trends

FAMIS 31125

Since the FSS and ISS were re-enabled last week, things have generally been stable in the PSL. The RefCav could probably use some alignment touchup, but it's not too bad for now.

Images attached to this report
H1 PSL
ryan.short@LIGO.ORG - posted 08:17, Tuesday 17 February 2026 (89164)
PSL Status Report - Weekly

FAMIS 39751

Laser Status:
    NPRO output power is 1.834W
    AMP1 output power is 70.51W
    AMP2 output power is 138.8W
    NPRO watchdog is GREEN
    AMP1 watchdog is GREEN
    AMP2 watchdog is GREEN
    PDWD watchdog is GREEN

PMC:
    It has been locked 3 days, 19 hr 53 minutes
    Reflected power = 26.72W
    Transmitted power = 103.9W
    PowerSum = 130.6W

FSS:
    It has been locked for 3 days 15 hr and 53 min
    TPD[V] = 0.4774V

ISS:
    The diffracted power is around 4.0%
    Last saturation event was 3 days 19 hours and 53 minutes ago


Possible Issues:
    PMC reflected power is high

LHO General
ryan.short@LIGO.ORG - posted 07:40, Tuesday 17 February 2026 (89163)
Ops Day Shift Start

TITLE: 02/17 Day Shift: 1530-0030 UTC (0730-1630 PST), all times posted in UTC
STATE of H1: Planned Engineering
OUTGOING OPERATOR: None
CURRENT ENVIRONMENT:
    SEI_ENV state: MAINTENANCE
    Wind: 8mph Gusts, 5mph 3min avg
    Primary useism: 0.03 μm/s
    Secondary useism: 0.39 μm/s 
QUICK SUMMARY: The HAM1 JAC EOM will have some slight alignment adjustments made today before placing the JM1/3 suspensions in their proper positions. HAM7 continues to pump down.

H1 SUS (SUS)
rahul.kumar@LIGO.ORG - posted 17:06, Monday 02 February 2026 - last comment - 16:46, Tuesday 17 February 2026(88998)
PM1 (HAM1) faulty Coil Driver replaced

Dave, Oli, Marc, Fil, Rahul

This morning I switched PM1 (Tip Tilt suspension) in HAM1 chamber from safe state to damped state and immediately the DAC output was saturating. I suspected purge air (which Travis turned it down twice during the day) and later Masayuki also covered PM1 with foil. However, nothing stopped the suspension from saturating.

Then Oli, Dave and I did a model restart and later I power cycled the Satamps for PM1 in the LVEA - nothing helped.

Next, Marc, Fil and I went to the LVEA (checked the satsamp, which was fine) and CER and found the Coil Drivers to be faulty.

New Coil driver - E2400048 s/n 22001180

Old Coil Driver - E2100430 s/n S1106046

SUS PM1 is now not saturating. I will perform the heath checks later on.

Comments related to this report
anthony.sanchez@LIGO.ORG - 17:16, Monday 02 February 2026 (89002)
oli.patane@LIGO.ORG - 16:46, Tuesday 17 February 2026 (89175)

The serial number for the new coil driver has a typo here - it's now S2001180.

Displaying reports 2081-2100 of 88717.Go to page Start 101 102 103 104 105 106 107 108 109 End