Displaying reports 2101-2120 of 88807.Go to page Start 102 103 104 105 106 107 108 109 110 End
Reports until 17:52, Tuesday 24 February 2026
LHO VE (VE)
travis.sadecki@LIGO.ORG - posted 17:52, Tuesday 24 February 2026 - last comment - 23:51, Wednesday 25 February 2026(89254)
BSC1 annulus ion pump (AIP) replaced

The annulus ion pump body for the BSC1 annulus system was replaced.  We then hooked up and started the turbo/aux. cart.  Pressure at the cart was dropping nicely as pumping commenced.  

There will be a pump cart running on the south side of the Y-arm beamtube, near the TCSY table, until the ion pump transition pressure.

Comments related to this report
gerardo.moreno@LIGO.ORG - 23:51, Wednesday 25 February 2026 (89274)VE

The annulus ion pump controller was turned on first thing this morning, and after a few hours the ion pump was able to maintain the pressure of the annulus system.  That allowed us to close the isolation valve.  After lunch the aux cart and can turbo were removed from the annulus system.

Images attached to this comment
H1 TCS
sophie.muusse@LIGO.ORG - posted 17:43, Tuesday 24 February 2026 (89253)
CHETA updates

S. Muusse, C. Compton, G. Vajente


We are still in the process of testing the CHETA electronics integration and have began fixing the optical setup on the ITMY Table to test the sensor in situ.
The optical system was realigned with the lenses, waveplate and polariser repositioned to ensure lower 4.65um intensity on the pickoff to prevent burning after the issues in post. All core optics for the 4.65um beam have been placed and we are in the process of adding the sensor paths and laser dumps. 

Electronics:
We tested all the laser diode and TEC controller ports on the chassis which were working. It is worth noting when connected to the Laser Enable control the diode will not turn on unless this is enabled and can be used to shut off the laser power.
The thermal power meter input was also working and power changes can be seen on ndscope
I've put in a table the status of all the CDS I/O we've tested so far:

Sensor Status Channel
Thermal Power Meter Voltage Operational  H1:AWC-ITM(OPTIC)_PD_C_VOLTS
Laser Enable Operational H1:AWC-ITM(OPTIC)_LASER_ENABLE
Laser current Operational H1:AWC-ITM(OPTIC)_LASER_DIODECURRENTMONITOR
Laser Temperature monitor Operational but uncalibrated H1:AWC-ITM(OPTIC)_LASER_DIODETEMPMONITOR
Flipper Operational but not installed H1:AWC-ITM(OPTIC)_FLIPPER_1
Rotation stage Not operational  H1:AWC-ITM(OPTIC)_POWER

Some notes are that:
PD_C is the thermal powermeter 
PD_A and PD_B are the PDs

We aim to installl the PD setup tomorrow and test its electronics. 


Medm
Adjacently, there was continued progress on the medm, a flipper control was installed using SQZT7 code, the slow PD was added using LSC_CUST_DCPD.adl and QPD using QPD.adl. Both will be tested in the coming days on the actual system and the rest of the controls added.

H1 AOS
joshua.freed@LIGO.ORG - posted 16:51, Tuesday 24 February 2026 - last comment - 10:56, Wednesday 25 February 2026(89247)
SPI, Photodiode through TIA wiring check

J. Freed (with help from Marc and Fil)

I tested the real wiring chain described in D2400111 from PD through the 3 variants of the TIA and it does follow exactly what is described in the link. There were 4 things of note that were found during this test. 


1. All the whitening filters were switched "on" inside the TIA, however our final design document states that only the QPDs need whitening. As such the SPD boards S2500647 and S2500645 whitening switches were set to bypass. I logged this change in the E-Traveler.


2. The D1700116 silicone circuit board for the FFD-200 causes shorts. The main issue is the GAP 5000 pinholes on the PD side of the board. If the PD is flush with the board those pins touch the case of the FFD. Since the GAP pins are also connected to the cathode and anode, this causes the circuit to short. This is simple enough to test without taking out any PDs from the case. If there is "no" resistance between the case (ground) pin and the anode/cathode pins on the DB9 connector coming from the PD, then it is shorting and the system should not be turned on. There are 2 options suggested to fix this, either put insolation between the GAP pins and the FFD case or cut the GAP pins connection to the FFD anode/cathode. For this specific test, the issue was bypassed by putting in a tissue between the FFD and the silicone board.


3. I tried to take transfer functions from all the PDs through the TIA, however the laser I used (the MIT ISC AM Laser) AM modulation was designed for 5 - 200 MHz, not the 4096Hz we are trying to use. As such, I suspect the harsh attenuation (~70dB at 4096Hz AOM_Attinuation.png) I measured was caused by the laser. So I decided it would be better to put off the transfer functions through the TIA until after SPI is built, then use our own laser AOM system to run the test. The laser was just left at DC and was used as the light source to see if signals on the PDs follow the correct wiring chain.


4. I used the laser to check that the signals on the PDs follow the expected wiring chain through the output of the TIA. Ex. Laser on Quadrent 1 of the QPD outputs a voltage on the expected pin on the output of the TIA. All pins were found to be correct.


 

Images attached to this report
Comments related to this report
jeffrey.kissel@LIGO.ORG - 10:56, Wednesday 25 February 2026 (89264)
We checked the production units, and they do NOT suffer from the shorts described in item 2 above. *phew* Great work Dean!
See details in LHO:89263.
H1 AOS
betsy.weaver@LIGO.ORG - posted 16:39, Tuesday 24 February 2026 (89249)
JAC output periscope 2nd septum refl beam dumped
Jason, Jennie, Betsy

After working for a bit to try to beam dump the second Septum refl beam dump which also is coming off the IMC septum window, we finally came to a solution.  It involved stealing one of the SPI D1800140-07 smallest beam dump panels and also putting it into the same mount as the first panel.  These 2 beams are pretty close to the main beam at this location, but with the beams otherwise hitting the internal metal of the output periscope we could not come up with anything better.  It took us quite a few small adjustments and many pictures to convince ourselves we are not clipping, but the attached picture is the best visual of the situation.  Commissioners agree that this is what we will live with.
Images attached to this report
LHO General
ryan.short@LIGO.ORG - posted 16:33, Tuesday 24 February 2026 (89248)
Ops Day Shift Summary

TITLE: 02/25 Day Shift: 1530-0030 UTC (0730-1630 PST), all times posted in UTC
STATE of H1: Planned Engineering
INCOMING OPERATOR: N/A
SHIFT SUMMARY: Another productive day working towards closing out HAM1.
LOG:

Start Time System Name Location Lazer_Haz Task Time End
22:49 SAF LVEA is Laser SAFE LVEA NO* LVEA is Laser SAFE *Bifurcated HAM1/2* Ongoing
15:42 FAC Kim, Nellie LVEA N Technical cleaning 16:09
15:47 FAC Eric Site N Running fire pumps 16:22
15:55 FAC Tyler, cont. EY N Groundwater sampling 16:17
16:36 SPI Jeff Opt Lab Local SPI characterization 22:39
16:36 CDS Fil LVEA N HAM5 electronics rack work 21:16
16:37 TCS Camilla Opt Lab N Inspecting viewports 18:00
16:41 FAC Kim LVEA N Technical cleaning 17:24
16:54 OPS Gabriele +2 LVEA N Tour 17:50
17:23 JAC Betsy LVEA YES Adjusting covers 17:44
17:24 VAC Travis LVEA n Checking on GV6 17:34
17:25 JAC Sheila LVEA YES Opening light pipe 17:40
17:25 FAC Randy LVEA N Walkabout in W-bay 17:41
18:06 FAC Randy LVEA - Changing out cleanroom bolts (craning at height) 20:33
18:09 CAL Oli PCal Lab N Checking spare lasers 18:25
18:16 CDS Marc LVEA N HAM3 electronics rack work 21:16
18:36 SUS Oli MER N Checking SUS racks 18:44
18:37 VAC Jordan LVEA N Opening HAM7 ion pump 19:09
19:03 VAC Travis LVEA - Checking HAM1 feedthrus 19:08
19:13 JAC Jason LVEA Yes HAM1 beam hunting 20:55
19:20 JAC Jennie LVEA Yes HAM1 beam hunting 20:56
19:48 TCS Sophie Prep Lab N Hunting for screws 19:54
20:28 JAC Sheila LVEA Yes Delivering keys, centering IMC WFS 20:58
20:33 FAC Randy LVEA - Craning to replace cleanroom bolts 22:24
21:19 VAC Jordan LVEA N Setting up BSC1 AIP swap 21:44
21:33 IOO Sheila LVEA N Centering IMC WFS 21:44
21:33 JAC Keita LVEA Yes HAM1 alignment 21:44
21:42 TCS Sophie Prep Lab Local CHETA table work Ongoing
22:06 TCS Camilla Prep Lab Local CHETA table work Ongoing
22:17 VAC Gerardo, Jordan LVEA - AIP replacement on BSC1 Ongoing
22:28 VAC Travis LVEA N Disconnect GV6 pump cart 01:08
22:29 JAC Jason, Jennie, Betsy LVEA Yes HAM1 cleanup; Betsy out @ 00:17 00:28
22:29 AOS Sheila, Shreyan, Bin LVEA - Looking around at HAM1 22:58
22:34 SUS Oli LVEA N Verify existence of a sat amp 22:43
22:41 SUS Dave MER N SUS rack work Ongoing
23:12 SUS Oli CER N Looking at a chassis 23:16
23:25 SUS Oli CER N Looking at a different chassis 23:29
H1 IOO (INS, IOO, ISC)
keita.kawabe@LIGO.ORG - posted 15:58, Tuesday 24 February 2026 - last comment - 17:28, Tuesday 24 February 2026(89246)
JAC Tuesday (mostly Jennie, Jason, Betsy, Sheila)

Alignment into HAM2

Locked JAC with RF at 1W. IMC WFS was centered in IOT2L and IMC started working. As we steered JM3 MC2 TRANS responded as expected (i.e. JM3 PIT -> MC2 YAW and vice versa though there's a significant cross coupling). Sheila had to recenter the WFS once again at some point as the WFS started to get off-centered as we turned JM3, but as far as the WFSs were centered, things worked.

In the end, MC2 TRANS was centered reasonably well (right before the cursor in the attached), JM3 DAC output was O(1e7) while a 28 bit DAC's range is +-134e6.

Apparently we made the last step of JM3 PIT adjustment in the wrong direction at the time (we didn't notice because the WFS is very slow) and overshot. I steered it back later, now H1:SUS-JM3_M1_OPTICALIGN_P_OFFSET is -39 instead of -19 (second screen shot).

Anyway, this means that the alignment into HAM2 is good with more than a comfortable range left for JM3. No need to further refine.

One caveat is that the IM4 trans is totally off in PIT. But that's a downstream problem which we'll have to deal with later in HAM2. That should not prevent us from moving forward to close down the chamber.

The tasks listed below are described in different alogs.

JAC TRANS PD calibration

Last beam dump (alog 89249)

ALS beam path check

 

Images attached to this report
Comments related to this report
jennifer.wright@LIGO.ORG - 17:28, Tuesday 24 February 2026 (89251)

Summary: JAC TRANS PD well aligned, rough power budget done, ALS beam from PSL does not hit any wires or components before reaching its intended steering mirror in HAM1.

 

POWER BUDGET

Jason and I went into do some measurements on the TRANS PD path after 11am. We were unsure yesterday that this PD was well aligned after the laser window installation.

The beam going to the TRANS PD matches roughly what we expect with the uncoated laser window we now have as BS1. Here is a photo showing the power Keita and Jason were getting after swapping in the laser from yesterday (in the lower left plot).

There was approx 0.03 on TRANS PD. Previously with a HR mirror in place of BS1 we had ~ 3 on TRANS PD (see lower left plot on ndscope).

Keita did a calculation of the rough power reflected from BS1, assuming an AOI of both 40 degrees or 35 degrees (AOI should be around 39 degrees according to layout).

rp=tan(theta-phi)/tan(theta+phi)

theta is the AOI and phi is the angle of refraction,

phi = asin(sin(theta)/n),

n=1.4496 for fused silica at 1064nm.

rp(theta=40deg)^2 = 1.14%

rp(theta=35deg)^2 = 1.63%

This means that the beam is likely not clipping on the TRANS PD as the power on it seems to have scaled as we expect with the laser window installation.

To double check this and provide a calibration for this PD we did some power meter measurements in chamber.

We measured the output from the input side curved mirror of the JAC (Te2), with the PSL set to 1W output using the rotation stage (otherwise it is hard to see this beam on the card).

JAC Te2 = 2.7 mW

JACT_BS1 transmitted beam = 2.4 mW

JAC TRANS PD beam = 37 microW

This leaves us with 0.263 mW unaccounted for in transmission, this puzzles me.

We put the power out of the PSL down to 100 mW to measure the input power and output power in HAM1.

JAC input power = 115 mW
HAM2 input power/after HAM1 output periscope= 96mW
 

ALS BEAM CHECK

Jason opened the light pipe and checked that beam does not intersect anything int he new installed path before reaching its SM that directs it towards ISCT1.

Images attached to this comment
H1 ISC (CDS, ISC)
keita.kawabe@LIGO.ORG - posted 14:58, Tuesday 24 February 2026 - last comment - 15:21, Tuesday 24 February 2026(89244)
ASC QPD (not WFS) whitening gain were somehow set to zero

It seems that whitening gains of some corner station QPDs were somehow set to zero on Friday Feb/20 17:22 UTC (09:22 PST).

Not sure why this happened, this seems to be earlier than the failed effort to update h1imcasc model (alog 89208). ALS QPDs, end station QPDs and all WFS RFs are good. Was something done to Beckhoff that day? 

I first noticed this for MC2 trans yesterday because it was interfering with IMC locking and WFS triggering. I checked all QPDs and WFS today and found that the following channels were affected. I restored them all to the value right before it was set to zero. 

channel old (dB) new (dB)
H1:IMC-MC2_TRANS_WHITEN_GAIN 0 30
H1:IMC-IM4_TRANS_WHITEN_GAIN 0 18
H1:ASC-AS_C_WHITEN_GAIN 0 18
H1:ASC-OMC_A_WHITEN_GAIN 0 27
H1:ASC-OMC_B_WHITEN_GAIN 0 27

 

Images attached to this report
Comments related to this report
ryan.short@LIGO.ORG - 15:21, Tuesday 24 February 2026 (89245)

Trending the uptime of the Ethercat system, slow controls were restarted and came back up two seconds before the time listed in Keita's alog, likely a part of Daniel's updates to include CHETAX electronics (alog89211). Settings may just have not been fully recovered after that restart.

LHO VE
david.barker@LIGO.ORG - posted 10:47, Tuesday 24 February 2026 (89243)
Tue CP1 Fill

Tue Feb 24 10:14:58 2026 INFO: Fill completed in 14min 54secs

 

Images attached to this report
H1 CDS
david.barker@LIGO.ORG - posted 07:59, Tuesday 24 February 2026 (89241)
bypass fire pump alarms while churn testing is ongoing

Bypass will expire:
Tue Feb 24 11:57:58 AM PST 2026
For channel(s):
    H0:FMC-CS_FIRE_PUMP_1
    H0:FMC-CS_FIRE_PUMP_2
 

LHO General
ryan.short@LIGO.ORG - posted 07:43, Tuesday 24 February 2026 - last comment - 08:42, Tuesday 24 February 2026(89239)
Ops Day Shift Start

TITLE: 02/24 Day Shift: 1530-0030 UTC (0730-1630 PST), all times posted in UTC
STATE of H1: Planned Engineering
OUTGOING OPERATOR: None
CURRENT ENVIRONMENT:
    SEI_ENV state: MAINTENANCE
    Wind: 3mph Gusts, 1mph 3min avg
    Primary useism: 0.03 μm/s
    Secondary useism: 0.29 μm/s 
QUICK SUMMARY: In the homestretch on HAM1 alignment activities and JAC commissioning, which continues on this rainy morning.

Comments related to this report
ryan.short@LIGO.ORG - 08:42, Tuesday 24 February 2026 (89242)

The IMC_LOCK Guardian had been left trying to acquire all night with the light pipe closed, so I set it back to DOWN when I noticed that this morning.

H1 CDS
erik.vonreis@LIGO.ORG - posted 06:35, Tuesday 24 February 2026 (89238)
Workstations updated

Workstations were updated and rebooted.  This was an OS packages update.  Conda packages were not updated.

H1 TCS
sophie.muusse@LIGO.ORG - posted 23:22, Monday 23 February 2026 (89237)
CHETA Update

02/23 S. Muusse, C. Compton, G. Vajente, S.Goswami, B. Wu 


The electronics chassis was brought into the lab today (thanks Phil and Dave) and we began testing the integration of the optomechanics with the CDS. An ethernet cable was run into the JOAT CHETA lab to connect to the server.  A variable power supply was brought into the lab to power the chassis at the required 24V along with a linear power supply required for the rotation stage and translation stages. 
The flipper I/O input and output had to be configured for Beckhoff communications using this guide.
The current status of our testing is as follows:
Working:

Not working:

Untested:

We have realised during this process that the flipper isn't powered by the SMA connectors and requires a seperate power source. This was not considered in the initial panel design and is not currently supplied by the chassis. There is a spare blank connector input/output slot which can be used. 


We have begun making the medm display for the CHETA system based on the current CO2 medm which shares many optomechanical systems. CHETA isn't currently on the TCS screen so to run the medm display currently the following command must be run to access the work in progress. 

medm -x -macro 'USERAPPS=/opt/rtcds/userapps/release/,SITE=LHO,site=lho,IFO=H1,ifo=h1,OPTIC=X,OPTICF=ITMX,name=AWCITMX,RT_MEDM=/opt/rtcds/lho/h1/medm' TCS_CHETA.adl 

To open the medm in a configurable format:
 medm TCS_CHETA.adl 
Alternatively to edit the code files:
code medm TCS_CHETA.adl 

 


Further alignment on the ITMY table was completed with almost all optics now mounted on the table. 

Images attached to this report
H1 IOO (INS, IOO, ISC)
keita.kawabe@LIGO.ORG - posted 18:58, Monday 23 February 2026 - last comment - 17:50, Monday 16 March 2026(89236)
JAC monday

We installed JM1, balanced it and aligned it. A beam dump was placed behind it though we could not see the transmission with 1W input.

After this, JAC locked with RF without any problem though the input was wobbly when the purge was up.

We searched for unexpected ghost beams (also with 1W input) and didn't find any.

We uninstalled many (but not all) temporary dog clamps and irises.

We revisited the IMC alignment because it's been off in PIT since Thursday or Friday. We locked JAC using dither (because we wanted to turn down the purge air). We enabled the IMC WFS just for MC optics and steered JM3, but weren't able to center the MC2 trans. Steering JM3 just made the IMC transmission worse while making not much impact on the desired degree of freedon (JM3 PIT -> MC2 trans YAW, JAM3 YAW -> MC2 trans PIT).

Tomorrow, we'll revisit the IMC alignment. We'll also measure the power coming into JAC TRANS PD as well as the actual transmission of JAC while locking it with RF so we can use JAC trans PD as the measure of the power into HAM1.

Comments related to this report
betsy.weaver@LIGO.ORG - 07:54, Tuesday 24 February 2026 (89240)
FYI, there are about 24 beam dumps now installed on this table.
Images attached to this comment
corey.gray@LIGO.ORG - 14:28, Tuesday 03 March 2026 (89342)EPO

Tagging for EPO photos

keita.kawabe@LIGO.ORG - 17:50, Monday 16 March 2026 (89529)

One of the beam dumps on the picture was most likely NOT in its final place.

See my annotated version, the BD circled in orange is probably JM1 trans beam dump and relocated to the final location after this picture was shot.

In Feb/26 alog, this picture of Betsy's doesn't show the mystery dump and instead shows the JM1 trans beam dump in its final location, I think.

Images attached to this comment
LHO VE (VE)
travis.sadecki@LIGO.ORG - posted 18:47, Monday 23 February 2026 - last comment - 17:32, Tuesday 24 February 2026(89235)
GV6 annulus ion pump (AIP) replaced

Today, Gerardo replaced the annulus ion pump body for the GV6 annulus system.  He then handed off to me to hook up the turbo/aux. cart.  The pressure at the cart was ~3e-5 after 4 hours of pumping.  

There will be a pump cart running at GV6, at the Y-arm termination slab, until the ion pump transition pressure.

Comments related to this report
travis.sadecki@LIGO.ORG - 17:32, Tuesday 24 February 2026 (89252)

Transitioned to ion pump successfully.  Aux cart and turbo were removed.

LHO General
ryan.short@LIGO.ORG - posted 17:23, Monday 23 February 2026 (89234)
Ops Day Shift Summary

TITLE: 02/24 Day Shift: 1530-0030 UTC (0730-1630 PST), all times posted in UTC
STATE of H1: Planned Engineering
INCOMING OPERATOR: N/A
SHIFT SUMMARY: Another productive day with work continuing in HAM1; JM1 is in place and more alignment ongoing.
LOG:

Start Time System Name Location Lazer_Haz Task Time End
22:49 SAF LVEA is Laser SAFE LVEA NO* LVEA is Laser SAFE *Bifurcated HAM1/2* Ongoing
15:45 FAC Randy LVEA N Walkabout in W-bay 16:25
16:06 FAC Kim, Nellie LVEA N Technical cleaning 16:25
16:49 FAC Kim, Nellie LVEA N Technical cleaning 17:27
16:52 VAC Travis LVEA - Checking purge air @ HAM1 17:07
17:00 JAC Keita LVEA Yes HAM1 alignment 20:33
17:11 JAC Betsy LVEA Yes JM1 install 20:32
17:15 SPI Jeff OpticsLab y(local) SPI work 20:10
17:24 FAC Randy, Jim LVEA n Test stand work 17:53
17:31 JAC Jason LVEA YES HAM1 alignment 20:32
17:40 SPI RyanS OpticsLab y(local) SPI work 20:04
17:45   Camilla, Marc JOAT Lab n Installing ethernet cable 17:59
17:45 FAC Nellie MY n Tech clean 18:21
17:54 FAC Randy, Jim MX, MY n Looking for parts 20:45
18:22 TCS Camilla, Sophie LVEA n Grabbing TCS laptop 18:57
18:38 FAC Tyler LVEA, MX, MY n 3IFO checks 19:42
18:39 VAC Jordan LVEA n RGA scans 19:50
18:39 VAC Gerardo LVEA YES Looking for rigging cable 19:50
19:43 FAC Tyler JOAT Lab n Watching paint chips fall 19:45
19:51 VAC Gerardo LVEA n Swapping ion pump for GV6 22:00
20:43 VAC Travis LVEA N Ion pump swap 22:00
20:45 FAC Randy LVEA N Rigging assembly 21:16
20:46 SPI Jeff Opt Lab Local SPI work 23:25
21:06 TCS Sophie, Gabriele, Bin Prep Lab Local CHETA table work 22:51
21:20 TCS Shreyan Prep Lab Local CHETA table work 22:51
21:41 JAC Keita, Jason LVEA Yes HAM1 alignment Ongoing
21:46 JAC Betsy LVEA Yes HAM1 alignment 00:13
22:14 VAC Jordan LVEA N Checking AIP @ Y-manifold 22:23
22:45 TCS Camilla Prep Lab Local CHETA table work 00:16
22:50 ISC Elenna Opt Lab - Preparing for BHSS 23:19
23:12 TCS Sophie Prep Lab Local CHETA table work 00:08
23:14 VAC Travis LVEA N Checking AIP 23:20
Displaying reports 2101-2120 of 88807.Go to page Start 102 103 104 105 106 107 108 109 110 End