Displaying reports 2581-2600 of 88977.Go to page Start 126 127 128 129 130 131 132 133 134 End
Reports until 08:51, Wednesday 28 January 2026
H1 SQZ
sheila.dwyer@LIGO.ORG - posted 08:51, Wednesday 28 January 2026 (88939)
clipping of SQZ beam after cable dressing

Yesterday Rahul and I went to HAM7 to try to address the suspension problems reported in 88913.  

I watched the beam on SQZT7 irises in the homodyne path while Rahul moved cables away from the suspended platform, the beam moved as he shifted the cables near the V3/H3 osems (the hard to reach ones) away from the platform, but not so much that we lost the beam.  He also tried lifting the cable connector for the new translation stage on and off the OPO, this had a similar impact on the alignment but we never lost the beam.  

We left the connector as it was, but moved the cables away from the platform.  The beam coming out of the chamber was hitting the top of the upper periscope mirror on SQZT7, clipping somewhat there.  We took the power meter in chamber and measured 20-30% losses between the beam leaving the platform towards the filter cavity and the beam returning in transmission of SFI1, which was pretty consistent with the power measured on SQZT7.  

Jeff re-evaluated the suspension health 88921 yesterday afternoon.  This morning from the control room I moved ZM1 in pitch -1800 urad which seems to have relieved the clipping according to the OPO IR TRANS PD, but has saturated ZM1 pitch.  This can probably be offloaded to A:M3 to relieve the saturation.

H1 SEI
oli.patane@LIGO.ORG - posted 08:25, Wednesday 28 January 2026 (88932)
BRS Drift Trends - Monthly FAMIS

Closes FAMIS#38813, last checked 88386

BRS Driftmon
Auxiliary BRS Channels

Everything is looking normal

Images attached to this report
H1 General
oli.patane@LIGO.ORG - posted 07:32, Wednesday 28 January 2026 (88931)
Ops Day Shift Start

TITLE: 01/27 Day Shift: 1530-0030 UTC (0730-1630 PST), all times posted in UTC
STATE of H1: Planned Engineering
OUTGOING OPERATOR: None
CURRENT ENVIRONMENT:
    SEI_ENV state: MAINTENANCE
    Wind: 4mph Gusts, 3mph 3min avg
    Primary useism: 0.03 μm/s
    Secondary useism: 0.33 μm/s 
QUICK SUMMARY:

LVEA is still LASER HAZARD

H1 ISC (ISC)
keita.kawabe@LIGO.ORG - posted 21:00, Tuesday 27 January 2026 - last comment - 06:56, Wednesday 28 January 2026(88927)
JAC EOM update Tue/Jan/27 (Elenna, Keita, phone consultation with Valera)

Summary:

A day of success.

Comments related to this report
keita.kawabe@LIGO.ORG - 21:36, Tuesday 27 January 2026 (88928)

How crystal mounting was done.

We did "in-between" method (alog 88900) and inserted two pieces of 3/8IDx5/8ODx0.025" thick shim washers between the front plate and the input side plate.  shim_washers_spacers.jpg shows the washers and the front plate before the rest of the EOM structure is placed on top. Note that the front plate still has the alumina piece on top, not the RTP. Important points in this picture:

  1. We're using two pieces of alumina pieces as a convenient 4mm thick shim to raise the front plate. It doesn't have to be alumina pieces, but the front plate must be raised enough so the shim washers "clear the ground".
  2. Three set screws are pre-adjusted so each sticks out just shy of 3.5mm. This is the height of the crystal (4mm) minus the depth of the shallow groove (nominally 0.02" or 0.508mm). This made it somewhat easier to to make sure that there's a good contact between the crystal and the metals.

(Added later: If I were to do this again, I'll set the set screws with alumina piece in place such that all touch the board when there's a good contact between board/plate/alumina (of course no indium). Insertion of indium foil with the real RTP later will automatically ensure that the screws are just shy.)

Next we cut a 40mmx4mm piece of indium sheet with a clean pair of scissors and installed it in a groove in the front plate. I tried to set the edge of the sheet to be 7.6mm from the outside edge of the front panel (this is 7mm plus the thickness of 0.025" washer). Judging from indium.jpg, I was mildly successful, maybe it's more like 7.4mm but it's not 7mm nor 8mm.

rtp.jpg shows the side view of the crystal. Maybe it's hard to see but it's wedged, in this picture the shortest face is down, the longest side is up.

I placed the crystal on top of the indium sheet, making sure that the edge of the crystal is well aligned with the edge of the indium as good as I can. We also made sure that the shortest face mates with the front panel. You cannot see any of that in the crystal_installed.jpg but you can at least see that the crystal is there.

Then we went through the same procedure we've already done more than several times, i.e. tighten the screws on the input panel until the panel touches the washer and the washer touches the front panel, tighten the scrwes on the output panel so the screws touch that panel, then go balanced tightening, moving just a tiny amount at a time, always applying small downward pressure for the EOM side/board/bottom assy otherwise the assy will shift when the screws are tightened. When all of the screws are tightened stronger than finger tight, screws on the input side are tightened just a bit more. After this, neither Elena nor I weren't able to undo screws by finger.

Sorry no picture of the assembled unit.
 

Images attached to this comment
keita.kawabe@LIGO.ORG - 23:35, Tuesday 27 January 2026 (88929)

Tuning is done, larger capacitance than obtained before with alumina, looks good. (But why do the dips have to be so narrow?)

We noticed that the frequencies were lower than what we have previously obtained with alumina, i.e. the capacitance is bigger. This is probably a good sign even though we don't know if this is due to the indium or something else. Especially, 118MHz dip was a MHz or two lower than nominal.

We were able to tune all four frequencies using trim cap, except that the trim cap for 45.5MHz hit the minimum and we could not increase the frequency any more, so we bent the winding of the coil a bit to spread loops apart. Below is the table of center frequencies (actual vs nominal). In the attached photos, cursor is placed close to the nominal frequency. They all look good in that the frequency is close enough to nominal that we're only loosing less than a dB, but the resonances are all very narrow (for my preference, anyway). The Q values are from 640 for 9MHz to 1300 for 118MHz, going higher as the frequency. A small change in frequency will result in a big degradation in the modulation depth.

(Added later: Read Valera's entry below, thanks Valera! The numbers here are not the real Q, they should be smaller. To make it more embarrassing, I somehow mixed up 3dB and 6dB. Given that all dips are smaller than -20dB, a quick thing to do is probably to define the width of the peak as full width of the -3dB points in S11, not +3dB points from the bottom but really -3dB measured from 0dB full reflection. If you do that the numbers are more like 100 instead of 1000.)

If you look at the pictures, you'll also notice that the reflection dips at the center are -23dB (9MHz), -24.5dB (24MHz), -23dB (45MHz) and is -25dB (118MHz) so a bit smaller than 10% in amplitude is coming back. It's not really matched to 50 Ohm transmission line, and that on its own is OK, but because of that, I wonder if we can add a bit of resistance to bring down Q values without any negative impact (like worse matching with increased reflections) in the future design. 

Tuned center Nominal Full width of 6dB points from the bottom / Q
9.0995 9.100230 14.3k / 636
24.07705 24.078360 29.7k / 810
45.5043 45.50115 57k / 798
118.3055 118.30299 89k / 1329

After this first round of tuning, three set screws on the front plate were all extracted, and there was no change in the tuning of 118MHz dip.

I changed the orientation of the EOM and the frequency jumped a bit

Up to this point, tuning was done with the front plate facing down and put on the ceramic insulator placed on the EOM base (because it's convenient to access trim caps that way).

When I changed the orientation of the EOM so the front plate becomes upfront (i.e. like intended), the frequency of 118MHz dip shifted a bit, from 118.3055MHz to 118.31745MHz, it's just 12kHz shift so not the end of the world but it's still meaningful. Maybe it's the interaction of the magnetic field from the coil and the metals nearby?

Then I tapped the front plate and side plates and it shifted again, fortunately by smaller amount (from 118.31745 to 118.3113MHz, a negative 6kHz jump).

What we'll do tomorrow is to fully assemble the unit, tune it again as good as we can, then tap and retune if necessary. Hopefully, tapping enough and things will settle to the bottom of the potential.

Once the EOM goes into chamber we'll measure the resonances again, and we might have to retune in chamber.

Images attached to this comment
valery.frolov@LIGO.ORG - 06:56, Wednesday 28 January 2026 (88930)

I was also wondering why the S11 (return loss) is narrower then the transmission curve back when we did the prototype testing at LLO. So I did the math myself - the attached plot shows the calculated curves for voltage across the crystal for 1 W incident RF power and S11 for 9.1 MHz (similar for other f's). Initially I also made the same mistake estimating the Q - the Q is actually about 100 not ~1000 as one can see from the transmission curve (voltage on the crystal).   

Images attached to this comment
H1 AOS
masayuki.nakano@LIGO.ORG - posted 18:55, Tuesday 27 January 2026 (88926)
HAM1 alignment work

[Jennie, Jason, Masayuki]

Summary:

We aligned the HAM1 output beam to the IMC and verified the power transmission through HAM2. The beam path through JAC_L2/L3 was centered, and alignment to the IMC was improved. Preparation for EOM installation is nearly complete, with final measurements planned for tomorrow.


Details:

 

H1 CAL
anthony.sanchez@LIGO.ORG - posted 17:42, Tuesday 27 January 2026 (88924)
PCAL EX End Station Measurement.

Dripta & I went to the EX to do a PCAL End station measurement followed by a TX module maintenance.

Obligitory Beam spot pic.
We followed T1500062-V21, with out much deviation until the measurements were finished. We did continue on with a TX module maintenance that we have not yet finished yet. Our plan is to go back tomorrow to finish the OLTF Optical Follower Servo measurement. We did leave the LASER HAZARD STATUS at EX in SAFE

The ES measurement went smoothly.
Beam spot after ES measurement & TXmodule maintence!

python generate_measurement_data.py --WS PS4 --date 2025-11-03
Reading in config file from python file in scripts
../../../Common/O4PSparams.yaml
PS4 rho, kappa, u_rel on 2025-11-03 corrected to ES temperature 299.5 K :
-4.7017855975867215 -0.0002694340454223 2.686163396659873e-05
Copying the scripts into tD directory...
Connected to h1daqnds1
martel run
reading data at start_time:  1453573090
reading data at start_time:  1453573550
reading data at start_time:  1453573950
reading data at start_time:  1453574260
reading data at start_time:  1453574700
reading data at start_time:  1453575050
reading data at start_time:  1453575167
reading data at start_time:  1453575840
reading data at start_time:  1453576170
Ratios: -0.4588903912882054 -0.46880057152484483
writing nds2 data to files
finishing writing
Background Values:
bg1 =        9.720121; Background of TX when WS is at TX
bg2 =        4.686352; Background of WS when WS is at TX
bg3 =        9.770692; Background of TX when WS is at RX
bg4 =        4.628189; Background of WS when WS is at RX
bg5 =        9.797052; Background of TX
bg6 =        0.801247; Background of RX

The uncertainty reported below are Relative Standard Deviation in percent 

Intermediate Ratios
RatioWS_TX_it      = -0.458890;
RatioWS_TX_ot      = -0.468801;
RatioWS_TX_ir      = -0.453881;
RatioWS_TX_or      = -0.463503;
RatioWS_TX_it_unc  = 0.073150;
RatioWS_TX_ot_unc  = 0.076593;
RatioWS_TX_ir_unc  = 0.078168;
RatioWS_TX_or_unc  = 0.089042;
Optical Efficiency
OE_Inner_beam                      = 0.989262;
OE_Outer_beam                      = 0.989063;
Weighted_Optical_Efficiency        = 0.989162;

OE_Inner_beam_unc                  = 0.049361;
OE_Outer_beam_unc                  = 0.054133;
Weighted_Optical_Efficiency_unc    = 0.073259;

Martel Voltage fit:
Gradient      = 1636.767509;
Intercept     = 0.537748;


 Power Imbalance = 0.978861;

Endstation Power sensors to WS ratios::
Ratio_WS_TX                        = -1.077945;
Ratio_WS_RX                        = -1.393587;

Ratio_WS_TX_unc                    = 0.045600;
Ratio_WS_RX_unc                    = 0.039824;

=============================================================
============= Values for Force Coefficients =================
=============================================================

Key Pcal Values :
GS           =      -5.135100; Gold Standard Value in (V/W)             
WS           =      -4.701786; Working Standard Value             

costheta     =      0.988362; Angle of incidence
c            =      299792458.000000; Speed of Light
             
End Station Values : 
TXWS         =        -1.077945; Tx to WS Rel responsivity (V/V)
sigma_TXWS   =        0.000492; Uncertainity of Tx to WS Rel responsivity (V/V)
RXWS         =        -1.393587; Rx to WS Rel responsivity (V/V)
sigma_RXWS   =        0.000555; Uncertainity of Rx to WS Rel responsivity (V/V)

e            =        0.989162; Optical Efficiency
sigma_e      =        0.000725; Uncertainity in Optical Efficiency

Martel Voltage fit : 
Martel_gradient         =        1636.767509; Martel to output channel (C/V)
Martel_intercept   =        0.537748; Intercept of fit of     Martel to output (C/V)

Power Loss Apportion : 
beta          =        0.998895; Ratio between input and output (Beta)  
E_T          =        0.994017; TX Optical efficiency 
sigma_E_T          =        0.000364; Uncertainity in TX Optical efficiency 
E_R          =        0.995117; RX Optical Efficiency 
sigma_E_R          =        0.000365; Uncertainity in RX Optical efficiency 

Force Coefficients : 
FC_TxPD          =        7.900822e-13; TxPD Force Coefficient 
FC_RxPD          =        6.178276e-13; RxPD Force Coefficient 
sigma_FC_TxPD          =        4.646331e-16; TxPD Force Coefficient 
sigma_FC_RxPD          =        3.364222e-16; RxPD Force Coefficient 
data written to ../../measurements/LHO_EndX/tD20260127/

 

Images attached to this report
Non-image files attached to this report
LHO General
ibrahim.abouelfettouh@LIGO.ORG - posted 16:44, Tuesday 27 January 2026 (88923)
OPS Day Shift Summary

TITLE: 01/28 Day Shift: 1530-0030 UTC (0730-1630 PST), all times posted in UTC
STATE of H1: Planned Engineering
INCOMING OPERATOR: None
SHIFT SUMMARY:

IFO is in IDLE for PLANNED MAINTENANCE

Good progress on activities today.

Other:

LOG:

Start Time System Name Location Lazer_Haz Task Time End
22:49 SAF LVEA IS LASER HAZARD LVEA YES LVEA IS LASER HAZARD \u0d26\u0d4d\u0d26\u0d3f(\u239a_\u239a) 16:49
15:44 FAC Nellie LVEA Y Technical Cleaning 17:06
15:51 SUS Betsy LVEA Y BSC2 Inspection 17:51
15:51 FAC Randy LVEA Y BSC2 Inspection 16:22
16:01 FAC Kim LVEA Y Technical Cleaning 17:06
16:33 FAC Richard LVEA Y BSC2 Inspection 17:07
16:33 FAC Randy LVEA Y BSC2 Inspection 23:04
16:42 PCAL Tony, Dripta PCAL Lab N PCAL Meas. 17:13
17:10 FAC Eric, Chris EX, EY, MX, MY N (YES EX) Air Handler and HVAC Maintenance 18:28
17:14 PCAL Tony, Dripta EX Y PCAL Measurement 19:17
17:16 EE Fil LVEA Y Moving electronics by HAM6 20:21
17:33 ISC Jennie LVEA Y Turning on light pipe 17:35
18:06 FAC Kim, Nellie LVEA Y Technical Cleaning 18:44
18:08 SUS Rahul LVEA Y HAM7 OPO 18:31
18:14 TCS Matt, Sophie JOAT/Vac-Prep Lab N CHETA 15:14
19:05 EE Marc HAM1 Y EOM Electronics 20:11
19:06 EE Daniel LVEA Y HAM6 Electronics 20:11
19:07 OPS Oli LVEA Y Reminding Daniel about a meeting 20:21
19:07 COC Masayuki, Jennie LVEA Y HAM1 EOM 20:45
19:08 SUS JAson LVEA Y HAM1 EOM 20:46
21:08 EE Fil LVEA Y HAM6 Electronics 23:06
21:11 PCAL Tony, Dripta EX Y PCAL Meas. 01:11
21:37 SUS Sheila, Rahul LVEA Y HAM7 22:48
21:45 COC Elenna, Keita Optics Lab N EOM 00:34
22:05 SUS-FAC Travis, Jim, Betsy, Gerardo, Tyler, Randy LVEA Y BSC2 Inspection 23:04
22:10 COC Masayuki, Jason LVEA Y HAM1 JAC 00:07
22:13 TCS Marc, Jennie Vac-Prep/JOAT Lab N CHETA Lable Table Cable 23:59
00:41 EE Marc LVEA Y EOM Reconnection 01:41

 

H1 SUS (SQZ)
jeffrey.kissel@LIGO.ORG - posted 16:09, Tuesday 27 January 2026 (88921)
Dramatic Improvement in H1SUSOPO TFs after Adjusting Cable Dressing; Still Some Work Tho
J. Kissel

Took a set of TFs after Rahul and Sheila re-dressed the cables surrounding the H1SUSOPO (LHO:88920). The TFs -- especially Y to Y look a *lot* better with the higher frequency modes re-aligning with historical measurements and the model. There's still some mode splitting in the lowest mode, that I suspect is the transverse/vertical/yaw system not quite yet as soft as it used to was. Rahul mentions they did *not* address the cables that were zip-tied to the H3/V3 spring post so that could be it.

We'll discuss and game plan more with the crew tomorrow.

Data templates saved here:
    /ligo/svncommon/SusSVN/sus/trunk/OPOS/H1/OPO/SAGM1/Data
        2026-01-27_2316UTC_H1SUSOPO_M1_WhiteNoise_L_0p02to50Hz.xml
        2026-01-27_2316UTC_H1SUSOPO_M1_WhiteNoise_P_0p02to50Hz.xml
        2026-01-27_2316UTC_H1SUSOPO_M1_WhiteNoise_R_0p02to50Hz.xml
        2026-01-27_2316UTC_H1SUSOPO_M1_WhiteNoise_T_0p02to50Hz.xml
        2026-01-27_2316UTC_H1SUSOPO_M1_WhiteNoise_V_0p02to50Hz.xml
        2026-01-27_2316UTC_H1SUSOPO_M1_WhiteNoise_Y_0p02to50Hz.xml
Again ran in the configuration where only the DOF being driven was undamped.
Non-image files attached to this report
H1 CDS (ISC)
filiberto.clara@LIGO.ORG - posted 16:05, Tuesday 27 January 2026 (88922)
Field Racks ISC-R5 and ISC-R6

WP 12991
WP 12994
D1200196 ISC-R5 Layout
D2400300 - ISC-R6 Layout
D1900511 - ISC/SQZ Wiring Diagram

In preparation for the installation of BHD, the following work was done to the HAM6 field racks:

1. ISC-R3 is now on its own set of power supplies for ±18V
2. ISC-R5 and ISC-R6 share a set of power supplies for ±18V
3. ISC-R3, ISC-R5, and ISC-R6 share a set of power supplies for ±24V
4. ISC-R5 was updated to D1200196-v15
5. ISC-R6 was updated to D2400300-v1

Racks are not complete. Missing electronics will be installed when available.

F. Clara, D. Sigg

H1 CDS
jonathan.hanks@LIGO.ORG - posted 15:45, Tuesday 27 January 2026 (88919)
WP 12998 cont Installing the new VM cluster

Test stand log book entries that document the setup and testing prior to production

Physical layout

The following components are racked together in rack 12.

  1. sw-msr-pve0 - switch that connects the nodes to each other and to the core.  It runs the internal cluster traffic, and contains the links to the outside world.
    1. Connected to the core via a lag.  I have spare ports in both the core and the switch so that I can increase the bandwidth if needed
  2. pve-node[0,1,2] - the nodes

Basic setup

When I updated the ipmi address in the bios I also did the install of the proxmox nodes.  I follow the basic routine in reworking the proxmox setup for pve-node0.

Repeat this for pve-node1 & 2, incrementing the ip addresses.

Cluster network configuration creation

Configured the niccluster0 interface on each node

Did the same on each node, and a ping test.

Cluster creation

On pve-node0 go to the datacenter / cluster and click on create cluster

Then on the other nodes to to datacenter / cluster and click join cluster

Support subscription activation and updates

Now that the basic pieces are in place and will not need a reinstall, it is time to enable the subscription on each node.

Go to each node to the subscription section and upload the subscription key.

Now run updates against the enterprise repo and reboot each machine.

Configure the ceph network

Repeat for all nodes

Install Ceph

Go to datacenter / ceph page.  When prompted, select install ceph

Clean up disks

We had used these machines for other testing in the test stand, we will go through and clean up the disks prior to use.

This was done on /dev/sdc and /dev/sdd on the systems

Create the Ceph OSD (Object Storage Deamon)

On each machine go to ceph/OSD

Repeat for /dev/sdd.

After a minute they should show up on the ui.

Add more Ceph monitors

Add pve-node1 and pve-node2 as ceph monitors and managers.

Add a Ceph pool

pve-node0 /ceph / pool

Setting up the VM data links, a bonded bridged network

Go to network / Create / Linux Bond

Create a data bridge, network / Create / Linux Bridge

Do this on each of the nodes.

Notes

When creating VMs we want to connect the network to vmbr1 and specify the vlan tag that should be used as this setup gives us access to more than one vlan.

H1 SUS (SUS)
rahul.kumar@LIGO.ORG - posted 10:59, Tuesday 27 January 2026 - last comment - 08:37, Wednesday 28 January 2026(88917)
HAM7 OPO health check investigation - took fresh pictures (in chamber) for comparison, looking for cable inteferances.

Jeff, Sheila, Rahul

Details about OPO health check issues (Yaw dof. - frequencies are off and unnecessary peak observed) is currently being analyzed - see Jeff's alog 88913.

This morning we discussed about possible cable interferences in OPO.

I went into the chamber and took fresh pictures of the OPO from several angles, focusing on cable routing, cable resting on the OPO etc - please find them attached below. I will compare them with the pictures posted in LHO alog 61643 (by Sheila in 2022) and look for possible culprits (a few of them already).

Moving cables could cause some misalignment, hence we will start doing so once Sheila gives us a green light.  

Images attached to this report
Comments related to this report
rahul.kumar@LIGO.ORG - 15:11, Tuesday 27 January 2026 (88920)

This afternoon Sheila and I went into the chamber and nudged some of the cables away from the OPO - Jeff will re-check the TF measurements to look for any improvements. 

There is a cable connector sitting on the OPO (which is a new addition to the OPO). I lifted that cable connector and then Sheila looked for alignment shifts - which she confirmed. For now we left the cable connector at the same spot on the OPO. We will think of moving it away after Jeff's results.

Sheila also found some changes in the beam alignment since last week - not sure if this is due to our work (AOSEM re-centered LHO alog 88910) from yesterday - although centering aosem-flag should not change the mechanical alignment. 

corey.gray@LIGO.ORG - 08:37, Wednesday 28 January 2026 (88938)EPO

EPO tagged

H1 ISC (INS, ISC)
keita.kawabe@LIGO.ORG - posted 10:42, Saturday 24 January 2026 - last comment - 08:35, Wednesday 28 January 2026(88884)
JAC EOM update Friday Jan/23 (MattT, Mitch, Keita)

10-32x0.375" SHCS that was blocking the access to one 1/4-20 screw was replaced with a low profile 10-32 SHCS.

"Issue 2" in alog 88862 was solved.

See picture, Mitch found a 10-32x0.5" SHCS with a low profile head. 0.5" seemed to be OK in that it's not too long, but we used two washers to make sure that the scrwe doesn't bottom out.

Images attached to this report
Comments related to this report
keita.kawabe@LIGO.ORG - 14:16, Saturday 24 January 2026 (88886)

EOM crystal mounting practice part 2 (with a remote help from Michael)

Summary:

  1. "Laxen method" (no gap between the front plate and the input side, big gap for the output side) was repeated again with an extra caution (see below), no visible gap between the alumina piece and the electrode (with a help of flashlight), alumina doesn't slip out.
  2.  "Appert method" (even gaps for the input and the output) was tried twice, no visible gap between the alumina piece and the electrode, alumina doesn't slip out. 
    1. During Appert method tests we have found that the output side plate might be slightly warped.
  3. RF return dips were measured for all three of the above (one Laxen and two Appert mounting method), they were consistent regardless of the mounting method and were consistently higher than nominal with the alumina. (No RTP yet). It goes progressively worse as the frequency goes up. Michael told "The resonant dip needs to sweep across the desired frequency."
    1. Lower two frequencies (9.1MHz and 24.08MHz) look reasonable in that the nominal frequency is inside the observed dip.
    2. 45.5MHz dip is just barely on the shallow part of the dip curve.
    3. 118MHz is the worst, the nominal frequency is totally out of the dip (1MHz off).
  4. Michael suggested that the capacitance for the elctrorode-crystal is too small but we (Matt and I) couldn't see any light coming through the supposed gap.
  5. Michael also suggested that the windings of the inductor coils might have been bent (got looser) during shipment.
    1. I tested bending the coil windings for 118Mhz inductor so they come closer together and it had a huge impact. I was able to easily come close to a reasonable frequency, but it's no good unless we know that the capacitance for the crystal-electrode is OK.  I haven't changed trim cap nor touched any other frequencies.
  6. I'll measure the peaks without the alumina on Monday. Will discuss further with Michael, Stephen and Gabriele (while Masayuki is traveling to here).

Laxen method test.

In alog 88862 we left the EOM module with the alumina piece mounted using Laxen method (no gap between the input side plate and the front plate, a big gap for the output side).

Shining flashlight into the iput or output aperture in the side plates is useful to see the gap between the electrode plate and the alumina piece, and we found that there was indeed a small gap only on one side (i.e. the "crystal" was pinched at the edge).

I loosened the screws for the face plate and repeated the mounting procedure, but this time being extra careful to tighten the screws by tinier amount (than my previous attempts) at a time while applying a gentle pressure from the top. As soon as I got much tighter than finger-tight, I stopped. This resulted in what was seemingly a good contact between the alumina and the electrode, no light visible between them.

See  nogap.jpg, this is a representative picture of GOOD contact (even though I cannot prove that the contact is really plane-to-plane not just plane-to-one edge of the crystal).

Another picture gap.jpg is an example of BAD contact. It's hard to see but there's no gap at either edges closer to input/output faces, the gap is only in the middle. I don't have a good explanation for this.

Appert method tests.

We also tested Stephen's suggestion to make a gap on both sides of the front plate. This was trickier but doable by using two Allen keys. The third attachment (EOMassembly.jpg) shows the EOM placed on top of the EOM mount parts just for picture AFTER the alumina was mounted. During the mounting process, the face plate is facing down, and two allen keys will tighten two screws with green (or red) arrows in the picture with tiniest rotation at a time. Green, red, green, red, repeat it until it feels reasonably tight but much, much looser than you'll usually do for tight mechanical connection. After this was done, neither Matt nor I were able to undo the screws by finger.

We did this twice, both times no gap between the alumina and the board, and alumina didn't slip out.

Output side plate might be warped?

In the assembly picture, can you see that the gap between the face plate and the output side panel (right on the picture) is uneven, but the gap for the input (left on the picture) is fairly even? I don't think this is an optical illusion. This might be related to the reason why the crystal ALWAYS slips out when the face plate is tightened down to the output side plate, see my alog (88862). Quoting myself, "no matter what we did, the alumina piece (i.e. fake RTP for excercize) slid out of the assembly but only after tightening the screws". Maybe it's the output side plate.

Reflection measurement.

For each of the above three practices (one with Laxen method, two with Appert method), S11 coefficient was measured for all four ports.

What we found was that all four reflection dips were higher than they are supposed to be. According to Michael, alumina should give us similar results to RTP. I don't list results for all three sets (3x4=12 numbers) because numbers were pretty consistent across the sets, maybe give or take 10kHz or so. 

Nominal LHO/LLO (MHz) 9.100230 / 9.099055 24.078360 / 24.078 45.50115 / 45.495275 118.30299/118.287715
Measured (representative number) (MHz) ~9.17 ~24.10 ~46.05 ~119.8

In the attached pictures, green line is roughly where the center should be. 9.1 and 24.08 look reasonable to me. Not sure about 45.5MHz, it's 450kHz off. 118.3MHz is totally, totally off.

As I wrote in the summary, I tried bending the coil windings for the 118MHz (bendandsqueeze.jpg) because it was the worst but also because it was the one with the loosest of all four coils (118MHzWinding.jpg), and it had a huge effect. With just a few rounds of bending/squeezing I was able to go down to 118.53MHz (afterbending_118MHz.jpg). I could have passed 118.3 and gone to the other side easily but I stopped there.

Images attached to this comment
keita.kawabe@LIGO.ORG - 14:10, Saturday 24 January 2026 (88887)

Just in case somebody else must do this, here's what I did to measure S11 (reflection coefficient). 

If you go to the optics lab, everything is already set up like in the attached cartoon except that the dirty cable is removed from the coupler and placed on top of the optics table. You might still do the calibration again (because we turned off the analyzer at the end of the day and I cannot remember if the calibration results are kept in the analyzer). Remember that EOM is class A but your cables are dirty (even though we wiped the connectors of the dirty cable using q-tips and IPA). We're using one sacrificial SMA elbow that used to be class A to connect your dirty cable to the EOM.

Anyway, calibration. Set the frequency range to whatever you want but make sure that it covers the frequency range of main interest, like at least 9MHz to 125MHz or so while performing S11 calibration.

Connect the BNC of the dirty cable to the INPUT connector of the directional coupler, like in the attached cartoon.

Press "cal" button and select S11 calibration. Don't connect anything to the SMA of the dirty cable and press "Open" button. Next attach a hand-made short circuit plug to the dirty cable  via BNC male to SMA female connector. Press "Short". Then connect a 50Ohm SMA terminator to the dirty cable via SMA barrel. Press "Load". Then press "Done".

Now you're done with calibration. Press "Measure" and make sure that you're measuring S11.

Clean the SMA with IPA and q-tip again. Connect the dirty cable to the elbow, and the elbow to the EOM. Set the frequency range to whatever you want. That's it.

Images attached to this comment
keita.kawabe@LIGO.ORG - 16:25, Monday 26 January 2026 (88892)

Quick Monday update.

I  measured S11 coeff without the crystal/alumina but with the front panel.

Reflection dips with/without alumina are:

~9.17/9.192 ~24.10/24.214 ~46.05/47.106 ~118.53/122.736

So the frequencies are consistently higher without the crystal/alumina.

corey.gray@LIGO.ORG - 08:35, Wednesday 28 January 2026 (88937)EPO

EPO tagged

LHO VE
jordan.vanosky@LIGO.ORG - posted 16:33, Friday 23 January 2026 - last comment - 08:33, Wednesday 28 January 2026(88876)
Removal of the Relay Tube Viewport Assembly

In prep for HAM7 closeout, the temporary viewport assembly was removed from the HAM5 relay tube port. RV-1 was closed, and the volume vented with viewport covers still installed, with dry N2. I monitored the corner pressure (PT-120B) during venting, to make sure there were no leaks through the gate valve. No change in pressure, so I continued with viewport removal.

Viewport was removed first, then the pump-out tee. The mitered spool piece and bellows assembly was installed on HAM5 side. Lines were marked across the relay tube assembly prior to removal, so the install orientation remained the same. 

The ported spool piece will be installed next week during Laser Safe conditions. Bellows flanges were covered with foil for protection.

Images attached to this report
Comments related to this report
corey.gray@LIGO.ORG - 08:33, Wednesday 28 January 2026 (88936)EPO

EPO Tagged.

H1 SQZ (SQZ)
karmeng.kwan@LIGO.ORG - posted 16:33, Thursday 22 January 2026 - last comment - 08:30, Wednesday 28 January 2026(88859)
HAM7 and SQZT7 iris photos

[Sheila, Karmeng]

We took a bunch of photos on HAM7 and SQZT7 today, the IR-green coalignment is fixed. 

IR-green coalignment: on the iris between ZM3 and FC1 (before and after) and after AM3 (green and red overlap)

Beam position for all 3 irises placed in HAM7:

Iris 1 IR position on the iris placed between ZM1 and ZM2.

Iris 2 IR+green position on the iris placed between ZM3 and FC1.

Iris 3 IR position on the iris placed between BM4 and ZM4, with "RL" on the Thorlabs IR card placed on the iris as a reference to estimate the deviation from the center of the iris.

For 2 irises placed on SQZT7 HD path:

Iris 1 IR position on iris1 on SQZT7.

Iris 2 IR position on iris2 on SQZT7.

We also checked the IR on HAM7 QPDs path, the IR is off centered on the lens (seen from both front and back). This was roughly centered, and will be fine tuned with the picos.

Images attached to this report
Comments related to this report
corey.gray@LIGO.ORG - 08:30, Wednesday 28 January 2026 (88935)EPO

EPO tagged.

H1 IOO (IOO)
rahul.kumar@LIGO.ORG - posted 13:04, Wednesday 21 January 2026 - last comment - 09:41, Wednesday 28 January 2026(88834)
HAM1 update - JAC damper

Jason. JennieW, Rahul

This morning we added the damper parts to the JAC in HAM1 chamber - see picture attached. The cables were re-routed slightly so that they don't interfere with the damper.

I have finger tightened the screws of the damper for now - since no torque spec was provided and we were worried that tightening them too much might affect its position/angle.

Images attached to this report
Comments related to this report
corey.gray@LIGO.ORG - 08:27, Wednesday 28 January 2026 (88934)EPO

EPO-tagged.

jason.oberling@LIGO.ORG - 09:41, Wednesday 28 January 2026 (88941)

Masayuki and I fully tightened the JAC body mode dampers yesterday.  We were only able to get the screws ~1/2 turn past finger-tight before we could no longer tighten them.  No changes in JAC alignment were observed while we were doing this.

H1 SUS (SUS)
ryan.crouch@LIGO.ORG - posted 11:44, Wednesday 21 January 2026 - last comment - 08:25, Wednesday 28 January 2026(88828)
2nd HXDS received from LLO

Yesterday I picked up the shipment from LLO contain the 2nd HXDS (first HXDS shipment alog87998) and related ASSEYs and brought it to the Triples lab. 

Uwrapping and inspecting was uneventful, the zip ties were intact, the shock pads untripped and the humidity indicator was unchanged in color. The outer (front, back) and inner (front, back) bags were in good condition, unwrapping the suspension I found no play with the blades.  All the nuts and dowel pins were tight and well seated, the ICS looks good except for it seems to be missing the HDS Intermediate Mass Fixture (D2000230-V1, s/n 08). The part is scribed as V1, on the dcc there's a V2 with two added 8-32 helicoils taps that, based on D1900352 which uses V2, I should be able to see from the front and I don't, so this is a V1 plate and not an incorrectly scribed V2. I believe these two missing 8-32 holes are where we will attach the BOSEM Mounting plate (D2000257). The first HXDS we received in November had the V2 plate. We may have to do a small rework to update it to V2, or have LLO send the V2 part if possible.

Images attached to this report
Comments related to this report
corey.gray@LIGO.ORG - 08:25, Wednesday 28 January 2026 (88933)EPO

EPO tagging

Displaying reports 2581-2600 of 88977.Go to page Start 126 127 128 129 130 131 132 133 134 End