Displaying reports 2601-2620 of 88977.Go to page Start 127 128 129 130 131 132 133 134 135 End
Reports until 10:59, Tuesday 27 January 2026
H1 SUS (SUS)
rahul.kumar@LIGO.ORG - posted 10:59, Tuesday 27 January 2026 - last comment - 08:37, Wednesday 28 January 2026(88917)
HAM7 OPO health check investigation - took fresh pictures (in chamber) for comparison, looking for cable inteferances.

Jeff, Sheila, Rahul

Details about OPO health check issues (Yaw dof. - frequencies are off and unnecessary peak observed) is currently being analyzed - see Jeff's alog 88913.

This morning we discussed about possible cable interferences in OPO.

I went into the chamber and took fresh pictures of the OPO from several angles, focusing on cable routing, cable resting on the OPO etc - please find them attached below. I will compare them with the pictures posted in LHO alog 61643 (by Sheila in 2022) and look for possible culprits (a few of them already).

Moving cables could cause some misalignment, hence we will start doing so once Sheila gives us a green light.  

Images attached to this report
Comments related to this report
rahul.kumar@LIGO.ORG - 15:11, Tuesday 27 January 2026 (88920)

This afternoon Sheila and I went into the chamber and nudged some of the cables away from the OPO - Jeff will re-check the TF measurements to look for any improvements. 

There is a cable connector sitting on the OPO (which is a new addition to the OPO). I lifted that cable connector and then Sheila looked for alignment shifts - which she confirmed. For now we left the cable connector at the same spot on the OPO. We will think of moving it away after Jeff's results.

Sheila also found some changes in the beam alignment since last week - not sure if this is due to our work (AOSEM re-centered LHO alog 88910) from yesterday - although centering aosem-flag should not change the mechanical alignment. 

corey.gray@LIGO.ORG - 08:37, Wednesday 28 January 2026 (88938)EPO

EPO tagged

H1 SUS (SQZ, SUS)
jeffrey.kissel@LIGO.ORG - posted 10:48, Tuesday 27 January 2026 (88913)
H1SUSOPOS TFs post-OPO Crystal Swap / Translation Stage Improve -- Something Quite Off
J. Kissel, R. Kumar, B. Weaver, S. Dywer

Context
After the SQZ team felt done with OPOS suspension the re-install of the OPO (with an upgraded translation stage) we're following up on
    - Ryan's first look of the suspension's health (LHO:88851) 
    - After restoring the OPOS to normal control system configuration (LHO:88872) 
    - After recentering the AOSEMs (LHO:88910)

Measurement
I gathered more standard health check TFs. In doing so, I spruced up the excitation frequency response and data gathering templates to ensure good coherence. I also ran the TFs with all the damping loops besides the excitation degree of freedom ON to reduce incoherent motion from cross-coupling. The refreshed templates are 
    /ligo/svncommon/SusSVN/sus/trunk/OPOS/H1/OPO/SAGM1/Data
        2026-01-26_2054UTC_H1SUSOPO_M1_WhiteNoise_L_0p02to50Hz.xml
        2026-01-26_2054UTC_H1SUSOPO_M1_WhiteNoise_P_0p02to50Hz.xml
        2026-01-26_2054UTC_H1SUSOPO_M1_WhiteNoise_R_0p02to50Hz.xml
        2026-01-26_2054UTC_H1SUSOPO_M1_WhiteNoise_T_0p02to50Hz.xml
        2026-01-26_2054UTC_H1SUSOPO_M1_WhiteNoise_V_0p02to50Hz.xml
        2026-01-26_2054UTC_H1SUSOPO_M1_WhiteNoise_Y_0p02to50Hz.xml


Results
Attached is comparison of 
    - the opos dynamical model (Equations of Motion matrices: ssmake_voposus.m rev 12322; parameter set: oposopt_h1susopo_fit rev 12322)
    - the most recent, best at-vacuum, measurement of L1's OPOS
    - the last, best, at-vacuum measurement of H1's OPO prior to moving from HAM6 to HAM7
    - the last, bext, at-vacuum measurement of H1's OPO after moving to HAM7 (with a payload almost identical to what's installed now)
    - yesterday's measurement described above.

Focusing on page 6 first, one can clearly see that YAW to YAW transfer function is wildly different, implying a significant change to the dynamics of the suspension.
There's more supporting (but less signficant) evidence in 
    - pages 1 and 2 which shows and increase in the primary L / T resonance from 1.25 Hz to a split 1.32 Hz / 1.39 Hz
    - pages 1 thru 6 (all diagonal elements of the TF matrix) and pages 7 thru 20 (most off-diagonal elements) all showing a huge (tho incoherent) resonance in yaw at 4.98 Hz that was not there before
    - Nominally an oversight in the design, the expected large V to Y coupling looks quite impeded.

Discussion
After conversing with Sheila about what might have changed, or what might be impacting the dynamics, she reviews the changes:
    - The OPO cavity assembly (D1500296) has only a few changes -- the translation stage within is new, and there are now thin remote-control cables coming out of the assembly that weren't present before.
    - Those new remote control cables have been bundled into a pre-existing bundle, potentially making the system stiffer. We guess that this is the likely culprit of our problems.
    - Further the re-placement of the OPO assembly on the OPOS was not precise. It's plausible that the physical location of the cavity is now *slightly* different position, *potentially* changing the balance and mass ratio of how much moving mass is in which translational DOF. Maybe the source of L / T resonance shifts, but I doubt it. 

Also, conversing with Betsy and Rahul about the state of cables they found while centering the OSEMs:
    - They see a collection of cables (OSEM and SQZ) on the "far" (+Y) H3/V3 side of the OPOS that are resting on the platform without a good, dressed, soft connection between the platform and where the cable stress is relieved on the base.

Conclusion

We need to address / free-up the dynamics of this suspension before closing up the chamber.
Non-image files attached to this report
H1 IOO (ISC, OpsInfo, SEI)
jennifer.wright@LIGO.ORG - posted 10:42, Tuesday 27 January 2026 (88916)
Restored sliders on IMC SUS to December 3rd state

Jennie W, Jason O, Sheila D, Masayuki N,

 

Following Jim bringing HAM3 HEPI online (alog #88909) and isolating HAM3 ISI.

Jason and I restored the MC1, 2 and 3 sliders to their position on December 3rd during a lock when the mode-cleaner was locked with 2W input, HAM2 and 3 ISO Gain was , HAM2 and 3 ISI Guardian was set to 'isolated' and 2 and 3 HEPI guardian was set to 'RoBUST ISOLATED'.

This lock state for the IMC Guardian is 100. 

 

Before any adjustments today, we had 45 dB whitening gain on MC2 trans, and 91% of the power was in the 00 mode. This gave us 46 counts on MC2 trans nsum.

After HEPI, ISI, and suspensions are restored, we have mostly 10 mode, with 17.9 counts on MC2 trans sum, still 45 dB whitening gain.

I lowered the whitening gain to 30 dB to restore us to the normal whitening gain.

If we restore the alignment so that 90% of the power is in the 00 mode again, we should have 8.2 counts MC2 trans nsum

Images attached to this report
LHO General
eric.otterman@LIGO.ORG - posted 10:36, Tuesday 27 January 2026 (88915)
HVAC fan bearings greased
All fan bearings at Corner, Mids and Ends were greased this morning. 
LHO VE
david.barker@LIGO.ORG - posted 10:13, Tuesday 27 January 2026 (88912)
Tue CP1 Fill

Tue Jan 27 10:06:26 2026 INFO: Fill completed in 6min 22secs

 

Images attached to this report
H1 SUS (SUS)
rahul.kumar@LIGO.ORG - posted 09:50, Tuesday 27 January 2026 (88910)
HAM7 work - OPO AOSEMs (H1, H2, H3) re-centered.

Karmeng, Betsy, Jeff, Rahul

Following the recommendation given in LHO alog 88872, yesterday (01/26/2026, Monday) we went into HAM7 chamber and re-centered the three horizontal AOSEMs (H1, H2 and H3) as best as we could. All three AOSEM counts (raw inmons) are now between 11-15k. 

Next, Jeff will re-take the transfer function measurements and confirm if OPO is healthy.

Also, Sheila et al will re-confirm if the beam is well aligned with other suspension in HAM7 chamber.

OPO is currently unlocked and suspended. 

H1 SEI
jim.warner@LIGO.ORG - posted 09:48, Tuesday 27 January 2026 (88909)
Current seismic state in the corner

Because there was some confusion about the mechanical states in the corner station, I'm posting a summary of things as they stand today. The only HEPIs that are locked are HAM1,2 and BSC2, and HEPI Isolation are still bypassed. The white board in the control room says HAM1-4 are locked, this is not true. I have re-enabled the isolation loops for HAM3 HEPI (set H1:HPI-HAM3_ISO_GAIN to 1) and set HAM3  SEI back to ISOLATED. HAM1&2 HEPI are still bypassed. HAM1 & 7 ISI are also still locked.

HAM1,2, BSC2 HEPI - LOCKED, BYPASSED

HAM1,7 ISI - LOCKED

Everything else should be able to be run as normal.

H1 CDS
david.barker@LIGO.ORG - posted 09:03, Tuesday 27 January 2026 (88907)
Move cdswiki server to make space for new cluster

WP12997 Jonathan, Erik, Dave:

The cdswiki server, which actually is now just our CDS Apache web server after the wiki moved to GC, was physically moved from MSR-RACK12 [U17,18] over the MSR-RACK11.

We decided to put it where the unpowered netmonitor machine was in U16,17. The netmonitor machine was removed and is now in H2 storage.

cdswiki has only a 10.20 ethernet cable connection, I used a shorter 6-footer (E5B-006-0001) which was dangling in the rack.

LHO General
ibrahim.abouelfettouh@LIGO.ORG - posted 07:55, Tuesday 27 January 2026 - last comment - 10:09, Tuesday 27 January 2026(88905)
OPS Day Shift Start

TITLE: 01/27 Day Shift: 1530-0030 UTC (0730-1630 PST), all times posted in UTC
STATE of H1: Planned Engineering
OUTGOING OPERATOR: None
CURRENT ENVIRONMENT:
    SEI_ENV state: MAINTENANCE
    Wind: 4mph Gusts, 3mph 3min avg
    Primary useism: 0.03 μm/s
    Secondary useism: 0.33 μm/s 
QUICK SUMMARY:

IFO is in IDLE due to PLANNED MAINTENANCE

Work continues on in-chamber JAC alignment and EOM work is continuing (RTP installation planned for today). Work is being done to close out HAM7.

Comments related to this report
david.barker@LIGO.ORG - 10:09, Tuesday 27 January 2026 (88911)

Fire pump alarms bypassed for next 4 hours while churn testing is ongoing.

H1 CDS
david.barker@LIGO.ORG - posted 07:53, Tuesday 27 January 2026 - last comment - 08:37, Tuesday 27 January 2026(88904)
VACSTAT alarms for EY BY Ion Pump Issues 00:09:33 Tue 27 Jan 2026

VACSTAT detected a gas release at EY originating at the EY BT Ion Pump and rapidly propagating to EY. Cell phone alarms were sent to team-VAC.

Gerardo determined that the Y2-8 ion pump turned off for 1 min 41 seconds and then recovered.

 

Images attached to this report
Comments related to this report
david.barker@LIGO.ORG - 08:37, Tuesday 27 January 2026 (88906)

vacstat_ioc.service was restarted at 07:57 to reset this alarm.

H1 CDS (CDS)
erik.vonreis@LIGO.ORG - posted 06:51, Tuesday 27 January 2026 (88903)
Workstations updated

Workstations were updated and rebooted.  This was an OS packages update.  Conda packages were not updated.

H1 ISC (INS, ISC)
keita.kawabe@LIGO.ORG - posted 18:07, Monday 26 January 2026 - last comment - 13:06, Tuesday 27 January 2026(88900)
JAC EOM Monday (Elenna, Keita, with remote help from Stephen, Michael, Matt and Gabriele)

Nothing wrong with our previous reflection dip measurements with alumina.

We (MichaelL, StephenA, MattH, Gabriele, Elenna and myself) had a meeting in the morning. 

Looking at the "with the alumina" reflection screen shots, Michael didn't see any serious problem so we decided that the electrode-crystal-face plate capacitance is OK. We won't worry about that, we'll just make sure that there's no visible gap.

Third mounting method ("in-between") was proposed and tested.

Stephen proposed an in-between method where we use washers between the input side plate and the front plate (bottom of three_methods.png cartoon). After the washer contacts the face plate AND the input side plate, screws are gently tightened in a balanced manner like in Appert method.  (In a retrospect this is not that different from Laxen method except the way screws are tightened and that the input side plate contacts with the face plate at two points.) 

We first tried to use a presicion thickness shim washer for 1/4-20 screws but I didn't like that they're too big. We ended up using smaller stamped washers that is 0.039" or 0.99mm thick (according to the caliper). That's not flat but seems OK to me.

This in-between method worked in that it was doable and gave us a reasonable reflection dips.

Mechanical stability test of Appert method and in-between method. The latter is better, we'll use that for the real RTP.

My original concern for the original Appert method (middle of three_methods.png cartoon) was that somehow the screw gets loose during transport or after a large change in the in-chamber temperature and the tuning will be off. Upon hearing this, Stephen proposed a test to loosen one screw and see if the tuning changes. We performed this test for both Stephen method and the in-between method. (Spoiler: yes.) We measured all four dip frequencies right after the alumina piece was mounted but only tracked the frequency change of 118MHz peak.

Loosening one screw changes the frequency, but the frequency change for the in-between method is an order of magnitude smaller (10 to 30kHz) than the original Appert method (300kHz) when the FWHM (or rather the width between the points where reflection is 6dB larger than the bottom of the dip) is about 70kHz or so. This is just one trial but I'm convinced that in-between method (or maybe Laxen method too though we haven't tried) is better, so that's what we'll do for the real crystal.

We only loosened the screws on the output side for both mounting methods. 

  Initial four frequencies Shaking? Loosen 1st screw Loosen 2nd screw
In-between method

9.142, 24.110, 45.972, somewhat

smaller than 118.214kHz

changed to 118.214kHz, unclear why.

(Something like 10k or 20kHz change,

couldn't cause another change by gentle tapping.)

118.214 -> 118.240

(+26kHz)

118.240 -> 118.251

(+11kHz)

Original Appert method 9.14685, 24.107, 46.066, 118.322

118.322 -> 118.592, caused by gentle tapping.

(+270kHz)

118.592 -> 118.876

(+284kHz)

118.876 -> noman's land

(>1MHz)

Shake and it will shift, we need to measure it again in chamber?

It's good to know that the in-between method can somewhat withstand the loosening of the second screw (because the tighter screws still support the face plate). However, it's disappointing to find that the assembly is susceptible to shaking.

In the in-between method, we couldn't record the initial 118MHz dip because it jumped up by 10kHz or so in front of our eyes when we were moving around the table. Not sure what happened but I assumed that it was some kind of shaking. However, I gently tapped the front and side plates and couldn't cause another shift.

In the original Appert method, since we knew something could happen, I tapped the front and side plates and there was a huge jump. See the difference between initial_118.jpg and taptap_118.jpg.

Even though we'll use in-between mounting method, it's plausible that the frequency shifts during transport or when the EOM lands on the ISI surface. I'm thinking we'll have to measure it in situ after everything is tuned in the lab.

What's to come tomorrow.

We'll install RTP and tune. Before doing that, though, I'll discuss inserting indium foil between the crystal and the front plate with Masayuki. Michael suggested that (and even between the crystal and the electrode, though that would be tricky) today, Masayuki and I talked about the possibility briefly last week, it just sounds like a good thing as a buffer to absorb gaps here and there.

Other things.

In the previous alog (88886) in one of the pictures (gap.jpg), there was a time when it looked as if the circuit board was slightly bowed. We took a picture of the electrode today (electrode_contactpoint.jpg) and it looks as if the electrode is more abraded close to the outside edge of the crystal, so maybe the board bowing is real.

 

 

Images attached to this report
Comments related to this report
keita.kawabe@LIGO.ORG - 13:06, Tuesday 27 January 2026 (88918)

Why (change in) the gap might matter.

Gabrilele asked me why a tiny gap matters so I made a quick calculation.

Suppose that we can ignore the edge effect at the edge of the electrode for convenience, we can replace the 4x4x40mm crystal with an infinitely wide and long crystal that is 4mm thick, and replace the capacitance with the capacitance per area.

In the attached, the electrode, the crystal and the face plate are all inifnitely larger in a plane orthogonal to the surface of my log book. Thickness of the crystal is d (4mm). There's a gap of delta between the electrode and the crystal, and there's no gap between the crystal and the face plate (but it's not important where exactly the gap is).

Under such a configuration, if you do the math, the capacitance per area is equal to the no-gap capacitance per area multiplied by 1/(1+epsilon*delta/epsilon_0/d) where epsilon and epsilon_0 are the permittivity of the alumina and vacuum, respectively, and the former is 10 times the latter.

In the end, the capacitance with the gap is a factor of

1/(1+10*delta/4mm)

smaller than without the gap.

The capacitance with a 0.1mm gap is 80% of that without the gap, 0.2mm and it's 67%, 0.3mm (12 thou) and it's 57%. If the gap doesn't change, maybe that's OK. If the gap changes it will change the tuning via capacitance change. There are other effects (like coil winding) but the capacitance change via the gap change cannot be ignored/dismissed.

Images attached to this comment
H1 IOO
jennifer.wright@LIGO.ORG - posted 18:05, Monday 26 January 2026 (88896)
JAC work today

Jennie W, Sheila D, Rahul K

 

Summary:

I guess the summary for yesterday is we improved the input alignment to JAC but are not sure why it was lower relative to last Thursday.

And that we have aligned into the IMC with steering mirrors after JAC on HAM1 and now get TM00 modes flashing on the IMC TRANS camera but are not sure why our on-table references (IMC REFL WFS) and in-chamber iris are not aligned with this beam.


 

Before we went into chamber today we checked the fringes in the JAC cavity transmission to see if we had the same power in the TM00 modes as Friday (when it was ~ 0.15). From the image you can see that the level on the JAC-TRANS_A PD is now around 0.1, and it looks as though the 01 mode could be near the size of the TM00 mode.

This implies the input alignment (which we recovered on Thursday to 0.22) has been drifting.

In chamber Sheila found that the JAC cavoity was locking on a 01 mode (two vertical lobes).

She tried moving the JM1 mirror and found the base was slightly loose in the mount. Not sure if this is enough to really explain the mis-alignment fully.

She tweaked up the alignment of this mirror and I tweaked up the alignment using PSL PZT periscope mirror until the beam went up to 0.22 on the JAC TRANS A PD.

We checked the power in chamber right before the input coupler to JAC and it is now 93 mW.

The power measured after JAC (right before mirror JM2) is 58 mW.

The power measured on IOT2L after the bottom periscope mirror is 44mW.

After continuing tweaks to the input alignment we got 0.28 on the JAC TRANS A PD 0.28 with input alignment changes.


We maximised the power onto the table by moving JM2 and JAC-M3 and looking at the IMC REFL PD.

We have 76mW power after bottom periscope mirror and

 a 0.96 - 1.2 level on MC REFL PD.

Still have 0.28 level on JAC trans out.

We started to notice fringing (see image) on the IMC TRANS camera and on MC2 TRANS QPD NSUM.

I did a quick check of the mode-matching and it looks like our mis-match is now about 11% (for the second highest mode in the scan).

We therefore switched to using these as our metric while we optimised the alignment into the IMC with the same two mirrors JAC_M3 and JM2.

Eventually Sheila and Rahul discovered clipping on the last iris before the beam leaves HAM1 so marked the height with a C clamp and took it out. This was our reference for the original beam into HAM2 before the JAC install was started.

Continued to optimise with these two mirrors.

At the end of the day we placed new iris after output periscope and moved iris on IOT2L in reflection of first table steering mirror to mark the placement of the beam.


Since we still are not aligned to our references on the table - ie. the WFS, the iris placed at the HAM1 output before JAC was installed, we will double check the MC mirrors position relative to our most recent in-air lock and the last in vacuum lock.

Compared to the 19th December 00:25 UTC, the position of MC3 M1 DAMP INMON has increased by 6 uradians in pitch and has not changed in yaw.

Compared to the 19th, the position of MC2 M1 DAMP INMON has decreased by 10 uradians in pitch and has decreased by 1 uradian in yaw.

Compared to the 19th, the position of MC1 M1 DAMP INMON has decreased by 3 uradians in pitch and has increased by 3 uradian in yaw.

Cursors show current values in this ndscope plot.

Jeff also did a check here (alog #88895).

Images attached to this report
H1 TCS
sophie.muusse@LIGO.ORG - posted 18:04, Monday 26 January 2026 - last comment - 10:48, Tuesday 27 January 2026(88902)
CHETA Progress - second table

S Muusse, M. Todd


New QCL unit (0920) has been put in place of original unit (0923) which is malfunctioning (cause unknown). Initial profiling has taken place and L1 focal length is 10% larger than spec.


QCL unit failure summary:

All day on 2026-01-21 we were running the laser at 900mA doing beam profiles and alignment work. No malfunctioning was witnessed and the laser unit was operating as expected, similar to the laser unit we had run in December for a week. Before lasing we set the following limits on the LD and TEC, per the datasheet.

  1. LD current limit was set to 1.05A
  2. LD voltage limit was set to 12.9V
  3. TEC operating temperature was set to 20C

On 2026-01-22 we turned the laser on to do some more beam profiling with the same limit settings as yesterday, but setting the LD current to 1A (forward voltage was around 12.2V) as was done when we originally profiled this laser in September. We were in the middle of setting up for a new beam profiling measurement (alignment showed the beam was fine, as usual) and we blocked the beam with a high power beam dump at the laser head while installing the profiler. Upon removing the beam dump, we noticed no power was coming out of the laser, and then noticed the forward voltage had dropped to around 800mV. We noticed no sounds or smells or any other signs that something had stopped, only sudden lack of light coming from the unit. All other settings were fine, meaning the controller had not faulted and was still outputing 1A LD current and the TEC was maintaining 20C.

We ran the following checks to see if we could remedy the problem, without success.

  1. Checked the cable connection to the laser unit (pins on the laser unit looked fine)
  2. Checked the Laser Controller cable connections (pins in the DSUB connectors looked fine)
  3. We tried a completely new laser controller box and new cable. The settings were similarly set and the same behavior was seen with the forward voltage response to the LD current setpoint.
  4. We tried changing the TEC setpoint to be 25C, and the same behavior was seen with the forward voltage response to the LD current setpoint, and failing to lase as usual.
  5. We used the same cable and laser controller on the previous QCL unit, and it operated as expected --- lasing fine as usua

QCL 0920 profiling summary:

Replaced broken unit with 0920 and confirms it lases as spec'd. We built telescope as modelled but beam profile was 75% of expected beam width at L2. We subsequently profiled the laser output and confirmed QCL output q measured previously by Matt was still correct. We became suspicious of the true focal length of L1. Then we profiled multiple places after L1 and fit a q parameter using a non-linear fit. A plot of this fit is attached. Using these 2 q parameters the focal length of L1 was estimated to be 220mm instead of 200mm as spec. We think this is mostly because L1 focal length stated by manufactorer is for 588nm where the refractive index is almost 3% larger than at 4.6um. Focal length in the model was modified to reflect our estimated f1 which predicted a beam size closer that measured earlier. 
Side note: the scanning slit beam profiler reflects significant amount of 4.6um light which is observable on a thermal beam card. 

Images attached to this report
Comments related to this report
matthewrichard.todd@LIGO.ORG - 10:48, Tuesday 27 January 2026 (88914)

This morning we continued profiling to characterize the true L2 focal length and install the modeled telescope and characterize it.

We replaced L1 with L2 in the telescope and made several measurements to fit for a q-parameter after L2, because we think we know the q going into it quite well. Then with the q parameters, you can estimate the focal length using ABCD matrix for a thin lens (our estimates yield relatively low complex angles, less than 1 deg, making confident estimates).

Parameter x [m] y [m]
Input q (coming from the laser) 0.411 + 0.067i 0.376 + 0.056i
Output q (fit from profiles) 1.496 + 1.289i 1.221 + 0.632j
Focal Length (-q1/(q1/q2 - 1) 0.503 0.511

Average focal length of L2 = 0.507 m. Which is around 1.5% different from the spec'd value. To reiterate Sophie's log above, the focal length of L1 is estimated to be 0.217 m. Which is almost 9% different than the spec'd value. With these values in hand (as well as the updated value for CaF2 refractive index at 4.6um), we can make a more accurate model and see if measurements of the outgoing q-parameter from the telescope match that model.

We installed a telescope as set up in a model and measured several proviles to fit for the q-parameter after L2. The modeled waist size in both the horizontal and vertical are within the fit uncertainty; however the waist position of the modeled beam is roughly 20cm off in both directions. I think this is because of the Gouy phase regime that we are sampling gives better estimates of the waist size and since we did not sample near the waist we do not have a good idea of where it is.

This afternoon we will try and re-build the telescope as optimized in our models with these measurements to see if we can get a q-parameter that will be 53mm at the "ITM" (propagated 35m from L2).

Images attached to this comment
H1 CDS
jonathan.hanks@LIGO.ORG - posted 17:27, Monday 26 January 2026 (88901)
Started work on WP 12998 (installing new VM hosts)

Jonathan, Dave, Erik,

We started on WP 12998.  After doing WP 12997 we had freed up the space we needed to install the new VM hosts.

What we have done so far is to move the computers and the associated switch from the test stand and rack mount them in rack 12 in the MSR.  Jonathan has started the reconfiguration of the switch.

Todo tomorrow:

The new computers will be pve-node[0,1,2] and the switch is sw-msr-pve0.

H1 SUS (CDS)
oli.patane@LIGO.ORG - posted 17:34, Thursday 22 January 2026 - last comment - 09:21, Tuesday 27 January 2026(88860)
Current Status of SUS-C1/C2 Racks vs Final O5 Build

J. Kissel, O. Patane, D. Barker, F. Clara, M. Pirello

Our big SUSB123 and SUSH34 to SUSB13 and SUSB2H34 upgrade last week wasn't the full upgrade for O5.
SUSB13 is fully upgraded to its O5 configuration, but for SUSB2H34, we can't fully upgrade to the final O5 build yet because we still need full control of the BSFM for the February commissioning period, whereas O5 will have the BSFM replaced with the BBSS (with QOSEMs instead of BOSEMs), requiring different electronics. The final O5 build will also include the electronics for the new suspensions LO1 and LO2. Going from the current configuration, which we call the "No QOSEMs/BBSS" configuration, to our final O5 build will require eight new chassis and two new ADC cards.

Since we will be needing to add/change things on the racks, that future upgrade will also come with user model additions/changes.

Table showing comparison diagrams

  Current “No QOSEMs/BBSS” Config Final O5 Config
Rack overviews slide31 slide33
DACs slide10 (excluding BS BOT/LO1/LO2 and AI in U13) slide10 (everything)
ADCs slide15 slide16
BIOs slide21 (excluding BS BOT chans) slide21 (everything)
AUX ADCs slide26 (excluding pink) slide26 (everything)

I've also attached the slides above in pdf form here. The full slides outlining all the changes O4 -> now -> O5 can be found here.

Changes needed to go from current configuration to final O5 configuration:
SUS-C1
    U33:: Remove cable inputs for (BSFM) BS M1 OSEM sensors, re-arrange cable inputs for BS M3 Oplev to make room for (BBSS) BS M3 OSEM sensors, and bring in PR3 M3 Oplev because we can
    U14:: Add (BBSS) BS M3 input for Binary Output
    U13:: Add (BBSS) BS M3 input for Binary Input
    U5 :: New D090006 TACQ Driver for (BBSS) BS M3

SUS-C2
    U22:: Add (BBSS) BS M3 Noisemon and (BBSS) BS M3 SFVmon inputs
    U20:: New D0902783 AA Chassis for LO1 M1 and LO2 M1 HAM-A Coil Driver Volt Monitors
    U16:: New D1300282 AA Chassis for (BBSS) BS M1 QOSEM sensors and LO1 M1 and LO2 M1 OSEM sensors
    U14:: Add (BBSS) BS M3 input to AI chassis
    U13:: New D2500353 AI Chassis for LO1 and LO2 Coil Actuation
    U9 :: New D1100687-v1 (100 Ohm Output Impedance) HAMA Coil Driver for LO1 M1 F1F2F3SD
    U8 :: New D1100687-v1 (100 Ohm Output Impedance) HAMA Coil Driver for LO1 M1 LFRTxxxx
    U6 :: New D1100687-v1 (100 Ohm Output Impedance) HAMA Coil Driver for LO2 M1 F1F2F3SD
    U5 :: New D1100687-v1 (100 Ohm Output Impedance) HAMA Coil Driver for LO1 M1 LFRTxxxx
    
susb2h34 IO Chassis
    Needs an additional ADC Card (and adapter card and internal SCSI cable)

susauxb2h34 IO Chassis
    Needs an additional ADC Card (and adapter card and internal SCSI Cable)

Images attached to this report
Non-image files attached to this report
Comments related to this report
oli.patane@LIGO.ORG - 09:21, Tuesday 27 January 2026 (88908)

To clarify a bit on the status of SUSB13 and SUSB2H34, "as of these Jan 2026 changes, the SUSB13 racks and IO chassis are 'fully upgraded,’ as only the ITM QUADs are left in this system and there are no changes to the QUAD control system electronics for O5, and we’ve now upgraded the whole chassis to use 28-bit 32CH LIGO DACs. For the SUSB2H34 racks and IO chassis, while we’ve imported the existing BSFM beam splitter control system electronics, that’s all we can do at this point and we need the BS under control as it was for the Feb 2026 commissioning period. After that’s done, and as the suspensions get installed, we’ll add electronics to upgrade the BSFM BS to become a BBSS BS (with M1 QOSEMs replacing the M1 BOSEMs, and new M3 OSEMs for sensing and control there), and we install the LO1 and LO2 HRTS electronics for BHD as needed. So, it may be a while before the wiring diagrams match reality again".

(Thanks to Jeff for the clearer wording!)

Displaying reports 2601-2620 of 88977.Go to page Start 127 128 129 130 131 132 133 134 135 End