karmeng.kwan@LIGO.ORG - posted 16:33, Monday 05 January 2026 (88686)
Changes to IR dither lock setting

[Sheila, Karmeng]

To align OPO IR beam, we try to lock the IR dither lock at fundamental, but we were unable to see the error signal and dither. CLK_gain were changed from 0.1 to 1000, and the demodulation phase from 245 to 225. The resulting error signal as attached. A 200Hz wide bandpass filter added to the PD input dither around 3kHz, LSC_servo_gain changed from -10 to -300 to lock the OPO.

We also adjusted the beamsplitter (position before the IR camera) to center the IR beam on SQZT7 IR camera.

Images attached to this report
H1 General
ryan.crouch@LIGO.ORG - posted 15:54, Monday 05 January 2026 (88685)
OPS Monday Day shift summary

TITLE: 01/05 Day Shift: 1530-0030 UTC (0730-1630 PST), all times posted in UTC
STATE of H1: Planned Engineering
INCOMING OPERATOR: None
SHIFT SUMMARY: HAM7 and JAC work continued today.                                    

Start Time System Name Location Lazer_Haz Task Time End
15:57 SAF LASER SAFE LVEA NO LVEA is Upgrade Phase Laser SAFE 17:16
16:46 FAC Nellie, Kim LVEA N -> Y Tech clean 17:29
17:00 OPS Oli LVEA N -> Y Transition to HAZARD 17:16
17:15 ISC Jennie Optics lab LOCAL Gather JAC parts 17:32
17:16 HAZ LASER HAZARD LVEA Y LVEA IS LASER HAZARD 01:35
17:26 SQZ Sheila LVEA Y Turn on SQZ laser, maybe take a look at the table 17:55
17:29 FAC Nellie MidY N Tech clean 18:26
17:32 FAC Kim EndX N Get garb 18:38
18:06 ISC Jennie, Rick PCAL lab LOCAL Get parts for JAC 18:20
19:01 ISC Betsy LVEA Y Check on headsets 19:14
19:20 EE Marc, Fil CER Y Investigate failing PS, HV HAM6 pzt 20:26
21:26 ISC Jason, Jennie, Masayuki PSL enc Y JAC work Ongoing

19:32 UTC HAM1 ISI WD tripped

21:32 UTC DAQ restart

H1 CDS
david.barker@LIGO.ORG - posted 15:18, Monday 05 January 2026 - last comment - 11:18, Tuesday 06 January 2026(88687)
h1ascimc model change and DAQ restart

Jennie, Erik, Dave:

Jennie's new h1ascimc model was installed at 13:30 Mon 05Jan2026. This required a DAQ restart to add 2 slow channels.

At 13:32 we restarted the 1-leg, followed by the 0-leg at 13:37. GDS1 did not need a restart.

Following this DAQ restart we had 3 sponaneous restarts of FW1 after it had ran for 27:48, 8:02 and 6:22 minutes respectively. At the time of writing it has been running with no further restarts for an hour.

 

 

Comments related to this report
david.barker@LIGO.ORG - 10:15, Tuesday 06 January 2026 (88695)

Good news: FW1 has now been running 20 hours. Its beginning to look like the usual frame-writer-restarts-soon-after-DAQ-restart but with 3 restarts this time. We are not sure if we had seen a triple before.

Bad news: later yesterday afternoon h1daqgds0 daqd restarted itself coincident with Erik logging off of this machine. We did two more login/logout tests, the first restarted daqd the second did not. At this time is appeared to be related to the method of logging out, CTRL-D crashing daqd and "exit" not. I did another "exit" test this morning and unfortunately this time it did crash GDS0 DAQD. I restarted the 0-leg soon after (at 08:54) to resync the uptimes. So it appears to be independent of the method of logging out and is intermittent.

FRS36466 opened for this issue.

david.barker@LIGO.ORG - 11:18, Tuesday 06 January 2026 (88696)

Restart/Reboot Log --------------------------------------------------------

Mon05Jan2026
LOC TIME HOSTNAME     MODEL/REBOOT
13:30:32 h1asc0       h1ascimc    <<< Install Jennie's new model


13:32:11 h1daqdc1     [DAQ] <<< DAQ 1-LEG restart
13:32:19 h1daqfw1     [DAQ]
13:32:20 h1daqtw1     [DAQ]
13:32:21 h1daqnds1    [DAQ]
13:32:30 h1daqgds1    [DAQ]


13:37:38 h1daqgds0    [DAQ] <<< DAQ 0-LEG restart
13:37:43 h1daqfw0     [DAQ]
13:37:43 h1daqnds0    [DAQ]
13:37:43 h1daqtw0     [DAQ]


14:00:44 h1daqfw1     [DAQ] <<< Triple sponaneous FW1 restarts
14:09:39 h1daqfw1     [DAQ]
14:16:36 h1daqfw1     [DAQ]


16:41:00 h1daqgds0    [DAQ] <<< GDS0 DAQD restart on logout
16:45:12 h1daqgds0    [DAQ] <<< Test GDS0 crash reproducible
16:53:04 h1daqgds0    [DAQ] <<< Clean start of 0-leg
16:53:09 h1daqfw0     [DAQ]
16:53:09 h1daqtw0     [DAQ]
16:53:10 h1daqnds0    [DAQ]
 

LHO VE
david.barker@LIGO.ORG - posted 11:00, Monday 05 January 2026 (88683)
Mon CP1 Fill

Mon Jan 05 10:04:11 2026 INFO: Fill completed in 4min 8secs

I increased the setting for thermocouple nominal max from 20C to 30C to match current values and remove a VAC-SDF diff.

Images attached to this report
H1 SEI
ryan.crouch@LIGO.ORG - posted 09:03, Monday 05 January 2026 (88682)
Ground Seismometer Mass Position Check - Monthly

Closes FAMIS38887 , last checked in alog88362

HAMs 1-4, 7 and BSC2 are in non nominal SEI states due to the vent work.


2026-01-05 08:58:15.266231
There are 14 T240 proof masses out of range ( > 0.3 [V] )!
ETMX T240 2 DOF X/U = -1.625 [V]
ETMX T240 2 DOF Y/V = -1.709 [V]
ETMX T240 2 DOF Z/W = -0.94 [V]
ITMX T240 1 DOF X/U = -2.28 [V]
ITMX T240 1 DOF Y/V = 0.313 [V]
ITMX T240 1 DOF Z/W = 0.485 [V]
ITMX T240 3 DOF X/U = -2.433 [V]
ITMY T240 3 DOF X/U = -1.065 [V]
ITMY T240 3 DOF Z/W = -2.971 [V]
BS T240 1 DOF Y/V = -0.372 [V]
BS T240 3 DOF Z/W = -0.449 [V]
HAM8 1 DOF X/U = -0.316 [V]
HAM8 1 DOF Y/V = -0.444 [V]
HAM8 1 DOF Z/W = -0.755 [V]


All other proof masses are within range ( < 0.3 [V] ):
ETMX T240 1 DOF X/U = -0.007 [V]
ETMX T240 1 DOF Y/V = -0.041 [V]
ETMX T240 1 DOF Z/W = -0.024 [V]
ETMX T240 3 DOF X/U = -0.016 [V]
ETMX T240 3 DOF Y/V = -0.069 [V]
ETMX T240 3 DOF Z/W = -0.045 [V]
ETMY T240 1 DOF X/U = 0.066 [V]
ETMY T240 1 DOF Y/V = 0.208 [V]
ETMY T240 1 DOF Z/W = 0.266 [V]
ETMY T240 2 DOF X/U = -0.075 [V]
ETMY T240 2 DOF Y/V = 0.226 [V]
ETMY T240 2 DOF Z/W = 0.049 [V]
ETMY T240 3 DOF X/U = 0.282 [V]
ETMY T240 3 DOF Y/V = 0.096 [V]
ETMY T240 3 DOF Z/W = 0.149 [V]
ITMX T240 2 DOF X/U = 0.158 [V]
ITMX T240 2 DOF Y/V = 0.283 [V]
ITMX T240 2 DOF Z/W = 0.263 [V]
ITMX T240 3 DOF Y/V = 0.139 [V]
ITMX T240 3 DOF Z/W = 0.086 [V]
ITMY T240 1 DOF X/U = 0.07 [V]
ITMY T240 1 DOF Y/V = 0.147 [V]
ITMY T240 1 DOF Z/W = 0.021 [V]
ITMY T240 2 DOF X/U = 0.021 [V]
ITMY T240 2 DOF Y/V = 0.239 [V]
ITMY T240 2 DOF Z/W = 0.152 [V]
ITMY T240 3 DOF Y/V = 0.085 [V]
BS T240 1 DOF X/U = -0.107 [V]
BS T240 1 DOF Z/W = 0.123 [V]
BS T240 2 DOF X/U = -0.031 [V]
BS T240 2 DOF Y/V = 0.038 [V]
BS T240 2 DOF Z/W = -0.052 [V]
BS T240 3 DOF X/U = -0.222 [V]
BS T240 3 DOF Y/V = -0.289 [V]


Assessment complete.
Averaging Mass Centering channels for 10 [sec] ...


2026-01-05 08:58:27.267417
There are 2 STS proof masses out of range ( > 2.0 [V] )!
STS EY DOF X/U = -4.63 [V]
STS EY DOF Z/W = 2.377 [V]


All other proof masses are within range ( < 2.0 [V] ):
STS A DOF X/U = -0.492 [V]
STS A DOF Y/V = -0.851 [V]
STS A DOF Z/W = -0.499 [V]
STS B DOF X/U = 0.153 [V]
STS B DOF Y/V = 0.944 [V]
STS B DOF Z/W = -0.303 [V]
STS C DOF X/U = -0.867 [V]
STS C DOF Y/V = 0.801 [V]
STS C DOF Z/W = 0.594 [V]
STS EX DOF X/U = -0.218 [V]
STS EX DOF Y/V = -0.16 [V]
STS EX DOF Z/W = 0.036 [V]
STS EY DOF Y/V = 1.254 [V]
STS FC DOF X/U = 0.161 [V]
STS FC DOF Y/V = -1.157 [V]
STS FC DOF Z/W = 0.625 [V]
 

H1 SEI
ryan.crouch@LIGO.ORG - posted 08:53, Monday 05 January 2026 (88680)
ISI CPS Noise Spectra Check - Weekly

FAMIS 27701, last checked in alog88650

The script reports high frequency noise is elevated for HAM1_V3, HAM7_V{1,2,3} which makes sense as they're vented.  ITMX_ST1_V1 also reports elevated noise, ETMX_ST1_{H1,V3} are slightly elevated at high frequency.

HAMs 1-4 are still locked and the SEI configuration for the BS is in ISOLATED_DAMPED.

Non-image files attached to this report
H1 General (CDS)
ryan.crouch@LIGO.ORG - posted 07:29, Monday 05 January 2026 - last comment - 08:39, Monday 05 January 2026(88679)
OPS Monday Day shift start

TITLE: 01/05 Day Shift: 1530-0030 UTC (0730-1630 PST), all times posted in UTC
STATE of H1: Planned Engineering
OUTGOING OPERATOR: None
CURRENT ENVIRONMENT:
    SEI_ENV state: MAINTENANCE
    Wind: 12mph Gusts, 6mph 3min avg
    Primary useism: 0.02 μm/s
    Secondary useism: 0.31 μm/s 
QUICK SUMMARY:

Comments related to this report
david.barker@LIGO.ORG - 08:39, Monday 05 January 2026 (88681)

Erik, Dave:

All workstations and NUCs which had been powered down during the break have been powered back up.

1. picket fence is working again.

2. I have stopped running nuc_dummy_ioc.py which was temporarily serving dummy NUC EPICS channels to the EDC

3. cds_report has been reverted to the pre-break version (it had been expecting WS to be down and NUC reported had been removed)

LHO VE
david.barker@LIGO.ORG - posted 10:21, Sunday 04 January 2026 (88678)
Sun CP1 Fill

Sun Jan 04 10:09:35 2026 INFO: Fill completed in 9min 31secs

 

Images attached to this report
LHO FMCS
tyler.guidry@LIGO.ORG - posted 21:57, Saturday 03 January 2026 (88677)
EX Chilled Water Supply
At 9:42p local I received a cell alert declaring a loss of chilled water supply at End X. After remotely logging into FMCS I observed that the lead chiller (1) was in alarm and the CH-1 supply temp was hovering around 54F. I've since toggled the lead lag, and manually forced chiller 2 and chilled water pump 2 on. Given the low outside air temps and the lack of temp demands that vent require, this should suffice until all return from the break where we can investigate further.

T. Guidry
LHO VE
david.barker@LIGO.ORG - posted 10:40, Saturday 03 January 2026 (88676)
Sat CP1 Fill

Sat Jan 03 10:09:51 2026 INFO: Fill completed in 9min 48secs

 

Images attached to this report
H1 SEI
oli.patane@LIGO.ORG - posted 17:09, Friday 02 January 2026 (88675)
Reset ISI and HPI WDs after EQ trips earlier today

There were some SEI trips earlier today due to an earthquake. Dave went in and reset the software WDs earlier (88671), so to get the system back up to where it was before the earthquake, I went through and reset ISI and HPI to nominal for the chambers that needed them reset (aka not resetting them for the systems where we already have them down due to venting). Tony's overview and WD screenshots from Wednesday are a good reference for what state everything was in before the earthquake. This is what the OPS Overview looked like before I started resetting everything. Everything now that needed to be reset is back how it was before the earthquake (overview now).

Images attached to this report
LHO General (VE)
tyler.guidry@LIGO.ORG - posted 13:51, Friday 02 January 2026 (88674)
After hours site work 1/2/26
Upcoming LN2 deliveries at x mid and x end required some tumbleweed attention this afternoon. X1 is still largely clear and x mid should be easily accessible. The earlier half of X2 is the worst area. I was able to cut a single lane to X2 before the harvester jammed up beyond what I could free by myself. What remains in the harvester chute needs a few days to dry out. As do I.

As a follow up to my previous log I checked the magmeter in the water room which meters domestic supply to the site and found a reading of 1011247.

T. Guidry
LHO General
richard.mccarthy@LIGO.ORG - posted 12:02, Friday 02 January 2026 (88673)
First site inspection of the new year.

Site Walk Through 2 Jan 2026

LExC is in great shape no indication of problems.

Staging building is in good shape.

VPW two ovens running and in the parameters that Chris told us.  Weld shop temperature was fine so no pipe issues.

LSB looks fine.  Tyler was in his office

OSB/LVEA everything was in order.  Kobelco running door covers billowing slightly.  No signs of problems.

Mid and Ends were fine.  

Carpenter shop/ water room fire pump room and electrical room were all fine.

FCES in great shape.  

I leave the site with, Tyler clearing a path to EX for LN2 delivery.  I am his phone buddy.

 

LHO VE
david.barker@LIGO.ORG - posted 10:40, Friday 02 January 2026 (88672)
Fri CP1 Fill

Fri Jan 02 10:03:34 2026 INFO: Fill completed in 3min 32secs

 

Images attached to this report
H1 CDS
david.barker@LIGO.ORG - posted 10:32, Friday 02 January 2026 (88671)
Earthquake tripped both end station SWWDs Fri 02Jan2026 06:22 PST

Both end station test mass Software Watchdogs tripped around 06:22 during an earthquake. The Seismic systems also tripped for ETMX and ETMY. The TMS suspensions did not trip.

At 10:30 I reset these SWWDs, end station SUS and SEI are driving again.

LHO VE
david.barker@LIGO.ORG - posted 10:21, Thursday 01 January 2026 (88670)
Thu CP1 Fill

Thu Jan 01 10:04:27 2026 INFO: Fill completed in 4min 24secs

 

Images attached to this report
H1 CDS
david.barker@LIGO.ORG - posted 08:53, Thursday 01 January 2026 (88669)
VACSTAT detected EX vacuum glitch 03:39:34 Thu 01Jan2026 PST

VACSTAT detected a small beamtube vacuum gas release originating at the EX BT-IonPump which is located at approx -300m from EX.

Pressure trend shows the pressure at PT527 increased from its baseline of 1.9e-09 to a max of 1.4e-08 Torr. Several seconds later the EX gauges showed a minimal increase when the dispersed molecules reached them.

PT527 had pumped back down to its baseline by 04:30, +50 minutes after the glitch.

VACSTAT raised a single-gauge alarm for PT527, its rate-of-rise did not trip (reached 40% of trip level) but its Delta-P did trip (reached130% of trip level).

At 08:39 I restarted the vacstat_ioc.service on cdsioc0 to clear this alarm. As before, HAM1's gauge is currently set to disabled.

Images attached to this report
H1 General
anthony.sanchez@LIGO.ORG - posted 14:44, Wednesday 31 December 2025 (88668)
Wednesday Ops update.

TITLE: 12/31 Day Shift: 1530-0030 UTC (0730-1630 PST), all times posted in UTC
STATE of H1: Planned Engineering
OUTGOING OPERATOR: None
CURRENT ENVIRONMENT:
    SEI_ENV state: MAINTENANCE
    Wind: 4mph Gusts, 1mph 3min avg
    Primary useism: 0.04 μm/s
    Secondary useism: 0.68 μm/s 
QUICK SUMMARY:

Cameras:
Everything looks fine currently.  
No thing looksout of place. 

PSL status: 
Laser Status:
    NPRO output power is 1.824W
    AMP1 output power is 70.67W
    AMP2 output power is 139.6W
    NPRO watchdog is GREEN
    AMP1 watchdog is GREEN
    AMP2 watchdog is GREEN
    PDWD watchdog is GREEN

PMC:
    It has been locked 21 days, 20 hr 49 minutes
    Reflected power = 26.19W
    Transmitted power = 106.1W
    PowerSum = 132.3W

FSS:
    It has been locked for 8 days 2 hr and 17 min
    TPD[V] = 0.4524V

ISS:
    The diffracted power is around 3.1%
    Last saturation event was 8 days 1 hours and 27 minutes ago


Possible Issues:
    PMC reflected power is high

Images attached to this report
H1 AOS
jennifer.wright@LIGO.ORG - posted 17:32, Monday 22 December 2025 - last comment - 11:34, Monday 05 January 2026(88645)
Need model restart in week of Jan 5th to correct JAC/IMC models

Jennie W, Dave B,

 

Jeff and I put in a bypass in the h1ascimc model (see alog #88465) so we could put in the simulink infrastructure to switch between using the PSL periscope PZT as part of the IMC control or as part of the JAC control.

At the moment the switch 'H1:ASC-IMCJAC_PZTOUTSW' is set to ON which should let the IMC servo use the PZT.

However the logic I put in will not switch the feedback to take inputs from the JAC servo if I turn the switch off.

This is because Choice 2 and 3 in the picture are set to pass their first input if the switch output is '>= 0', so whichever state it is in the IMC PZT output will be sent to the DAC.

I have changed these choices to >0 so that the top input (IMC PZT output signal) will be sent to the DAC if the switch is 1 and the bottom input (JAC PZT output signal) will be sent to the periscope otherwise.

I committed the changed /opt/rtcds/userapps/release/asc/h1/models/h1ascimc.mdl to the svn.

Images attached to this report
Comments related to this report
jennifer.wright@LIGO.ORG - 11:34, Monday 05 January 2026 (88684)IOO

I also added two cdsepicsOutput blocks (ASC-PSL_PZT_P and ASC-PSL_PZT_Y) before the DAC outputs going to the PZT to check what the model is sending to the PZT which will help us double check the switch between IMC and JAC signals works correctly.
See screenshot attached. I rebuilt h1ascimc.mdl and committed it to the svn at userapps/asc/h1/models.