Displaying reports 3401-3420 of 89008.Go to page Start 167 168 169 170 171 172 173 174 175 End
Reports until 10:31, Sunday 16 November 2025
LHO VE
david.barker@LIGO.ORG - posted 10:31, Sunday 16 November 2025 (88129)
Sun CP1 Fill

Sun Nov 16 10:14:59 2025 INFO: Fill completed in 14min 56secs

 

Images attached to this report
H1 PSL
ryan.crouch@LIGO.ORG - posted 07:33, Sunday 16 November 2025 (88125)
PSL Status Report - Weekly

Closes FAMIS27539, last checked in alog88024.
Laser Status:
    NPRO output power is 1.871W
    AMP1 output power is 70.67W
    AMP2 output power is 139.0W
    NPRO watchdog is GREEN
    AMP1 watchdog is GREEN
    AMP2 watchdog is GREEN
    PDWD watchdog is GREEN

PMC:
    It has been locked 16 days, 17 hr 50 minutes
    Reflected power = 24.6W
    Transmitted power = 106.3W
    PowerSum = 130.9W

FSS:
    It has been locked for 0 days 0 hr and 11 min
    TPD[V] = 0.5264V

ISS:
    The diffracted power is around 4.1%
    Last saturation event was 0 days 0 hours and 51 minutes ago


Possible Issues:
    PMC reflected power is high

H1 General
ryan.crouch@LIGO.ORG - posted 07:30, Sunday 16 November 2025 - last comment - 09:52, Sunday 16 November 2025(88124)
OPS Sunday day shift start

TITLE: 11/16 Day Shift: 1530-0030 UTC (0730-1630 PST), all times posted in UTC
STATE of H1: Aligning
OUTGOING OPERATOR: Tony
CURRENT ENVIRONMENT:
    SEI_ENV state: CALM
    Wind: 4mph Gusts, 2mph 3min avg
    Primary useism: 0.02 μm/s
    Secondary useism: 0.26 μm/s 
QUICK SUMMARY:

Comments related to this report
ryan.crouch@LIGO.ORG - 08:18, Sunday 16 November 2025 (88126)Lockloss

16:14 UTC Lockloss at LOWNOISE_ESD_ETMX again... same spot as yesterday.

ryan.crouch@LIGO.ORG - 09:52, Sunday 16 November 2025 (88127)

17:51 UTC Observing

LHO General
ibrahim.abouelfettouh@LIGO.ORG - posted 22:01, Saturday 15 November 2025 (88123)
OPS Eve Shift Summary

TITLE: 11/16 Eve Shift: 0030-0600 UTC (1630-2200 PST), all times posted in UTC
STATE of H1: Observing at 142Mpc
INCOMING OPERATOR: Tony
SHIFT SUMMARY:

IFO is in NLN and OBSERVING as of 22:09 UTC (12 hr 40 min Lock)

Microseism has leveled out ad wind is low. Calm shift - locked and observing the whole time.

Throughout the whole lock, the range seems to be trending down very slowly and it seems to be in the low-mid frequency range (DARM looks noise from 40-300Hz) - can't pinpoint a cause.

LOG:

None

H1 General (SQZ)
ryan.crouch@LIGO.ORG - posted 16:31, Saturday 15 November 2025 (88119)
OPS Saturday Day shift summary

TITLE: 11/15 Day Shift: 1530-0030 UTC (0730-1630 PST), all times posted in UTC
STATE of H1: Observing at 146Mpc
INCOMING OPERATOR: Ibrahim
SHIFT SUMMARY: We recovered Observing once the microseism decreased and after fixing an ISC_LOCK typo. We've been locked for almost 7 hours.
LOG: No log.

LHO General
ibrahim.abouelfettouh@LIGO.ORG - posted 16:02, Saturday 15 November 2025 (88122)
OPS Eve Shift Start

TITLE: 11/15 Eve Shift: 0030-0600 UTC (1630-2200 PST), all times posted in UTC
STATE of H1: Observing at 146Mpc
OUTGOING OPERATOR: Ryan C
CURRENT ENVIRONMENT:
    SEI_ENV state: CALM
    Wind: 6mph Gusts, 5mph 3min avg
    Primary useism: 0.02 μm/s
    Secondary useism: 0.30 μm/s 
QUICK SUMMARY:

IFO is in NLN and OBSERVING as of 22:09 (6 hrs 45 mins) with a 30 min gap for planned calibration)

Microseism is down. Wind is down. Hoping for a quiet shift in OBSERVING.

H1 CAL
ryan.crouch@LIGO.ORG - posted 14:05, Saturday 15 November 2025 (88121)
Saturday calibration measurement

Broadband:
Start: 2025-11-15 21:31:45 UTC

Stop: 2025-11-15 21:36:56 UTC

File: /ligo/groups/cal/H1/measurements/PCALY2DARM_BB/PCALY2DARM_BB_20251115T213145Z.xml

Simulines:

Start: 2025-11-15 21:37:23.97 UTC // 1447277861.97 GPS

Stop: 2025-11-15 22:00:39.86 UTC // 1447279257.86 GPS

Files:

2025-11-15 22:00:39,689 | INFO | File written out to: /ligo/groups/cal/H1/measurements/DARMOLG_SS/DARMOLG_SS_20251115T213724Z.hdf5
2025-11-15 22:00:39,697 | INFO | File written out to: /ligo/groups/cal/H1/measurements/PCALY2DARM_SS/PCALY2DARM_SS_20251115T213724Z.hdf5
2025-11-15 22:00:39,701 | INFO | File written out to: /ligo/groups/cal/H1/measurements/SUSETMX_L1_SS/SUSETMX_L1_SS_20251115T213724Z.hdf5
2025-11-15 22:00:39,706 | INFO | File written out to: /ligo/groups/cal/H1/measurements/SUSETMX_L2_SS/SUSETMX_L2_SS_20251115T213724Z.hdf5
2025-11-15 22:00:39,711 | INFO | File written out to: /ligo/groups/cal/H1/measurements/SUSETMX_L3_SS/SUSETMX_L3_SS_20251115T213724Z.hdf5
 

 

Images attached to this report
Non-image files attached to this report
LHO VE
david.barker@LIGO.ORG - posted 10:17, Saturday 15 November 2025 (88120)
Sat CP1 Fill

Sat Nov 15 10:14:01 2025 INFO: Fill completed in 13min 57secs

 

Images attached to this report
H1 General
ryan.crouch@LIGO.ORG - posted 09:43, Saturday 15 November 2025 (88116)
OPS Saturday DAY shift update, Observing recovered

RyanC, Jenne, RyanS

The ground and wind finally let us lock which let me get to and fix the following small software issue to recover Observing.

16:26 UTC I removed an errant 'H1:' (good eye RyanS) in a ezca call in LOWNOISE_ESD_ETMX, and commented out the newest lines Jenne added at her suggestion and reloaded ISC_LOCK. Here are some the quads L3 lock filters right after LOWNOISE_ESD_ETMY finishes. I was then able to get back up to NLN after spending ~10 minutes in OMC_WHITENING 

From LOWNOISE_ESD_ETMX's main method I commented out:

# if ezca['SUS-ETMY_L3_DRIVEALIGN_L2L_GAIN'] != 1:
# ezca.get_LIGOFilter('SUS-ETMY_L3_DRIVEALIGN_L2L').only_on('INPUT','OUTPUT','DECIMATION')
# ezca['SUS-ETMY_L3_DRIVEALIGN_L2L_GAIN'] = 1
# ezca['H1:SUS-ETMY_L3_LOCK_OUTSW_L'] = 0  (Deleted H1:, the real issue here)
 
I then ran through ESD_ETMX and up to NLN without any issues. To get into Observing I started ISC_LOCK in a interactive env using "guardian -i ISC_LOCK" and I first zeroed the gains on the FFs filters that had gain.
In [1]: ezca.get_LIGOFilter('LSC-MICHFF').ramp_gain(0,  ramp_time=3, wait=False)
H1:LSC-MICHFF_GAIN => 0
In [2]: ezca.get_LIGOFilter('LSC-SRCLFF1').ramp_gain(0, ramp_time=3, wait=False)
H1:LSC-SRCLFF1_GAIN => 0
In [4]: ezca.get_LIGOFilter('LSC-PRCLFF').ramp_gain(0,  ramp_time=3, wait=False)
H1:LSC-PRCLFF_GAIN => 0

I then ran the commented out lines, excluding the if line waited a little bit then returned the FF gains to 1. There was a SQZ SDF diff I accepted.

I've uncommented out this block with the fixed typo but I forgot to reload ISC_LOCK, the typo fix has been svned.

17:24 UTC Observing

Images attached to this report
H1 General
ryan.crouch@LIGO.ORG - posted 07:28, Saturday 15 November 2025 - last comment - 09:25, Saturday 15 November 2025(88114)
OPS Saturday day shift start

TITLE: 11/15 Day Shift: 1530-0030 UTC (0730-1630 PST), all times posted in UTC
STATE of H1: Lock Acquisition
OUTGOING OPERATOR: Tony
CURRENT ENVIRONMENT:
    SEI_ENV state: CALM
    Wind: 19mph Gusts, 14mph 3min avg
    Primary useism: 0.02 μm/s
    Secondary useism: 0.28 μm/s 
QUICK SUMMARY:

Comments related to this report
ryan.crouch@LIGO.ORG - 09:25, Saturday 15 November 2025 (88117)

17:24 UTC Recovered Observing

H1 General
anthony.sanchez@LIGO.ORG - posted 07:00, Saturday 15 November 2025 - last comment - 09:26, Saturday 15 November 2025(88113)
LOWNOISE_ESD_ETMX Locking issue.

Called for the thrid time tonight:
First 2 times I just thought it was the wind kinda gusting too hard during LOWNOISE_ESD_ETMX as it was faily gusty between Costco & target here.
But.... this time the wind had calmed down significantly.

In the Last 4 Hours We have lost lock in the exact same spot 5 times.  Each time there is a Lownoise_ESD_ETMY state, then 4 seconds of Lownoise ETMX state then lockloss.

Troubleshooting: 
Maybe the issue is here: alog 88089. So I quickly reverted the changes in the code here right after power up, but I guess the power to the ITM ESD was tunt off as stated in that alog. So now I'm stuck at Transistion_From_ETMX with no way out except for manualing back to Lownoise_Coil_driver. Reverting my changes then Loading the guardian again and pushing forward to Lownoise_ESD_ETMY. 

Now  I'm hanging out at Low noise ESD ETMY for greater than 4 seconds, So we can rightfully say that the issue is in Lownoise_ESD_ETMX.
When I clicked into Lownoise_ESD_ETMX my Guardian back ground flashed red... indicating guardian issues , then:
E_X   (Nov 15 14:54:58 UTC)
E_Y   (Nov 15 14:54:58 UTC)
I_X   (Nov 15 14:54:58 UTC)
DRMI Unlocked   (Nov 15 14:54:58 UTC)
HAM6   (Nov 15 14:55:03 UTC)
ISC_LOCK state: DOWN   (Nov 15 14:55:04 UTC)
So the issue is certainly in LOWNOISE_ESD_ETMX. 

Comments related to this report
ryan.crouch@LIGO.ORG - 09:26, Saturday 15 November 2025 (88118)

This ended up being from a channel typo in a ezca call in LOWNOISE_ESD_ETMX.

H1 General
anthony.sanchez@LIGO.ORG - posted 02:02, Saturday 15 November 2025 (88112)
another Lockloss from Lownoise_ESD_ETMY [559]

TITLE: 11/15 Owl Shift: 0600-1530 UTC (2200-0730 PST), all times posted in UTC
STATE of H1: Wind
OUTGOING OPERATOR: Ibrahim
CURRENT ENVIRONMENT:
    SEI_ENV state: CALM
    Wind: 22mph Gusts, 18mph 3min avg
    Primary useism: 0.04 μm/s
    Secondary useism: 0.34 μm/s 
QUICK SUMMARY:

H1 called me, to watch it get locked again. 
Another lockloss at Lownoise_ESD_ETMY... 
I did another Initial_Alignment after that lockloss. we are currently just past DRMI again.
I will let it try again. The wind forecast looks like it will stay gusting in the 20's for a few hours but may start slowing around 11UTC. 

LHO General
ibrahim.abouelfettouh@LIGO.ORG - posted 21:59, Friday 14 November 2025 (88111)
OPS Eve Shift Summary

TITLE: 11/15 Eve Shift: 0030-0600 UTC (1630-2200 PST), all times posted in UTC
STATE of H1: Wind
INCOMING OPERATOR: Tony
SHIFT SUMMARY:

IFO is in ENGAGE_ASC_FOR_FULL_IFO and ENVIRONMENT

Still not locked due to wind and microseism.

Microseism just went below the 90% line where it's now lockable. As that happened we got gusts of wind from 35 to 45mph. The wind just went below 30mph so I think this lock acquisition might just work!

We lost lock over 30 times in this acquisition, making it to TRANSITION_FROM_ETMX twice before losing lock seemingly due to instability.

LOG:

None

H1 SQZ (SQZ)
karmeng.kwan@LIGO.ORG - posted 21:27, Friday 14 November 2025 - last comment - 15:19, Tuesday 20 January 2026(88110)
VOPO measurement setup

Attached is the mode-matching layout for the VOPO. The target primary waist of the VOPO (from TT1700104) is 221.2um(s), 206um(t) for 1064nm and 159.2um(s), 148.8um(t) for 532nm.

The mode matched minor and major beam waist is 198.6um, 204.2um for 1064nm and 152.6um, 185um for 532nm. For the fundamental injection via the rear mirror, the measured waist is 197.25um, 231.85um. These waist is measured at the position marked with a "star". The mode-matching calculation has been reviewed by a fur-low scientist.

Images attached to this report
Non-image files attached to this report
Comments related to this report
karmeng.kwan@LIGO.ORG - 10:47, Wednesday 14 January 2026 (88763)

I have included a diagram showing the components remaining on the optical table, which can be used for testing the homodyne detector.

The attached file also includes the corresponding mode-matching calculation, indicating the resulting beam waist location along the remaining optical path, for future reference.

Non-image files attached to this comment
corey.gray@LIGO.ORG - 15:19, Tuesday 20 January 2026 (88811)

Tagging EPO for photo of fur-low scientist.

H1 General
ryan.crouch@LIGO.ORG - posted 16:31, Friday 14 November 2025 (88108)
OPS Friday day shift summary

TITLE: 11/15 Day Shift: 1530-0030 UTC (0730-1630 PST), all times posted in UTC
STATE of H1: Microseism
INCOMING OPERATOR: Ibrahim
SHIFT SUMMARY: Unsuccessful day of locking, microseism continues to decrease, its starting to get below the 90th percentile, the wind has also calmed down over the past hour. We have been able to lock DRMI a few times, the highest we've made it has been MAX_POWER.
LOG:                                                                                 

Start Time System Name Location Lazer_Haz Task Time End
15:28 FAC Randy MidY to CS N Caulking BeamTube joints 22:51
15:30 FAC Nellie OSB N Open receiving doors 16:30
16:45 FAC Mitch Site N Dust monitor vaccum pump checks 17:49
18:33 PSL Kar Meng Optics lab Y ISS array 20:09
21:06 PSL Kar Meng Optics lab Y ISS array 23:40
21:59 ISC RyanS OPtics lab N CLeaning optics 23:38
23:04 CAL Tony PCAL lab LOCAL Start measurement 23:20

16:11 UTC IA

LHO General
ibrahim.abouelfettouh@LIGO.ORG - posted 16:03, Friday 14 November 2025 (88109)
OPS Eve Shift Start

TITLE: 11/15 Eve Shift: 0030-0600 UTC (1630-2200 PST), all times posted in UTC
STATE of H1: Microseism
OUTGOING OPERATOR: Ryan C
CURRENT ENVIRONMENT:
    SEI_ENV state: USEISM
    Wind: 13mph Gusts, 6mph 3min avg
    Primary useism: 0.05 μm/s
    Secondary useism: 0.55 μm/s 
QUICK SUMMARY:

IFO is LOCKING in ENVIRONMENT

Microseism is terrible but trending down. Wind has also been terrible but seems to be getting ok. Hoping to get locked during this shift as the microseism continues to trend down/

Displaying reports 3401-3420 of 89008.Go to page Start 167 168 169 170 171 172 173 174 175 End