ryan.short@LIGO.ORG - posted 07:41, Friday 24 January 2025 - last comment - 08:49, Friday 24 January 2025(82438)
Ops Day Shift Start

TITLE: 01/24 Day Shift: 1530-0030 UTC (0730-1630 PST), all times posted in UTC
STATE of H1: Lock Acquisition
OUTGOING OPERATOR: TJ
CURRENT ENVIRONMENT:
    SEI_ENV state: CALM
    Wind: 3mph Gusts, 1mph 3min avg
    Primary useism: 0.02 μm/s
    Secondary useism: 0.18 μm/s
QUICK SUMMARY: H1 lost lock just a half hour ago at 15:09 from a not obvious cause (link to lockloss tool) and is relocking; just reached DRMI.

Comments related to this report
ryan.short@LIGO.ORG - 08:49, Friday 24 January 2025 (82439)ISC

H1 back to observing at 16:45 UTC. Had to help PRM during DRMI locking, but otherwise this was an automatic relock.

I updated OMC-LSC_PHASEROT from -21 to 56 since TJ pointed out in his alog from last night and accepted it in both SAFE and OBSERVE SDF tables (screenshots attached). Since the OMC was already locked by the time I did this, I just used the command from alog82430, which worked and did not cause a lockloss. This is possibly why the calibration overnight looked strange.

Images attached to this comment
H1 General
thomas.shaffer@LIGO.ORG - posted 03:17, Friday 24 January 2025 - last comment - 04:06, Friday 24 January 2025(82436)
Ops Owl Update

During relocking, H1 couldn't get a DRMI or PRMI so it went to go to the Check_Mich_Fringes state but we lost lock a few seconds into it. The LASER_PWR node was still moving up to 10W that we use for Check_Mich at the time that the 2W request came in, but this was ignored while it was moving. I'm not entirely sure why. So as with many lock losses, our IMC lost lock and since we were at 10W, it couldn't relock. The IMC eventually relocked 2.5 hours later, long enough to give me a call. By the time I logged in, it was already started an initial alignment at 10W. I requested 2W for the PRC alignment step and then it finished off initial alignment on its own.

All of the states in LASER_PWR that do the adjusting are "protected" guardian states, meaning that they have to return true before it's allow to move on. I can't remember why exaclty, but I think this was because it would confuse the rotation stage if you made a power request while there's another one going on. I would expect that once this state was done though, that it would have then moved to the 2W adjusting state, but it looks like it ignored that request entirely. I'll add this to my todo list to fix.

Comments related to this report
thomas.shaffer@LIGO.ORG - 04:06, Friday 24 January 2025 (82437)CAL

I had to accept an SDF diff for the OMC-LSC_PHASEROT of -21. I'm actually thinking that this is the incorrect value and it should be the previous 56 value, but I don't want to risk losing lock.

Images attached to this comment
H1 General
anthony.sanchez@LIGO.ORG - posted 22:08, Thursday 23 January 2025 (82435)
Thursday Eve shift End

TITLE: 01/24 Eve Shift: 21:00-0600 UTC (1300-2200 PST), all times posted in UTC
STATE of H1: Observing at 149Mpc
INCOMING OPERATOR: TJ
SHIFT SUMMARY:
After we got to Observing  and everyone went home, nothing really happened after my last alog . Its been quiet ever since everyone left.

Since the Lockclock was interupted which was mentioned in my last alog, I should remind everyone:
This lock started at 19:41:24 UTC
Thus H1 has been locked for 10+ Hours.

oh also:
CALCS has some pending configuration changes according to the CDS Overview screen.

Images attached to this report
H1 General
anthony.sanchez@LIGO.ORG - posted 18:41, Thursday 23 January 2025 (82434)
Thursday mid shift report

TITLE: 01/24 Eve Shift: 21:00-0600 UTC (1300-2200 PST), all times posted in UTC
STATE of H1: Observing at 150Mpc
CURRENT ENVIRONMENT:
    SEI_ENV state: CALM
    Wind: 9mph Gusts, 6mph 3min avg
    Primary useism: 0.02 μm/s
    Secondary useism: 0.19 μm/s
QUICK SUMMARY:
H1 has been locked for 7 hours as of  02:41:24 UTC
H1 is currently Observing.
 

End of Comissioning and CtrlZ:
Calibration Team has been working all day on the OMC phase and gains.
Camilla touched up the SQZr settings and temp.
Robert covered the Viewports & we are almost ready to get back to Observing.

The calibration team now has to revert all of their changes.

GDS has been restarted a few times.

1:42 UTC DCPD AA filters turned off and phase changed. No lockloss!!! YAY!!
https://alog.ligo-wa.caltech.edu/aLOG/index.php?callRep=82433

After some final tweaks and some SDF accepts from Louis's changes, whe got back to OBSERVING without a Lockloss at 2:09 32 UTC!

 

This lock started at 19:41:24 UTC.
At 00:33 UTC I noticed that the Lock Clock FOM had crashed, and thus I relaunched the lockclock.
When it returned, it only had 30 minutes on it, even though we have not lost lock yet and had been locked for many hours.
All of the lock clocks all read the same 30 minutes.
On the Calibration_Monitor, CDS_OverView.
According to this FOM Screenshot of Nuc28 we had been locked for 4 hours and 19 minutes at 00:01 UTC:
https://lhocds.ligo-wa.caltech.edu/cr_screens/archive/png/2025/01/23/16/nuc28-1.png
The Lockclock crashed again, it may have coincided with a restart of GDS?  Sorry, Louis.  
After talking with Dave this turned out to be ; hand editing a puppet file issue.
When dave started working on this https://alog.ligo-wa.caltech.edu/aLOG/index.php?callRep=82429 puppet started to overwrite the file that he had changed.

H1 CAL
louis.dartez@LIGO.ORG - posted 18:09, Thursday 23 January 2025 (82433)
Calibration back to nominal - reverted everything to state before today's commissioning activities
J. Driggers, T. Sanchez, O. Patane, M. Todd, L. Dartez

This is a placeholder alog to state that the calibration and the ifo have been reverted to their nominal state from this morning. I'll follow up and edit this entry with additional details later tonight/ tomorrow morning.

In short:
- The OMC demod phase changes from LHO:82413 have been reverted using the steps in LHO:82430 successfully without breaking lock.
- The additional 16kHz AA filters in the DCPD A and B paths have been turned off.
- Camilla reverted her adjustments to the squeezer (LHO:82432)
- The calibration changes have been fully reverted.


There are many details to the several attempts we made to get things working in the calibration pipeline to keep the AA filtering in place. I'll share more with an update ASAP.
H1 CAL
matthewrichard.todd@LIGO.ORG - posted 16:45, Thursday 23 January 2025 - last comment - 13:05, Tuesday 10 June 2025(82430)
recipe for reverting new anti-aliasing filters w/o lockloss

[Jenne Louis Matt]

The change in the filters used by calibration created a 10% calibration error. Louis is trying to fix this but in an effort to have a way to revert to the previous filters without losing lock Jenne came up with a cdsutils way to revert back. Essentially it toggles off the new filters ('H1:OMC-DCPD_A0 FM10 H1:OMC-DCPD_B0') FM10 and steps the demod phase ('H1:OMC-LSC_PHASEROT') in steps of 1 degree, 77 times, with a 0.065 sec delay (77steps/5seconds) between each step. The filter toggles have a 5 second ramp time, which informs the step delay in the cdsutils step, and the 77 degrees is the difference from the old demod phase and the new. Hopefully this avoids a lockloss in the event we are to revert, but may not. *fingers crossed*

Here is the command:

cdsutils switch H1:OMC-DCPD_A0 FM10 OFF; cdsutils switch H1:OMC-DCPD_B0 FM10 OFF; cdsutils step H1:OMC-LSC_PHASEROT 1,77 -s 0.065

UPDATE:

It worked :) anti-alias filters off and OMC-LSC phaserot returned to nominal

Comments related to this report
anthony.sanchez@LIGO.ORG - 13:05, Tuesday 10 June 2025 (84933)

Joe, Fancisco and I got confused about the reverting and changing of the OMC Phase rot changes around this time.
I opened up an ndscope to see what happened.
 

Images attached to this comment
H1 CDS
david.barker@LIGO.ORG - posted 16:13, Thursday 23 January 2025 (82429)
Lock Loss Alert system bug fix

FRS33076 WP12300

Locklossalert had a bug whereby repeat GRD_NOTIFY cell phone calls/texts were not being sent if H1 remained in the same lock/unlocked state throughout. This was seen on at least two occasions, Monday 20th January at 4am and Sunday 12th January at 6am.

New code with the fix was restarted on cdslogin at 16:03 23jan2025. All LLA settings were restored, but the reset cleared the H1 lock-clock (from 4+ hrs).

H1 DetChar (DetChar)
ansel.neunzert@LIGO.ORG - posted 15:08, Thursday 23 January 2025 - last comment - 15:07, Wednesday 07 May 2025(82320)
Relationship between violin mode height and narrow spectral artifact contamination, revisited

Summary

Q: What is the relationship between the strength of violin mode ring-ups and the number of narrow spectral artifacts around the violin modes? Is there a clear cut-off at which the contamination begins?

A: The answer depends on the time period analyzed. There was an unusual time period spanning from mid-June 2023 through (very approximately) August 2023. During this time period, the number lines during ring-ups was much greater than in the rest of O4, and the appearance of the contamination may have begun at lower violin mode amplitudes.

What to keep in mind when looking at the plots.

1. These plots use the Fscan line count in a 200-Hz band around each violin mode region, which is a pretty rough metric, and not good for picking up small variations in the line count. It's the best we've got at the moment, and it can show big-picture changes. But on some days, contamination is present, but only in the form of ~10 narrow lines symmetrically arranged around a high violin mode peak. (Example in the last figure, fig 7) This small jump in the line count may not show up above the usual fluctuations. However, in aggregate (over all of O4) this phenomenon does become an issue for CW data quality. These "slight contamination" cases are also particularly important for answering the question "at what violin mode amplitude does the contamination just start to emerge?" In short, we shouldn't put too much faith in this method for locating a cut-off problematic violin mode height.

2. The violin modes may not be the only factor in play, so we shouldn't necessarily expect a very clear trend. For example, consider alog 79825 . This alog showed that at least some of the contamination lines are violin mode + calibration line intermodulations. Some of them (the weaker ones) disappeared below the rest of the noise when the violin mode amplitude decreased. Others (the stronger ones) remained visible at reduced amplitude. Both clusters vanished when the temporary calibration lines were off. If we asked the question "How high do the violin modes need to be...?" using just these two clusters, we'd get different apparent answers depending on (a) which cluster we chose to track (weak or strong), and (b) which time period we selected (calibration lines on or off). This is because at least some of the contamination is dependent on the presence & strength of a second line, not a violin mode.

Looking at the data

First, let's take a look at a simple scatter plot of the violin mode height vs the number of lines identified. This is figure 1. It's essentially an updated version of the scatter plots in alog 71501. It looks like there's a change around 1e-39 on the horizontal axis (which corresponds to peak violin mode height).

However, when we add color-coding by date (figure 2), new features can be seen. There's a shift at the left side of the plot, and an unusual group of high-line-count points in early O4.

The shift at the left side of the plot is likely due to an unrelated data quality issue: combs in the band of interest. In particular, the 9.5 Hz comb, which was identified and removed mid O4, contributes to the line count. Once we subtract out the number of lines which were identified as being part of a comb, this shift disappears (figure 3).

With the distracting factor of comb counts removed, we still need to understand the high-line-count time period. This is more interesting. I've broken the data down into three epochs: start of O4 - June 21, 2023 (figure 4); June 21, 2023 - Sept 1 2023 (figure 5); and Sept 1 2023 - present (figure 6). As shown in the plots, the middle epoch seems notably different from the others.

These dates are highly approximate. The violin mode ring-ups are intermittent, so it's not possible to pinpoint the changes sharply. The Sept 1 date is just the month boundary that seemed to best differentiate between the unusual time period and the rest of O4. The June 21 date is somewhat less arbitrary; it's the date on which the input power was brought back to 60W (alog 70648), which seems a bit suspicious. Note that, with this data set, I can't actually differentiate between a change on June 21 and a change (say) on June 15th, so please don't be misled by the specificity of the selected boundary.

Images attached to this report
Comments related to this report
kiet.pham@LIGO.ORG - 13:53, Friday 18 April 2025 (83997)DetChar

Kiet, Sheila

We recently started looking into the whether nonlinearity of the ADC can contribute to this by looking at the ADC range that we were using in O4a. 

They are showed in the H1:OMC-DCPD_A_WINDOW_{MAX,MIN} that sum the 4 DC photodiodes (DCPD). They are 18 bits DCPD, so that channel should saturate at 4* 2^17 ~520,000 counts. 

Now there are instances that agree with Ansel report when there are violin mode ring up that we can see a shift in the count baseline.

Jun 29 - Jun 30, 2023 when the baseline seems to shift up and stay there for >1 months, Detchar summary page show significant higher violin mode ring up in the usual 500-520Hz region as well as the nearby region (480-500 Hz) 

Oct 9, 2023 is when the temporary calibration lines are turned off 72096, the down shift happened right after the lines are off (after 16:40 UTC)

During this period, we were using a~5% of the ADC range (difference between max and min channel divided by the total range - 500,000 to 500,000 counts), and it went down to ~2.5 % once the shift happenned on Oct 9, 2023. We want to do something similar with Livingston, using the L1:IOP-LSC0_SAT_CHECK_DCPD_{A,B}_{MAX,MIN} channels to see the ADC range and the typical count values of those channels.

Another thing for us to maybe take a closer look is the baseline count value increase around May 03 2023. There was a change to the DCPC total photocurrent during that time (69358). Maybe worth checking if there is violin mode contaimination during the period before that. 


 

Images attached to this comment
kiet.pham@LIGO.ORG - 10:28, Tuesday 29 April 2025 (84136)DetChar

Kiet, Sheila

More updates related to the ADC range investigation: 

  • ADC ranges comparison between Hanford and Livingston: 
    • At Livingston we are using the L1:IOP-LSC0_SAT_CHECK_DCPD_{A,B}_{MAX,MIN} channels, which were not turned on until 1398035799; these channels saturate at 2^17 counts. 
    • At Hanford we are using the H1:OMC-DCPD_A_WINDOW_{MAX, MIN}, these channels saturate at 4 * 2^17 counts as they are sum over 4 DCPD
    • We looked through the data in Feb 2025 when the violin modes at Livingston were somewhat higher than usual. 
    • The range being used in compatible with Hanford (2-4%), and the count values are also similar as LHO counts/4 and LLO counts are in +- 5000 counts of each others.
  • Comparing the comtaimination before the DARM offset change in ER15:
    • We saw hint of contaimination even before the change (Using Fscan spectrum of May 2nd) 

Further points + investigations:

  • Ansel pointed out that it was odd to have a significant shift in the baseline count value + range when the temporary calibration lines turned off as these calibration lines were not that different in height than other calibration lines (see plot in the Alog 83997)
  • Joseph from LLO gave us a spectrum comparison between H1, L1 raw ADC count, there is a notable difference in the higher order violin modes
    • To do: looking to periods of when the both (1st and 2nd) violin modes ring up and periods of only the first violin mode ring up to see the contaimination caused by the 2nd mode or higher down mixing
  • Evan pointed out that during the period of high contaimination (June 30th - Aug 9th; 2023), the range stayed between 7 - 20%; and LHO in general seemed to have higher rate of saturation + intermitten increase of the ADC range than LLO. 
    • To do: Selecting the periods of stable ADC range in LHO data, and run the average spectrum over those periods to see the level of contaimination, assessing the contribution of the periods with increase ADC range. 

       
Images attached to this comment
kiet.pham@LIGO.ORG - 15:07, Wednesday 07 May 2025 (84305)DetChar

Kiet, Sheila

Following up on the investigation into potential intermixing between higher-order violin modes down to the ~500 Hz region:

The Fscan team compiled a detailed summary of the daily maximum peak height (log10 of peak height above noise in the first violin mode region) for the violin modes near 500 Hz (v1) and 1000 Hz (v2). They also tracked line counts in the corresponding frequency bands: 400–600 Hz for v1 and 900–1000 Hz for v2. This data is available in the Google spreadsheet (LIGO credentials required).

  • We identified dates when both violin modes were elevated (n1_height > 7; n2_height > 8) and when only the fundamental mode was elevated (n1_height > 7; n2_height < 8). For each case, we computed average PSDs using an FFT length of 1800 s. The study period spans from August 10, 2023, to January 14, 2025, starting when ADC counts stabilized after the temporary calibration lines at 24.4 and 24.5 Hz were turned off (see alog  72096)
    • The psds comparisons is shown in vmodes_psds_comparison.png.
      • Note that the number of averages differs between the cases; there are significantly fewer days with only v1 elevated, which explains why the [v1 high, v2 low] spectrum appears noisier in some regions. However, similar features are still present in the [v1 high, v2 high] case.
      • Notably, there appears to be more spectral content in the 450–550 Hz range when both modes are elevated, with certain lines showing significant power (highlighted in green).

 

  • Daily Fscan data around the violin modes is summarized in Pairwise_scatter_plots.png , where n1_height and n2_height are the max peak heights of v1 and v2, and n1_count and n2_count are the corresponding line counts. There appears to be a threshold in violin mode amplitude beyond which line counts increase (based on {n1_height, n2_height} vs. {n1_count, n2_count} trends).
  • We also ploted how n1_count varies with n2_height when n1_height is high in n1_count_vs_n2_height_when_v1_high.png

Next: We plan to further investigate the lines that appear when both modes are high, the goal is to identify possible intermodulation products using the recorded peak frequencies of the violin modes.

Images attached to this comment
H1 CAL
jeffrey.kissel@LIGO.ORG - posted 13:55, Thursday 23 January 2025 - last comment - 14:47, Thursday 23 January 2025(82417)
pydarm_H1.ini pyDARM DARM Loop Parameter File Updated to include Extra 65k to 16k Digital AA Filter, and IOPOMC0 Updated Filter File
J. Kissel, L. Dartez, E. Goetz

In process of updating the calibration after installing the extra AA 65k to 16k digital AA filter we turned on this morning (see 82404, 82412 and 82413), we've updated the "template" pyDARM DARM model parameter set that is the basis for all copies for every report against which the model is compared against measurement, and from which the calibration pipeline's model is derived.

The changes are relatively simple,
-omc_filter_noncompensating_modules = 9,10 : 9,10
+omc_filter_noncompensating_modules = 8,9,10 : 8,9,10

-omc_filter_file = Common/H1CalFilterArchive/h1iopomc0/H1IOPOMC0_1364929770.txt
+omc_filter_file = Common/H1CalFilterArchive/h1iopomc0/H1IOPOMC0_1421610658.txt
where the "-" lines are the "before" and the "+" lines are the "after."

Here's the location of the file, and the corresponding "before" vs. "after" git commit hash.

    /ligo/groups/cal/H1/ifo/pydarm_H1.ini
        Previous version f480b0a1
        Now new version 17649002
Comments related to this report
jeffrey.kissel@LIGO.ORG - 14:47, Thursday 23 January 2025 (82427)
Also (somehow) remembered that another minor problem with the TST stage actuation path was the current CALCS replica of the L2L_DRIVEALIGN_GAIN. 
     H1:CAL-CS_DARM_FE_ETMX_L3_DRIVEALIGN_L2L_GAIN
needs to be the same the pydarm_H1.ini vs. what's in the front-end.

Changed the value from 191.712 to 184.65,
    - tst_drive_align_gain = 191.712
    + tst_drive_align_gain = 184.65

This is all changing the same file in the same location, but here's the next iteration's change.
    /ligo/groups/cal/H1/ifo/pydarm_H1.ini ccc02365
jeffrey.kissel@LIGO.ORG - 14:24, Thursday 23 January 2025 (82426)
In addition to changing the parameter file for the extra OMC DCPD digital AA filtering, we decided to *also* push a somewhat long-standing issue with apparent delays in actuation functions. 

We're applying 23.0e-6 [sec] worth of delay to the model of the UIM stage, and more consequentially, 20.2e-6 worth of delay to the TST stage. Both numbers are informed by the fit to the actuation measurements we just took, see 20250123T211118Z.

The updated parameter set has been push to git with the following local location and mothership git hash.  
     /ligo/groups/cal/H1/ifo/pydarm_H1.ini 4d9eb345

The calibration we installed / pushed / exported today will have all three of these changes in play.
H1 General
anthony.sanchez@LIGO.ORG - posted 13:10, Thursday 23 January 2025 (82423)
Thursday Eve shift start

TITLE: 01/23 Eve Shift: 21:00-0600 UTC (1300-2200 PST), all times posted in UTC
STATE of H1: Commissioning
OUTGOING OPERATOR: TJ
CURRENT ENVIRONMENT:
    SEI_ENV state: CALM
    Wind: 21mph Gusts, 14mph 3min avg
    Primary useism: 0.04 μm/s
    Secondary useism: 0.20 μm/s
QUICK SUMMARY:
Tj is out early & I'm starting Eve shift starting now.
H1 is currently in Nominal_Low_Noise and Comissioning.
The Calibration team is running some OMC tests  and we will return back to Observing around 22:00 UTC.

 

LHO General
thomas.shaffer@LIGO.ORG - posted 13:04, Thursday 23 January 2025 (82411)
Ops Day Shift End

TITLE: 01/23 Day Shift: 1530-0030 UTC (0730-1630 PST), all times posted in UTC
STATE of H1: Commissioning
INCOMING OPERATOR: Tony
SHIFT SUMMARY: We are currently finishing up few minor commissioning items and a calibration measurement and then we will be headed into observing. Two lock losses during my shift, one from the calibrators and one most likely from some view port work. Relocks were straight forward.
LOG:

Start Time System Name Location Lazer_Haz Task Time End
17:16 SAFETY LAZER HAZ  (\u2310\u25a0-\u25a0) LVEA !!!YES!!! LVEA = LASER HAZARD! 16:35
16:35 FAC Kim Opt Lab n Tech clean 16:57
17:55 FAC Kim MY n Tech clean 18:59
18:12 PEM Robert LVEA YES Setup viewport power metering 18:47
18:15 VAC Richard, Ken EX n Look at compressor electrical 18:47
18:49 ISS Keita, Rahul, Mayank, Sivananda, Jennie Opt Lab n ISS array prep 20:36
19:41 PEM Robert LVEA yes VP pictures near BSC3 20:31
H1 SQZ
camilla.compton@LIGO.ORG - posted 12:33, Thursday 23 January 2025 - last comment - 17:04, Thursday 23 January 2025(82421)
SQZ phase servo effected by OMC digital phase changes?

After the CAL team changed the OMC digital phase in 82413, the SQZ at the start of the lock went through an excursion much larger than usual, all the way to 5dB of ASQZ before settling around -3.5dB of SQZ, plot. We often have a SQZ excursion at the start of the lock but it rarely gets above 0dB. We are unsure if it makes sense that the OMC change would effect the SQZ like this or we were just unlucky.

I paused SQZ_MANGER and took SQZ_ANG_ADF to DOWN. I think tuned H1:SQZ-CLF_REFL_RF6_PHASE_PHASEDEG for the best SQZ and adjusted H1:SQZ-ADF_OMC_TRANS_PHASE to get H1:SQZ-ADF_OMC_TRANS_SQZ_ANG to zero, effectively setting the setpoint of the servo. Adjusted from -138 to -128 sdf. We may need to change this again or revert before going back to observing if the SQZ isn't good with a more thermalized IFO.

Also used this time to reduce the HAM7 rejected SHG power. Enabling (not moving) the picos unlocked SQZ which is surprising.

Images attached to this report
Comments related to this report
jeffrey.kissel@LIGO.ORG - 12:49, Thursday 23 January 2025 (82422)CAL, ISC, SQZ
The supposition of *how* the change in digital anti-aliasing might have impacted the ADF / SQZ loop is as follows:
- The actuation / excitation of the ADF / SQZ tuning system is a single line driven into the ADF's VCXO at 322.0 Hz.
- That ADF field beats against the IFO field, which is influenced by the DARM control loop.
- The new digital AA filter causes -4.5 deg phase loss (and an increase in amplitude of 0.1%) at 322.0 Hz, and changes the DARM open loop gain in that same way.
- Thus the 322 Hz DEMOD of the IFO vs. SQZ beatnote field that's picked off at 3.125 MHz needs a phase adjustment.

If that (I don't really know what I'm talking about) model of what's happening is happening, I would have expected the ADF SQZ DEMOD phase to need exactly 4.5 [deg] of phase change, much like the OMC LSC SERVO's DEMOD phase needed changing at it's modulation frequency (see LHO:82413).

Camilla's main log here suggests a (-138) - (-128) = 10 [deg] phase shift.

I very much welcome other mechanisms/models of what has happened if this change in SQZ behavior is a result of the OMC DCPD digital filter change.
Images attached to this comment
camilla.compton@LIGO.ORG - 15:25, Thursday 23 January 2025 (82428)

Once we'd been locked for 4 hours, I again tweaked the SQZ angle by finding the angle ether side of good SQZ and going to the middle the adjusting ADF phase, diff attached, so that the total phase change since the OMC changes is the 4deg that Jeff predicted.

SQZ at 1kHz+ still isn't as good as I remember so we touched the OPO temp while in observing as in 80461, no change needed.

Images attached to this comment
camilla.compton@LIGO.ORG - 17:04, Thursday 23 January 2025 (82432)

Reverted back to -128deg ready for reverting CAL team to revert thier changes.

H1 ISC (CAL, DetChar, ISC)
evan.goetz@LIGO.ORG - posted 12:27, Thursday 23 January 2025 - last comment - 16:59, Thursday 23 January 2025(82420)
Preliminary look at 524k and 16k DCPD data before and after additional anti-alias filtering
E. Goetz, J. Kissel, L. Dartez

In previous aLOGs (see, e.g., LHO aLOG 82405), we had to decimate the 524 kHz data offline in order to evaluate the improvement of TEST channels with changes to anti-alias filtering. We expected to see a reduction in artifacts with the addition of 1 extra 65-16k decimation filter. Attached is a figure showing before and after the ratio of ASDs calculated in DTT from the DCPD A0 channel (not the TEST A channels). This figure shows some improvements (though perhaps hard to see visually) and introduces more questions, especially comparing to a plot like in LHO aLOG 82405, attached here as well.

Statistics:
Bins above 1% before = 33416
Bins above 1% after = 30273
Bins above 1% before, f < 2000 Hz = 9011
Bins above 1% after, f < 2000 Hz = 8362
Mean before = 1.1087
Mean after = 1.0651
Mean before, f < 2000 Hz = 1.0756
Mean after, f < 2000 = 1.0495

So we do see that the number of bins above 1% has gone down as expected (good), but the raw number of bins above 1% is much different than our expectations. Figure 1 simply seems far noisier than Figure 2. What is the cause of this? It would seem to imply that the IOP downsampling is not simply grabbing 1 value for every 32 samples in a consistent manner, or perhaps the way DTT grabs and exports the PSD data? I'll have to keep digging, but this seems strange
Images attached to this report
Comments related to this report
erik.vonreis@LIGO.ORG - 14:06, Thursday 23 January 2025 (82425)

This may be improved by using a the double precision version of diaggui, 'diaggui_test', creates much less noisy ASDs, especially at higher frequencies.

 

In the attached image, single precision ASD is on the left and double precision is i on the right.

Images attached to this comment
evan.goetz@LIGO.ORG - 16:59, Thursday 23 January 2025 (82431)
There may be a DTT export precision issue at play here with the ASD as Erik suggests. I wanted to carry out a time series analysis offline, so I exported all of the data before and after for the 16k (H1:OMC-DCPD_A_OUT_DQ) and 524k (H1:OMC-DCPD_A0_OUT) channels. Then I computed the PSD of the 524k channel and 16k channel, plus downsampling the 524k channel and computing the PSD.

Then I plot the ratio of the 16k PSD over the 524k PSD (cut off to the 16k Nyquist) to inspect the data for excess noise before and after the addition of the extra 65-16k downsampling filter. I don't understand the red curve, but the blue curve seems reasonable, as well as the black and grey curves. The blue curve shows excess noise that is then suppressed by the additional filter seen in the absence of large ratio values in the black and gray curves.

This result shows that the extra filtering is helpful, but until we can push a new calibration, we'll have to hold off adding it in.
Images attached to this comment
H1 ISC (CAL, ISC)
jeffrey.kissel@LIGO.ORG - posted 12:09, Tuesday 21 January 2025 - last comment - 13:02, Friday 24 January 2025(82375)
Digital Anti-Aliasing Options for 524kHz OMC DCPD Path
J. Kissel, E. Goetz, L. Dartez

As mentioned briefly in LHO:82329 -- after discovering that there is a significant amount of aliasing from the 524 kHz version of the OMC DCPD signals when down-sampled to 16 kHz -- Louis and Evan tried a versions of the (test, pick-off, A1, A2, B1, and B2) DCPD signal path with two copies, each, of the existing 524 kHz to 65kHz and 65 kHz to 16 kHz AA filters as opposed to one. In this aLOG, I'll refer to these filters as "Dec65k" and "Dec16k," or for short in the plots attached "65k" and "16k."

Just restating the conclusion from LHO:82329 :: Having two copies of these filters -- and thus a factor of 10x more suppression in the 8 to 32kHz region and 100x more suppression in the 32 to 232 kHz region -- seems to dramatically improve the amount of aliasing.

Recall these filters were designed with lots of compromises in mind -- see all the details in G2202011.

Upon discussion of applying this "why don't we just add MOAR FIRE" option 2xDec65k and 2xDec16k option for the primary signal path, there was concerns about 
    - DARM open loop gain phase margin, and
    - Computational turn-around time for the h1iopomc0 front-end process.

I attach two plots to help facilitate that discussion,
    (1st attachment) Bode plot of various combinations of the Dec65k and Dec16k filters.
    (2nd attachment) Plot of the CPU timing meter over the weekend, the during in which these filters were installed and ON in the 4x test banks on the same computer.

For (1st) :: Here we show several of the high-frequency suppression above 1000 Hz, and phase loss around 100 Hz for a couple of simple combinations of filtering. The weekend configuration of two copies of the 65k and 16k filters is shown in BLACK, the nominal configuration of one copy is shown in RED. In short -- all these combinations incur less than 5 deg phase loss around the DARM UGF. Louis is going do some modeling to show the impact of these combinations on the DARM loop stability via plots of open loop gain and loop suppression. We anecdotally remember that the phase margin is "pretty tight," sub-30 [deg], but we'll wait for the plots.

For (2nd) :: With the weekend configuration of filters, with eight more filters (the copies of the 65k and 16k, copied 4 times in each of the A1, A2, B1, B2 banks) installed and running, the extremes of CPU clock cycle turnaround time did increase, from "never above 13 [usec]" to "occasionally hitting 14 [usec]" out of the ideal 1/2^16 = 15.26 [usec], which is rounded up on the GDSTP MEDM screen to be an even 16 [usec]. This is to say, that "we can probably run with 4 more filters in the A0 and B0 banks," though that may necessarily limit how much filtering can be in the A1, A2, B1, B2 banks for future testing. Also, no one has really looked at what happens to the gravitational wave channel when the timing of the CPU changes, or gets near the ideal clock-cycle time, namely the basic question "Are there glitches in the GW data when the CPU runs longer than normal?"
Images attached to this report
Comments related to this report
erik.vonreis@LIGO.ORG - 13:28, Thursday 23 January 2025 (82424)

Unless a DAC, ADC, or IPC timing error occurs, then a long IOP cycle time will not affect the data.  The models have some buffering, so can even suffer an occaisional long cycle time beyond the maximum without affecting data.

h1iopomc0 average cycle time is about 8 us (see the IO Info button on the GDS TP screen), so can probably run with a consistent max cycle time well beyond 15 us without affecting data.

jeffrey.kissel@LIGO.ORG - 13:02, Friday 24 January 2025 (82444)
Here, the 1st attachment, a two week trend of H1IOPOMC0 front-end (DCUID 179) CPU timing activity during this time periods flurry of activity in installing, turning on, and using lots of different combinations of (relatively low Q, low-order, low SOS number) filters. While the minute trend of the primary "CPU_METER" channel is creeping up, the "CPU_AVG" has only incremented up once to 8 [usec] that Erik quotes above. 

FYI these channels can be found displayed on MEDM in the IOP's GDS_TP screen, following the link to "IO Info" and looking at the "CPU PROCESSING TIMES" section at the top middle. See second attachment.
Images attached to this comment
Displaying reports 3421-3440 of 83479.Go to page Start 168 169 170 171 172 173 174 175 176 End