Displaying reports 3501-3520 of 89075.Go to page Start 172 173 174 175 176 177 178 179 180 End
Reports until 12:41, Thursday 13 November 2025
H1 General
matthewrichard.todd@LIGO.ORG - posted 12:41, Thursday 13 November 2025 (88093)
Updating TCS SIM values

M. Todd


From some of the modeling I've been doing, I've come up with a slew of estimates for coupling factors of TCS power settings to substrate and surface defocus. I've put them into TCS and SDF'd them, hoping that the next week or two we get some good confirmation of these numbers.

Images attached to this report
LHO VE
david.barker@LIGO.ORG - posted 10:58, Thursday 13 November 2025 (88091)
Thu CP1 Fill

Thu Nov 13 10:13:43 2025 INFO: Fill completed in 13min 39secs

Gerardo confirmed a good fill curbside.

Images attached to this report
H1 DetChar (DetChar)
joan-rene.merou@LIGO.ORG - posted 10:26, Thursday 13 November 2025 - last comment - 09:11, Friday 19 December 2025(88089)
With voltage set to 0, grounding of the ITMX ESD driver
[Joan-Rene Merou, Alicia Calafat, Sheila Dwyer, Jenne Driggers]

We have entered the LVEA and went to the Beer garden. There, we first turned off the Low Voltage ITM ESD Driver D1600092, first the 15V switch and then the medium voltage switch. In order to turn it on again, it should be reconnected in the opposite order. With the voltage request set to 0 and chassis powered off, we have unplugged the SHV cables going to the chamber and plugged into Robert's ground boxes, which we used to ground to the rack which is grounded to the chamber. This has been done at both drivers (See attached photos).

Afterwards, we have changed the code at /opt/rtcds/userapps/release/isc/h1/guardian/ISC_LOCK.py in order that the LOWNOISE_COIL_DRIVERS will go to LOWNOISE_ESD_ETMY instead of TRANSITION_FROM_ETMX. This has been done by changing lines 6670 and 6674, moving the ", 15" step from line 6670 to 6674. Finally, we communicated the change to the operator and loaded the guardian.
Images attached to this report
Comments related to this report
joan-rene.merou@LIGO.ORG - 13:28, Wednesday 26 November 2025 (88257)
It appears that the grounding did not decrease the amplitude of the combs. As seen in the attached figure, the relative amplitude of the first harmonics of the combs remains mostly the same before and after the change on November 13th.
Non-image files attached to this comment
corey.gray@LIGO.ORG - 09:11, Friday 19 December 2025 (88616)EPO

EPO-Tagging for photo of ESD work

H1 SQZ
matthewrichard.todd@LIGO.ORG - posted 09:34, Thursday 13 November 2025 (88088)
OMC scan with SQZ beam and cold OM2, changing ZM4/5 -- 20251113

M. Todd, S. Dwyer


We wanted to get a couple of measurements of the OMC mismatch with the SQZ beam when we changed from the nominal setting for only one of the ZMs at a time. OM2 was cold for all of these measurements.

Measurement Time OMC Mismatch [%]
ZM4 = 6.2, ZM5 = -0.4 (nominal) 1447088389  2.8 
ZM4 = 4, ZM5 = -0.4 1447088919  2.4 
ZM4 = 6.2, ZM5 = -4.5 1447089464  10.5

It seems the ZM4 is not a very strong actuator for changing the mode at the OMC.

Images attached to this report
H1 PSL
oli.patane@LIGO.ORG - posted 09:29, Thursday 13 November 2025 - last comment - 09:14, Wednesday 19 November 2025(88087)
IMC_LOCK stuck in FAULT due to FSS oscillation

During PRC Align, IMC unlocked and couldn't relock due to the FSS oscillating a lot - PZT MON was showing it moving all over the place, and I couldn't even take the IMC to OFFLILNE or DOWN due to the PSL ready check failing. To try and fix the oscillation issue, I turned off the autolock for the Loop Automation on the FSS screen, and after a few seconds re-enabled the autolocking, and then we were able to go to DOWN fine, and then I was able to relock the IMC.

TJ said this has happened to him and to a couple other operators recently.

 

Images attached to this report
Comments related to this report
jason.oberling@LIGO.ORG - 11:07, Thursday 13 November 2025 (88090)OpsInfo

Took a look at this, see attached trends.  What happened here is the FSS autolocker got stuck between states 2 and 3 due to the oscillation.  The autolocker is programmed to, if it detects an oscillation, jump immediately back to State 2 to lower the common gain and ramp it back up to hopefully clear the oscillation.  It does this via a scalar multiplier of the FSS common gain that ranges from 0 to 1, which ramps the gain from 0dB to its previous value (15dB in this case); it does not touch the gain slider, it does it all in block of C code called by the front end model.  The problem here is that 0dB is not generally low enough to clear the oscillation, so it gets stuck in this State 2/State 3 loop and has a very hard time getting out of it.  This is seen in the lower left plot, H1:PSL-FSS_AUTOLOCK_STATE, it never gets to State 4 but continuously bounces between States 2 and 3; the autolocker does not lower the common gain slider, as seen in the center-left plot.  If this happens, turning the autolocker off then on again is most definitely the correct course of action.

We have an FSS guardian node that also raises and lowers the gains via the sliders, and this guardian takes the gains to their slider minimum of -10dB which is low enough to clear the majority of oscillations.  So why not use this during lock acquisition?  When an oscillation is detected during the lock acquisition sequence, the guardian node and the autolocker will fight each other.  This conflict makes lock acquisition take much longer, several 10s of minutes, so the guardian node is not engaged during RefCav lock acquisition.

Talking with TJ this morning, he asked if the FSS guardian node could handle the autolocker off/on if/when it gets stuck in this State 2/State 3 loop.  On the surface I don't see a reason why this wouldn't work, so I'll start talking with Ryan S. about how we'd go about implementing and testing this.  For OPS: In the interim, if this happens again please do not wait for the oscillation to clear on its own.  If you notice the FSS is not relocking after an IMC lockloss, open the FSS MEDM screen (Sitemap -> PSL -> FSS) and look at the autolocker in the middle of the screen and the gain sliders at the bottom.  If the autolocker state is bouncing between 2 and 3 and the gain sliders are not changing, immediately turn the autolocker off, wait a little bit, and turn it on again.

Images attached to this comment
jason.oberling@LIGO.ORG - 09:14, Wednesday 19 November 2025 (88170)

Slight correction to the above.  The autolocker did not get stuck between states 2 and 3, as there is no path from state 3 to state 2 in the code.  What's happening is the autolocker goes into state 4, detects an oscillation, then immediately jumps back to state 2; so this is a loop from states 2 -> 3 -> 4 -> 2 due to the oscillation and the inability of the autolocker gain ramp to effectively clear it.  This happens at the clock speed of the FSS FE computer, while the channel that monitors the autolocker state is only a 16 Hz channel.  So the monitor channel is no where close to fast enough to see all of the state changes the code is going through during an oscillation.

H1 CDS
david.barker@LIGO.ORG - posted 08:10, Thursday 13 November 2025 (88085)
EY vacuum glitch at beam tube ion pump 03:00:16 Thu 13 Nov 2025 PST

VACSTAT detected a vacuum glitch at 03:00:24 this morning originating with PT427 (EY beam tube ion pump station, about 1000 feet from EY). The vacuum pressure rapidly increased from 1.4e-09 to 1.4e-07 Torr. It then rapidly pumped back down to nominal in 8 seconds. The glitch was detected soon afterwards by all of the gauges in EY. They only increased  from around 1.0e-09 to 2.0e-09 and they took around 25 minutes to pump down.

The glitch was seen at MY as a much reduced amplitude about 6 minutes after the event.

H1 was not locked at the time.

Images attached to this report
H1 General
oli.patane@LIGO.ORG - posted 07:37, Thursday 13 November 2025 - last comment - 08:22, Thursday 13 November 2025(88084)
Ops Day Shift Start

TITLE: 11/13 Day Shift: 1530-0030 UTC (0730-1630 PST), all times posted in UTC
STATE of H1: Microseism
OUTGOING OPERATOR: TJ
CURRENT ENVIRONMENT:
    SEI_ENV state: USEISM
    Wind: 3mph Gusts, 0mph 3min avg
    Primary useism: 0.05 μm/s
    Secondary useism: 1.22 μm/s 
QUICK SUMMARY:

Currently in DOWN due to excessively high secondary microseism. We're supposed to have calibration measurements and commissioning today. I'll try for a bit to get us back up, but I doubt we'll get past DRMI since it's worse now than it was last night for Ryan or TJ

Comments related to this report
david.barker@LIGO.ORG - 08:22, Thursday 13 November 2025 (88086)

I restarted VACSTAT at 08:18 to clear its alarm. Tyler resolved the RO alarm at 06:17 and now the CDS ALARM is GREEN again.

H1 General
thomas.shaffer@LIGO.ORG - posted 02:54, Thursday 13 November 2025 (88083)
Ops Owl Update

The useism continues to grow. I'll keep the IFO in down and see where things are at again in a few hours.

LHO General
ryan.short@LIGO.ORG - posted 22:01, Wednesday 12 November 2025 (88082)
Ops Eve Shift Summary

TITLE: 11/13 Eve Shift: 0030-0600 UTC (1630-2200 PST), all times posted in UTC
STATE of H1: Microseism
INCOMING OPERATOR: TJ
SHIFT SUMMARY: H1 was happily observing until mid-shift when the microseism just got too high and caused a lockloss. Haven't been able to make it past DRMI since then due to the ground motion. I'm leaving H1 in 'DOWN' since it's not having any success, but TJ says he'll check on things overnight.
LOG:

H1 General (Lockloss)
ryan.short@LIGO.ORG - posted 19:19, Wednesday 12 November 2025 (88081)
Lockloss @ 02:44 UTC

Lockloss @ 02:44 UTC - link to lockloss tool

Possibly caused by ground motion, as everything looked to be moving quite a lot at the time, and the secondary microseism band has been rising this evening. Environment plots on the lockloss tool show a quick increase in motion at the time of the lockloss also.

H1 General
oli.patane@LIGO.ORG - posted 16:36, Wednesday 12 November 2025 - last comment - 17:08, Wednesday 12 November 2025(88079)
Ops Day Shift End

TITLE: 11/13 Day Shift: 1530-0030 UTC (0730-1630 PST), all times posted in UTC
STATE of H1: Observing at 147Mpc
INCOMING OPERATOR: Ryan S
SHIFT SUMMARY: Observing at 140 Mpc and have been Locked for over 16.5 hours. One short drop out of Observing due to the squeezer dropping out, but that relocked automatically and we're been Observing ever since. GRB-Short E617667 came in today at 21:29 UTC
LOG:

15:30UTC Observing and Locked for over 7.5 hours
    15:52 Out of Observing due to SQZ unlock
    15:56 Back into Observing
    21:29 GRB-Short E617667

Start Time System Name Location Lazer_Haz Task Time End
16:00 FAC Randy YTube n Caulking up those joints 22:57
17:04 FAC Kim MX n Tech clean 18:34
18:21   Sheila. Kar Meng Optics Lab y(local) OPO prep (Sheila out 18:57) 19:10
18:51 VAC Gerardo MX n Looknig for case 20:07
20:09   Corey OpticsLab n Cleaning optics 23:33
21:26   Kar Meng Optics Lab y(local) OPO prep 23:28
22:01   RyanS OpticsLab n Cleaning optics 23:33
22:10   TJ Optics Lab n Spying on Corey and RyanS 22:22
22:59   Matt Optics Lab n Grabbing wipes 23:16
23:34   Matt Prep Lab n Putting wipes away 23:35
Comments related to this report
david.barker@LIGO.ORG - 17:08, Wednesday 12 November 2025 (88080)

Tyler has the reverse osmosis water conditioning system offline overnight. The CDS alarms system has an active cell-phone bypass for this channel which expires tomorrow afternoon. This should be the only channel in CDS ALARM.

Bypass will expire:
Thu Nov 13 05:05:22 PM PST 2025
For channel(s):
    H0:FMC-CS_WS_RO_ALARM
 

LHO General
ryan.short@LIGO.ORG - posted 16:02, Wednesday 12 November 2025 (88078)
Ops Eve Shift Start

TITLE: 11/13 Eve Shift: 0030-0600 UTC (1630-2200 PST), all times posted in UTC
STATE of H1: Observing at 148Mpc
OUTGOING OPERATOR: Oli
CURRENT ENVIRONMENT:
    SEI_ENV state: USEISM
    Wind: 5mph Gusts, 3mph 3min avg
    Primary useism: 0.04 μm/s
    Secondary useism: 0.56 μm/s 
QUICK SUMMARY: H1 has been locked for 16 hours and observing the whole day.

LHO VE
david.barker@LIGO.ORG - posted 11:52, Wednesday 12 November 2025 (88077)
Wed CP1 Fill

Wed Nov 12 10:08:17 2025 INFO: Fill completed in 8min 13secs

Gerardo confirmed a good fill curbside.

Images attached to this report
H1 AOS
oli.patane@LIGO.ORG - posted 09:18, Wednesday 12 November 2025 (88075)
ISI CPS Noise Spectra Check Weekly FAMIS

Closes FAMIS#27534, last checked 87787

I was supposed to do this last week but I was out, so doing it now. Last time it was done was 10/28, so this is comparing to measurements from two weeks ago.

Nothing of note, everything looks very similar to how it looked a couple weeks ago.

Non-image files attached to this report
H1 General
oli.patane@LIGO.ORG - posted 07:38, Wednesday 12 November 2025 - last comment - 07:45, Wednesday 12 November 2025(88073)
Ops Day Shift Start

TITLE: 11/12 Day Shift: 1530-0030 UTC (0730-1630 PST), all times posted in UTC
STATE of H1: Observing at 148Mpc
OUTGOING OPERATOR: Ibrahim
CURRENT ENVIRONMENT:
    SEI_ENV state: CALM
    Wind: 3mph Gusts, 1mph 3min avg
    Primary useism: 0.05 μm/s
    Secondary useism: 0.37 μm/s 
QUICK SUMMARY:

Observing at 148 Mpc and have been Locked for over 7.5 hours. Currently in a standdown due to Superevent S251112cm that came in at 11/12 15:19 UTC

Comments related to this report
oli.patane@LIGO.ORG - 07:45, Wednesday 12 November 2025 (88074)

Looks like we had a few events come in last night besides the superevent:

11/12 06:29 UTC GRB-Short E617425

11/12 13:35 UTC GRB-Short E617519

X1 General
jeffrey.kissel@LIGO.ORG - posted 16:13, Thursday 09 October 2025 - last comment - 12:05, Thursday 13 November 2025(87397)
All 1064 [nm] HR, 45 deg AOI Optics from C2500044 Coating Run Etched with Wrong Coating Spec DCC Number
J. Kissel, C. Gray, M. Nakano, G. Billingsley

We're getting started with cleaning our 1" and 2" optics for SPI. Corey uploaded *all* of our optics (50:50 BSs, 85:15 BSs, TFPs, HR mirrors, Lenses etc.) to ICS in prep, and I reviewed the work double checking that the ICS record information makes sense. For the HR mirrors, which were part of the 2025 large custom purchase order (C2500044) from FiveNine Optics (to be used by JAC, SQZ, the LLO TNT Lab, and SPI), he entered them into ICS with a key that used the DCC number that's physically etched into the barrel of the optic.

HOWEVER -- the DCC number etched on the barrel of the optic is E1900393 -- E1900393. See attached picture. 

That drawing number is for the coating spec of 0-25 deg AOI HR mirrors.

The physical coating spec we want, was provided, and bought was for 45 deg AOI, i.e. E1900392 -- E1900392 (one DCC number lower).

So these HR optics, coated with E1900392 spec, bought with C2500044, which have vendor run numbers 1895 and 1897, have the incorrect DCC number for the spec etched on the barrel.

If you head to the purchase order, C2500044, and look at the FNO_4787-1.pdf attachment, it clearly states (twice!)
    "[...] per drawing E1900392-V2. Serialization per E1900392-V2."

However, if you then *read* E1900392-v2, section 8 states equally clearly
    "Each optic should be serialized and marked with the following code/description:
        1" optics: E1900393-v2-01 S/N:01 HR1064+532
            with incremental S/N: 01, 02, 03, ...
        2" optics: E1900393-v2-02 S/N:01 HR1064+532
            with incremental S/N: 01, 02, 03, ..."

Thankfully we know the coating is the correct E1900392 coating --
(1) The PCAL team confirms via measurement at 45 deg AOI, that these have transmission at the level of ~5e-5 W/W, so these will serve excellently as HR mirrors at 45 deg AOI. See LHO:86699
(2) The vendor's data, posted to C2500186, (Even though the run numbers listed on the first page of the data for the First Batch are quoted as "V2-2895" and "V2-1897" we know the run numbers are V2-1895 and 1897 from what's written on the containers the optics came in; see attached picture) show figures with captions indicating the data is from AoIs of 38, 45, and 50 deg, a reasonable range of AoI's to test for a 45 deg AoI mirror; and conversely no measurement of anything at AoIs less than 25 deg, which would be what one would report for a coating that's spec'd with the *actual* E1900393 spec.
(3) The E1900392 spec specificies a 45 deg AoI.

So, now we just have to figure out how to keep track of this information when we're in the lab / in the chamber, 5 years later, and the optics are no where near their cases and a brand new person is using the optics. C'est le vie!
Images attached to this report
Comments related to this report
corey.gray@LIGO.ORG - 10:26, Tuesday 28 October 2025 (87791)

Bookkeeping UPDATE:

After consulting with Mitch R. & Dwayne G. about the confusion here, I asked Dwayne to DELETE  the qty8 HR mirrors (etch-labeled with the INCORRECT part number of E1900393).  So now the ICS permalink Jeff notes above in alog 87397 will no longer point to any parts in ICS.  Dwayne made an FRS 35768 for this.

I then imported these NEW ICS parts for the qty-8 MIS-LABELED optics (new permalink list) and gave them the correct Part # they were manufactured/coated for of E1900392

-PLUS-

added a comment to all 8-parts stating they are mislabeled.  (comment is:  "note:  this optic is etch-labeled with the --WRONG-- part number (E1900393), these are in fact E1900392 and have been tested as such.  See https://alog.ligo-wa.caltech.edu/aLOG/index.php?callRep=87397.").

corey.gray@LIGO.ORG - 12:05, Thursday 13 November 2025 (88092)

Another bookkeeping mistake found (RyanS noticed that in ICS I marked all the 50/50 splitters with the wrong batch number.  Deleted these parts from ICS and just re-uploaded with the correct batch number.  We will also update their PETG containers and bags with the correct batch.  (this is an easy fix unlick the errant ones which had the physical error etched on the optics themselves IRL).

Yet again, the permalink for the SPI optics has been updated.  It is now this permalink.

H1 GRD (CDS)
thomas.shaffer@LIGO.ORG - posted 14:53, Tuesday 14 January 2025 - last comment - 10:17, Wednesday 12 November 2025(82273)
h1guardian1 machine reboot and point back at nds0

WP12274

FAMIS28946

We rebooted the h1guardian1 machine today for 3 things:

  1. Point the machine back at nds0 as the primary nds server
    • I noticed the other day that the guardian was still defining the chosen nds server as nds1 primary and nds0 as secondary. I'm not entirely sure when this was changed, but maybe 2 years ago (alog66834).
    • This was done by changing the NDSSERVER definition in the /etc/guardian/local-env file
  2. Relieve any stale processes that might latch the gps leap second data.
  3. Quarterly machine reboot FAMIS task

All 168 nodes came back up and Erik confirmed that nds0 was seeing the traffic after the machine reboot.

Comments related to this report
erik.vonreis@LIGO.ORG - 10:17, Wednesday 12 November 2025 (88076)

Server order is set in the guardian::lho_guardian profile in puppet.

Displaying reports 3501-3520 of 89075.Go to page Start 172 173 174 175 176 177 178 179 180 End