Reports until 12:41, Thursday 16 October 2025
H1 CAL
elenna.capote@LIGO.ORG - posted 12:41, Thursday 16 October 2025 (87520)
Pushed calibration report 20251016T180834Z

Today I pushed calibration report 20251016T180834Z which was just taken in alog 87512. My motivation was due to what appears to be an incorrect kappa c value that I reported here 87453. We have also moved the beam spot on ETMY due to a camera bump, reported here 87473 and here 87508.

Note, I did not update the L3 drivealign gain in the model. That number is still changed in the actual suspension gain, but not in CALCS or in the pydarm ini file.

I also noticed that, maybe due to the beamspot change, there is an antispring present in the sensing function that maybe we should correct.

I followed the usual steps to commit, upload and export. I loaded the calcs model and accepted the SDF diffs. I confirmed things look good by checking the broadband measurement. Calibration is within +-2%. Kappa C is back to 1-ish. This is not as good as the Aug 28 push, but it's still pretty good overall.

Images attached to this report
H1 SUS (DetChar, SUS)
ryan.crouch@LIGO.ORG - posted 12:01, Thursday 16 October 2025 - last comment - 11:29, Thursday 23 October 2025(87515)
OPS Thursday DAY shift update

18:45 UTC While Jim was running a measurement on ISI HAM5, SUS ITMY started to flash its' red Rocker Switch Death on L2 and report that its' L2 OSEMs were in fault, we also noticed there's a big new line at ~92Hz. Jeff turned off feedback from L2. It looks like it could be a sat amp issue, the L2 sat amp was upgraded this past Tuesday alog87469. Jeff is starting to work on characterizing a sat amp box in the EE shop to swap in. 

We would need a lockloss to swap this component.

We are going to try to go back into Observing for a bit until we can fix it or lose lock.

Images attached to this report
Comments related to this report
ryan.crouch@LIGO.ORG - 12:31, Thursday 16 October 2025 (87519)

19:31 UTC Observing

jeffrey.kissel@LIGO.ORG - 13:52, Thursday 16 October 2025 (87524)DetChar, DetChar-Request, ISC, Lockloss, OpsInfo
FYI -- we went into observing with the ITMY PUM sat amp OSEM PD's still dead. We turned OFF the ITMY L2 (PUM) to R0 "damping" feedback loop, so the failed sensors *should* not have any impact on the IFO. However, an obvious, loud ~92-93 Hz feature remained new and glaringly obvious in the DARM sensitivity. 

@DetChar / @CW Group Probably best to just veto this observation stretch, unless we -- in the future -- find some amazingly exceptional event. 
     2025-10-16 19:31 UTC to 19:54 UTC.
filiberto.clara@LIGO.ORG - 11:29, Thursday 23 October 2025 (87687)

ITMY L2 (PUM) Sat Amp S1100148 installed on 10/14/2025. Replaced on 10/16/2024 with S1100080.

https://alog.ligo-wa.caltech.edu/aLOG/index.php?callRep=87469

H1 SUS (ISC, SUS)
jeffrey.kissel@LIGO.ORG - posted 12:00, Thursday 16 October 2025 - last comment - 14:08, Thursday 16 October 2025(87511)
All QUADs L2 to R0 Damping, PITCH/ROLL (Before vs. After L2 OSEM PD Sat Amp Whitening Upgrade)
J. Kissel

This past Tuesday (Oct 14 2025), we upgraded the L2 (PUM) OSEM PD Sat Amps to improve their whitening filter, per ECR E2400330; see LHO:87469. These QUAD L2 PUM OSEMs (in which the flags are on the QUADs main chain PUM, and the LED & PD are on the reaction chain PUM [aka the "PenRe"]) are used in feedback. This "damping" of a "3.3" Hz reaction chain resonance is different ITMs and ETMs (ITM Install = LHO:65728; ETMs Install = LHO:68012 --- commissioning of both = LHO:68200); the ITM has resonances at 3.28 / 3.31 Hz and the ETM has modes at 3.18 Hz / 3.42 Hz.

Because the improved sat amps come with better compensation of the whitening filter frequency response, we know that the frequency dependent gain on each channel -- especially around 3.3 Hz may change by as much as ~10%. 

In the aLOG (and comments collection) I report 
    (a) That we *did* see a change in the open loop gain TFs of these loops, but (after ~2 days of observing since the upgrade) the IFO doesn't seem to mind the changes.
    (b) We were able to get better coherence on the open loop gain TFs in the 0.1 to 10 Hz region because of the sat amp whitening improvement
    (c) A comparison between all four QUAD's PITCH and YAW damping, so that we might understand them better and potentially improve them.

In this main aLOG I show the comparison between the PITCH and ROLL open loop gain TFs and loop suppression for all four QUADs.

Rushed commentary:
    - The surprising thing to me is that we're getting gain peaking and/or some suppression of other modes below 1 Hz, which I'm confident was not the design intent.
    - Even though the filters and EPICs gains are the same for EX and EY, ETMX has a lot more open loop gain below 1 Hz.
    - Also though the ETM loop suppression is about the same on these 3.18 / 3.42 Hz, the ITM loops have pretty different amount of gain peaking.
    - I'm guessing we *don't* want this much sharp gain peaking just *off* the "3.3" Hz mode.
Images attached to this report
Comments related to this report
jeffrey.kissel@LIGO.ORG - 12:47, Thursday 16 October 2025 (87521)
Here's the EPICs configurations, gains, and frequency response for L2DAMP filters. In foton, I added a temporary filter that multiplied in the EPICs gain in use (including the sign) for plotting/comparison purposes. 

As shown, the ITM filter and overall gain design is identical between ITMX and ITMY, and the ETM filter design and overall gain is identical between ETMX and ETMY.
Images attached to this comment
jeffrey.kissel@LIGO.ORG - 13:13, Thursday 16 October 2025 (87522)
ITMX Before vs. After Sat Amp Swap Open Loop Gain and Loop Suppression plots for PITCH and ROLL.

As advertised -- no substantial change. The overall magnitude of PITCH open loop gain dropped by 18% between 0.5 and 3 Hz, but I suspect this is actually a clean-up of the compensation or frequency dependent calibration rather than a "real" gain drop. Since this all happens below the intended functional frequency, there's little to no change in functional loop suppression, save a little bit *less* gain peaking at 3.3 Hz.

The templates for taking this this before vs. after data lives in
    /ligo/svncommon/SusSVN/sus/trunk/QUAD/H1/ITMX/SAGR0/Data/
        2025-10-14_1830UTC_H1SUSITMX_R0_WhiteNoise_0p02to50Hz_L2DAMP_OLGTF_P.xml
        2025-10-14_1830UTC_H1SUSITMX_R0_WhiteNoise_0p02to50Hz_L2DAMP_OLGTF_R.xml

and to make the comparison in the main aLOG entry, I exported the results to 
    /ligo/svncommon/SusSVN/sus/trunk/QUAD/H1/ITMX/SAGR0/Data/
        2025-10-14_1830UTC_H1SUSITMX_R0_WhiteNoise_0p02to50Hz_L2DAMP_OLGTF_P_LoopSuppression_tf.txt
        2025-10-14_1830UTC_H1SUSITMX_R0_WhiteNoise_0p02to50Hz_L2DAMP_OLGTF_P_OpenLoopGain_tf.txt
        2025-10-14_1830UTC_H1SUSITMX_R0_WhiteNoise_0p02to50Hz_L2DAMP_OLGTF_R_LoopSuppression_tf.txt
        2025-10-14_1830UTC_H1SUSITMX_R0_WhiteNoise_0p02to50Hz_L2DAMP_OLGTF_R_OpenLoopGain_tf.txt
Images attached to this comment
jeffrey.kissel@LIGO.ORG - 13:54, Thursday 16 October 2025 (87525)
ITMY Before vs. After Sat Amp Swap Open Loop Gain and Loop Suppression plots for PITCH and ROLL.

Even less change than ITMX -- arguably none at all to within the precision [i.e. coherence] of the measurement.

The templates for taking this this before vs. after data lives in
    /ligo/svncommon/SusSVN/sus/trunk/QUAD/H1/ITMY/SAGR0/Data/
        2025-10-14_1830UTC_H1SUSITMY_R0_WhiteNoise_0p02to50Hz_L2DAMP_OLGTF_P.xml
        2025-10-14_1830UTC_H1SUSITMY_R0_WhiteNoise_0p02to50Hz_L2DAMP_OLGTF_R.xml

and to make the comparison in the main aLOG entry, I exported the results to 
    /ligo/svncommon/SusSVN/sus/trunk/QUAD/H1/ITMY/SAGR0/Data/
        2025-10-14_1830UTC_H1SUSITMY_R0_WhiteNoise_0p02to50Hz_L2DAMP_OLGTF_P_LoopSuppression_tf.txt
        2025-10-14_1830UTC_H1SUSITMY_R0_WhiteNoise_0p02to50Hz_L2DAMP_OLGTF_P_OpenLoopGain_tf.txt
        2025-10-14_1830UTC_H1SUSITMY_R0_WhiteNoise_0p02to50Hz_L2DAMP_OLGTF_R_LoopSuppression_tf.txt
        2025-10-14_1830UTC_H1SUSITMY_R0_WhiteNoise_0p02to50Hz_L2DAMP_OLGTF_R_OpenLoopGain_tf.txt
Images attached to this comment
jeffrey.kissel@LIGO.ORG - 14:03, Thursday 16 October 2025 (87526)
ETMX Before vs. After Sat Amp Swap Open Loop Gain and Loop Suppression plots for PITCH and ROLL.

Arguably no change -- and the measurement coherence is better *after* in the 0.5 to 5 Hz band because of the improved whitening on the L2 OSEM PDs.

The templates for taking this this before vs. after data lives in
    /ligo/svncommon/SusSVN/sus/trunk/QUAD/H1/ETMX/SAGR0/Data/
        2025-10-14_1830UTC_H1SUSETMX_R0_WhiteNoise_0p02to50Hz_L2DAMP_OLGTF_P.xml
        2025-10-14_1830UTC_H1SUSETMX_R0_WhiteNoise_0p02to50Hz_L2DAMP_OLGTF_R.xml

and to make the comparison in the main aLOG entry, I exported the results to 
    /ligo/svncommon/SusSVN/sus/trunk/QUAD/H1/ETMX/SAGR0/Data/
        2025-10-14_1830UTC_H1SUSETMX_R0_WhiteNoise_0p02to50Hz_L2DAMP_OLGTF_P_LoopSuppression_tf.txt
        2025-10-14_1830UTC_H1SUSETMX_R0_WhiteNoise_0p02to50Hz_L2DAMP_OLGTF_P_OpenLoopGain_tf.txt
        2025-10-14_1830UTC_H1SUSETMX_R0_WhiteNoise_0p02to50Hz_L2DAMP_OLGTF_R_LoopSuppression_tf.txt
        2025-10-14_1830UTC_H1SUSETMX_R0_WhiteNoise_0p02to50Hz_L2DAMP_OLGTF_R_OpenLoopGain_tf.txt
Images attached to this comment
jeffrey.kissel@LIGO.ORG - 14:08, Thursday 16 October 2025 (87527)
ETMY Before vs. After Sat Amp Swap Open Loop Gain and Loop Suppression plots for PITCH and ROLL.

Similar to ETMX -- arguably no change at all in open loop gain or loop suppression to within the measurement precision i.e. coherence.

The templates for taking this this before vs. after data lives in
    /ligo/svncommon/SusSVN/sus/trunk/QUAD/H1/ETMY/SAGR0/Data/
        2025-10-14_1830UTC_H1SUSETMY_R0_WhiteNoise_0p02to50Hz_L2DAMP_OLGTF_P.xml
        2025-10-14_1830UTC_H1SUSETMY_R0_WhiteNoise_0p02to50Hz_L2DAMP_OLGTF_R.xml

and to make the comparison in the main aLOG entry, I exported the results to 
    /ligo/svncommon/SusSVN/sus/trunk/QUAD/H1/ETMY/SAGR0/Data/
        2025-10-14_1830UTC_H1SUSETMY_R0_WhiteNoise_0p02to50Hz_L2DAMP_OLGTF_P_LoopSuppression_tf.txt
        2025-10-14_1830UTC_H1SUSETMY_R0_WhiteNoise_0p02to50Hz_L2DAMP_OLGTF_P_OpenLoopGain_tf.txt
        2025-10-14_1830UTC_H1SUSETMY_R0_WhiteNoise_0p02to50Hz_L2DAMP_OLGTF_R_LoopSuppression_tf.txt
        2025-10-14_1830UTC_H1SUSETMY_R0_WhiteNoise_0p02to50Hz_L2DAMP_OLGTF_R_OpenLoopGain_tf.txt
Images attached to this comment
H1 CAL
ryan.crouch@LIGO.ORG - posted 11:38, Thursday 16 October 2025 - last comment - 12:28, Thursday 16 October 2025(87512)
Thursday calibration measurement

Broadband:

Start: 2025-10-16 18:01:42 UTC

Stop: 2025-10-16 18:06:53 UTC

Files: /ligo/groups/cal/H1/measurements/PCALY2DARM_BB/PCALY2DARM_BB_20251016T180142Z.xml

Simulines:

Start: 2025-10-16 18:08:33 UTC // 1444673331.797786 GPS

Stop: 2025-10-16 18:31:47 UTC // 1444674725.604456 GPS

Files:

2025-10-16 18:31:47,448 | INFO | File written out to: /ligo/groups/cal/H1/measurements/DARMOLG_SS/DARMOLG_SS_20251016T180834Z.hdf5
2025-10-16 18:31:47,456 | INFO | File written out to: /ligo/groups/cal/H1/measurements/PCALY2DARM_SS/PCALY2DARM_SS_20251016T180834Z.hdf5
2025-10-16 18:31:47,461 | INFO | File written out to: /ligo/groups/cal/H1/measurements/SUSETMX_L1_SS/SUSETMX_L1_SS_20251016T180834Z.hdf5
2025-10-16 18:31:47,466 | INFO | File written out to: /ligo/groups/cal/H1/measurements/SUSETMX_L2_SS/SUSETMX_L2_SS_20251016T180834Z.hdf5
2025-10-16 18:31:47,471 | INFO | File written out to: /ligo/groups/cal/H1/measurements/SUSETMX_L3_SS/SUSETMX_L3_SS_20251016T180834Z.hdf5

Images attached to this report
Non-image files attached to this report
Comments related to this report
elenna.capote@LIGO.ORG - 11:49, Thursday 16 October 2025 (87514)

Once again, it pulled the wrong report, regenerated.

Non-image files attached to this comment
elenna.capote@LIGO.ORG - 12:08, Thursday 16 October 2025 (87516)

I regenerated again after changing "prospring" to FALSE. This report includes GDS filters because we are going to push.

Non-image files attached to this comment
ryan.crouch@LIGO.ORG - 12:28, Thursday 16 October 2025 (87518)

I ran a second PCAL broadband.

Start: 2025-10-16 19:20:36 UTC

Stop: 2025-10-16 19:25:46 UTC

File: /ligo/groups/cal/H1/measurements/PCALY2DARM_BB/PCALY2DARM_BB_20251016T192036Z.xml

H1 ISC
elenna.capote@LIGO.ORG - posted 10:45, Thursday 16 October 2025 (87508)
Moving ETMY beam spot (again)

Since we are still not happy with our buildups, I moved the ETMY beam spot again, following the assumption that this camera was bumped on Tuesday.

Instead of considering the A2L gains or ADS, I just chose to move the spot around by hand to make the buildups better. I did so slowly in pitch and then in yaw. Overall, the final camera offsets are P: -224 and Y: -346. This offsets brought the PRG up to 49.5 and the arm powers up to 380 "kW". I also noticed that this change brought the Y arm power up slightly about the X arm power, which is how it used to be before whatever happened on Tuesday.

Once the cameras converged on these new values, I ran the A2L script. This was a large beam shift for ETMY, so I had to run it a few times to get the script to cross zero for the ETMY lines. I would run it, guess where to go next, and rerun. Sheila pointed out to me that if you scroll up in the script output, it will tell you where it thinks the zero crossing is. I was able to use this to guess the final position. I reran one more time to see the script cross zero on all dofs, confirming that the A2L gains ended up in the right spot.

As a part of this, I was able to test TJ's new version of this script, /opt/rtcds/userapps/release/isc/h1/scripts/a2l/a2l_min_multi_sdf_cleanup.py

His script now does not leave SDF diffs, since it reverts all the tramps and matrices. However, when I cntrl-Ced, only half the lines turned off. It appears that cntrlC only turns off the matrix values for pitch, but not yaw, and it still leaves the clkgains and such in place. So the cntrlC capability needs more work. To get the scrpt to revert everything properly, you still need to let it fully run.

I updated the guardian lscparams to have these new ETMY A2Ls (P: 4.89, Y: 0.78) and camera offsets. I have loaded both the ISC_LOCK and the CAMERA_SERVO guardians.

While these A2Ls suggest that the ETMY spot has not ended up in the same place as before, I do believe this is a good place that gives us good buildups, so I think this is a fine spot to be in.

First run:

Optic DOF Initial Final Diff
ETMX P 3.13 3.13 0
ETMX Y 4.85 4.9 0.05
ETMY P 6.43 6.43 0
ETMY Y 1.37 1.37 0
ITMX P -0.45 -0.45 0
ITMX Y 3.16 3.15 -0.01
ITMY P 0.19 0.2 0.01
ITMY Y -2.75 -2.74 0.01

Second try I cntrl-Ced which sort of worked.

Third try:

Optic DOF Initial Final Diff
ETMX P 3.12 3.12 0
ETMX Y 4.89 4.9 0.01
ETMY P 4.89 4.89 0
ETMY Y 0.78 0.78 0
ITMX P -0.46 -0.46 0
ITMX Y 3.15 3.16 0.01
ITMY P 0.19 0.19 0
ITMY Y -2.74 -2.74 0
Images attached to this report
H1 PEM
ryan.crouch@LIGO.ORG - posted 10:44, Thursday 16 October 2025 (87510)
New dust monitors arrived and are being tested

I received our first units of a new brand of dust monitors (Temtop instead of MetOne) that we are going to test replacing the current MetOne GTs with. I got 2 different units, the PMD331 (handheld,  remote capable, pump less option available) and the PMS21 (fixed remote monitoring, no internal battery pack, pump less option available). Fil made me a custom 24v power cable for the PMD331 using its 5 pin terminal block, as it didn't come with one.

Both of the dust monitors passed their zero count and flow rate calibration checks right out of the box, the PMS21 requires a password to get to the settings menu (543210).

I have them running in the corner of the control room for right now.

Their serials are as follows;

PMD331: TD3350722828

PMS21: TM2150918004

Images attached to this report
LHO VE
david.barker@LIGO.ORG - posted 10:11, Thursday 16 October 2025 (87509)
Thu CP1 Fill

Thu Oct 16 10:04:38 2025 INFO: Fill completed in 4min 35secs

Jordan confirmed a good fill curbside.

Images attached to this report
H1 General
ryan.crouch@LIGO.ORG - posted 07:34, Thursday 16 October 2025 - last comment - 08:48, Thursday 16 October 2025(87491)
OPS Thursday day shift start

TITLE: 10/16 Day Shift: 1430-2330 UTC (0730-1630 PST), all times posted in UTC
STATE of H1: Lock Acquisition
OUTGOING OPERATOR: Ibrahim
CURRENT ENVIRONMENT:
    SEI_ENV state: CALM
    Wind: 3mph Gusts, 2mph 3min avg
    Primary useism: 0.01 μm/s
    Secondary useism: 0.14 μm/s 
QUICK SUMMARY:

Comments related to this report
ryan.crouch@LIGO.ORG - 08:14, Thursday 16 October 2025 (87504)CDS, Lockloss

Locklosses aren't updating again, it didn't catch the one this morning at 13:01. The DARM fom has timed out three times this morning as well (tagging CDS).

ryan.crouch@LIGO.ORG - 08:48, Thursday 16 October 2025 (87507)

15:30 UTC The PI around 10.2kHz rung up but damped back down, it was smaller than the last 3 times we witnessed it since maintenance.

Images attached to this comment
H1 General
ibrahim.abouelfettouh@LIGO.ORG - posted 03:50, Thursday 16 October 2025 - last comment - 08:47, Monday 20 October 2025(87503)
OPS OWL Shift: DRMI Lock Issues

Got called at 3:30AM due to DRMI lock unable to lock. Flashes seem bad since the earthquake and there hasn't been an initial alignment for some reason. Set IFO to initially align then turned the manager back on.

Comments related to this report
thomas.shaffer@LIGO.ORG - 08:47, Monday 20 October 2025 (87577)

Looking further into this, it did run initial alignment before it called Ibrahim, but there were two DRMI lock losses and one regular lock loss before it called. Looks like there was a large nearby earthquake that caused the lock loss and also perhaps didn't help the initial alignment, causing Ibrahim to have to run a second one. I'll need to look further into that.

Images attached to this comment
LHO VE (VE)
gerardo.moreno@LIGO.ORG - posted 01:48, Thursday 16 October 2025 (87502)
Annulus Ion Pump for BSC9 Rails

BSC9 annulus ion pump (AIP) railed yesterday around 6:05 pm local time, railing is noted on the plot with the red trace.  The annulus system will be diagnosed on next opportunity.
After the pump railed there is no noted effect inside the main vacuum envelope, noted on the green trace on the attached plot.

The current ion pump body was replaced on September 2015, see aLOG entry here.

Images attached to this report
H1 General
oli.patane@LIGO.ORG - posted 22:02, Wednesday 15 October 2025 (87501)
Ops EVE Shift End

TITLE: 10/16 Eve Shift: 2330-0500 UTC (1630-2200 PST), all times posted in UTC
STATE of H1: Observing at 156Mpc
INCOMING OPERATOR: Ibrahim
SHIFT SUMMARY: Observing at 156 Mpc and have been Locked for just over 15 hours. The only thing that happened during my shift was the earthquake and needing to transition to ASC Hi Gain, but besides that we've just been Observing.
LOG:

23:00UTC Observing and Locked for 9 hours
02:38 Earthquake mode activated due to incoming 6.3 EQ
    02:39 Left Observing to go to ASC HI Gain
    03:08 Back to CALM
03:09 Reverted ASC Hi Gains and went back into Observing

Start Time System Name Location Lazer_Haz Task Time End
19:55 PSL Keita Optics lab N ISS array, Laser Safe 23:57
20:13 PSL Jennie Optics lab N Join Keita 23:57
21:19 PSL Rahul Optics lab N Join Keita 23:57
H1 General
oli.patane@LIGO.ORG - posted 20:25, Wednesday 15 October 2025 (87500)
Ops EVE Midshift Status

Currrently Observing at 155 Mpc and have been Locked for almost 13.5 hours. We had a 6.3 earthquake from the Drake Passage roll through a bit ago - we had to go to earthquake mode and I dropped Observing to go to ASC Hi Gains, but we rode the earthquake out easily (it also didn't hit us as bad as expected - see three). We've been back in Observing for about 15 minutes now.

Images attached to this report
H1 IOO (ISC, PSL)
jennifer.wright@LIGO.ORG - posted 14:00, Tuesday 14 October 2025 - last comment - 08:24, Thursday 16 October 2025(87466)
ISS measurements - 10th -14th October

Jennie W, Keita, Rahul

 

On Friday, Keita and Rahul and I tried moving PDs 2 and 6 to align them better with the others. As can be seen from the scans we did of the DC voltage of the diodes as we moved the input alignemnt in horizontal translation and yaw from alog #87290, 2 and 6 have a range of alignment that is shifted relative to the other 6.

We also checked this with a IR sensitive camera with a zoom lens.

One person used the camera with a zoom lens to check the spot on the PDs as another person loosened the screws from behind the array and the third person held the barrel of the PD assembly to stop it moving or rotating in an undesired direction.

There is not a lot of space as 2 and 6 are in a column and are very close to diodes 1 and 5 on the right.

The horizontal scan we took after these moves showed we had made things worse, see this image.

Later that afternoon, Keita moved the PD 2 back and checked the alignment and it looks better.


The alignment as of yesterday (Monday) was 143mm in pitch (as read out by the allen key in the PZT mirror pitch actuator wheel) and 0.4145 inches in horizontal translation as read out by the translation stage the PZT mirror sits on.

Keita measured the coupling (after finding an error in my code from the previous coupling measurement I plotted last Thursday (alog #87400)).

The coupling in both vertical and horizontal is below 10, so this should be good enough for install if all else checks out.

 

Yesterday afternoon, Rahul and I did the vertical scan (slightly off from the horizontal reference position of 0.4145 inches that Keita had aligned to). The data in this graph was collected at a horizontal translation stage reading of 0.4162 inches.

We had to redo the horizontal scan today as I missed out some scan values yesterday. The data was collected with the pitch indicator at 143mm (the allen key on the pitch wheel actuator).

 

Images attached to this report
Comments related to this report
jennifer.wright@LIGO.ORG - 11:20, Wednesday 15 October 2025 (87471)

This morning Rahul recentred the QPD on the input beam (translation stage = 0.4145 inches, allen key - 143mm) and we scanned the translation stage horizontally to measure the calibration of the QPD.

This first scan had too large steps to give a good estimate of the slope for the X coordinate on the QPD near the centre, so I repeated the measurement with smaller steps. Although I thought I set the laser to ~120 mA for both measurements the power on the QPD sum was slightly different between the two, see this plot where the original measurement set is in orange and the second set in blue.

Looking at the plot the QPD has the same slope in Y for both measurements but the second set of Y measurements has lower voltages.

The X data overlaps between the two measurements which makes more sense to me, as we assume the QPD electronics normalise the readout of X and Y by the sum channel to account for power fluctuations.

I used the newer measurement to estimate the calibration in the x direction, and the older measurement to estimate the slope in the y-direction, I tried to only use the linear part of the data in my fit and also not use any points with a voltage abive 6 Volts as this is when we expect the QPD to not be linear.

The calibration plot is here with the X calibration line in orange and the Y calibration line in red.

The resultant calibration is 72.0 V/mm in the horizontal direction, at an angle of 7.4 deg with the QPD axis. This is similar to the last calibration we did before several moves of the QPD to recentre it, see alog  #87375

This is worked out by adding the two slopes in quadrature and using atan2(Y_calib/X_calib) to work out the angle of the QPD axis with the horizontal direction of the PZT mirror translation.

Images attached to this comment
rahul.kumar@LIGO.ORG - 08:24, Thursday 16 October 2025 (87505)

Attaching a picture of the recentered QPD on the input beam.

Images attached to this comment