Displaying reports 4201-4220 of 89162.Go to page Start 207 208 209 210 211 212 213 214 215 End
Reports until 07:33, Tuesday 14 October 2025
H1 General
ryan.crouch@LIGO.ORG - posted 07:33, Tuesday 14 October 2025 - last comment - 07:59, Tuesday 14 October 2025(87455)
Ops Tuesday day shift start

TITLE: 10/14 Day Shift: 1430-2330 UTC (0730-1630 PST), all times posted in UTC
STATE of H1: Lock Acquisition
OUTGOING OPERATOR: TJ
CURRENT ENVIRONMENT:
    SEI_ENV state: CALM
    Wind: 15mph Gusts, 10mph 3min avg
    Primary useism: 0.04 μm/s
    Secondary useism: 0.26 μm/s 
QUICK SUMMARY:

Comments related to this report
ryan.crouch@LIGO.ORG - 07:41, Tuesday 14 October 2025 (87456)

There was a small typo in inj_params in fm_dict that I found and fixed and reloaded.

ryan.crouch@LIGO.ORG - 07:59, Tuesday 14 October 2025 (87457)SQZ

SQZ_OPO reports "pump fiber rej power in ham7 high" so I get to try adjusting that today.

LHO General (SQZ)
ibrahim.abouelfettouh@LIGO.ORG - posted 22:04, Monday 13 October 2025 (87454)
OPS Eve Shift Summary

TITLE: 10/14 Eve Shift: 2330-0500 UTC (1630-2200 PST), all times posted in UTC
STATE of H1: Observing at 151Mpc
INCOMING OPERATOR: TJ
SHIFT SUMMARY:

IFO is in NLN and OBSERVING (~10 hr lock)

2:53 - SQZ Dropped

4:10 - SQZ recovered, back to OBS

Mostly quiet shift except for the SQZ dropping due to FC lockloss.

The Squeezer FC lost lock due to FC2 alignment walking away from a lockable GR_LOCKED configuration. As per the wiki, I trended the last time we had a stable lock and reset values for FC1, FC2 and ZM3 (P/Y). Then, I tuned FC2 a bit more to maximize GR_TRANS output. This worked.

Interestingly, I first tried an alignment from a few days ago but this didn't work. I did this because FC2 has been increasing quite a bit in the last few days (screenshots) - probably worth looking into. The values I set FC suspensions to (using opticalign sliders)

FC2 P: 1558, FC2 Y: 109.6 

FC1 P: -899.6, FC1 Y: -74

ZM3 P: -66.25 ZM3 Y: -463

I hope this issue doesn't happen again during OWL shift though the trend below from a few days ago shows FC2 P going up for the last few days seemingly with SQZ compensating in its alignment. Anecdotally, it seems related to the temperature since there's a diurnal breathing day to day (lows at night, highs in the day). Tagging SQZ to look at FC2 and FC.

LOG:

 

Images attached to this report
LHO General
thomas.shaffer@LIGO.ORG - posted 16:25, Monday 13 October 2025 (87436)
Ops Day Shift End

TITLE: 10/13 Day Shift: 1430-2330 UTC (0730-1630 PST), all times posted in UTC
STATE of H1: Observing at 150Mpc
INCOMING OPERATOR: Ibrahim
SHIFT SUMMARY: Locked for 4 hours. We had one lock loss during commissioning time today, though it does not seem to be caused by any commissioning activites. useism is on its way up, and the wind is gusting above 30mph at times. 
LOG:

Start Time System Name Location Lazer_Haz Task Time End
22:52 SAF Laser HAZARD LVEA YES LVEA is Laser HAZARD 13:52
14:36 FAC Randy Yarm n Y arm bte checks 18:36
14:46 FAC Kim Opt Lab n Tech clean 15:10
14:59 FAC Nelly MY n Tech clean 15:50
15:11 FAC Kim MX n Tech clean 16:05
15:33 ISC Matt Prep lab n Cheeta table prep 15:46
16:38 FAC Kim Prep lab n Table clean 17:09
16:50 ISC Keita Opt Lab YES ISS array work 20:54
17:01 SYS Mitchell MY n Checking out equipment 17:49
17:56 ISC Matt Prep lab n More measurements 18:13
18:03 VAC Janos EY, EX n Parts locate 18:33
18:07 FAC Tyler Xarm n Checkng on X1 bte 18:37
20:21 VAC Travis Mids n Measurement and prep for tomorrow 20:50
20:54 ISC Rahul, Jennie Opt Lab YES ISS array work 23:08
H1 ISC (CAL, IOO)
elenna.capote@LIGO.ORG - posted 16:21, Monday 13 October 2025 (87453)
Optical gain before and after power outage

In 86964 I ran a side by side comparison of the powers at various ports before and after the power outage so we could determine what, if anything had changed. Although it generally seemed like we had regained or even increased the powers everywhere, kappa C has indicated that the optical gain reduced. Our current kappa C has been consistently near 0.98 since the outage.

However, I calculated the full optical gain value today from the most recent calibration report (20251012T200500Z) and the current exported report on August 23 (20250823T183838Z). Each report lists H_c in ct/m. I also chose a time just before each report was measured to calculate the OMC-DCPD_SUM/LSC-DARM_IN1 transfer function that provides the mA/ct calibration value.

Date OMC-DCPD_SUM/LSC-DARM_IN1 [mA/ct] H_c [ct/m] Optical gain [mA/pm]
10/12 2505448 3.423e6 8.576
8/23 2465012 3.478e8 8.573

It seems like our optical gain between these two times has actually stayed the same to much less than a percent. I'm not sure what to make of this with regards to the calibration, given that the calibration report suggests an overall magnitude change in the sensing function (that we are correcting in the TDCFs), but in actuality the magnitude of the sensing function has remained constant.

LHO General
ibrahim.abouelfettouh@LIGO.ORG - posted 16:20, Monday 13 October 2025 (87452)
OPS Eve Shift Start

TITLE: 10/13 Eve Shift: 2330-0500 UTC (1630-2200 PST), all times posted in UTC
STATE of H1: Observing at 150Mpc
OUTGOING OPERATOR: TJ
CURRENT ENVIRONMENT:
    SEI_ENV state: CALM
    Wind: 19mph Gusts, 14mph 3min avg
    Primary useism: 0.05 μm/s
    Secondary useism: 0.31 μm/s 
QUICK SUMMARY:

IFO is in NLN and OBSERVING (4 hr lock)

Wind is pickign up. Secondary microseism is picking up. Hoping to stay quiet and locked for the shift.

H1 SUS
oli.patane@LIGO.ORG - posted 16:01, Monday 13 October 2025 (87448)
SatAmp Swap Auto Alog
When we're doing the satamp swaps, we always need to write alog comments for each serial number that was updated. The alogs have repetitive text but have multiple values that need to be changed, and it's time-consuming and easy to miss changing something. I've written a script that automatically grabs the info and copies it to your clipboard so you can paste it into an alog.
The script that I made for auto-generating the satamp swap alog is here as r12693:
/ligo/svncommon/SusSVN/sus/trunk/electronicstesting/lho_electronics_testing/satamp/ECR_E2400330/Scripts/satampalog.py
You can run it by entering the serial number of the satamp and using one of the following flags: --uk4ch, --us4ch, or --us8ch for the satamp type.
 
Example:
$ python3 satampalog_4Jeff.py S1100147 --uk4ch
Alog for S1100147 is copied to clipboard. CRTL+V into alog and 'Preview' or 'Save to Draft' to fix formatting.
 
Pasting into an alog initially, it'll look like this
Click 'Save to Draft' to fix the formatting. It'll then look like this
Images attached to this report
H1 SUS (SEI)
oli.patane@LIGO.ORG - posted 13:22, Monday 13 October 2025 - last comment - 15:54, Monday 13 October 2025(87444)
SR3 P Estimator Blend filter swapped (back)

For the SR3 P estimator, we had initially developed and installed blend filters (in H1:SUS-SR3_M1_EST_P_FUSION_MEAS_BP and H1:SUS-SR3_M1_EST_P_FUSION_MODL_BP filter banks), named pit_v1, that blended between the OSEMs on-resonance, and the estimator everywhere else (86452). After a bit, Brian Lantz made a pit_v2 that included OSEM damping at two extra frequencies because we were having issues with extra resonances at 0.65 and 0.75 Hz that weren't being damped (86510)(filter comparisons).
Eventually we realized the reason why those two peaks weren't being damped was because we had forgotten to include the model contribution to P from L, and we installed those needed filters(86567). However, we didn't swap the blend filters back to pit_v1 at the time.
So during relocking today (2025/10/13 19:05:00 UTC), I swapped us back to pit_v1. We will run with this until at least tomorrow morning and then verify that we don't see a difference in the damping of those two peaks.

Images attached to this report
Comments related to this report
brian.lantz@LIGO.ORG - 13:44, Monday 13 October 2025 (87445)

Oli - Thanks for doing this test, I'm looking forward to learning what happens. I think the question here is "how well does it work" and "what do we see" rather than "does it work". I'm hoping this will reduce the RMS a bit, although the analysis is complicated by the cross-coupling w/ length.

H1 General
thomas.shaffer@LIGO.ORG - posted 11:08, Monday 13 October 2025 - last comment - 12:23, Monday 13 October 2025(87441)
Lock loss 1747 UTC

Lock loss 1444412849

While it was during commissioning, it seems like it wasn't any of the activities going on at the time. Looks very much like the most recent lock losses we have that very quickly go.

Comments related to this report
thomas.shaffer@LIGO.ORG - 12:23, Monday 13 October 2025 (87443)

Back to observing at 1917 UTC. Ran initial alignment, but I didn't have to do anything.

H1 ISC
elenna.capote@LIGO.ORG - posted 10:41, Monday 13 October 2025 (87439)
Changing OFI temperature test

Jennie W, Elenna

Today we changed the OFI temperature and monitored the OFI PD A power. At each temperature change, we reran Sheila's OMC fringe wrapping injection to replicate the measurement Sheila and Naoki did in alog 78942.

Results: we did not see a very significant change in the OFI PD A power when we changed the OFI temperature from 37.5 C to 25.5 C. We see a smaller scattering shelf at 25.5 C than we do at 37.5 C.

I saved Sheila's template over into my own directory as /ligo/home/elenna.capote/OFI/OMC_fringe_wrapping.xml

She had old references in that template (different from the alog) that were taken in Sept 2024. Those references indicated that an OFI temperature of 37.5 C had the smallest scattering shelf. Today, Jennie and I saw very little difference between the scattering shelves generated at 37.5 C (nominal temperature), 34.5 C and 30.5 C. Only when we measured at 25.5 C did we see the scatter shelf reduce slightly (plot).

In this plot, I added in Sheila's old references that show the exact opposite result a year ago. Specifically, the 25.5 C measurement from now is very close to the old 37.5 C measurement from a year ago.

At first, I didn't think there was much of a change in the power on OFI PD A. However, looking at the second trend, it looks like maybe the power dropped by a small amount. I might have needed to slow down this test more than I realized (plot). I saved this ndscope template in /ligo/home/elenna.capote/OFI/OFI_TEC.yaml

 

Images attached to this report
LHO VE
david.barker@LIGO.ORG - posted 10:34, Monday 13 October 2025 (87440)
Mon CP1 Fill

Mon Oct 13 10:07:35 2025 INFO: Fill completed in 7min 32secs

 

Images attached to this report
H1 PSL
ryan.short@LIGO.ORG - posted 10:02, Monday 13 October 2025 (87438)
PSL 10-Day Trends

FAMIS 31107

The main changes that can be seen this week are a result of our amplifier pump diode current adjustments on Tuesday (alog87338). Otherwise, no major events this week.

Images attached to this report
LHO General
thomas.shaffer@LIGO.ORG - posted 07:38, Monday 13 October 2025 (87435)
Ops Day Shift Start

TITLE: 10/13 Day Shift: 1430-2330 UTC (0730-1630 PST), all times posted in UTC
STATE of H1: Observing at 153Mpc
OUTGOING OPERATOR: Ryan S
CURRENT ENVIRONMENT:
    SEI_ENV state: CALM
    Wind: 17mph Gusts, 12mph 3min avg
    Primary useism: 0.04 μm/s
    Secondary useism: 0.22 μm/s 
QUICK SUMMARY: Locked for 21.5 hours. No alarms, two GRB shorts overnight.

LHO General
ibrahim.abouelfettouh@LIGO.ORG - posted 22:00, Sunday 12 October 2025 (87434)
OPS Eve Shift Summary

TITLE: 10/13 Eve Shift: 2330-0500 UTC (1630-2200 PST), all times posted in UTC
STATE of H1: Observing at 151Mpc
INCOMING OPERATOR: Ryan S
SHIFT SUMMARY:

IFO is in NLN and OBSERVING (12 hr lock)

We were locked for the entirety of shift.

The range came back over the course of the shiftso did not have to leave OBSERVING to touch up the squeezer.

Wind and ground motion look good

LOG:

 

LHO General
thomas.shaffer@LIGO.ORG - posted 16:30, Sunday 12 October 2025 (87427)
Ops Day Shift End

TITLE: 10/12 Day Shift: 1430-2330 UTC (0730-1630 PST), all times posted in UTC
STATE of H1: Observing at 147Mpc
INCOMING OPERATOR: Ibrahim
SHIFT SUMMARY: One lock loss that only needed initial alignment but full auto. After we thermalized I ran a calibration sweep in coordination with LLO. The range for this most recent lock looks to be trending down slightly. The SQZ blrms see it, but Ibrahim will keep an eye on things.
LOG:

H1 ISC
elenna.capote@LIGO.ORG - posted 11:58, Thursday 02 October 2025 - last comment - 11:57, Monday 13 October 2025(87260)
Camera spot calibration

Today I began calibrating the camera servo signals into spot positions. I ran the A2L script at the nominal camera spot positions. Then, I changed the camera offset and waited for the camera servo to converge. Then I remeasured the A2L gain. Using the a2l_lookup function in /opt/rtcds/userapps/release/isc/common/scripts/decoup/BeamPosition the A2L gain can be converted into a spot position in mm. This is a slow process so it will take time to get the conversions for all.

  Camera offset A2L gain Conversion
ETMY Pitch start: -230, end: -231 start: 5.62, end: 5.92

(-23.2 mm - -21.8 mm)/-1ct 

= 1.4 mm/ct

ITMX Pitch start: -230, end: -231 start: -0.45, end: -0.56

(6.46 mm - 5.96 mm)/-1ct  

= -0.5 mm/ct

 

Comments related to this report
elenna.capote@LIGO.ORG - 10:23, Monday 06 October 2025 (87313)

I continued today following the same process stated above.

  Camera offset A2L gain Conversion
ETMX P start: -173, end: -172 start: 3.04, end: 2.92

(-9.38 mm - -9.93 mm)/ 1ct 

= 0.55 mm/ct

ETMY Y start: -349.5, end: -348.5 start: 1.41, end: 1.06

(3.90 mm - 5.18 mm) / 1ct 

= -1.28 mm/ct

ETMX Y start: -422, end: -421 start: 4.85, end: 4.68

(17.22 mm - 17.84 mm)

= -0.62 mm/ct

elenna.capote@LIGO.ORG - 11:57, Monday 13 October 2025 (87442)

I reran the ITMX beam spot calibration following the same method described above, but this time I checked how the beam spot moved on both ITMX and ITMY when I changed the BS camera offset. Turns out, they give the same answer, so that's good.

  Camera Offset A2L gain Conversion
ITMX P (ITMY P) start: -230 ct, end: -231 ct start: -0.45 (0.19), end: -0.55 (0.09)

(6.41 mm - 5.96 mm)/-1 ct

= -0.45 mm/ct

ITMX Y (ITMY Y) start: -236 ct, end: -237 ct start: 3.18 (-2.75), end: 3.06 (-2.63)

(11.26 mm - 11.70 mm)/ -1ct

= 0.44 mm/ct (-0.44 mm/ct for ITMY)

 

H1 SUS (ISC)
jeffrey.kissel@LIGO.ORG - posted 16:20, Tuesday 08 July 2025 - last comment - 14:30, Monday 13 October 2025(85639)
H1SUSITMY L2DAMP P and R Open Loop Gain TFs
E. Capote, J. Kissel, S.Dwyer

The ~1 Hz ring-up that had been marginally stable and transient is now fully unstable during the lock acquisition sequence as we recover from maintenance. The suspicion is that the change in ITM M0/R0 satamps might have changed the top mass damping loop OLGTF enough to augment the damped plant that's the plant for the never-really-well-designed L2DAMP that takes the L2 (or PUM) OSEMs and feeds back their sensor signal to the reaction chain top mass OSEMs actuators. But also, we've never measured these loops in any substantial form, so we wanted to just see what they were doing.

Attached are the results. Here're the templates:
    /ligo/svncommon/SusSVN/sus/trunk/QUAD/H1/ITMY/SAGR0/Data/
        2025-07-08_2240UTC_H1SUSITMY_R0_WhiteNoise_0p02to50Hz_L2DAMP_OLGTF_P.xml
        2025-07-08_2240UTC_H1SUSITMY_R0_WhiteNoise_0p02to50Hz_L2DAMP_OLGTF_R.xml

Very little loop gain and only at 3.3 Hz. The loop stability is questionable at that frequency -- for a few averages the suppression (i.e. the gain peaking) looks really sharp around 3.3 Hz. 
T'was really tough to get good coherence; the excitation is pretty well tailored, but it's tough to fight the 1/f^6 suppression of the physical suspension and dirt coupling.
I had to turn OFF the R0 alignment offsets to get this data for pitch. (They were ON for the Roll measurement).

So -- perhaps not the source of the ~1 Hz IFO instability, but boy could this loop use some TLC in order to more effectively achieve its goals...
Images attached to this report
Comments related to this report
jeffrey.kissel@LIGO.ORG - 14:30, Monday 13 October 2025 (87447)
FYI, we also took ITMX data for these loops as well.
    /ligo/svncommon/SusSVN/sus/trunk/QUAD/H1/ITMX/SAGR0/Data
        2025-07-08_2240UTC_H1SUSITMX_R0_WhiteNoise_0p02to50Hz_L2DAMP_OLGTF_P.xml
        2025-07-08_2240UTC_H1SUSITMX_R0_WhiteNoise_0p02to50Hz_L2DAMP_OLGTF_R.xml
Images attached to this comment
Displaying reports 4201-4220 of 89162.Go to page Start 207 208 209 210 211 212 213 214 215 End