david.barker@LIGO.ORG - posted 10:38, Wednesday 24 September 2025 (87117)
Wed CP1 Fill

Wed Sep 24 10:08:21 2025 INFO: Fill completed in 8min 18secs

Gerardo confirmed a good fill curbside.

Images attached to this report
LHO General
ryan.short@LIGO.ORG - posted 07:39, Wednesday 24 September 2025 - last comment - 11:28, Wednesday 24 September 2025(87116)
Ops Day Shift Start

TITLE: 09/24 Day Shift: 1430-2330 UTC (0730-1630 PST), all times posted in UTC
STATE of H1: Observing at 153Mpc
OUTGOING OPERATOR: Tony
CURRENT ENVIRONMENT:
    SEI_ENV state: CALM
    Wind: 2mph Gusts, 0mph 3min avg
    Primary useism: 0.01 μm/s
    Secondary useism: 0.14 μm/s 
QUICK SUMMARY: H1 has been locked for 3.5 hours. One lockloss overnight with an unknown cause, but relocking seems to have gone without issue. We will have a short planned commissioning window from 16:00 to 17:00 UTC.

Comments related to this report
ryan.short@LIGO.ORG - 11:28, Wednesday 24 September 2025 (87122)

The hour of commissioning time did not happen today due to calibration report issues at LLO. This has been added onto tomorrow's regularly scheduled commissioning time, so we will have a total of 4.5 hours (with the first 30 minutes dedicated to calibration sweeps, as usual).

LHO General
ibrahim.abouelfettouh@LIGO.ORG - posted 22:00, Tuesday 23 September 2025 (87115)
OPS Eve Shift Summary

TITLE: 09/24 Eve Shift: 2330-0500 UTC (1630-2200 PST), all times posted in UTC
STATE of H1: Observing at 150Mpc
INCOMING OPERATOR: Tony
SHIFT SUMMARY:

IFO is in NLN and OBSERVING as of 22:59 UTC (6 hr lock)

We've been locked for the entirety of shift.

LOG:

None

H1 SUS (SEI)
oli.patane@LIGO.ORG - posted 18:23, Tuesday 23 September 2025 (87112)
H1SUSSRM OSEM Absolute Calibration Measurements

As the other half of Jeff's Side Quest 4 (87102), I took measurements for calculating the absolute calibration of SRM.

Doing this will make the estimator work for SRM easier later on. Like Jeff, I also took two sets of measurements, one with the offsets on (ALIGNED), and one with the offsets off (HEALTH_CHECK). The official measurements that we will be using for getting the OSEM absolute calibration are the ones where the optic is ALIGNED, since that's where it usually is. The set of measurements taken with the alignmet offsets off is to see how much of a difference we see between the two states.
The drive in ISO_{X,Y,Z} correlate with the same optic motion directions as they did when I was taking these same measurements for SR3: ISO_X -> SUS_DAMP_T, ISO_Y -> SUS_DAMP_L, ISO_Z -> SUS_DAMP_V.

These were the settings for the measurements:
- HAM5 in ISI_DAMPED_HEPI_OFFLINE
- SRM in ALIGNED or SRM in HEALTH_CHECK (with damping on)

SRM in ALIGNED (official measurements)
Found in /ligo/svncommon/SusSVN/sus/trunk/HSTS/H1/SRM/Common/Data/
2025-09-23-1830_H1ISIHAM5_ST1_SRM_ALIGNED_WhiteNoise_ISO_X_0p05to40Hz_calibration.xml r12666
2025-09-23-1830_H1ISIHAM5_ST1_SRM_ALIGNED_WhiteNoise_ISO_Y_0p05to40Hz_calibration.xml r12666
2025-09-23-1830_H1ISIHAM5_ST1_SRM_ALIGNED_WhiteNoise_ISO_Z_0p05to40Hz_calibration.xml r12666

In ALIGNED, here are the suspension positions according to the OSEMs (in urads*, see Jeff's explanation):
    M1 OPTICALIGN sliders   M1 OSEM    M2 OSEM    M3 OSEM
P          +2520             +1071       +790       +837
Y          -3809              +40        -479       -397

The alignment slider calibrations for SRM are P = 1.875 [DAC ct/"urad"] and Y = 2.681 [DAC ct/"urad"]

SRM in HEALTH_CHECK with damping on (extra measurements for looking at difference)
Found in /ligo/svncommon/SusSVN/sus/trunk/HSTS/H1/SRM/Common/Data/
2025-09-23-1810_H1ISIHAM5_ST1_SRM_NoOffsets_WhiteNoise_ISO_X_0p05to40Hz_calibration.xml r12666
2025-09-23-1810_H1ISIHAM5_ST1_SRM_NoOffsets_WhiteNoise_ISO_Y_0p05to40Hz_calibration.xml r12666
2025-09-23-1810_H1ISIHAM5_ST1_SRM_NoOffsets_WhiteNoise_ISO_Z_0p05to40Hz_calibration.xml r12666

Comparing the two sets of measurements, you can see that between both L's and both V's, the M1 OSEMs for the ALIGNED cases are closer to each other than the Offsets Off case, but they still need a calibration factor.

Images attached to this report
H1 ISC
elenna.capote@LIGO.ORG - posted 18:17, Tuesday 23 September 2025 - last comment - 16:36, Wednesday 24 September 2025(87114)
Modulation Depth test results - March vs September

Back in March, I ran a modulation depth test, with several goals in mind related to providing useful calibration information for modeling. That alog is still unfortunately sitting in my drafts. However, I was able to use the results to make a side-by-side comparison with a modulation depth test Sheila ran last Thursday, after the power outage. We are still trying to understand what the overall effect of the power outage was on the IFO. Namely, we have lost 1% of optical gain, 86964.

Some background: the modulation depth test aims to measure the fraction of carrier, 9 MHz and 45 MHz power at each port. This is done by measuring the powers at the nominal settings, and then individiually stepping the 9 and 45 MHz modulation up or down by a known value. Using a measured calibration of V/dBm and rad/V (see alog 62883), and using the bessel functions, the power fraction of each field can be measured at each diode based on how much the total diode power changes at each step. (note: I still have a to do list item to better calibrate the modulation depth in radians using OMC scan data).

Procedure: I stepped both down and up in modulation depth, resulting in 5 different measurements (nominal, 9 down, 9 up, 45 down, 45 up). In March, I stepped down by 3 dBm and up by 2 dBm, but in September we were able to step both down and up by 3 dBm. I measured for 3 minutes at each step in March, and 1 minute at each step in September.

EDIT: I realized I made an error, and the first results I report below are actually from Feb 2025. The significant difference here is that in my February measurement I only stepped down by 3 dBm for 9 and 45 MHz each, so there is less data to fit. In my March measurement, I stepped up 2 dBm and down 3 dBm, getting 5 total different measurement times. There should be very little difference in the interferometer between February and March 2025, so the differences in the results I believe are due to the fact that more points (5 versus 3) gives you a much better fit to the data. I would compare March and now for a more accurate understanding of the differences.

February results, well before power outage, only fit from 3 data points:

Field Input POP REFL AS
carrier 0.9771 0.9842 0.9419 0.3386
9 MHz 0.01278 0.01527 0.02950 0.1787
45 MHz 0.01003 0.000474 0.02860 0.4827

March results, before power outage, fit from 5 data points:

Field Input POP REFL AS
carrier 0.9779 0.9831 0.9164 0.2134
9 MHz 0.01212 0.01332 0.04059 0.2761
45 MHz 0.009687 0.002302 0.04431 0.5413

September results, after power outage (and reduction of PSL power, attenuation at IMC REFL), fit from 5 data points:

Field Input POP REFL AS
carrier 0.9783 0.9833 0.9333 0.3556
9 MHz 0.01195 0.01325 0.02533 0.1852
45 MHz 0.009486 0.001909 0.04199 0.4641

EDIT: Including the March results (and trusting them more than the February results) changes the conclusion. The input ratios are very similar between all three measurements. This is also true for POP where carrier and 9 ratios are concerned. 45 MHz is the hardest field to measure because the 9 and carrier are so strong at POP. There may be less 45 MHz at POP, or this is just the measurement uncertainty. At REFL, there may be an increase in carrier light now after the power outage, and there may be half as much 9 MHz as in March.

The most dramatic differences are at the AS port. Just comparing the February and March measurements, there may be considerable uncertainty in how much of each field is at AS in general. However, if we choose to believe the March results, this would suggest a significant increase in carrier at AS, and a significant decrease in 9 and 45 MHz. However, comparing February and now, the 9 MHz and carrier are nearly the same, and the 45 seems to have decreased.

Comments related to this report
elenna.capote@LIGO.ORG - 11:30, Wednesday 24 September 2025 (87123)

Rereading this alog, I see that I should say specifically which diodes measure these powers:

Input == IM4 trans

POP == POP A LF

REFL == REFL A LF

AS = AS_C DC NSUM

elenna.capote@LIGO.ORG - 16:36, Wednesday 24 September 2025 (87131)

Here are plots of various channels during the March and September mod depth tests. The shaded region indicates which step was being taken at the time, and the dotted line matching each shading color indicates the median of the channel at that time.

Non-image files attached to this comment
H1 General (CDS)
filiberto.clara@LIGO.ORG - posted 17:14, Tuesday 23 September 2025 (87113)
HAM5 Cable Tray and MER VDD Rack Work

S&K Electric onsite. Floor cable tray between SUS racks R4 and R7 installed. Isolated cable tray from supports with teflon. Insulated ground bar installed and tied to rack SUS-R7.

Work in the mechanical room mezzanine (power suppy and cabling for SUS-M2) caused h1sush7 IO chassis to glitch. See alog 87095 for details.

D. Barker, F. Clara, and S&K Electric

H1 PSL (IOO)
jennifer.wright@LIGO.ORG - posted 17:08, Tuesday 23 September 2025 (86378)
Data from ISS 18th Aug 2025

Jennie W, Rahul K, Keita K

Executive Summary: The measurements of ISS input beam dither coupling to the PDs need repeated as their may be some settings on the oscilloscope we didn't setup properly.


Measurement Theory:

To get a coupling measurement of the ISS diode array to input beam motion we need:

AC measurement for each of the 8 diodes (ACPD1, ACPD2, etc.).

simultaneous AC measurement for the X and Y channels of the QPD (X, Y).

We have a calibration measured previously that tells us that the QPD calibration [Cal] is 45 V/mm when the input beam is dithered horizontally, and that the direction we dither the beam in is 14.9 degrees from the X axis of the QPD (presumably because the QPD is not quite aligned rotationally in its support).

To work out the movement in the actual horizontal plane on the QPD (R_QPD) we use:

Mag = sqrt(X^2 + Y^2)

theta = atan2(Y, X)

R_QPD = Mag * e^(i*theta)

Average DC voltage for each of the 8 PDs to normalise the coupling measurement (DC1, DC2, etc)

Coupling = (AC PDn / DCn)/ (R_QPD/Cal)


When Mayank and Shiva were here we were doing this measurement using the average and peak to peak values for the voltages of DC and AC signals respectively. This throws away the phase info, so now we are trying to do this using transfer functions between the motion of the input beam on the QPD and the PDs.


On August 18th we re-aligned the input to the ISS in the optics lab to minimise the coupling to each of the PDs by eye on the oscilloscope traces showing the AC coupled time series.

The dither used to measure the coupling is applied on a steering mirror after the mode-matching lens but before the PBS used to fix the polarisation of the beam.

The dither we used initially was 1Vpp, but we made some effort to reduce noise on the signal by tuning the resistance of the laser temperature controller.

The new dither is 40mVpp at 100 Hz, and has an offset of 2.5V to keep the mirror aligned into the ISS array input aperture.


All three oscilloscopes are synced via a square wave from the signal generator used for the dither and can be controlled by USB hookups to the opticslab PC.

The code to trigger them at once is from the ipython notebook saved on C:\Users\opticslab as meas_TF_osc.ipynb:

# %%
import pyvisa
rm = pyvisa.ResourceManager()
import numpy as np
import time
print(rm.list_resources())     ## This command list the available resources
# %%
delay = 4  # Allow a delay in query between write and read
scope1 = rm.open_resource('USB::0x0699::0x03A3::C060047::INSTR', query_delay=delay)      ## Instantiates the instrument
scope2 = rm.open_resource('USB::0x0699::0x03A3::C042270::INSTR', query_delay=delay)      ## Instantiates the instrument
scope3 = rm.open_resource('USB::0x0699::0x03A3::C042275::INSTR', query_delay=delay)      ## Instantiates the instrument
# %%
scope1.write(f'ACQUIRE:STATE OFF')
scope2.write(f'ACQUIRE:STATE OFF')
scope3.write(f'ACQUIRE:STATE OFF')
# %%
scope1.write(f'ACQUIRE:MODE SAMPLE')
scope2.write(f'ACQUIRE:MODE SAMPLE')
scope3.write(f'ACQUIRE:MODE SAMPLE')

scope1.write(f'ACQUIRE:STOPAFTER SEQUENCE')
scope2.write(f'ACQUIRE:STOPAFTER SEQUENCE')
scope3.write(f'ACQUIRE:STOPAFTER SEQUENCE')
#%% Acquire waveform data
scope1.write(f'ACQUIRE:STATE ON')
scope2.write(f'ACQUIRE:STATE ON')
scope3.write(f'ACQUIRE:STATE ON')

All this does is trigger the scopes, the channels have to be turned on manually and saved manually. Francisco has worked on a much better bersion of this code but I haven't had time to test it yet.

 


The data we gathered on the 18th is shown below.

The time series for X and Y is shown here.

The time series for ACPD1-8 is shown here.

One can not really see a coherence, this could mean the array is perfectly aligned, but this is not likely as we have not done very fine adjustments.

This is more obvious if one looks at the ASD of each of the PDs, I have just attached one of these but none of them show a signal above the surrounding noise at 100 Hz where the injection was.

We are seeing this signal on the X and Y ASDs.

The csv files I saved for AC, DC and QPD all had different time steps, but the same span meaning they were all different lengths. We might need to retake this data and mess around with the display and save settings to fix this - Keita investigated earlier today and it is possible to change the save resolution to be larger and also to reduce the number of samples the oscilloscope saves via the trigger menu.

I might also try to increase the dither amplitude if this still doesn't help us do the measurement.


Once we have this measurement working we will need to iterate this measurement a few times while making small adjustments to the alignment into the array and possibly moving one or more of the PDs in their mounts.

The next steps are to repeat this measurement for vertical dither and then to do beam scans across each PD to see how well centred they are with respect to the beam.

Images attached to this report
LHO General
ryan.short@LIGO.ORG - posted 16:30, Tuesday 23 September 2025 (87100)
Ops Day Shift Summary

TITLE: 09/23 Day Shift: 1430-2330 UTC (0730-1630 PST), all times posted in UTC
STATE of H1: Observing at 152Mpc
INCOMING OPERATOR: Ibrahim
SHIFT SUMMARY: Busy maintenance day that we've just recovered from. Maintenance activities ran slightly long, and relocking took longer than expected due to a lockloss during INJECT_SQUEEZING from an unknown source. The AIP is still running at HAM6. H1 has been locked for about 30 minutes.
LOG:

Start Time System Name Location Lazer_Haz Task Time End
15:03 FAC Kim, Nellie LVEA N Technical cleaning 16:19
15:03 VAC Gerardo, Jordan LVEA n HAM5/6 AIP work 16:47
15:03 FAC Ken LVEA N Cable trays HAM5/6 18:24
15:07 PEM Sam LVEA n Accelerometers on BSCs7/8 15:40
15:13 CAL Tony, Dripta PCal Lab Local Setting up for measurement 18:07
15:16 CDS/SUS Fil EY n Replacing EY UIM sat amp 16:01
15:17 PSL Keita, Ryan S PSL enc Local PSL beam profiles and inspections 17:35
15:19 VAC Norco MX n LN2 fill 17:52
15:25 PCAL Tony, Dripta EY YES PCAL meas 17:53
15:28 FAC Chris outbuildings n FAMIS checks 16:53
15:34 FAC Christina OBS rec. n Forklifting crates to OSB receiving 16:07
15:42 VAC Anna LVEA n Joining the other vac'rs at HAM5/6 16:31
16:01 VAC Travis MY n More pump work 19:01
16:02 CDS/SUS Fil LVEA n More sat amp swapping for ITMs UIM, BS M2, PRM M2 M3, SRM M2 M3 17:25
16:22 FAC Kim EY n Tech clean 17:46
16:36 FAC Nelly EX n Tech clean 17:20
16:37   TJ LVEA n Giving Keita a camera battery 16:40
16:48 VAC Pump LVEA HAM5/6 n AIP pumping Ongoing
16:54 SYS Betsy LVEA n Putting parts away 17:24
17:10 FAC Nelly EX n Tech clean 17:11
17:10 FAC Nelly FCES n Tech clean 17:45
17:18 VAC Gerardo, Jordan LVEA n Getting parts in the W bay 18:20
17:30 CDS Fil Mech Mezz n BHD electronics power supplies on mech room mezz 19:06
17:32 VAC Norco EX n LN2 fill (start time unknown) 18:26
17:38 SUS/SEI Jeff, Oli CR n Drive HAM2/5 ISI 18:23
17:49 ISC Camilla, Elenna LVEA LOCAL IOT2 table beam profiling 19:05
17:51 SEI Jim LVEA n Placing L4Cs under HAM6 19:00
18:14 SYS Betsy LVEA n Parts 18:19
18:18 - Ibrahim, guest LVEA n Tour 18:48
18:31 ISC Daniel LVEA N Cable length measurements 19:06
18:37 FAC Ken Opt Lab N Lights 19:37
18:49   Ibrahim, guest Overpass N Tour 19:49
18:49 VAC Jordan LVEA N Looking at pump 18:54
18:52 OPS TJ LVEA N Sweep 19:07
20:24 VAC Travis MX, MY N Measuring parts 20:50
22:30 VAC Jordan, Pfeiffer reps MY N Tour for reps 00:30
LHO General
ibrahim.abouelfettouh@LIGO.ORG - posted 16:09, Tuesday 23 September 2025 (87111)
OPS Eve Shift Start

TITLE: 09/23 Eve Shift: 2330-0500 UTC (1630-2200 PST), all times posted in UTC
STATE of H1: Preventive Maintenance
OUTGOING OPERATOR: Ryan S
CURRENT ENVIRONMENT:
    SEI_ENV state: CALM
    Wind: 11mph Gusts, 4mph 3min avg
    Primary useism: 0.02 μm/s
    Secondary useism: 0.14 μm/s 
QUICK SUMMARY:

IFO is NLN and OBSERVING as of 22:56 UTC

Maintenance went slightly long after IOT2L Beam Profiling, requiring us to pico to get bacvk onto IMC WFs.

Additionally, there were SQZ issues relating to the filter cavity not being able to lock potentially due to reset HAM7 FC1 slider values.

Note: Annulus pump running near HAM6 (alog 87101).

Hoping to stay in Observing!

H1 SUS
oli.patane@LIGO.ORG - posted 15:41, Tuesday 23 September 2025 (87105)
OSEMINF compensation filters updated to match with satamp swap: ITMX (L1), ITMY (L1), BS (M2), PRM (M2, M3), SRM (M2, M3)

Fil swapped out the satamps for ETMY (L1), ITMX (L1), ITMY (L1), BS (M2), PRM (M2, M3), SRM (M2, M3) today (87103), so the 10:0.4 filters compensation filter in the OSEMINF bank for these SUS's named stages needed to be updated to their new precise compensation filters. Jeff measured the response for each satamp's channels before they were installed, and I used my script python3 /ligo/svncommon/SusSVN/sus/trunk/Common/PythonTools/satampswap_bestpossible_filterupdate_ECR_E2400330.py -o ITMX_L1 ITMY_L1 BS_M2 PRM_M2_M3 SRM_M2_M3 to mass update these compensation filters. I've attached a txt file of the output of this script, along with the filter diffs for each suspension before I loaded them all in.

PS Jeff had done ETMY L1 by hand earlier, so I didn't need to update it with my script.

Images attached to this report
Non-image files attached to this report
H1 ISC (PSL)
camilla.compton@LIGO.ORG - posted 14:47, Tuesday 23 September 2025 (87109)
Beam Profiles Taken of MC REFL on IOT2L After EOM Power Reduction

Elenna, Camilla, Ryan. WP#12806 . IOT2L layout D1300357

Followup from the beam measurements taken last week 86962, while we still had the nominal ~115W through the PSL EOM. Elenna and I repeated these measurements today, now that the power through the EOM has been reduced to ~90W, see 86966, which appeared to improve the mode matching to the IMC. We see the beam has changed shape (now larger on IOT2L) since the power reduction.  

We took the PSL input power down to ~100mW, locked out the rotation stage and then used the nano scan to take some beam profiles in the IMC REFL path on IOT2L.

Sadly we must have bumped something in the beam path as once we came out the MC REFL WFs were misaligned, mainly in pitch. The power was unchanged on the RFPD so Elenna and Ryan pico-ed each WFS steering mirror to re-center the beams. 
We did knowingly bump the camera labeled IO-MCR-RFPD but confirmed this is unused.
 
Location D4 Sigma A1 Horizontal (um) D4 Sigma A2 Vertical (um) D4 Sigma A1 at 45deg (um) D4 Sigma A2 at 45deg (um)
A: Profiler 11 1/2" upstream of IO_MCR_BS1 4922 4722 4731 4904
B: Profiler 10 7/16" downstream of IO_MCR_BS1 (7" + 1 1/2" + 1 15/16") 4992 4829 4953 4875
C: Profiler 14 5/8" downstream of IO_MCR_BS1 (7" + 1 1/2" + 6 1/8") 5187 4817 5050 4857

For positions B and C, we added a temporary steering mirror between IO_MCR_M7 and IO_MCR_L2. Distance between IO_MCR_BS1 and IO_MCR_M7 = 7"; Distance bewtween IO_MCR_M7 and temporary steering mirror = 1 1/2". 

Images attached to this report
H1 SUS (SEI)
jeffrey.kissel@LIGO.ORG - posted 13:41, Tuesday 23 September 2025 - last comment - 14:03, Tuesday 23 September 2025(87102)
H1SUSPRM Absolute Calibration (via ISIHAM2 GS13s) Measurements Taken (Aligned vs. Misaligned are Quite Different)
J. Kissel

We're beginning the process of completing all the side quests for suspensions beyond SR3 and PR3. For a summary of what these side quests are, check out the first half of G2501621. 
Today, after 
 - LHO:87103 Fil upgraded satamps the lower, M2 and M3, stages of H1 SUS PRM (ECR E2400330; Side Quest 1), and
 - LHO:87105 Oli updated the OSEMINF filter banks to precisely compensate the new sat amp frequency response (Side Quest 3),
I report on measurements taken for Side Quest 4 -- to measure the absolute, overall scale of the individual OSEMs response to suspension point motion (as predicted from the ISI GS13s projected into that basis) in the presence of ISI drive. This will eventually be processed in a way similar to LHO:86222 for PR3 top mass and LHO:84531 for SR3 top mass.

However, for PRM, which is a globally controlled suspension where we drive the M2 and M3 stages (unlike PR3/SR3), the lower stages also need all of these side quests and absolute calibration. So, here I gather the data or the M2 and M3 as well since we can get them "for free," just adding the channels to the response list.

Here's the position of the suspension according to the medium trustworthy "urad" while the suspension is ALIGNED -- 
          M1 Drive request    M1 OSEM      M2 OSEM      M3 OSEM [all "urad"]
    P ::      -1628           -1231          -982         -1520 
    Y ::        -60             -45          +645          -344
where I put "urad" in quotes because that's what these OSEMs are all calibrated to, nominally, but they've never been validated with anything -- until the future results from the data in this aLOG. That includes -- to the best of my aLOG searching, even the alignment sliders (which are sometimes calibrated with using the IFO beam and a distant geometrically known shape as an optical lever; see e.g. for BS and PR2 LHO:25650 or PR3 LHO:70197). Indeed, the alignment slider calibrations for PRM are still P = 1.875 [DAC ct/"urad"] and Y = 2.681 [DAC ct/"urad"] that were derived from the modeled electronics chain and actuation strength from LHO:4563.

Anyways -- Here's the data with the alignment offsets ON.
/ligo/svncommon/SusSVN/sus/trunk/HSTS/H1/PRM/Common/Data
2025-09-23_1810_H1ISIHAM2_ST1_PRM_WhiteNoise_ISO_X_0p05to40Hz_calibration.xml
2025-09-23_1810_H1ISIHAM2_ST1_PRM_WhiteNoise_ISO_Y_0p05to40Hz_calibration.xml
2025-09-23_1810_H1ISIHAM2_ST1_PRM_WhiteNoise_ISO_Z_0p05to40Hz_calibration.xml
and I attach screenshots of these templates' results.

The top mass, M1 data show similar levels of calibration adjustment needed as PR3/SR3; corrections in the range of 1/0.78 = 1.28 [urad/"mrad"] and 1/0.64 = 1.56 [urad/"urad"] are needed.
Perhaps unsurprisingly, the lower stage OSEMs need similar levels of correction. 
PRM's M3 LL OSEM needs the most correction, needing a factor of 1/0.0915 = 10.9 [urad / "urad"]. Yikes! Note, with the suspension ALIGNED, the ADC counts for the M3 LL are still at 18660 [ct], and MISALIGNED they're 18740 [ct], both out of 2^15 = 32768 [ct], so it's not like it's at the edge of it's range, either with the flag fully or not occulting light. Nor is it like the LED emitted power dropped substantially low... huh.

Welp, it'll be good to get all of these OSEMs calibrated!
Images attached to this report
Comments related to this report
jeffrey.kissel@LIGO.ORG - 13:40, Tuesday 23 September 2025 (87106)
Here's a zoom of data in the ALIGNED configuration on the linear scale -- above ~5 Hz, above the resonances, where we expect the calibration to be 1.0 [OSEM m / GS13 m]. 
Images attached to this comment
jeffrey.kissel@LIGO.ORG - 14:03, Tuesday 23 September 2025 (87107)SEI
Also out of mistake and then curiosity, I also gathered data with the *misalignment* offsets ON, i.e. when the suspension is MISALIGNED.
/ligo/svncommon/SusSVN/sus/trunk/HSTS/H1/PRM/Common/Data
2025-09-23_1730_H1ISIHAM2_ST1_PRM_WhiteNoise_ISO_X_0p05to40Hz_calibration.xml
2025-09-23_1730_H1ISIHAM2_ST1_PRM_WhiteNoise_ISO_Y_0p05to40Hz_calibration.xml
2025-09-23_1730_H1ISIHAM2_ST1_PRM_WhiteNoise_ISO_Z_0p05to40Hz_calibration.xml

The reported necessary calibration is markedly different between ALIGNED and MISALIGNED.

This is something we'll *definitely* need to consider for estimators of globally controlled suspensions operationally:
    (1) The calibration of the OSEMs fundamentally changes as the suspension moves across "large" alignment positions.
    (2) That means that we want to make sure we calibrate, and then measure estimator plant transfer functions in the suspensions' nominal low noise alignment position (at least roughly).
    (3) For globally controlled suspensions -- and specifically those that regularly change alignment as a result the IFO's initial alignment procedure -- we need to understand *how* much the calibration is changing even across "small" alignment position changes.
    (4) Also, we'd need to note -- and be able to handle -- a calibration change across how much the alignment position is shifted *during* lock acquisition as the alignment sensing and control's DC request is offloaded to the top mass drive.
    (5) We'll likely need to turn OFF the future estimator, if not at least expect worse performance, when the suspensions are in a "markedly different" alignment position. How "markedly" is "markedly" depends on the answer to (3).

Comforting at least, is that the misalignment offsets are driving the suspensions by *hundreds,* if not a few *thousands* of "urad" from their aligned position. 
Images attached to this comment
H1 SUS
filiberto.clara@LIGO.ORG - posted 13:27, Tuesday 23 September 2025 - last comment - 11:48, Wednesday 24 September 2025(87103)
Sat Amps Modified: PRM, SRM, ITMY, ITMX, BS, and BS

WP 12802
ECR E2400330
Modified List T2500232

The following SUS SAT Amps were upgraded per ECR E2400330. Modification improves the whitening stage to reduce ADC noise from 0.05 to 10 Hz.

Suspension Old New OSEM
PRM M2 S1100080 S1100064 ULLLURLR
PRM M3 S1100106 S1000285 ULLLURLR
SRM M2 S1100078 S1100095 ULLLURLR
SRM M3 S1000274 S1100091 ULLLURLR
ITMY L1 UIM S1100070 S1100129 ULLLURLR
ITMX L1 UIM S1100141 S1000287 ULLLURLR
BS M2 S1000295 S1100117 ULLLURLR
ETMY UIM S1100159 S1100088 ULLLURLR

 

F. Clara, J. Kissel, O. Patane

Comments related to this report
jeffrey.kissel@LIGO.ORG - 10:56, Wednesday 24 September 2025 (87118)ISC
Here's the characterization data and fit results for S1100064, assigned to PRM M2's ULLLURLR OSEMs.

This sat amp is a UK 4CH sat amp, D0900900 / D0901284.

The data was taken per methods described in T080062-v3, using the diagrammatic setup shown on PAGE 1 of the Measurement Diagrams from LHO:86807.

The data was processed and fit using
    ${SusSVN}/trunk/electronicstesting/lho_electronics_testing/satamp/ECR_E2400330/Scripts/
         plotresponse_S1100064_PRM_M2_ULLLURLR_20250917.m

Explicitly, the fit to the whitening stage zero and pole, the transimpedance feedback resistor, and foton design string are
Optic    Stage    Serial_Number    Channel_Number     OSEM_Name    Zero_Pole_Hz    R_TIA_kOhm    Foton_Design
PRM      M2       S1100064         CH1                UL           0.0961:5.24     120.25        zpk([5.24],[0.0961],1,"n")
                                   CH2                LL           0.0950:5.18     120.25        zpk([5.18],[0.0950],1,"n")
                                   CH3                UR           0.0961:5.24     120.25	 zpk([5.24],[0.0961],1,"n")
                                   CH4                LR           0.0962:5.25     120.00	 zpk([5.25],[0.0962],1,"n")
                                   
  
The attached plot and machine readable .txt file version of the above table are also found in
    ${SusSVN}/trunk/electronicstesting/lho_electronics_testing/satamp/ECR_E2400330/Results/

Per usual, R_TIA_kOhm is not used in the compensation filter -- but after ruling out an adjustment in the zero frequency (by zeroing the phase residual at the lowest few frequency points), I nudged the transimpedance a bit to get the magnitude scale within the ~0.25%. shown in the attached results. Any scaling like this will be accounted for instead with the absolute calibration step, i.e. Side Quest 4 from G2501621, a la what was done for PR3 and SR3 top masses in LHO:86222 and LHO:84531 respectively.
Non-image files attached to this comment
jeffrey.kissel@LIGO.ORG - 11:00, Wednesday 24 September 2025 (87119)
Here's the characterization data and fit results for  S1000285 , assigned to PRM M3's ULLLURLR OSEMs.

This sat amp is a UK 4CH sat amp, D0900900 / D0901284.

The data was taken per methods described in T080062-v3, using the diagrammatic setup shown on PAGE 1 of the Measurement Diagrams from LHO:86807.

The data was processed and fit using
    ${SusSVN}/trunk/electronicstesting/lho_electronics_testing/satamp/ECR_E2400330/Scripts/
         plotresponse_S1000285_PRM_M3_ULLLURLR_20250917.m

Explicitly, the fit to the whitening stage zero and pole, the transimpedance feedback resistor, and foton design string are
Optic    Stage    Serial_Number    Channel_Number     OSEM_Name    Zero_Pole_Hz    R_TIA_kOhm    Foton_Design
PRM      M3       S1000285         CH1                UL           0.0956:5.22     120.250       zpk([5.22],[0.0956],1,"n")
                                   CH2                LL           0.0967:5.27     120.250       zpk([5.27],[0.0967],1,"n")
                                   CH3                UR           0.0955:5.21     120.375       zpk([5.21],[0.0955],1,"n")
                                   CH4                LR           0.0950:5.18     120.375       zpk([5.18],[0.0950],1,"n")
                                   
  
The attached plot and machine readable .txt file version of the above table are also found in
    ${SusSVN}/trunk/electronicstesting/lho_electronics_testing/satamp/ECR_E2400330/Results/

Per usual, R_TIA_kOhm is not used in the compensation filter -- but after ruling out an adjustment in the zero frequency (by zeroing the phase residual at the lowest few frequency points), I nudged the transimpedance a bit to get the magnitude scale within the ~0.25%. shown in the attached results. Any scaling like this will be accounted for instead with the absolute calibration step, i.e. Side Quest 4 from G2501621, a la what was done for PR3 and SR3 top masses in LHO:86222 and LHO:84531 respectively.
Non-image files attached to this comment
jeffrey.kissel@LIGO.ORG - 11:03, Wednesday 24 September 2025 (87120)
Here's the characterization data and fit results for  S1100095 , assigned to SRM M2's ULLLURLR OSEMs.

This sat amp is a UK 4CH sat amp, D0900900 / D0901284.

The data was taken per methods described in T080062-v3, using the diagrammatic setup shown on PAGE 1 of the Measurement Diagrams from LHO:86807.

The data was processed and fit using
    ${SusSVN}/trunk/electronicstesting/lho_electronics_testing/satamp/ECR_E2400330/Scripts/
         plotresponse_S1100095_SRM_M2_ULLLURLR_20250917.m

Explicitly, the fit to the whitening stage zero and pole, the transimpedance feedback resistor, and foton design string are
Optic    Stage    Serial_Number    Channel_Number     OSEM_Name    Zero_Pole_Hz    R_TIA_kOhm    Foton_Design
SRM      M2       S1100095         CH1                UL           0.0955:5.22     120           zpk([5.22],[0.0955],1,"n")
                                   CH2                LL           0.0975:5.33     120           zpk([5.33],[0.0975],1,"n")
                                   CH3                UR           0.0951:5.19     120.25        zpk([5.19],[0.0951],1,"n")
                                   CH4                LR           0.0955:5.20     120.25        zpk([5.20],[0.0955],1,"n")
                                   
  
The attached plot and machine readable .txt file version of the above table are also found in
    ${SusSVN}/trunk/electronicstesting/lho_electronics_testing/satamp/ECR_E2400330/Results/

Per usual, R_TIA_kOhm is not used in the compensation filter -- but after ruling out an adjustment in the zero frequency (by zeroing the phase residual at the lowest few frequency points), I nudged the transimpedance a bit to get the magnitude scale within the ~0.25%. shown in the attached results. Any scaling like this will be accounted for instead with the absolute calibration step, i.e. Side Quest 4 from G2501621, a la what was done for PR3 and SR3 top masses in LHO:86222 and LHO:84531 respectively.
Non-image files attached to this comment
jeffrey.kissel@LIGO.ORG - 11:08, Wednesday 24 September 2025 (87121)
Here's the characterization data and fit results for  S1100091 , assigned to SRM M3's ULLLURLR OSEMs.

This sat amp is a UK 4CH sat amp, D0900900 / D0901284.

The data was taken per methods described in T080062-v3, using the diagrammatic setup shown on PAGE 1 of the Measurement Diagrams from LHO:86807.

The data was processed and fit using
    ${SusSVN}/trunk/electronicstesting/lho_electronics_testing/satamp/ECR_E2400330/Scripts/
         plotresponse_S1100091_SRM_M3_ULLLURLR_20250917.m

Explicitly, the fit to the whitening stage zero and pole, the transimpedance feedback resistor, and foton design string are
Optic    Stage    Serial_Number    Channel_Number     OSEM_Name    Zero_Pole_Hz    R_TIA_kOhm    Foton_Design
SRM      M3       S1100091         CH1                UL           0.0983:5.37     120.25        zpk([5.37],[0.0983],1,"n")
                                   CH2                LL           0.0959:5.23     120.25        zpk([5.23],[0.0959],1,"n")
                                   CH3                UR           0.0955:5.23     120.00        zpk([5.23],[0.0955],1,"n")
                                   CH4                LR           0.0957:5.24     120.00        zpk([5.24],[0.0957],1,"n")
                                   
  
The attached plot and machine readable .txt file version of the above table are also found in
    ${SusSVN}/trunk/electronicstesting/lho_electronics_testing/satamp/ECR_E2400330/Results/

Per usual, R_TIA_kOhm is not used in the compensation filter -- but after ruling out an adjustment in the zero frequency (by zeroing the phase residual at the lowest few frequency points), I nudged the transimpedance a bit to get the magnitude scale within the ~0.25%. shown in the attached results. Any scaling like this will be accounted for instead with the absolute calibration step, i.e. Side Quest 4 from G2501621, a la what was done for PR3 and SR3 top masses in LHO:86222 and LHO:84531 respectively.
Non-image files attached to this comment
jeffrey.kissel@LIGO.ORG - 11:35, Wednesday 24 September 2025 (87124)
Here's the characterization data and fit results for  S1100129 , assigned to ITMY L1 (UIM) ULLLURLR OSEMs.

This sat amp is a UK 4CH sat amp, D0900900 / D0901284.

The data was taken per methods described in T080062-v3, using the diagrammatic setup shown on PAGE 1 of the Measurement Diagrams from LHO:86807.

The data was processed and fit using
    ${SusSVN}/trunk/electronicstesting/lho_electronics_testing/satamp/ECR_E2400330/Scripts/
         plotresponse_S1100129_ITMY_L1_ULLLURLR_20250916.m

Explicitly, the fit to the whitening stage zero and pole, the transimpedance feedback resistor, and foton design string are
Optic    Stage    Serial_Number    Channel_Number     OSEM_Name    Zero_Pole_Hz    R_TIA_kOhm    Foton_Design
ITMY     L1       S1100129         CH1                UL           0.0956:5.23     121.75        zpk([5.23],[0.0956],1,"n")
                                   CH2                LL           0.0966:5.28     120.00        zpk([5.28],[0.0966],1,"n")
                                   CH3                UR           0.0978:5.34     120.00        zpk([5.34],[0.0978],1,"n")
                                   CH4                LR           0.0966:5.27     120.00        zpk([5.27],[0.0966],1,"n")
                                   
  
The attached plot and machine readable .txt file version of the above table are also found in
    ${SusSVN}/trunk/electronicstesting/lho_electronics_testing/satamp/ECR_E2400330/Results/

Per usual, R_TIA_kOhm is not used in the compensation filter -- but after ruling out an adjustment in the zero frequency (by zeroing the phase residual at the lowest few frequency points), I nudged the transimpedance a bit to get the magnitude scale within the ~0.25%. shown in the attached results. Any scaling like this will be accounted for instead with the absolute calibration step, i.e. Side Quest 4 from G2501621, a la what was done for PR3 and SR3 top masses in LHO:86222 and LHO:84531 respectively.
Non-image files attached to this comment
jeffrey.kissel@LIGO.ORG - 11:41, Wednesday 24 September 2025 (87125)
Here's the characterization data and fit results for  S1100287 , assigned to ITMX L1 (UIM) ULLLURLR OSEMs.
	(Note the typo in Fil's main entry -- he quotes S1000287, but it's S1100287.

This sat amp is a UK 4CH sat amp, D0900900 / D0901284.

The data was taken per methods described in T080062-v3, using the diagrammatic setup shown on PAGE 1 of the Measurement Diagrams from LHO:86807.

The data was processed and fit using
    ${SusSVN}/trunk/electronicstesting/lho_electronics_testing/satamp/ECR_E2400330/Scripts/
         plotresponse_S1100287_ITMX_L1_ULLLURLR_20250916.m

Explicitly, the fit to the whitening stage zero and pole, the transimpedance feedback resistor, and foton design string are
Optic    Stage    Serial_Number    Channel_Number     OSEM_Name    Zero_Pole_Hz    R_TIA_kOhm    Foton_Design
ITMX     L1       S1100287         CH1                UL           0.0958:5.23     120           zpk([5.23],[0.0958],1,"n")
                                   CH2                LL           0.0966:5.28     120           zpk([5.28],[0.0966],1,"n")
                                   CH3                UR           0.0941:5.14     120           zpk([5.14],[0.0941],1,"n")
                                   CH4                LR           0.0955:5.23     120           zpk([5.23],[0.0955],1,"n")
                                   
  
The attached plot and machine readable .txt file version of the above table are also found in
    ${SusSVN}/trunk/electronicstesting/lho_electronics_testing/satamp/ECR_E2400330/Results/

Per usual, R_TIA_kOhm is not used in the compensation filter -- but after ruling out an adjustment in the zero frequency (by zeroing the phase residual at the lowest few frequency points), I nudged the transimpedance a bit to get the magnitude scale within the ~0.25%. shown in the attached results. Any scaling like this will be accounted for instead with the absolute calibration step, i.e. Side Quest 4 from G2501621, a la what was done for PR3 and SR3 top masses in LHO:86222 and LHO:84531 respectively.
Non-image files attached to this comment
jeffrey.kissel@LIGO.ORG - 11:45, Wednesday 24 September 2025 (87126)
Here's the characterization data and fit results for  S1100117 , assigned to BS M2 ULLLURLR OSEMs.

This sat amp is a UK 4CH sat amp, D0900900 / D0901284.

The data was taken per methods described in T080062-v3, using the diagrammatic setup shown on PAGE 1 of the Measurement Diagrams from LHO:86807.

The data was processed and fit using
    ${SusSVN}/trunk/electronicstesting/lho_electronics_testing/satamp/ECR_E2400330/Scripts/
         plotresponse_S1100117_BS_M2_ULLLURLR_20250917.m

Explicitly, the fit to the whitening stage zero and pole, the transimpedance feedback resistor, and foton design string are
Optic    Stage    Serial_Number    Channel_Number     OSEM_Name    Zero_Pole_Hz    R_TIA_kOhm    Foton_Design
BS       M2       S1100117         CH1                UL           0.0970:5.31     120           zpk([5.31],[0.0970],1,"n")
                                   CH2                LL           0.0975:5.33     120           zpk([5.33],[0.0975],1,"n")
                                   CH3                UR           0.0967:5.30     120           zpk([5.30],[0.0967],1,"n")
                                   CH4                LR           0.0955:5.22     120.375       zpk([5.22],[0.0955],1,"n")
                                   
  
The attached plot and machine readable .txt file version of the above table are also found in
    ${SusSVN}/trunk/electronicstesting/lho_electronics_testing/satamp/ECR_E2400330/Results/

Per usual, R_TIA_kOhm is not used in the compensation filter -- but after ruling out an adjustment in the zero frequency (by zeroing the phase residual at the lowest few frequency points), I nudged the transimpedance a bit to get the magnitude scale within the ~0.25%. shown in the attached results. Any scaling like this will be accounted for instead with the absolute calibration step, i.e. Side Quest 4 from G2501621, a la what was done for PR3 and SR3 top masses in LHO:86222 and LHO:84531 respectively.
Non-image files attached to this comment
jeffrey.kissel@LIGO.ORG - 11:48, Wednesday 24 September 2025 (87127)
Here's the characterization data and fit results for  S1100088 , assigned to ETMY L1 (UIM) ULLLURLR OSEMs.

This sat amp is a UK 4CH sat amp, D0900900 / D0901284.

The data was taken per methods described in T080062-v3, using the diagrammatic setup shown on PAGE 1 of the Measurement Diagrams from LHO:86807.

The data was processed and fit using
    ${SusSVN}/trunk/electronicstesting/lho_electronics_testing/satamp/ECR_E2400330/Scripts/
         plotresponse_S1100088_ETMY_L1_ULLLURLR_20250916.m

Explicitly, the fit to the whitening stage zero and pole, the transimpedance feedback resistor, and foton design string are
Optic    Stage    Serial_Number    Channel_Number     OSEM_Name    Zero_Pole_Hz    R_TIA_kOhm    Foton_Design
ETMY     L1       S1100088         CH1                UL           0.0968:5.29     120           zpk([5.29],[0.0968],1,"n")
                                   CH2                LL           0.0956:5.23     120           zpk([5.23],[0.0956],1,"n")
                                   CH3                UR           0.0955:5.22     120           zpk([5.22],[0.0955],1,"n")
                                   CH4                LR           0.0959:5.24     120           zpk([5.24],[0.0959],1,"n")
                                   
  
The attached plot and machine readable .txt file version of the above table are also found in
    ${SusSVN}/trunk/electronicstesting/lho_electronics_testing/satamp/ECR_E2400330/Results/

Per usual, R_TIA_kOhm is not used in the compensation filter -- but after ruling out an adjustment in the zero frequency (by zeroing the phase residual at the lowest few frequency points), I nudged the transimpedance a bit to get the magnitude scale within the ~0.25%. shown in the attached results. Any scaling like this will be accounted for instead with the absolute calibration step, i.e. Side Quest 4 from G2501621, a la what was done for PR3 and SR3 top masses in LHO:86222 and LHO:84531 respectively.
Non-image files attached to this comment
H1 SQZ
sheila.dwyer@LIGO.ORG - posted 13:25, Tuesday 23 September 2025 - last comment - 14:13, Tuesday 07 October 2025(86836)
filter cavity length and backscatter

This is an alog I started before the power outage, because we were worried that the filter cavity backscatter was the reason for our intermittent squeezer noise.  (We now realize that the noise we are looking for is not from the filter cavity 87071.)

The overall message is that the filter cavity backscatter seems low compared to DARM, but there is a source of scattered light upstream of SFI2.

Filter cavity length

I've constructed a model of the filter cavity length loop using the foton filters for PRM in the CAL-CS model.  As noted in 78728 we need to modify the analog gains for M3 for FC2.  I've used a filter cavity pole of 34 Hz, and adjusted the sensor gain to get the model to match the measured open loop gain (plot).  The measurement used in that plot has poor coherence below 5 Hz, which explains why the model doesn't seem to fit there. This model also matches the cross over measured by injected at M1 LOCK L well (plot)

The next plot shows the uncalibrated error signal (measured at LSC DOF2 IN1), with the loop correction applied (error_spectrum * (1-G)), and a line which I've added as a crude estimate of sensor noise.  You can see that there seems to be a bump in sensor noise around 100 Hz that isn't included in my rough estimate, I am not sure what that is.  

The next plot shows calibrated length noise

Backscattered power

Using the measurement of excitations on ZM2 in 86778,we can estimate the amount of backscattered light that is reaching the filter cavity.  The DCPD spectra, calibrated into RIN and with the DARM loop removed are plotted here and here with different FFT lengths.  Next time if we do this measurement with a lower frequency and higher amplitude excitation we will be able to use a longer FFT length for the plot and still se

I've made a model of the noise caused by backscattered light using equation 4 (and 5) from P1200155.  The excitation was a 1Hz 100 count excitation into test L, in the osems this showed a peak to peak amplitude of 0.37 um, and to go from optic motion to path length change we need roughly a factor of 4 since ZM2 is at a low angle of incidence and it is double passed.  To match the shelf frequency in the measurement I had to increase the amplitude used in the model by a factor of 3.4.  Using a QE of 100% gives a PD responsivity of 0.858 A/W, and 46.6mW of power on the OMC PDs.  This model doesn't include any phase modulation from any other elements in the optical path, but the real measurement does, which is why the measurements shows a nice shelf but the model shows a series of peaks when I use a longer FFT. I think would be less apparent if we make the measurement with a lower frequency higher amplitude excitation next time. 

The result of this shows that we have 12 pW of scattered light passing ZM2, since backscatter that reaches the filter cavity should all be reflected back towards the IFO along with the squeezing this means that we have 12 pW of scattered carrier from the OFI reaching the filter cavity.  Comparing this to table 1 of T1800447 this is a lower scattered light power reaching the diodes than expected, for a similar level of carrier light reaching the DC PDs, which suggests that all three Faradays are providing the isolation level expected or slightly better.  When driving ZM5, we get 12 nW of power scattered back to the interfometer, suggesting that there is a scattering source where we would not expect one to be.  This seems most likely to be upstream of SFI2, since we only expect nW of total scattered light downstream of SFI2.  If you are interested in looking at a diagram of possible scatters there is a VIP layout here, the beam which leaves B:M5 goes to a PD mounted on the ISI which is called B:PD1 and is intended to monitor light scattered from the OFI towards the squeezer.  

Coupling and noise projection

The last two plots here show the results of a filter cavity noise injection, similar to what Naoki did in 78579.  This suggests that this noise is large enough to include in our noise budget, but not nearly large enough to explain the excess noise we see in DARM when the filter cavity error signal is seeing extra noise. 

The code and data to produce this are in sheila.dwyer/SQZ/FilterCavity/fc_lsc_model.py

Images attached to this report
Comments related to this report
sheila.dwyer@LIGO.ORG - 11:29, Monday 06 October 2025 (87318)

I posted this as a comment on the wrong alog on Friday, adding it here now.  Also see follow up measurements with changes to SFI2 temperature, and the comparison measurement from LLO 87309

Power level heading towards HAM7 from OFI:

The power on the DCPDs is 47mW, and there is 12pW retro-reflected off the filter cavity, so the total isolation provided by OFI + SFI2 + SFI1 is 2.5e-10 in power ratio, or 96dB.  The OFI isolation ratio was measured to be 43dB in 79379.  If this is true it would imply that one of the SFIs is providing less than the 30dB isolation assumed in T1800447, and we should have 2uW of carrier light headed towards SFI2.

Our readback of the 1% pick off of light from the interferometer heading towards SFI2, B:PD1 (OFI PD A) says that we have 0.03mW on it, meaning 3mW from the IFO going towards SFI2, about 1mW of this would be carrier based on (87114),which seems too high.  

The responsivity of this PD was checked in 60284, and later double checked because it seemed low (the settings are still the same).  The similar PD OFI PDB has a measured responsivity of 0.25A/W and the excelitas website lists a peak responsivity of 0.6A/W at 850nm for these PDs.  (ffd-200h-si-pin) If we think that this calibration was mistaken and the real responsivity is more like OFI PD B, 0.25A/W, there is 0.72 mW of light from the OFI heading towards SFI2,  ~240 uW of carrier, the OFI isolation would only be 23dB, and the SFIs must be providing something like 36 dB each.  

Reflectivity:

If my interpretation of the fringe wrapping measurements into power are correct (12 nW of power is retroreflected from the path that includes ZM5), we are reflecting 50ppm of the carrier scattered toward HAM7 using the (recalibrated) 240uW value from OFI PDB, or 0.6% if we believe the isolation ratio measurement for the OFI and use the 2uW value.  B:BS1 is a 1%, so the maximum reflectivitiy we could get from scatter in the B:PD1 path would be 0.01%.  This means that the B:PD1 path can't explain the reflectivity needed if there is 2uW headed towards HAM7, and even if there is 240uW heading towards HAM7 this PD seems unlikely to explain the scatter, since it would need to reflect half the light that's incident on the PD.  Camilla did alog the check of the alignment (and the beam dump catching the retro-reflection off this diode: 65006

sheila.dwyer@LIGO.ORG - 14:13, Tuesday 07 October 2025 (87350)

Daniel looked at some of the excelitas website catalog and he thinks that our measurement of 0.06A/W could be a reasonable responsivity for the OFI PD A. LLO's responsivity for this PD is set to 0.065A/W.  

This morning we opened the squeezer beam divererter while Matt was doing single bounce OMC scans, (87342) when there was 9.25W incident on PRM.  

9.25W on PRM * 0.0299 PRM transmission * 0.25 (2 BS passes) * 0.03234  = 22.4mW expected arriving at OFI.  AS_C_NSUM is calibrated into Watts arriving at HAM6, which says 22.9mW for this time.  

OFI PD A reports a 1.1uW increase in measured power when the beam diverter opens (first attachment), meaning that there is about 100uW from the OFI sent to HAM7 in single bounce, or 0.4% of the light arriving at the OFI is sent to HAM7 according to this PD, or 23dB of isolation for this port.  The 43dB measurement I referenced above is isolation for HAM6 scatter, and it doesn't apply to the light sent to HAM7.

So, this suggests that perhaps we can trust this OFI PD readback, and perhaps there is about 1mW of carrier sent to HAM7 when we are in full lock.  This means that we need a reflectivity of 10ppm to explain our fringe wrapping measurement;  if the scattering happens behind the 1% beam splitter it should have a reflectivity of 10% to explain what we see.  

LLO has 50mA on the OMC PDs, compared to 40mA here, their OFI PD A reports 0.01mW power in full lock, 3 times less than what we see here.  

Images attached to this comment
H1 ISC
elenna.capote@LIGO.ORG - posted 13:16, Monday 22 September 2025 - last comment - 14:24, Tuesday 23 September 2025(87063)
AS WFS phasing updated

Today I rephased the AS WFS 45 segments.

To avoid lockloss, I transitioned the DHARD input matrix to AS WFS 45 A only so I could phase WFS B. Then, I switched DHARD to WFS B and phased WFS A. I switched by using the DHARD blend filters. Set the DHARD_P_B and DHARD_Y_B input matrix values to the desired value, then make sure the DHARD A and B blend filters have the same ramp time. Then, ramp the gain of one blend to zero and the gain of the other to one. I used a similar process here: 85774.

To get the phasing, I drove a DARM line at 255 Hz in DARM2 EXC, after engaging the EBS255 filter in DARM2 FM10. I was able to get good SNR with an excitation of 3000 counts.

I adjusted each segment to reduce the signal in I (red trace) and maximize in Q.  I was able to reduce the line height by between a factor of 2 to a factor of 5 on each segment. The phase changes were between 3-6 degrees on each segment. The light pink and blue traces show the phasing before I started.

This change was SFDed in both safe and observe, shown in attachments below. For some reason, AS A RF45 is in the ASCIMC model but AS B RF45 is in the ASC model.

I attached a comparison of the before and after for each segment. (Note, seg2 on WFS 45A had a strange behavior where it appears the line in Q reduced with the phase change, but that reduction was present before I started changing the phase.)

 

Images attached to this report
Comments related to this report
elenna.capote@LIGO.ORG - 16:46, Monday 22 September 2025 (87072)

I have reverted these phases since we don't see much benefit to using them right now, and there is a negative impact on the roll mode damping.

elenna.capote@LIGO.ORG - 14:24, Tuesday 23 September 2025 (87108)

I tried testing these phases while relocking. We can still lock RF darm with no problems. However, it doesn't make any difference in our ability to engage DHARD right after RF darm is locked ( in other words, we still can't engage DHARD after RF darm).

Since this doesn't give us any benefit, and screws with our roll mode damping, I say we don't use these new phases.

H1 IOO (ISC)
elenna.capote@LIGO.ORG - posted 12:18, Wednesday 17 September 2025 - last comment - 13:18, Tuesday 23 September 2025(86989)
IMC powers

We have now been locked for over 16 hours.

IMC REFL DC power is steady at 18.5 mW

IMC WFS A is at 0.95 mW and IMC WFS B is at 0.75 mW

The IMC power in is 62 W and the power at IM4 trans is 56.7 W

MC2 trans is about 9670 [mystery units]

This is reasonable power for IMC refl, but the WFS power is very low. These are the jitter witnesses, and jitter subtraction is not performing as well as it was before the power outage. I can think of several possible reasons for this, but I'm sure that having less than a mW of power isn't helping.

We may want to consider either a) increasing the power on the IMC refl path b) changing the splitter between IMC refl and IMC WFS to be a 50/50 instead of a 90/10, or c) some combination of the first two options that gets us reasonable power on both IMC refl and IMC WFS.

Images attached to this report
Comments related to this report
elenna.capote@LIGO.ORG - 14:20, Thursday 18 September 2025 (87006)

The numbers are confirmed to have held through the entire 40 hours of this most recent lock (killed by earthquake).

elenna.capote@LIGO.ORG - 13:18, Tuesday 23 September 2025 (87104)

Looking back before the power outage, the nominal IMC REFL and IMC WFS powers at 60 W PSL lock were 18.6 mW for IMC REFL, 0.95 mW for WFS A and 0.76 mW for WFS B. So, we are now back to operating with our nominal powers at these PDs, except that the waveplate was adjusted to reduce the power to these diodes by half.

So, if we went back to the old waveplate setting, we would have double these powers. This would be too much power for the IMC REFL diode.

We have chosen to not make any further adjustments to this path.