In the morning, we placed an iris placed between the IFI input baffle and the IFI HWP baffle (irisposition.png). We used an IR sensitive DSLR as a viewer to center the iris for the forward-going beam, and observed the back side of the iris using the same camera to see the PRM reflection.
This allowed us to set the PRM angle in much better accuracy than using a card with a bigger-than-needed hole handheld at an inconvenient location and observe with naked eyes through the laser glasses. We had to close down HAM3 cover as well as one side of HAM2 so PRM quiets down, but the retro-reflection accuracy was like +-50 urad (rather than +-500urad of yesterday).
With this new PRM alignment ([P, Y]=[-1165, +750]), I was able to center REFL sensors despite that RM2 was so close to railing, RM2 YAW offset was -1800urad. (ASC_REFL_balanced_20260602_morning.png and ASC_REFL_balanced_but_RM2_close_to_railing_20260602_morning.png.)
Nice thing was, at this point the beam was much closer to the center of IFI input baffle, IFO REFL beam clipping-like thing observed on the IFI input baffle was completely gone as well as the clipping on IM4 baffle. So things looked better in general than they were yesterday.
RM2 was so uncomfortably close to railing nobody should leave it like that before pumping down, so I decided to relieve RM2 by tilting IM1. (Calculation is in alog 90404.)
I thought RM2 should be rotated counter-clockwise seen from the top because that would mean the positive YAW offset, we added negative 100urad to IM1 YAW offset (i.e. from -887.1 to -987.1 urad) based on my calculation, expecting to shave off 300 or 400 urad from the RM2 YAW. We reset the iris position for the forward-going beam, then reset the PRM angle, fully opened the iris and started centering the REFL sensors. Disappointingly, we couldn't center them, RM2 railed.
We wasted some time trying to somehow find a magic slider values for RMs and going through how the angle of IM1 propagates to RMs, but it turns out that RM alignment sliders seem to have the opposite sign than all other suspensions. As far as we believe that the OSEM sensor (not actuator) produces positive DAC output that is proportional to the number of photons, the conclusion is that the sign of the sliders is wrong for both RM1 and RM2.
This is clearly shown in wrongsign.png where slider offsets of RMs were zero-ed one by one (top row) while the OSEM sensors in Euler bassis (bottom) were observed. Ignore the cross coupling from P actuation to Y sensing. In a suspension that follows the LIGO sign convention, the slider and the sensors move in the same direction roughly by the same amount. RM is the opposite of that, sensors move in the opposite direction of the sliders. We have done the same test for RMs, PM1 (see PM_is_good.png), OM1 (because they're all tip-tilts) and IM1 (because we touched it today) and confirmed that RMs are an exception.
If you're not sure about the rotation convention of LIGO optics, positive YAW rotation means counter-clockwise seen from the top. This will increase the light power on RIGHT OSEM sensors and decrease it on the LEFT. Given that the ADC reports positive voltage (i.e. positive counts), and given that usually OSEM YAW signal is proportional to voltage(RIGHT)-voltage(LEFT), positive physical YAW rotation will produce positive OSEM YAW change. See my cartoon (LIGO_YAW_sign_convention.jpg).
Now, RM1, RM2 and PM1 sensing look identical to me (osemsensors_look_good.png).
All OSEMs produce positive numbers for all three suspensions, there's no sign flip in the filters, filter output sign is only determined by whether or not the input is bigger or smaller than the mid-point offset, they all use identical OSEM2EULER matrix as well as SENSALIGN matrix, and the sign of DAMP_P as well as DAMP_Y are all according to the filter outputs and these matrices. So the sensors for RM1 and RM2 are working in the same way as PM1, they're fine.
The conclusion to me is that somehow the actuation sign is wrong for RM1 and RM2.
Rahul told me that the magnet polarity was wrong for RM1 or RM2 and people spent some time to address that issue. But that sounds like the actuation side issue which should NOT affect the validity of the sensors. Unless people tell me that somehow the physical UL/UR/LL/LR sensors are wired to the LR/LL/UR/Ul channel or something, we just believe the OSEM sensors and assume that the sign of sliders is flipped.
Regardless of the reason of the sign flip, we'll proceed to move IM1 in the opposite direction, i.e. somewhere between this morning and Friday.
FYI below is the history of IM1 YAW offset in the past week. The change made on Monday was motivated by the "need" to relieve RM2, but now that we know that the PRM retroreflection accuracy matters, I'm not sure if it would have been impossible to center REFL ASC sensors on Friday if we used the iris technique to align PRM.
| Friday last week | Monday | Monday | This morning | This afternoon | |
| IM1 YAW slider | -387urad | -887urad | -887urad | -887 | -987 |
| PRM retroreflection | questionable | questionable (YAW offset = 1000urad) | questionable (YAW offset = 700 urad) |
better (YAW offset = 750) |
better (YAW offset = 1000) |
| REFL ASC centered | No (RM2 rails) | No (RM2 rails) | yes | yes (RM2 close to railing) | no (RM2 rails) |
Sheila, Begum, Camilla, Fil, Dave, Erik
Day 2 of the HAM7 work, follow on from 90426. The CDS/EE team fixed the FC1 top mass, unsure how. We found we then could not trust the sliders at all. We reverted all optics (apart from FC1) to the 90183 time. We tired putting the FC1 M3 WIT back to this time but the beam clipped on the OPOS.
Then we moved FC1 to center the IR on the SQZT7 irises. Got perfectly centered on far iris, a little high on iris at the bottom of the periscope.
Begum and Sheila then moved the ZM4 iris to mark this alignment.
Attached is current sliders.
Adding some other details:
We became concerned that we could not reproduce the alignment that we had yesterday that got IR beam onto SQZT7 IR PD. We were able to get the beam back without cliping by setting the ZM sliders back to the screenshot from yesterday (90426), and restoring FC1 M3 WIT to where they were yesterday (-85 P, -34 Y). This is not the same alignment of FC1 as O4, or as it was in our reference time 90183, but it convinced us that the ZMs hadn't moved since yesterday.
Camilla then reverted the changes she made to ZM4 + ZM5 sliders, so that they now match our in vacuum reference time for IR reaching SQZT7, 90183. She also set the FC1 sliders to reproduce the FC1 M3 wit from that reference time (P -49, Y -13) . The beam was then not centered on the SQZT7 irises, and was clipping somewhere on the VIP. Camilla then adjusted FC1 pitch to reduce the clipping and center the beam on the SQZT7 irises. This brought FC1 pitch back toward's yesterday's value (now it is at -144 urad P, -31 yaw).
We centered the iris in front of ZM4, and we think this iris will be good enough for us to recover alignment onto SQZT7 once we have recovered FC1 alignment to O4, fixed the clipping on the VIP.
TITLE: 06/02 Day Shift: 1430-2330 UTC (0730-1630 PST), all times posted in UTC
STATE of H1: Planned Engineering
INCOMING OPERATOR: None
SHIFT SUMMARY: HAM3 FAROing finished, HAM2, BBS, and SPI work continue. The LVEA is in LASER HAZARD.
LOG:
| Start Time | System | Name | Location | Lazer_Haz | Task | Time End |
|---|---|---|---|---|---|---|
| 19:26 | SAF | Laser HAZARD | LVEA | YES | LVEA is Laser HAZARD | 21:23 |
| 14:54 | FAC | Kim | LVEA | Y | Tech clean | 17:34 |
| 15:08 | FAC | Randy | EndX | N | Engine hoist inspection | 15:54 |
| 15:51 | FAC | Chris | LVEA | Y | PEst contractor walkthrough | 16:03 |
| 15:55 | FAC | Randy | LVEA | Y | remove lights @bsc platform | 17:36 |
| 15:57 | FAC | Keita, Rahul, Disha | LVEA | Y | HAM2 work | 19:14 |
| 16:04 | FAC | Chris | Out Bldgs | - | Pest control | 17:17 |
| 16:05 | IAS | Jason, RyanC | LVEA | Y | MC2 FAROing | 18:39 |
| 16:15 | vac | travis.gerardo.jordan.jake.owen | lvea | - | XBeamMani VENT | 18:32 |
| 16:15 | vac | travis.gerardo.jordan.jake.owen | lvea | - | GV2 OPENING (Gerardo out @1833) | 18:42 |
| 16:26 | SLiC | betsy.ryanS.anamaria.robert | lvea | Y | baffle prep at bsc1 (Betsy out @1900) | 20:17 |
| 16:43 | CRS | shoshana.jim.alexandra | h2psl | - | CRS | 19:22 |
| 16:43 | SPI | jeff.jennie.sina | OpticsLab | yes | SPI (Jennie, Sina out @1939) Jennie back in 20:45 | 21:32 |
| 16:45 | bbss | ibrahim.tom.ollie | West Bay | - | Test stand work | 19:17 |
| 16:46 | sqz | sheila.begum.camilla | lvea | yes | HAM7 SQZ (Sheila, Begum out @1913) | 19:28 |
| 18:39 | CC | Ryan C | LVEA | Y | Checking on HAM7 dust monitor | 19:24 |
| 18:49 | CDS | Fil | LVEA | yes | Troubleshooting FC1, swap DAC card | 20:45 |
| 20:13 | SUS | Betsy, Tom, Oli | LVEA | Y | BBSS test stand cabling, Oli in @ 20:42, Tom out 20:58, Oli out 21:02 | 22:12 |
| 20:20 | VAC | Travis | LVEA | Y | Gatevalve BTmanifold swap | 21:35 |
| 20:28 | SUS | Mitch | LVEA | Y | Test stand work | 22:45 |
| 20:35 | VAC | Gerardo | Yend | n | Grab tools | 21:13 |
| 20:36 | SUS | Ibrahim | LVEA | Y | Join Mitch, test stand bbs | 22:45 |
| 20:37 | SEI | Jim, Shoshana, Alexandra, Arnaud | LVEA, H2 PSL | Y | CRS work, Arnaud in @ 21:20 | Ongoing |
| 20:59 | OPS | TJ | LVEA | Y -> N | LASER hazard transition | 21:27 |
| 21:12 | SQZ | Camilla, Arnaud | LVEA | Y | Grab power meter | 21:20 |
| 21:28 | FAC | Richard | LVEA | N | Safety checks | 21:43 |
| 21:31 | SEI | Jim | LVEA | no | Lock BSC3 ISI | 21:51 |
| 21:33 | SPI | Jennie | LVEA | N | Check test stand for allen key | 21:42 |
| 21:41 | SUS | Jeff, Sina | LVEA | n | Looking at BBS | 22:00 |
| 21:43 | SLiC | Robert, Anamaria, Ryan S | LVEA | Y | BSC SLiC baffling | Ongoing |
| 21:48 | OPS | TJ | LVEA | N | Check with Jim, laser transition | 22:03 |
| 22:00 | SUS | Disha, Rahul, Keita | LVEA | Y | HAM2 work, Disha Keita out at 23:17 | 23:19 |
| 22:01 | SQZ | Sheila | LVEA | Y | HAM7 work | Ongoing |
| 22:06 | SQZ | Camilla | LVEA | Y | HAM7 work | Ongoing |
| 22:09 | SAF | LASER HAZARD | LVEA | Y | The LVEA is LASER HAZARD | 02:09 |
| 22:15 | VAC | Travis, Gerardo | LVEA | Y | Survey viewports, travis out 22:50 | 23:15 |
| 22:26 | PEM | TJ | Ends | N | Check on dust monitor pumps | 23:04 |
| 22:27 | SPI | Sina | Optics lab | LOCAL | SPI work | 23:27 |
| 22:46 | H2PSL | Fil | H2PSL | Y | h2psl work | 23:30 |
| 22:47 | SLIC | Jennie W | BSC2 | Yes | batteries | 22:48 |
Jennie Wright
Summary: Started debugging JAC WFS, two corrections made in WFS segment -> euler basis matrix.
Not sure if this change was made by the power outage or it has been set up wrong the whole time but the channels for segment 3 and 4 in the Q phase matrix for both JAC WFS QPDs were wrong.
This meant yaw = + segment 1 - segment 2 + segment 3 - segment 4 which would be some kind of weird pringle mode.
I corrected the sign, and also updated the note at the bottom right of the JAC_WFS_SETTINGS screen to reflect the sign that the WFS should have (the previous note here described the IMC WFS euler basis as I had copied the medm screen from the IMC custom screens).
now yaw = +1 -2 -3 + 4.
NB: JAC WFS euler basis matches other ASC QPDs but the IMC has P & Y swapped due to the persicopes in HAM2 and so has yaw = +1 + 2 -3 -4 and pitch = +1 -2 -3 +4.
New values for Q matrices are accepted in sdf, as is the PSL PZT mirror offset values that align the beam to the JAC as this has changed since it was last set before the power outage.
I also had a check through the wiring in the simulink h1ascimc/jac model for both WFS_A and WFS_B and this looks to be the correct wiring for each segment.
Summary: The QOSEMs on the BBSS will see a vertical sag of ~50um. The LF and RT QOSEMs should be offset 50um low of center in there x axis, and the F1, F2, F3, SD QOSEMs should be offset 50um low of center in there y axis; such that they will be well centered when under vacuum.
In T2600176 (write up to come) we calculate the expected vertical sag of the BBSS suspension chain to be 58um at M1. This is slightly larger than the 50um predicted for the BSFM (T1100616), which is consistent with the fact the payload is lighter. To verify these calculations, we pulled OSEM data from the last pump down of the BSFM (April 26 2025 = 1428872333)), and see that there was a vertical sag on the LF and RT BOSEMs of ~35um. See the figure attached.
This is about 10um less than predicted by the calculations for the BSFM, a trend which is also seen on the Quads (LHO alog 15887). As such we suggest that the BBSS should have its M1 QOSEMs offset by ~50um low of center, also about 10um less than the theoretical value. The M2 and M3 OSEMs do not need to be offset, as they don't measure in the vertical direction.
A. Effler, R. Schofield, R. Short
This morning, we started working in BSC1 to prep for the new cage baffle installation on ITMY. Before going into any chambers, Anamaria and Robert moved ITMY to center the OpLev signals. Once at BSC1, Anamaria and I were in the chamber while Robert handled tools in and out as well as kept an eye on particle counts. We started by attaching the long locker bracket on the arm cavity baffle (ACB), then pushed the ACB up and away from the quad after undoing the hinge assembly. While holding the ACB up, we inserted and screwed in the wedge that keeps the ACB away from the quad. With this out of the way, we locked down the bottom two stages of both the main and reaction chains of ITMY by pushing in the earthquake stops until they just came into contact. We then went about replacing the stops on the HR surface of the ITM. After this, we realized that we meant to get measurements of the test mass and reaction mass before they were locked down, so we unlocked the bottom stages of each chain so they were free hanging and took measurements, then re-locked the stages. At this point, we stopped for lunch.
Ibrahim, Tom, Oli
Yesterday we were able to take our first set of transfer functions with the QOSEMs! They are looking good. The measurement files can be found in /ligo/svncommon/SusSVN/sus/trunk/BBSS/H1/BS/SAGM1/Data/2026-06-01_1700/2026-06-01_1700_H1SUSBS_M1_WhiteNoise_{L,T,V,R,P,Y}_0p02to50Hz.xml. I have committed the data files to svn as r13024, but I have not yet exported them or analyzed them in matlab because I want to make sure I do it the same way that LLO has decided to do it.
Tom, Ibrahim, Oli
Yesterday we made a lot of progress on the BBSS, specifically on the QOSEMs.
First, we went around between all the QOSEMs and worked on centering in the X and Y directions. Once we got everything within +/-1000 counts, we made sure the cam adjusters were all tightened. We did this with the constant current switched ON for all the QOSEMs at the satamp, and with the whitening OFF on the satamp but had the compensation ON in medm.
Then we left and were ready to try damping and transfer functions.
We switched the constant current OFF for the QOSEMs now, since we wanted the satamp to be able to adjust the currrent to keep it the same. We also ended up needing to turn the whitening compensation OFF in the model to be able to see the actual amount of movement since it had also been OFF at the satamp.
While trying to damp, we found that we needed to swap the sign of the damping gains to get damping to work. We believe this is because these QOSEM coils, which were made out of older BOSEMs, had the opposite wires from normal connected up, leading to the current flowing the opposite way than expected.
We also needed to lower some of the damping gains.
I've attached a screenshot of how our damping filter bank looks now, but it seems to be working well!
Yesterday I made some changes to the h1suslo12 model(before, after). We were now done with the BOSEMs on the BBSS, so we needed the BBSS model to be able to drive to the DAC for M1 so we could test the QOSEMs. We also needed to be able to switch the BIO on the BBSS, so we also needed to connect the BIO senders and receivers back up to be able to communicate with MC2, which controls the BIO switching for the b2h34 models.
To be able to run this updated model, we would also need to stop the h1susbs model so there wouldn't be mulitple sets of channels trying to write to the same DAC.
Erik and Jonathan (90422) helped with stopping h1susbs, and with building and restarting h1suslo12.
J. Kissel, S. Koehlenbeck (in person!) D2400107 for the annotated layout of SPI Pathfinder ISIK's Transceiver Assembly. After an easy recovery from other-the-weekend, site-wide power outages (LHO:90413), we resumed last week's investigations of what might be causing the MEAS IFO to drift (LHO:90382). %%%%%%%%%%%% Executive Summary: No magic bullet found. Today we ruled out the collective idea we all had that the picomotor-actuated mounts were the problem (LHO:90384) by replacing every pico-actuated mount with manually driven mounts. We also replaced the last optic we hadn't swapped in the MEAS path to the MEAS IFO -- M_B1. No impact -- we still see the MEAS IFO alone drift. %%%%%%%%%%%% It was only a half-day of forward investigative progress given the power outage, but having Sina on-site really helped confirm my (in)sanity and accelerate investigatory iterations. Upon arrival in the lab Sina re-confirmed my construction and alignment of the D2400107-v5 board and the quality of things: - Centering on optics with IR card :: good. - Centering on photodiodes with IR camera :: good. - No stray beams (even from what would be AR coatings of beam splitters) :: good. - The as-we-left-off Friday assessment that with M_M2 and M_B4 down-graded to manually driven mounts, we still see drift. - Having one or the other REF or MEAS beam into the MEAS IFO blocked, that the power on each beam is stable without drift. - After an alignment drift, quickly touching the alignment of all three M_M2, M_B4, and M_M1 cannot recover the MEAS IFO efficiency. As we continue to grasp at straws, we replaced the last optic in the MEAS path into the MEAS IFO -- M_B1. This optic splits the MEAS beam on the board feeding it to the MEAS and REF IFOs, so we were hesitant to swap it. But now that we're getting so good at re-aligning the board after changing out optics (once optic is placed, re-alignment can be done within 2-5 minutes), we figured we must. So, all at the same time, we - unlocked all manual drive set-screws on all optics (recall the REF path had been "locked down" the day I'd gotten ~95% efficiency), - loosened and re-tightened R_B1's 1/4-20 bolt that secured the mount to the breadboard. It wasn't "loose" but it wasn't "cranked on" either. - Replaced M_B1 optic - Replaced the M_B1 manual-drive pitch actuator's 1/4-100 alignment screw and bushing because it was "crunchy" and "stiff" to use. This had been this way, but when I was driving solo I'd suffered thru it and locked it down the day I got 85% efficiency on the MEAS IFO and didn't look back. Now what we're touching the mount anyways, we figured we might replace it in case the issue was some sort of stick-slip thing happening. Upon doing all these things ... things looked solid for ~10 minutes... and then the efficiency started to drift again. Especially after turning on the Clean Room fans. This again resurrects the theory we thought debunked: "it must be the environmental conditions..." Why did we rule this out before? (1) The REF IFO does not see any drift. Ever. The board is so small and so local, and both IFOs are sampling the same beams. *Very* hard to believe that the few differences in paths and path lengths would cause only ONE of the IFOs to drift. The environment should impact both IFOs equally. (2) We *do* see phase noise when we make environmental changes -- as expected. Path length differences caused by - physically manipulating the board, its mounts, or optical fibers, - waving hands over the board - talking, even at a medium volume (3) Any environmental change in the efficiency we can cause -- be it: - clean-room fans ON/OFF, - clean-room or room lights ON/OFF, - people coming in-and-out of the clean room, - standing in different positions around the optical table -- they all only some-times seem correlated, and never is it reproducible. But we've run out of things to change, so today we're going to try to adjust the environment and/or other things that *should* be common to the IFOs: (a) We're gunna being in an incandescent lamp to try to create thermal gradients (b) We'll put on our tin-foil hats and enclose the breadboard in a temporary foil enclosure (c) We'll try adjusting the NPRO seed laser controller's parameters (like diode temperature) ...and keep trying all the other wild theories we can concoct.
TITLE: 06/02 Day Shift: 1430-2330 UTC (0730-1630 PST), all times posted in UTC
STATE of H1: Planned Engineering
OUTGOING OPERATOR: None
CURRENT ENVIRONMENT:
SEI_ENV state: MAINTENANCE
Wind: 8mph Gusts, 4mph 3min avg
Primary useism: 0.02 μm/s
Secondary useism: 0.14 μm/s
QUICK SUMMARY:
A ~2 week trend of the LVEA temperatures.
1610-1756 Covering Ops while RyanC does morning FARO work, and then handing off to TJ.
Have had a few connection drops for the EY Dust Monitor
LOG:
Yesterday (June 1) I replaced a failed power supply on the Comtrol communication device at EY that bridges a dust monitor and a weather station to the network.
Workstations were updated and rebooted. This was an OS packages update. Conda packages were not updated.
Today started with removal of the HAM7 +X and -Y doors, WP 13283. These were already on 4 bolts/piece, so removal was relatively quick. Nothing to note other than the usual O-ring sticking business. The 2x 12" CF blanks on the +Y door were also removed for ISI locker access. Since the final cleaning happened ~1 hour from door removal, particle counts were very minimally elevated, 40 @ 0.3um and 20 @ 0.5um (see pic).
We then moved on to the X-beamtube manifold vent work, WP 13284. The X-manifold turbo pump was valved out. We then cycled GV7 open, then hard closed again. The GV opened at 10 psi, and hard closed at 20 psi, so we believe the piston O-ring replacement is working well. Then, the X-manifold vent was started. After burping the system a few times and confirming there was no communication past GV7, we started venting the manifold section. We noted that the Kobelco's duty cycle seemed to increase audibly as the pressure in-vacuum rose, which isn't surprising given that we have 7 doors and 2x 12" ports open on the corner volume, so we elected to keep the vent slow, maybe 5 torr/minute. We stopped the vent for the night at around 400 torr. Tomorrow, we'll finish venting and open GV2.
(Travis S., Gerardo M.)
We restarted the vent on Tuesday morning, and after 45 minutes the XBM was fully vented. We opened GV2 after the XBM was fully vented, the annulus system was vented to be able to open the gate valve. No issues were encountered during the vent process or the opening of GV2.
Sheila, Camilla, Disha
After Jim locked the ISI, Marc bypassed the high voltage interlock, and Camilla restored the psams, we reset the alignment sliders following 90483 which was in air. The dither locking worked without any issue, and we saw that the beam was low on both the irises in the homodyne path on SQZT7. Camilla adjusted the alignments of ZM4+ZM5 to center the beam on the irses, screenshot attached shows the alignment that she found.
We placed an iris in front of ZM4 for this alignment, we were able to look from the +X side of the chamber to check the centering. We also took photos of the IR/green co-alignment, it looks good coming right off the VIP, but looking right after ZM3 you can see that there is a small misalignment in yaw. We will continue with placing irses tomorow.
This morning we reverted the -710 counts on H1:SYS-MOTION_C_PICO_J_MOTOR_3_X_POSITION (H:M2 yaw), undoing the change that we made in 89596. This seems to have improved the co-alignment, I will attach a photo here to compare to the co-alingment photos from yesterday (90426)
We also lowered the PZT scan range to get the OPO seed dither locking to work well, as it was trying to lock at the top of the PZT range and not staying locked. (line 654 of the OPO guardian).
We attempted to go to the alignment in 89694 to check the alignment of FC1, but we saw that FC1 was not actuating. This is probably why Camilla had to adjust the alignments of ZM4 + ZM5 yesterday. 90426. The CDS team is working on the issue with FC1 alignment.