christopher.soike@LIGO.ORG - posted 14:53, Monday 22 September 2025 (87067)
Water shut-off to VPW/Weld Shop and Staging Bldg-Overnight only
Chris and Eric O. will be isolating the water supply to the VPW/Weld Shop overnight tonight. We believe there is either a new leak or an existing one that has worsened significantly.
As a result, there will be no running water on either end of the VPW building from 3:15pm today until early tomorrow morning. 
If you have any questions please reach out to Eric or me.

Updated: The overnight water isolation will include the Staging Building. No water in this building from now until early tomorrow morning. 
H1 SUS
oli.patane@LIGO.ORG - posted 13:59, Monday 22 September 2025 - last comment - 16:48, Monday 22 September 2025(87060)
ETMY Roll Mode rang up, found new settings

Elenna, Jeff, Oli

After Elenna updated the DHARD phasing (87063), the ETMY roll mode started ringing up. The previous settings we had on it were +30 deg and G = 40. We started testing out different settings to try and damp it, and along the way we changed a few other things.

First, we plotted ASC-AS_{A,B}_RF45_Q_{PIT,YAW} and found that AS 45Q WFS B YAW sees this roll mode better than WFS A YAW, which is what we had it on before, so we swapped to using that sensor in the AS WFS selector on the bounce and roll monitor screen and that has been accepted into sdf.

Then, we saw that the current Bounce & Roll filter in ETMY_L2_LOCK_{P,Y}, EvanBR (FM3), wasn't notching out the ISC control signal as much as we would like, so Elenna and Jeff created a new filter, OliBR (FM1), that filters out more of the control noise to a magnitude better than EvanBR. Here's the magnitude and phase difference between the two - where blue is EvanBR and red is OliBR. The cursor on the magnitude plot is at the frequency that this mode is at, 13.75977 Hz. Note that the phase plot shows different x limits on the frequency, as we wanted to show that we don't lose a lot of phase margin between the old and new filters. We loaded this new filter in for ETMY L2 LOCK P and Y, and swapped over to using this filter module instead of FM3. These changes have been accepted in sdf.

Finally, after lots of testing and installing this new filter, we were able to find damping settings that are working to damp ETMY. The new settings we found that worked to damp ETMY (slowly) is +60 deg, G = -45. We have been able to bump up the gain to G = -100 for a few minutes at a time to get a lot of damping for ETMY, although it also rings up ETMX a bit every time, so we are going between G = -45 and G = -100 to minimize that. We also unmonitored in OBSERVING ETMY_M0_DARM_DAMP_R and ETMY_M0_DARM_DAMP_R_GAIN in order to continue being able to work on damping while in Observing.

 

Images attached to this report
Comments related to this report
elenna.capote@LIGO.ORG - 14:09, Monday 22 September 2025 (87065)

Here are some safe SDFs. We got permission of Jenne to briefly step out of observing to load the guardian and update safe SDFs so there were no issues later on.

ISC_LOCK guardian sets the tramp and gain of the ETMY roll mode damping. The guardian will now ramp the gain to -45.

SDF safe will set the ETMY roll mode damping filters to FMs 1,3,4,8. It will also set the L2 lock filter to FM1 instead of FM3 for the new bounce/roll bandstop.

The outmatrix for the roll mode is now set to AS B, so that is SDFed in safe.

I also SDFed the AS WFS phases in safe because I forgot to do them before (it was previously done in observe).

We left channels monitored in SAFE, because we want SDF revert to put in these settings, but unmonitored the gains and filters in observe so we can adjust things during observing if we find better settings.

Images attached to this comment
elenna.capote@LIGO.ORG - 16:48, Monday 22 September 2025 (87073)

We have decided to revert the AS WFS phasing, which means we have reverted all of these changes.

REVERTED:

  • AS WFS phasing
  • outmatrix for damping is back to AS A
  • the damping is back to +30 deg phase, gain 40
  • guardian updated and loaded
  • remonitored gain and filter channel
  • everything SDFed in safe and observe

NOT REVERTED:

  • ETMY bounce/roll filter "aka OliBR" is still in place.
H1 ISC
elenna.capote@LIGO.ORG - posted 13:16, Monday 22 September 2025 - last comment - 14:24, Tuesday 23 September 2025(87063)
AS WFS phasing updated

Today I rephased the AS WFS 45 segments.

To avoid lockloss, I transitioned the DHARD input matrix to AS WFS 45 A only so I could phase WFS B. Then, I switched DHARD to WFS B and phased WFS A. I switched by using the DHARD blend filters. Set the DHARD_P_B and DHARD_Y_B input matrix values to the desired value, then make sure the DHARD A and B blend filters have the same ramp time. Then, ramp the gain of one blend to zero and the gain of the other to one. I used a similar process here: 85774.

To get the phasing, I drove a DARM line at 255 Hz in DARM2 EXC, after engaging the EBS255 filter in DARM2 FM10. I was able to get good SNR with an excitation of 3000 counts.

I adjusted each segment to reduce the signal in I (red trace) and maximize in Q.  I was able to reduce the line height by between a factor of 2 to a factor of 5 on each segment. The phase changes were between 3-6 degrees on each segment. The light pink and blue traces show the phasing before I started.

This change was SFDed in both safe and observe, shown in attachments below. For some reason, AS A RF45 is in the ASCIMC model but AS B RF45 is in the ASC model.

I attached a comparison of the before and after for each segment. (Note, seg2 on WFS 45A had a strange behavior where it appears the line in Q reduced with the phase change, but that reduction was present before I started changing the phase.)

 

Images attached to this report
Comments related to this report
elenna.capote@LIGO.ORG - 16:46, Monday 22 September 2025 (87072)

I have reverted these phases since we don't see much benefit to using them right now, and there is a negative impact on the roll mode damping.

elenna.capote@LIGO.ORG - 14:24, Tuesday 23 September 2025 (87108)

I tried testing these phases while relocking. We can still lock RF darm with no problems. However, it doesn't make any difference in our ability to engage DHARD right after RF darm is locked ( in other words, we still can't engage DHARD after RF darm).

Since this doesn't give us any benefit, and screws with our roll mode damping, I say we don't use these new phases.

H1 DetChar (DetChar)
sayantan.ghosh@LIGO.ORG - posted 12:43, Monday 22 September 2025 (87062)
Data Quality Shift Report 2025-09-15 to 2025-09-21

Link to full report

H1 SQZ
camilla.compton@LIGO.ORG - posted 12:39, Monday 22 September 2025 (87061)
Turned up CLF Power for Test this morning, reverted.

Sheila, Camilla

We had wanted to turn down the CLF launch power to see if ti had any effect on SQZ noise, but couldn't turn down by a factor of 2. Could only reduce from 0.06 to 0.05. We instead we doubled CLF launch from 0.06 to 0.12mW. Note these numbers were when the OPO was unlocked and the CLF launched changed once it was locked.

  Nominal Temp. Test Note
CLF Launch (OPO unlocked) 0.06 0.12 Changed with Waveplate
CLF Launch (OPO locked) 0.07 0.095  
RF6 Demod -10 0 This looked noisy in test, why?
CLF loop gain 0 -6  
LO loop gain -12 -15  
FC LSC -1.12 -0.566 In sqzparams.py
FC ASC -0.03 -0.015  
CLF ISS loop gain 23 17 From CLF AOM medm button
CLF ISS setpoint 0.347 0.694  

After changing the settings attached, ran scan_sqz_ang which only changed angle by 2deg. I don't see any extra noise at low frequeuncy. See attached, SQZ was a little worse at high frequency with the higher CLF. Not that the CLF RF6 was noisy, so maybe something was setup incorrectly.

To relock in the nominal settings, I had to realign ZM3 as the FC ASC had moved this away after the test when the SQZ was taken down, unsure why, maybe the way that I changed the ASC settings.

Images attached to this report
H1 SEI
ryan.short@LIGO.ORG - posted 10:49, Monday 22 September 2025 (87059)
HEPI Pump Trends - Monthly

FAMIS 37209, last checked in alog86426

Last month of trends seem to be looking as expected.

Images attached to this report
H1 PSL
ryan.short@LIGO.ORG - posted 09:40, Monday 22 September 2025 (87058)
PSL 10-Day Trends

FAMIS 31104

In general, things in the PSL are looking good after everything done following the power outage a couple weeks ago. There have been a few incursions in the PSL enclosure over the past week, the most consequential being last Tuesday's FSS path tuneup (alog86972). The biggest difference after that is the reading of the FSS TPD (a gauge of RefCav transmission) is now much lower as a result of recalibrating that PD, so this new reading of ~0.54 V can be considered our new "good" level.

ISS diffracted power has been on the rise for some reason; I'll keep an eye on this and check it when H1 is next out of lock. This could be a result of AMP2 output power having come back up slightly after the last incursion and things settling out.

Images attached to this report
H1 AOS (SQZ)
oli.patane@LIGO.ORG - posted 09:07, Monday 22 September 2025 (87056)
Overnight Out of Observing due to SQZ PMC

Overnight we had the ifo drop out of Observing briefly between 2205-09-22 08:23 and 08:27 UTC. This was due to the SQZ PMC PZT running out of range and unlocking. It was able to relock by itself and then get back to FDS

Non-image files attached to this report
H1 CDS
jonathan.hanks@LIGO.ORG - posted 08:32, Monday 22 September 2025 (87055)
Workstation/FOM window manager problems (windows stuck in position with no title bar)

We have had a few FOM and workstation problems where the window manager had died.  This leaves the windows with a border/titlebar/min max buttons/...  In this situation you are unable to move the windows and new windows pile up on top of each other.

This is fixable.

1. get to a terminal window

2. run xfwm4

    * This is the window manager that we us in the control room

    * With this running you should be able to manipulate windows again

3. log out and log back in to maek sure things have cleared up.

 

** Note you may also need to do a xfwm4 --relplace first, but that is not certain.

H1 General (Lockloss, SEI)
oli.patane@LIGO.ORG - posted 07:51, Monday 22 September 2025 - last comment - 13:49, Monday 22 September 2025(87053)
Lockloss

Lockloss at 2025-09-22 14:43 UTC after just over 4.5 hours locked due to earthquake. I took us to ASC Hi Gains once we were passing 700 on peakmon, and it fully transitioned over, but it was still too much movement for the ASC to handle

Comments related to this report
oli.patane@LIGO.ORG - 08:23, Monday 22 September 2025 (87054)

I've confirmed that the ASC Hi Gains had finished almost a minute before the lockloss.

Images attached to this comment
oli.patane@LIGO.ORG - 13:49, Monday 22 September 2025 (87064)

Back to NLN 16:05 UTC

Back to Observing 18:40 UTC

H1 General
oli.patane@LIGO.ORG - posted 07:35, Monday 22 September 2025 (87052)
Ops Day Shift Start

TITLE: 09/22 Day Shift: 1430-2330 UTC (0730-1630 PST), all times posted in UTC
STATE of H1: Observing at 34Mpc
OUTGOING OPERATOR: Ryan S
CURRENT ENVIRONMENT:
   SEI_ENV state: CALM
   Wind: 4mph Gusts, 2mph 3min avg
   Primary useism: 0.03 μm/s
   Secondary useism: 0.28 μm/s  
QUICK SUMMARY:  Observing at 153 Mpc and have been Locked for 4.5 hours.

H1 General
ryan.crouch@LIGO.ORG - posted 22:00, Sunday 21 September 2025 (87050)
OPS Friday eve shift summary

TITLE: 09/22 Eve Shift: 2330-0500 UTC (1630-2200 PST), all times posted in UTC
STATE of H1: Observing at 153Mpc
INCOMING OPERATOR: Ryan S
SHIFT SUMMARY: One lockloss with a long recovery, DRMI really didn't want to lock despite having pretty decent flashes after doing an alignment. The winds were moderate starting around 21:00 UTC, and were even worse from 00:00 to 01:00 UTC esp on YARM. We've been lock for a little over an hour.
LOG: No log.

H1 General (Lockloss)
ryan.crouch@LIGO.ORG - posted 16:52, Sunday 21 September 2025 - last comment - 20:59, Sunday 21 September 2025(87048)
21:51 UTC lockloss

21:51 UTC lockloss

Comments related to this report
ryan.crouch@LIGO.ORG - 17:33, Sunday 21 September 2025 (87049)

Winds are gusting over 30mph with a 3 min avg of 20mph. Relocking might take a little while. From windy.com (which uses ECMWF, European Centre for Medium-Range Weather Forecasts ) the winds are predicted to get a little worse in the next 2 or 3 hours then calm down around 4/5 UTC.

ryan.crouch@LIGO.ORG - 20:59, Sunday 21 September 2025 (87051)

03:57 UTC Observing

H1 General
ryan.crouch@LIGO.ORG - posted 16:12, Sunday 21 September 2025 (87047)
OPS Sunday EVE shift start

TITLE: 09/21 Eve Shift: 2330-0500 UTC (1630-2200 PST), all times posted in UTC
STATE of H1: Observing at 148Mpc
OUTGOING OPERATOR: Oli
CURRENT ENVIRONMENT:
    SEI_ENV state: CALM
    Wind: 30mph Gusts, 23mph 3min avg
    Primary useism: 0.04 μm/s
    Secondary useism: 0.28 μm/s
QUICK SUMMARY:

H1 CAL
oli.patane@LIGO.ORG - posted 12:12, Saturday 20 September 2025 - last comment - 09:14, Monday 22 September 2025(87038)
Calibration Measurement September 20, 2025

At the time of starting the calibration suite, we had been locked for 8.5 hours and so were fully thermalized.

Calibration monitor screen

Report (found at /ligo/groups/cal/H1/reports/20250920T183850Z/H1_calibration_report_20250920T183850Z.pdf

Broadband
2025-09-20 18:32:12 - 18:37:23 UTC
/ligo/groups/cal/H1/measurements/PCALY2DARM_BB/PCALY2DARM_BB_20250920T183212Z.xml

Simulines
2025-09-20 18:38:50 - 19:02:14 UTC
/ligo/groups/cal/H1/measurements/DARMOLG_SS/DARMOLG_SS_20250920T183850Z.hdf5
/ligo/groups/cal/H1/measurements/PCALY2DARM_SS/PCALY2DARM_SS_20250920T183850Z.hdf5
/ligo/groups/cal/H1/measurements/SUSETMX_L1_SS/SUSETMX_L1_SS_20250920T183850Z.hdf5
/ligo/groups/cal/H1/measurements/SUSETMX_L2_SS/SUSETMX_L2_SS_20250920T183850Z.hdf5
/ligo/groups/cal/H1/measurements/SUSETMX_L3_SS/SUSETMX_L3_SS_20250920T183850Z.hdf5

Images attached to this report
Non-image files attached to this report
Comments related to this report
elenna.capote@LIGO.ORG - 09:14, Monday 22 September 2025 (87057)CAL, SUS

Adding a comment here to note two things:

The thermalization adjustment of the SRCL offset appears to still be performing well according to the grafana page.

There is a 2% difference in TST actuation strength between the model that was pushed on 8/23 to the model created from this measurement. This is also reflected in kappa TST being about 1.02 after thermalization. This is likely due to charging. Tagging CAL and SUS.

Displaying reports 4621-4640 of 89208.Go to page Start 228 229 230 231 232 233 234 235 236 End