Displaying reports 5061-5080 of 83908.Go to page Start 250 251 252 253 254 255 256 257 258 End
Reports until 13:11, Monday 11 November 2024
H1 General (Lockloss)
anthony.sanchez@LIGO.ORG - posted 13:11, Monday 11 November 2024 - last comment - 14:12, Monday 11 November 2024(81198)
Midshift remprt

TITLE: 11/11 Day Shift: 1530-0030 UTC (0730-1630 PST), all times posted in UTC
STATE of H1: Corrective Maintenance
CURRENT ENVIRONMENT:
    SEI_ENV state: CALM
    Wind: 26mph Gusts, 19mph 3min avg
    Primary useism: 0.05 μm/s
    Secondary useism: 0.40 μm/s
QUICK SUMMARY:
Lockloss from NLN during comissioning tagged as windy: https://ldas-jobs.ligo-wa.caltech.edu/~lockloss/index.cgi?event=1415382893

Holding H1 in Down with the IMC locked but the ISS turned off to test if the ISS is the cause of the IMC glitches we have been seeing that breaks our locks.
The secondary Microseism is elevated and the Wind is gusting above 30 MPH, so it's a good time to try to test this.
 

Images attached to this report
Comments related to this report
anthony.sanchez@LIGO.ORG - 14:12, Monday 11 November 2024 (81199)PSL

IMC Lockloss @ 12:37:44 UTC even with the ISS turned off.

22:05:49 UTC the FSS Autolocker H1:PSL-FSS_AUTOLOCK_ON was turned off .

Images attached to this comment
H1 ISC
elenna.capote@LIGO.ORG - posted 12:30, Monday 11 November 2024 - last comment - 10:58, Tuesday 12 November 2024(81195)
Suspicious ETMX transition locklosses

We seem to be having lots of locklosses during the transition from ETMX/lownoise ESD ETMX guardian states. With Camilla's help, I looked through the lockloss tool to see if these are related to the IMC locklosses or not. "TRANSITION_FROM_ETMX" and "LOWNOISE_ESD_ETMX" are states 557 and 558 respectively.

For reference, transition from ETMX is the state where DARM control is shifted to IX and EY, and the ETMX bias voltage is ramped to our desired value. Then control is handed back over the EX. Then, in lownoise ESD, some low pass is engaged and the feedback to IX and EY is disengaged.

In total since the start of O4b (April 10), there have been 26 locklosses from "transition from ETMX"

From the start of O4b (April 10) to now, there have been 22 locklosses from "lownoise ESD ETMX"

Trending the microseismic channels, the microseism increases seems to correspond with the worsening of this lockloss rate for lownoise ESD ETMX. I think, when correcting for the IMC locklosses, the transition from ETMX lockloss rate is about the same. However, the lownoise ESD ETMX lockloss rate has increased significantly.

Comments related to this report
elenna.capote@LIGO.ORG - 15:39, Monday 11 November 2024 (81202)

Here is a look at what these locklosses actually look like.

I trended the various ETMX, ETMY and ITMX suspension channels during these transitions. The first two attachments here show a side by side set of scopes, with the left showing a successful transition from Nov 10, and the right showing a failed transition from Nov 9. It appears that in both cases, the ITMX L3 drive has a ~1 Hz oscillation that grows in magnitude until the transition. Both the good and bad times show a separate oscillation right at the transition. This occurs right at the end of state 557, so the locklosses within 1 or 2 seconds of state 558 likely are resulting from whatever the of the steps in state 557 do. The second screenshot zooms in to highlight that the successful transition has a different oscillation that rings down, whereas the unsuccessful transition fails right where this second ring up occurs.

I grabbed a quick trend of the microseism, and it looks like the ground motion approximately doubled around Sept 20 (third screenshot). I grabbed a couple of recent successful and unsuccessful transitions since Sept 20, and they all show similar behavior. A successful transition from Sept 19 (fourth attachment) does not show the first 1 Hz ring up, just the second fast ring down after the transition.

I tried to look back at a time before the DAC change at ETMX, but I am having trouble getting any data that isn't minute trend. I will keep trying for earlier times, but this already indicates an instability in this transition that our long ramp times are not avoiding.

Images attached to this comment
elenna.capote@LIGO.ORG - 16:51, Monday 11 November 2024 (81208)

Thanks to some help from Erik and Jonathan, I was able to trend raw data from Nov 2023 (hint: use nds2). Around Nov 8 2023, the microseism was elevated, ~ 300 counts average on the H1:ISI-GND_STS_ITMY_Z_BLRMS_100M_300M channel, compared to ~400 counts average this weekend. The attached scope compares the transition in Nov 8 2023 (left) versus this weekend Nov 10 (right). One major difference here is that we now have a new DARM offloading scheme. A year ago, it appears that this transition also involves some instability causing some oscillation in ETMX L3, but the instability now creates a larger disturbance that rings down in both the ITMX L3 and ETMX L3 channels.

Images attached to this comment
elenna.capote@LIGO.ORG - 18:11, Monday 11 November 2024 (81213)

Final thoughts for today:

  • the lockloss occurs within 1-2 seconds of when the ramp down of IX L3 and the ramp up of EX L3 occurs, so it seems like the issue here is within the L3 control
  • we have had instability issues with this transition back in March when we were commissioning it, which did include a 1 Hz instability
  • The growing oscillation before the transition is about 1 Hz, whereas the larger oscillation that can coincide with the lockloss is around 3 Hz.
  • Although the microseism is higher, this overall RMS on each suspension stage hasn't changed appreciably since April (see attachment). However, this plot compares NLN times. It's seems like the switchover itself is unstable, which is maybe too fast to compare
  • The switchover is between IX/EY control which appears to be on the "old" configuration and the EX "new" configuration, so even if each individual configuration is stable, maybe a combo of them is unstable.
Images attached to this comment
elenna.capote@LIGO.ORG - 10:58, Tuesday 12 November 2024 (81224)OpsInfo

Sheila and I looked a look at these plots again. It appears that the 3 Hz oscillation has the potential to saturate L3, which might be causing the lockloss. The ringup repeatedly occurs within the first two seconds of the gain ramp, which is set to a 10 second ramp. We decided to shorten this ramp to 2 seconds. I created a new variable on line 5377 in the ISC guardian called "etmx_ramp" and set that to 2. The ramps from the EY/IX to EX L3 control are now set to this value, as well as the timer. If this is bad, this ramp variable can be changed back.

H1 ISC
camilla.compton@LIGO.ORG - posted 12:26, Monday 11 November 2024 (81197)
No Significant Downstreasm Alignment shift after last IMC WFS Centering

Checked that there was no significant downstream alignment shift after the IMC WFS were centered on September 10th 80018. Checking because this because this was the same week the "IMC" locklosses started. 

Al downstream (IM4 TRANS and POPA/B)  QPD PIT/YAW values are the same within 0.05 (range -1 to 1) before and after the IMC WFS centering. Some NSUM change in IM4 TRANS, probably as this PD is clipped. Plot attached.

Images attached to this report
LHO VE
david.barker@LIGO.ORG - posted 11:51, Monday 11 November 2024 (81196)
Mon CP1 Fill

Mon Nov 11 10:17:12 2024 INFO: Fill completed in 17min 9secs

Jordan confirmed a good fill.

Images attached to this report
H1 PSL (ISC, Lockloss, OpsInfo)
camilla.compton@LIGO.ORG - posted 11:12, Monday 11 November 2024 - last comment - 15:06, Tuesday 19 November 2024(81193)
Overview of PSL Story so far

After discussions with control room team: Jason, Ryan S, Sheila, Tony, Vicky, Elenna, Camilla 

Conclusions: The NPRO glitches aren't new. Something changed to make us not be able to survive them as well in lock. The NRPO was swapped so isn't the issue. Looking the timing of these "IMC" locklosses, they are caused by something in the IMC or upstream 81155.

Tagging OpsInfo: Premade templates for looking at locklosses are in /opt/rtcds/userapps/release/sys/h1/templates/locklossplots/PSL_lockloss_search_fast_channels.yaml and will come up with command 'lockloss select' or 'lockloss show 1415370858'.

Comments related to this report
camilla.compton@LIGO.ORG - 15:45, Monday 18 November 2024 (81340)ISC
  • November 12th:
    • Took TFs 81247
    • Tightened loose ISS AOM RF cable 81247
    • Tested and characterized in-service TTFSS, SN LHO01: tuned notches and replaced a bad PA85 op amp 81247
  • November 13th:
    • IMC stayed locked without IFO 81262
    • FSS OLG and gain change 81254
    • IMC OLG and gain change 81259
  • Novmeber 14th:
    • PSL Beckhoff power cycle 81281
    • Replace 35MHz with Marconi: 81277
    • Tightened loose ISS AOM cable: 81280
  • Novmeber 18th:
    • LSC POP un-clipped 81329
    • Issues found with IMC locked checker in ISC_LOCK's READY 81336 (maybe keeping us in DOWN longer than needed)

Updated list of things that have been checked above and attache a plot where I've split the IMC only tagged locklosses (orange) from those tagged IMC and FSS_OSCIALTION (yellow). The non IMC ones (blue) are the normal lock losses and (mostly) only once we saw before September. 

Images attached to this comment
camilla.compton@LIGO.ORG - 15:06, Tuesday 19 November 2024 (81365)ISC
  • Novmeber 14th:
    • PMC OLG measured 81283
  • November 19th:
    • Scopes setup at PSL racks 81359
    • PMC+FSS only test shows glitches 81356
    • Reverted EX 28bit LIGO-DAC change back to 20-bit 81350
H1 ISC
elenna.capote@LIGO.ORG - posted 10:27, Monday 11 November 2024 - last comment - 16:28, Tuesday 12 November 2024(81194)
One CARM Sensor Injections

Sheila and I went out to the floor to plug in the cable to run frequency noise injections (AO2).

I switched us to REFL B (79037) only to run the injections. I first ran the frequency noise injection template. Then, I disenaged the 10 Hz pole and engaged the digital gain to run the ISS injections (low, medium, and high frequency). I was fiddling with the IMC WFS pitch injection template to get it to higher frequency for a jitter injection when we lost lock.

Next step is to at least use the intensity and frequency measurements to determine how the noises are coupling to DARM (would be nice to have jitter too, but we'll see).

Comments related to this report
victoriaa.xu@LIGO.ORG - 13:15, Tuesday 12 November 2024 (81226)

Commit 464b5256 in aligoNB git repo.

elenna.capote@LIGO.ORG - 16:28, Tuesday 12 November 2024 (81230)

These results show that above 3 kHz, some of the intensity noise couples through frequency noise. There is no measurable intensity noise coupling through frequency noise at mid or low frequency.

The frequency noise projection and coupling in this plot are divided by rt2 to account for the fact that frequency noise is measured on one sensor here, but usually is controlled on two REFL sensors. This may not be correct for high frequency (roughly above 4 kHz), where CARM is gain limited.

code lives in /ligo/gitcommon/NoiseBudget/simplepyNB/Laser_noise_projections.ipynb

Images attached to this comment
H1 General
anthony.sanchez@LIGO.ORG - posted 07:54, Monday 11 November 2024 (81188)
Monday Ops Day shift start

TITLE: 11/11 Day Shift: 1530-0030 UTC (0730-1630 PST), all times posted in UTC
STATE of H1: Observing at 161Mpc
OUTGOING OPERATOR: Ryan C
CURRENT ENVIRONMENT:
    SEI_ENV state: CALM
    Wind: 6mph Gusts, 4mph 3min avg
    Primary useism: 0.02 μm/s
    Secondary useism: 0.33 μm/s
QUICK SUMMARY:

Ryan C was called last night at 9:24 UTC.
When I walked in Sheila was in the Team speak chat, so maybe she was helping out with getting it locked first thing in the morning. 

NLN reached at 15:37  UTC
Observing reached at 15 :40 UTC


 

H1 General
ryan.crouch@LIGO.ORG - posted 01:43, Monday 11 November 2024 - last comment - 03:03, Monday 11 November 2024(81185)
H1 OPS OWL assistance

H1 called for assistance at 09:29 UTC after the initial alignment timer expired from the IMC unlocking an not relocking, we were in PREP_FOR_SRY. I took us to down and the IMC locked and I then went back into locking where DRMI locked very quickly and looked pretty decent.

Comments related to this report
ryan.crouch@LIGO.ORG - 02:18, Monday 11 November 2024 (81186)

lockloss at 10:07 UTC from LOWNOISE_ESD_ETMX, doesn't look like an IMC lockloss

Images attached to this comment
ryan.crouch@LIGO.ORG - 03:03, Monday 11 November 2024 (81187)

11:03 observing

LHO General
ibrahim.abouelfettouh@LIGO.ORG - posted 22:03, Sunday 10 November 2024 (81184)
OPS Eve Shift Summary

TITLE: 11/11 Eve Shift: 0030-0600 UTC (1630-2200 PST), all times posted in UTC
STATE of H1: Aligning
INCOMING OPERATOR: Ryan C
SHIFT SUMMARY:

IFO is LOCKING at CHECK_AS_SHUTTERS

Overall a smooth shift where we were locked for two thirds of the shift until the PSL glitch most likely took us down. Since then, the glitch has been happening without much gap for relocking. We've had gaps of 20 or so mins without glitching but that's been the maximum so far since LL. Lockloss alog 81181.

Other than that, we dropped out of OBSERVING very briefly due to a TCSY CO2 Laser SDF diff that fixed itself.

LOG:

None

H1 SEI (SEI)
ibrahim.abouelfettouh@LIGO.ORG - posted 21:36, Sunday 10 November 2024 (81183)
H1 ISI CPS Sensor Noise Spectra Check - Weekly FAMIS 26016

Closes FAMIS 26016. Last checked in alog 80912

Changes from last check:

Non-image files attached to this report
H1 PSL (Lockloss)
ibrahim.abouelfettouh@LIGO.ORG - posted 19:51, Sunday 10 November 2024 - last comment - 21:28, Sunday 10 November 2024(81181)
Lockloss 03:42 UTC

Lockloss seemingly PSL caused judging from IMC and ASC-A signals losing lock within 10ms (attached). About a 700ms after the glitching started, we lost lock. Interestingly, IMC is not glitching for minutes post-LL as it usually does, with IMC locking and staying locked in the new acquisition.

Images attached to this report
Comments related to this report
ibrahim.abouelfettouh@LIGO.ORG - 21:28, Sunday 10 November 2024 (81182)

Spoke way way (way) too soon. The glitch has been happening since the lockloss, which is much longer than usual. I've been staying in DOWN and attempting to lock if we pass 5 mins without glitching, which happened twice only to lose lock to it around DRMI or FIND_IR...

Watching the channels closely for when it stops so I can actually lock. The screenshot shows that the longest time without glitching since LL is that first 19 mins.

Images attached to this comment
H1 General
anthony.sanchez@LIGO.ORG - posted 16:16, Sunday 10 November 2024 (81180)
Sunday Ops Day Shift End

TITLE: 11/11 Day Shift: 1530-0030 UTC (0730-1630 PST), all times posted in UTC
STATE of H1: Observing at 157Mpc
INCOMING OPERATOR: Ibrahim
SHIFT SUMMARY:
The morning was a little shakey, but we persevered through the problematic IMC glitches to get to a lock by 22:35 UTC

LOG:                                                                                                                                                                                                                                                                                               

Start Time System Name Location Lazer_Haz Task Time End
21:41 SAF Laser LVEA YES LVEA is laser HAZARD 08:21
18:30 PEM Robert LVEA Yes Getting more spools of cable 18:39
18:48 PEM Robert CER No Checking cables 20:10
21:29 BBSS Ibrahim Staging Building N BBSS inventory 00:29
LHO General
ibrahim.abouelfettouh@LIGO.ORG - posted 16:08, Sunday 10 November 2024 (81179)
OPS Eve Shift Start

TITLE: 11/11 Eve Shift: 0030-0600 UTC (1630-2200 PST), all times posted in UTC
STATE of H1: Observing at 157Mpc
OUTGOING OPERATOR: Tony
CURRENT ENVIRONMENT:
    SEI_ENV state: CALM
    Wind: 7mph Gusts, 4mph 3min avg
    Primary useism: 0.03 μm/s
    Secondary useism: 0.37 μm/s
QUICK SUMMARY:

IFO is in NLN and OBSERVING as of 22:35 UTC

Recovered from a massive 6.8 EQ. Nothing else of note.

H1 General (Lockloss)
oli.patane@LIGO.ORG - posted 16:59, Tuesday 05 November 2024 - last comment - 09:21, Monday 11 November 2024(81084)
Lockloss

Lockloss @ 11/06 00:58UTC

Comments related to this report
oli.patane@LIGO.ORG - 17:09, Tuesday 05 November 2024 (81085)

This lockloss seems to have the AOM driver monitor glitching right before the lockloss(ndscope), similar to what I had noticed in the two toher locklosses from this past weekend(81037).

Images attached to this comment
oli.patane@LIGO.ORG - 19:51, Tuesday 05 November 2024 (81087)

03:45UTC Observing

camilla.compton@LIGO.ORG - 08:44, Monday 11 November 2024 (81189)Lockloss, PSL

In 81073 (Tuesday 05 November) Jason/Ryan S gave the ISS more range to stop it running out of range and going unstable. But on Tuesday evening, Oli saw this type of lockloss with again 81089. Not sure if we've seen it since then. 

The channel to check in the ~second before the lockloss is H1:PSL-ISS_AOM_DRIVER_MON_OUT_DQ, I added this to the lockloss trends shown by the 'lockloss' command line tool via /opt/rtcds/userapps/release/sys/h1/templates/locklossplots/psl_fss_imc.yaml

I checked all the "IMC" tagged locklosses since Wednesday 6th and didn't see any more of these.

jason.oberling@LIGO.ORG - 09:21, Monday 11 November 2024 (81190)

This happened before we fixed the NPRO mode hopping problem, which we did on Wednesday, Nov 6th.  Not seeing any more of these locklosses since lends credence to our suspicion that the ISS was not responsible for these locklosses, the NPRO mode hopping was (NPRO mode hops cause the power output from the PMC to drop, the ISS sees this drop and does its job by lowering the diffracted power %, once the diffracted power % hits 0 the ISS unlocks and/or goes unstable).

H1 General (ISC, Lockloss, PSL)
camilla.compton@LIGO.ORG - posted 16:34, Wednesday 30 October 2024 - last comment - 09:28, Monday 11 November 2024(80951)
IMC tagged Locklosses

Reran all O4b locklosses on the locklost tool with the most up to date code, which includes the "IMC" tag.

The locklooss tool tags "IMC" if the IMC looses lock within 50ms of the AS_A channel seeing the lockloss (example plots in 80561).
Note that we don't know that the IMC is causing the lockloss but we are sure that this lockloss is different from the typical lockloss where the IMC loses lock ~250ms after the IFO (seen by AS-port).
Vicky, Sheila and I did some trending this morning and found no conclusions of whats causing the locklosses, we checked that the fast shutter itself isn't causing the lockloss (via HAM6 SEI GS13's) and it seem like in the milliseconds of the lockloss, the AS power decreases and excess power goes to the REFL port.

I used the lockloss tool data since the emergency OFI vent (back online ~23rd August) until today and did some excel wizardry (attached) to make the two attached plots, showing the number of locklosses per day tagged with IMC and without tag IMC. I made this plots for just locklosses from Observing and all NLN locklosses (can include commissioning/maintenance times), including:

Images attached to this report
Non-image files attached to this report
Comments related to this report
camilla.compton@LIGO.ORG - 09:49, Thursday 31 October 2024 (80965)ISC, Lockloss

Attaching plots from zooming in on a few locklosses:

Time Tags Zoom Plot Wide Plot
2024-10-31 12:12:26.993164 UTC (IMC) OBSERVE IMC REFINED annotated plot plot
2024-10-30 12:16:33.504883 UTC (IMC) OBSERVE IMC REFINED annotated plot plot
2024-10-30 16:09:21.548828 UTC (Normal) OBSERVE REFINED OMC_DCPD N/A annotated plot

The 10-31 zoom plot notes the framerates of the channels: ASC, REFL and NPRO_PWR are 2kHz and GS13 is 4kHz, the others are 16kHz.

  • In the "NORMAL" lockloss (nearly 100% of locklosses since O4a and O4b before OFI vent):
    • The arm signals (ASC_AS_A/C) increase over 10's ms as the REFL signal decreases.
    • ~250ms later the PSL channels change and the IMC looses lock. 
  • In the "IMC" lockloss (25% of locklosses since OFI vent):
    • The arm signals (ASC_AS_A/C) suddenly (<0.5ms) decrease as the REFL signal increases.
    • At the same time the PSL signals change.
    • <10 ms later the IMC looses lock.
Images attached to this comment
sheila.dwyer@LIGO.ORG - 11:31, Thursday 31 October 2024 (80975)

Since September 18th we've had 21 locklosses from NLN tagged as FSS_OSCILLATION, of these 20 also had the IMC tag.   Since September 12th, we've had 49 locklosses from NLN tagged IMC, so roughly 40% of these IMC locklosses have the FSS oscillation tag, since the NPRO was swapped we don't have any tagged with FSS_OSCILLATION. 

(Reminder, the FSS_OSCILLATION tag is an old tag, intended for a different problem, but it tags times where the FSS fast mon goes above a treshold.)

camilla.compton@LIGO.ORG - 09:28, Monday 11 November 2024 (81191)

Updated plot attached of NLN locklosses tagged with and without the IMC tag. 

Images attached to this comment
Displaying reports 5061-5080 of 83908.Go to page Start 250 251 252 253 254 255 256 257 258 End