david.barker@LIGO.ORG - posted 10:23, Saturday 02 November 2024 (81011)
Sat CP1 Fill

Sat Nov 02 10:10:55 2024 INFO: Fill completed in 10min 51secs

 

Images attached to this report
H1 CDS
david.barker@LIGO.ORG - posted 10:21, Saturday 02 November 2024 - last comment - 10:28, Saturday 02 November 2024(81010)
New version of VACSTAT

Janos, Dave:

VACSTAT version 1.10

Following several recent false positive VACSTAT alarms due to noise in a single gauge (usually BSC3 PT132) we have made a change to the code to mitigate this.

The new alarm logic is:

The alarm system was modified to alert the vacuum team if the channel H1:CDS-VAC_STAT_GLITCH_NUM_GAUGES is 2 or greater.

My cell phone alarm will continue to sound on a single gauge trip, because tripped gauges are latched out from the sytem and we need to reset any false positives to restore the nominal functionality.

The new code was installed Friday afternoon (15:40 01nov2024 PDT).

Design reasoning:

In the event of an in-chamber gas release the local gauge will see a large signal. Gas migration to neighboring chambers will result in smaller signals there. Increasing their trip sensitivities will increase the chance of seeing a multi-chamber event.

 

Comments related to this report
david.barker@LIGO.ORG - 10:28, Saturday 02 November 2024 (81012)

A new enumerated PV has been added, H1:CDS-VAC_STAT_STATE.

It can have the following values

VACSTAT_STATES = {
    "MONITORING": 0,
    "SINGLE": 1,
    "MULTIPLE": 2,
}
 

MONITORING = nominal state.

SINGLE = one chamber has tripped, all the others have been set to their "sensitive" trip settings.

MULTIPLE = number of chambers tripped >= 2, alarms have been sent.

Images attached to this comment
H1 General (Lockloss)
oli.patane@LIGO.ORG - posted 10:14, Saturday 02 November 2024 - last comment - 11:08, Saturday 02 November 2024(81009)
Lockloss

Lockloss @ 11/02 17:13UTC after only 9 minutes locked

Comments related to this report
oli.patane@LIGO.ORG - 11:08, Saturday 02 November 2024 (81013)

18:08 UTC Observing

H1 General (Lockloss)
oli.patane@LIGO.ORG - posted 08:23, Saturday 02 November 2024 - last comment - 10:05, Saturday 02 November 2024(81007)
Lockloss

Lockloss @ 11/02 15:17 UTC after 4 hours locked

Comments related to this report
oli.patane@LIGO.ORG - 10:05, Saturday 02 November 2024 (81008)

17:05 UTC Observing

H1 General
oli.patane@LIGO.ORG - posted 07:39, Saturday 02 November 2024 (81006)
Ops Day Shift Start

TITLE: 11/02 Day Shift: 1430-2330 UTC (0730-1630 PST), all times posted in UTC
STATE of H1: Observing at 158Mpc
OUTGOING OPERATOR: TJ
CURRENT ENVIRONMENT:
    SEI_ENV state: CALM
    Wind: 21mph Gusts, 16mph 3min avg
    Primary useism: 0.03 μm/s
    Secondary useism: 0.26 μm/s
QUICK SUMMARY:

In Observing and have been Locked for 3hours 15mins. Secondary microseism is coming down and wind is just over 20mph

H1 General (SEI)
ryan.crouch@LIGO.ORG - posted 22:00, Friday 01 November 2024 (81001)
OPS Friday EVE shift summary

TITLE: 11/02 Eve Shift: 2330-0500 UTC (1630-2200 PST), all times posted in UTC
STATE of H1: Lock Acquisition
INCOMING OPERATOR: TJ
SHIFT SUMMARY: The IMC has been very unhappy and the FSS has been glitching frequently this shift. HLID picket fence seismometer has also been glitching out this afternoon (Tagging SEI), after the locklosses the IMC would lose it again and relock after reaching READY this kept happening this evening. We just locked PRMI as of 05:00 UTC.

The left display of the Operator WS is flickering, unplugging and plugged it back in fixes the issue but only for like an hour.

LOG: No log

Lock#1:

Images attached to this report
H1 General (Lockloss)
ryan.crouch@LIGO.ORG - posted 21:34, Friday 01 November 2024 (81005)
Lockloss 04:17 UTC (2:24 lock)

04:17 UTC, the IMC lost lock less than 100ms after ASC_AS_A, no IMC tag though and the FSS didn't really look glitchy.

Images attached to this report
H1 SEI
ryan.crouch@LIGO.ORG - posted 19:48, Friday 01 November 2024 (81004)
Quarterly HWWD bit FAMIS check

Closes FAMIS26509, last checked in alog79454. It looks as expected, the lack of switching in the recent past was the vent I believe.

Images attached to this report
H1 General (Lockloss)
ryan.crouch@LIGO.ORG - posted 18:01, Friday 01 November 2024 (81003)
Lockloss 00:53 UTC (31 minute lock)

00:53 UTC

IMC and ASC_AS lost it at the same time, looks like some kind of fast ringup in the FSS_FAST channel. FSS_OSCILLATION and IMC tag on the lockloss tool.

Images attached to this report
LHO General
thomas.shaffer@LIGO.ORG - posted 16:24, Friday 01 November 2024 (80989)
Ops Day Shift End

TITLE: 11/01 Day Shift: 1430-2330 UTC (0730-1630 PST), all times posted in UTC
STATE of H1: Lock acquisition
INCOMING OPERATOR: Ryan C
SHIFT SUMMARY: Ran a handful of tests today to try to narrow down further the FSS glitches that we've been seeing (80993, 80990 ). We recently started relocking with only minor changes, hopefully they will help.
LOG:

LVEA zone 1B has been slowly getting warmer over the past 2 days. Not a worry yet, but something we should keep an eye on.

 

Start Time System Name Location Lazer_Haz Task Time End
15:34 ISC Sheila LVEA n Unplug cable for IMC test 15:49
17:50 ISC/PSL Sheila, Vicky LVEA n FSS tfs 18:10
21:39 ISC/PSL Sheila, Marc LVEA n FSS meas. 21:40
21:40 SAF Ryan C LVEA N -> Y Laser HAZARD transition 21:49
21:40 ISC Keita LVEA YES HAM6 viewport camera housing PD 22:41
21:41 SAF Laser LVEA YES LVEA is laser HAZARD 08:21
Images attached to this report
H1 General
ryan.crouch@LIGO.ORG - posted 15:59, Friday 01 November 2024 - last comment - 17:26, Friday 01 November 2024(81000)
OPS Friday EVE shift start

TITLE: 11/01 Eve Shift: 2330-0500 UTC (1630-2200 PST), all times posted in UTC
STATE of H1: Lock Acquisition
OUTGOING OPERATOR: TJ
CURRENT ENVIRONMENT:
    SEI_ENV state: CALM
    Wind: 19mph Gusts, 10mph 3min avg
    Primary useism: 0.03 μm/s
    Secondary useism: 0.39 μm/s
QUICK SUMMARY:

Comments related to this report
ryan.crouch@LIGO.ORG - 17:26, Friday 01 November 2024 (81002)

00:25 UTC Observing

H1 AOS (DetChar)
kiet.pham@LIGO.ORG - posted 14:58, Friday 01 November 2024 (80997)
DQ Shift Report LHO: 14 Oct 2024 00:00 UTC to 20 Oct 2024 23:59 UTC

DQ Shift summary:

More daily details can be found at: https://wiki.ligo.org/DetChar/DataQuality/DQShiftLHO20241014

H1 ISC
sheila.dwyer@LIGO.ORG - posted 11:15, Friday 01 November 2024 - last comment - 15:47, Friday 01 November 2024(80993)
FSS OLG measurement

We measured the TTFSS OLG, I didn't save the data but will attach several photos here. There is a feature that looks like it could be unstable at 1.68MHz, there are about 3 untiy gain crossings around 500 kHz.  The FSS has a gain between the test points that mean that unity gain is at -10dB in this measurement. 

67253 Craig mentions that the FSS OLG was 350kHz, we'd need to reduce the gain by 3dB to get back to a 350 kHz ugf.

Comments related to this report
sheila.dwyer@LIGO.ORG - 11:17, Friday 01 November 2024 (80994)
Images attached to this comment
marc.pirello@LIGO.ORG - 14:43, Friday 01 November 2024 (80996)

Scans from the FSS after reducing gain.

Non-image files attached to this comment
sheila.dwyer@LIGO.ORG - 15:47, Friday 01 November 2024 (80998)

In Marc's files above the A one should be magnitude for 100kHz to a few MHz frequency span, B should be phase for that measurement.  C should be magntiude zoomed in on the 1.7MHz region, D should be phase for that measurement. 

Images attached to this comment
H1 General
thomas.shaffer@LIGO.ORG - posted 09:12, Friday 01 November 2024 - last comment - 15:59, Friday 01 November 2024(80990)
Pausing locking to run tests on laser glitching issue

We lost lock at some higher states in the relocking process due to the laser glitching* issue that we have been having. At this point we decided to pause locking for now to run some tests that were discussed during a meeting yesterday. The current plan is to hold at 2W with the ISS, FSS, and IMC locked. If this configuration is found to be unstable or we see excessive glitching still, then we will start to remove just the ISS or FSS, etc to narrow down the problem.

During this time, other, approved, light maintenance activities can take place.

 

*The issue may not be the laser itself, but I'm unsure what else to call this at the moment.

Comments related to this report
sheila.dwyer@LIGO.ORG - 10:18, Friday 01 November 2024 (80991)

We sat in this configuration from 15:34:37 UTC Nov 1 until the IMC lost lock at 16:45:34, 1 hour and 10 minutes.  The attached screenshot shows some channels at the time of the IMC lockloss, FSS fast mon and PC mon show some growing oscialltion until the time that the reference cavity transmission drops, the ISS sees a jump, and the IMC unlocks.

We've been sitting with the IMC in offline (MC2 is misaligned so the IMC won't flash), with the PMC, FSS and ISS locked since 17:09 UTC. 

 

Images attached to this comment
sheila.dwyer@LIGO.ORG - 15:59, Friday 01 November 2024 (80999)

Summary of today's tests:

  • IMC losses lock when it's locked by itself, with PMC, FSS, and ISS.  This shows up as a drop in power in the ref cavity transmission, similar to many of our locklosses tagged "IMC"
  • When we tried sitting with the FSS locked but the IMC unlocked, we still see similar drops in power in the ref cavity transmission, although we don't know if these would have unlocked the IMC or not, they seem quite similar to the ones that unlock it, so think that they might have.
  • We measured the FSS, and became concerned that the 1.7MHz peak crosses unity in a way that might make the FSS unstable 80993.  We discussed adjusting this notch but didn't make an attempt.
  • We lowered the FSS common gain by 3dB, which has been accepted in safe but not in observe.  With this gain lowered and the ISS off, we didn't see any glitches for 30 minutes (not long enough for a convincing test)
  • We decided to try relocking with the common gain lowered.
  • I removed the redistrbution of gain in the CARM servo so we will ride out earth quakes and microseism better over the weekend, as that change didn't seem to help: 80969
Images attached to this comment
H1 ISC
sheila.dwyer@LIGO.ORG - posted 10:18, Thursday 31 October 2024 - last comment - 13:30, Friday 01 November 2024(80969)
CARM gain redistributed again, now limiting range of frequency actuation

Yesterday we went back to the higher range CARM configuration, in which the fast/IMC locklosses first appeared  80938.  Overnight we had two observing locklosses tagged with the IMC, neither of which had glitches visible in the FSS fast mon channel, 1414411965 (1st attached screenshot), and 1414381791

This morning I changed the gains by 6 dB in the other direction, so we further limit the range available to the frequency actuator. (CARM sliders and ndscope) Our microseism is around 5um/second right now, slightly above the 90th percentile, but there was no wind and no earthquakes this morning.  At times the IMC splitmon was reaching -8V, it's range is +/- 10V so this is about as far as we can go in this direction, and might be kind of marginal.

We've since had one lockloss 1414426971, this is tagged as commissioning because we were in commissioning time at the moment, but no one was actively doing anything at the time so this wasn't caused by commissioners.  There was a glitch in the FSS fast mon for this lockloss, although it was below the threshold for the tag to be applied, and around the time of that glitch the drive to the ISS AOM becomes noisy.  We were not saturating the IMC splitmon at the time of the lockloss so that doesn't seem to be the cause.

Images attached to this report
Comments related to this report
sheila.dwyer@LIGO.ORG - 13:30, Friday 01 November 2024 (80995)

I've removed this, so now we will be back to the gains we've been with for the last several weeks, and most of O4.