Reports until 21:41, Tuesday 29 October 2024
H1 ISC (Lockloss)
ibrahim.abouelfettouh@LIGO.ORG - posted 21:41, Tuesday 29 October 2024 (80932)
Lockloss 00:39 UTC

Lockloss occured after our first NLN lock acquisition since the NPRO swap. Total time in NLN was 33 mins and the Lockloss Tool is giving an IMC flag.

X1 SUS
ibrahim.abouelfettouh@LIGO.ORG - posted 21:27, Tuesday 29 October 2024 (80931)
Raising BBSS Height to Compensate for TM Blade Height Decrease Drift Fix

After LHO's BBSS drift issues was "fixed" by lowering the blades by -4mm from nominal, we noticed that the PUM flags were low and somewhat too low even at their max adjustment. One of the ways to try and fix this was to increase the entire BBSS by 5mm. This maintains the Top Mass blade heights while raising the PUM flags into a centerable position for the PUM BOSEMs.

We increased BBSS Height Increased by 5mm, bringing the PUM flags back to nominal. Once this was done, we needed to move the Top Mass tablecloth upwards to compensate, so we did (by 5mm as well). Below is a table with the Mass-to-Structure gaps. Take note that the Top Mass Gap isn’t an absolute measurement since the tablecloth/structure it is measured from can also move.

Date

Dummy Test Mass Gap

PUM Gap (mm)

Top Mass Gap (mm)

Context

Nominal Dimensions (DWG)

25

17

19.90

Nominal - what the drawings in D1900628 tell us.

Feb 22 2024

25

14-15

17-18

First article build measurement (pre-drift investigation). 

Oct 17 2024

20.5

12.5

18.55

After “fixing” drift by lowring Top Mass blades -4mm BP (nominal blade position)

Oct 29 2024

25.5

17.5

21

After raising entire BBSS by raising Top Stage Blades +5mm

H1 PSL (OpsInfo)
jason.oberling@LIGO.ORG - posted 17:35, Tuesday 29 October 2024 (80929)
PSL NPRO Swap: It's Done (WP 12155)

J. Oberling, R. Short

Today was spent recovering the PSL stabilization systems after we got the amplifiers up and running yesterday.

PMC

We started with the PMC.  We did a quick alignment check at lower power (turned down with the High Power Attenuator (HPA) after Amp2) and all looked good here.  The power incident on the PMC was slowly increased to max, which we measured at 130.1W with our roving power meter.  The PMC ramp was activited and we say TEM00 flashes, so we hit the lock button and it locked without issue.  It only had ~100W in transmission so the alignment was tweaked with the picos and we also tweaked the pump diode currents for the amplifiers.  In the end we had 108.7W in transmission and 21.5W in reflection, and were running Amp1 at 9.0A and 8.8A and Amp2 at 9.1A (both power supplies).  The alignment onto the PMC locking PD was tweaked and we took a visibility measurement (correctly accounting for the 0.015V of dark voltage on this PD):

The PMC throughput was calculated at (Pout/Pin) 83.6%.  We also calibrated the PMC Trans and Refl PDs.  From the shape of the reflected spot we know there's more mode matching work to do with the PMC, but we have no shortage of power available to the IFO as is so we moved on to recovering the ISS.

ISS

We started by measuring the amount of power in the diffracted beam with the ISS OFF, so it should be ~3% of our maximum power.  We expected ~4.1W but measured 4.8W, so not quite right on the diffracted power % calibration.  The ISS AOM alignment was tweaked to max the power in the diffracted beam; this was 6.4W.  So we set about collecting the data needed to recalibrate the diffracted power % (change the Offset slider from 0 to 25 in steps of 1, recording the AOM voltage and power in the diffracted beam along the way).  The power into the ISS AOM was measured at ~135.5W.  To calibrate the diffracted power % we use the ISS AOM power in and the measured diffracted power to calculate the percentage of the PSL beam diffracted by the AOM, plot the AOM voltage vs this percentage, and fit a 2nd order polynomial to the resulting plot.  The plot is attached and the new polynomial is: 391.4x2 - 199.05x + 25.492.  We then set the Offset slider so that we had a "bank" of ~3% of our total Amp2 output for the ISS to use; the new Offset is 3.3, which gives us ~4.1W in the diffracted beam by default.  We looked at our overnight trends of Amp2 output and saw a total drift of ~1.5% of the laser power, so we set the ISS bank to be double that; if we find we need more power in the band the Offset can be changed.  We then adjusted the voltage on the ISS PDs to be near to 10V; PDA was reading 9.95V and PDB was reading 9.97V (PDB is currently our in-loop sensor and PDA is our out-of-loop sensor).  To finish, we tweaked the ISS QPD alignment.  Done with the ISS, we moved on to the FSS.

FSS

We started by trying to lock the FSS RefCav, and it locked on its own with zero issues.  The TPD was reading 0.88V so we did nothing to the FSS.  Should we need to tweak things up at a later date we will, but for now all appears healthy.

At this point we cleaned up the work space in the PSL enclosure and left, putting the enclosure into Science Mode once we had left.  On the outside we measured TFs for the PMC, ISS, and FSS, as well as took a look at the FSS crossover.

Transfer Functions

We started with the PMC.  We measured the UGF at ~1.6kHz with a phase margin of 59.9 degrees, see 2nd attachment.

Next was the ISS.  We measured the UGF at ~66.8kHz with a phase margin of 23.4 degrees, see 3rd attachment.  This was much higher than we had measured in right before the NPRO swap, so we dropped the inner loop ISS gain by 4dB (from 11dB to 7dB).  This put the UGF at ~41.9kHz with a phase margin of 41 degrees, much closer to where we were at before the NPRO swap (see 4th attachment).

Finally, the FSS.  We found the UGF around 420kHz, so we raised the Common Gain to 16dB (a change of 1dB) to put the UGF at ~519kHz with a phase margin of 65 degrees (see 5th attachment).  We then looked at the NPRO PZT/PSL EOM crossover (take a spectrum of the IN1 port on the TTFSS box).  We ended up lowering the Fast Gain from 7dB to 5dB to even out the crossover hump at ~20kHz, see final attachment.  We did notice a new peak at ~32.7kHz that could be the PZT resonance of the new NPRO.  We left this as-is for now, but if this becomes a problem we can tune the notch for the NPRO PZT to hopefully squash this peak; if that doesn't work we would have to pull the TTFSS and install a new notch.  This finished LVEA work so we went to the Control Room.

Control Room

Back in the Control Room Ryan did a remote alignment of the PMC and FSS RefCav.  Not much improvement on the RefCav, still have a TPD of ~0.88V with the IMC unlocked, but there was a good improvement in PMC Trans; the PMC is transmitting ~109.2W now.  We also updated the diffracted power % calibration and set the ISS AOM to diffract ~3% (tagging OpsInfo, this should be around 3% now).  We noticed the ISS AOM appears to be working harder with this NPRO, as the diffracted power % is moving more than with the previous NPRO.  We'll keep an eye on this over the coming days.

DIAG_MAIN was also complaining about the NPRO noise eater being out of range.  Looking at the channel it appeared the noise eater was off, even though we had it set in the PSL Beckhoff software to ON.  Toggling the software switch did not change anything, so I went out to the LVEA and physically switched the noise eater ON (it should be OFF at the power supply for the software switch to work).  This fixed the problem, so it appears there's something still not quite right with the remote diagnostics board in this NPRO, specifically with the remote noise eater switch.  So for future info, if we have to toggle the NPRO noise eater it has to be done at the NPRO power supply in the LVEA, not in the PSL Beckhoff software.

We went through and accepted all of the SDF diffs from the NPRO swap, and Ryan did a rotation stage calibration (he'll post these results as a comment).  At this point the NPRO swap was complete and the PSL is recovered and delivering light to the IFO again.  At the time of writing the IFO is locked at Nominal Low Noise and Observing once again.  This closes WP 12155.

Images attached to this report
H1 General (TCS)
thomas.shaffer@LIGO.ORG - posted 17:34, Tuesday 29 October 2024 - last comment - 10:14, Wednesday 30 October 2024(80930)
TCS SDFs and TEST_NOTIFY ignored by IFO node to get us to Observing

Reverted TCSY power head offset, was set to -17 reverted back to -15.

Reverted the channels in the screenshot related to ITMY HWS. I'm not entirely sure what these should be, but reverted for now should work until I can look into them further tomorrow.

I also added the TEST_NOTIFY node to the IFO node's exclude list. This wasn't an issue before because we have to specifically tell this node to check for new nodes, but we did a h1guardian1 reboot last week that pulled this node in.

Images attached to this report
Comments related to this report
camilla.compton@LIGO.ORG - 10:14, Wednesday 30 October 2024 (80940)TCS

The HWS_ORGIN_X/Y channels are used in the HWS spherical power calculation and should be centered on the IFO beam, checked in 80148. The other HWS_BEAM/CO2/RH_POS channels aren't used for anything currently, but we had ideas of using them to monitor the location of the center of the RH, IFO beam and CO2 beam.  They probably got reset tot he default values when the ITMY HWS computer crashed and IOC was restarted 80841.  For all of these, reverting was correct.

Changed the LASER POWER head offset when we re-calibrated it in 80812. It's such a small number that it doesn't really matter but reverted to old setpoint. Was accepted in safe, now accepted in observe too sdf.

Images attached to this comment
H1 General
oli.patane@LIGO.ORG - posted 16:31, Tuesday 29 October 2024 (80928)
Ops Day Shift End

TITLE: 10/29 Day Shift: 1430-2330 UTC (0730-1630 PST), all times posted in UTC
STATE of H1: Corrective Maintenance
INCOMING OPERATOR: Ibrahim
SHIFT SUMMARY: Currently trying to relock and at PRMI after a productive maintenance day and finishing up of PSL work.
LOG:

22:48 Started manual initial alignment
22:59 Manual initial alignment done, relocking                                                                                                                                                                                                                                                                                                                                                                                                             

Start Time System Name Location Lazer_Haz Task Time End
14:56 FAC Karen OPTLab/VacPrep n Tech clean 15:08
14:56 FAC Kim EX n Tech clean 16:40
15:09 FAC Karen LVEA n Restocking supplies 15:31
15:09 FAC Chris Mid-/End-Stations n FAMIS tasks 17:09
15:19 HWS TJ, Camilla EX n HWS collimater swap 16:43
15:32 FAC Karen EY n Tech clean 16:54
15:37   Christina OSB Receiving n Moving equipment 16:30
15:47 FAC Nelly HAM Shack n Tech clean 16:36
15:52 Tour Jackie MechRoom, LVEA n Tour 16:51
15:55 PSL RyanS, Jason PSL Encl y(local) PSL work 20:15
16:27   Mitchell LVEA n Checking stuff visually 18:02
16:45 VAC Gerardo FCES n Vac work 17:57
17:16   TJ LVEA n Looking for screws 17:24
17:32 FAC Kim LVEA n Tech clean 18:39
17:34 FAC Karen LVEA n Tech clean 18:32
17:39 FAC Chris LVEA n FAMIS 18:34
18:15 TCS TJ LVEA n Moving old CO2Y laser 18:25
18:29 - TJ LVEA n Sweep 18:51
18:34 FAC Chris   n Moving Forklift WT -> VPW -> Staging 19:21
19:01 VAC Gerardo, Jordan EX n Vacuum things 19:31
19:03 3IFO Tyler LVEA n 3IFO checks 19:10
20:53 Laser Vicky, Daniel LVEA, EX, EY n Adjusting temperature offsets for ALS, SQZ lasers 21:45
21:11 FIT Francisco, Neil EY n Running very far 22:01
22:14 PSL Jason LVEA n Switch NoiseEater switch 22:21
23:05   Vicky, Oli LVEA, CER n Turn lights off/put laptops back 23:10
LHO General
ibrahim.abouelfettouh@LIGO.ORG - posted 16:26, Tuesday 29 October 2024 (80927)
OPS Eve Shift Start

TITLE: 10/29 Eve Shift: 2330-0500 UTC (1630-2200 PST), all times posted in UTC
STATE of H1: Corrective Maintenance
OUTGOING OPERATOR: Oli
CURRENT ENVIRONMENT:
    SEI_ENV state: CALM
    Wind: 14mph Gusts, 9mph 3min avg
    Primary useism: 0.02 μm/s
    Secondary useism: 0.23 μm/s
QUICK SUMMARY:

IFO is LOCKING at PRMI

PSL Maintenance was ongoing throughout the day with PSL work finished (for now).

We've gone through a manual initial alignment and are now locking, which is apparently optimistic.

H1 PSL (ISC, SQZ)
jenne.driggers@LIGO.ORG - posted 14:18, Tuesday 29 October 2024 - last comment - 16:50, Tuesday 29 October 2024(80920)
Temp adjustment of Aux lasers (ALS, SQZ) to match new PSL NPRO freq

Daniel noted that the new NPRO is almost certainly at a different frequency than the previous one.  Also, since the PSL has been the most 'fussy' lately, we don't want to change it away from it's manufacturer-recommended settings (if we can help it), and instead want to change the other 3 lasers to match the new PSL frequency.

In the attachment, the top row is SQZ laser, the middle row is ALSX, and the bottom row is ALSY.  The leftmost column is the beatnote frequency between the given laser and the PSL, the middle column is the CrystalFrequency offset that we can provide, and the right column is the amplitude of the RF beatnote.

To figure out "where to go", Daniel put in a set of steps (eg, using ezcastep) to the CrystalFrequency channels. You can see that he started with the SQZ laser, but wasn't finding it by using a positive frequency offset.  He then found (using ALSY) that putting in a negative frequency offset of a little over 4 GHz (the CrystalFrequency numerical value is in units of MHz) brought the RFMON up, and the PLL loop was able to engage and bring the beat frequency to the right spot.  Once the RF mon started increasing, he Ctrl-C'd to stop the stepping of values.  Knowing that all 3 of these aux lasers at one point were matched to the PSL, he then set the SQZ laser and the ALSX laser to search around that -4 GHz value.  In order to have the PLL loops engage and not complain, Daniel set the H1:ALS-X_FIBR_LOCK_TEMPERATURECONTROLS_HIGH and _LOW settings for all 3 lasers to be a wide acceptable window (eg, +/- 6000 MHz, rather than a normal +/- 600 MHz).

Once all 3 lasers had their PLLs locked, Daniel and Vicky went out to each laser to adjust the nominal temp such that the CrystalFreq offset can be closer to zero.  My understanding of the procedure is that they will (with the PLL locked using the big offset) take a look at the current temp of the laser, according to the little LCD display on the front panel of the laser controller.  They will unlock the PLL and set the CrystalFrequency offset to 0, and then adjust the analog knob on the laser controller such that the temperature is back at the temp it was with the PLL locked with big offset.  They'll then allow the PLL to relock, hopefully not needing a very big CrystalFrequency offset.  While at each laser, they will also check that the laser is not in a mode hopping region with this new temperature.

After this is done, and once the PSL tune-ups are done for the day, we'll be able to start locking!

Images attached to this report
Comments related to this report
victoriaa.xu@LIGO.ORG - 14:54, Tuesday 29 October 2024 (80922)

Daniel, Vicky - adjusted temperatures on the ALS and SQZ lasers: 1) Noted the laser temp when TTFSS was running (> 4GHz off). This is the "nominal" new temperature. 2) Turned off TTFSS and set crystal frequency to 0 MHz. 3) Moved laser temperature knob to bring it to the "nominal" temperature. 4) Check TTFSS locks well. If needed, further adjust laser temperature knob to bring the crystal frequency is 0 MHz when TTFSS is running. 5) Check for mode-hopping.

To check for mode-hopping with laser temperature on the controller set at the new nominal, we turned off TTFSS and stepped the laser frequency +/- 200 (SQZ) or +/- 100 (ALS X/Y) MHz, then checked the beat note strength and frequencies made sense. All looked good at the new nominal laser temps. To make up the ~4 GHz laser frequency difference, we expected to change temperatures by like (-4.4 GHz / -3000 MHz/V) ~1.47 C, which is similar to what we did.

Laser temps changed as follows:

  • SQZ: 24.83 C --> 26.30 C
  • ALS X: 24.8 C --> 26.62 C
  • ALS Y: 28.59 C --> 30.05 C
victoriaa.xu@LIGO.ORG - 16:50, Tuesday 29 October 2024 (80926)

After the SQZ laser temperature was changed by ~4.4 GHz to meet the new PSL laser frequency, we had to change the OPO TEC temperature setpoint from 31.207 C --> 31.477 C. This is a bigger change than usual, but we had to adjust the temp to find and lock the OPO in dual-resonance (at first, there was almost no CLF6 beatnote, started out with RFMON around -40 when it should be around -11. By contrast the OPO locked fine yesterday).

At 31.477 C, we used the temperature to maximize NLG with seed light: amplified=0.133, de-amplified=0.0027, un-amplified=0.0087. NLG = amplified /unamplified ~ 15.25. Then H1:SQZ-CLF_REFL_RF6_DEMOD_RFMON = -10.9.

H1 ISC
elenna.capote@LIGO.ORG - posted 14:13, Tuesday 29 October 2024 - last comment - 16:07, Wednesday 30 October 2024(80918)
Tracking frequency noise coherence

Our frequency noise and contrast defect (measured at the OMC) are lower than they ever have been in O4 (contrast defect, frequency noise). As a part of trying to track down what may have caused this reduction, I tracked the coherence of DARM with the LSC REFL A RIN, using that as a witness to frequency noise, as it was used in OAF for online frequency noise cleaning in O4a (source: 72276 and poking around the OAF screens).

I tried to pick times that were a few hours into the lock to avoid thermalization confusion. I also used only observing data.

There are a couple ideas about what could have caused this improvement. A short list:

These are the times I used. All of these times were at the same 60 W input power from the PSL:

Dec 10 2023: O4a time, no WFS offset in use, EY ring heater set to 1 W (1386244818)

Apr 11 2024: O4b time, before the OFI problems, WFS offset in use, EY ring heater set to 1 W (1396950886)

Jul 10 2024: O4b time, just before OFI repair vent, WFS offset in use, EY ring heater set to 1 W (1404656647)

Sept 14 2024: O4b, after OFI repair, WFS offset in use, EY ring heater set to 1 W (1410432000)

Sept 20 2024: O4b, after OFI repair, WFS offset set OFF, EY ring heater set to 1 W (1410855190)

Oct 22 2024: O4b, after OFI repair, WFS offset set OFF, EY ring heater set to 1.1 W (1413635762)

Here are some notes for the comparison of these times:

All of these O4 times show less coherence than the O4a time. Based on this data, it seems like the WFS offset did have an impact on the frequency noise. It also seems like the various vents with output port changes could affect the frequency noise, but the overall beam alignment in the arms could have changed during the vent. For example, we did adjust the camera offsets/ADS gains during the vent commissioning times. The change in frequency noise during the OFI problems (between April and July) could have a similar source, since we had to change a lot of alignment during that time. I'm not sure if any arm alignment was significantly changed though. Finally, it seems like this small ring heater change had no effect on the frequency noise.

Images attached to this report
Comments related to this report
elenna.capote@LIGO.ORG - 13:03, Wednesday 30 October 2024 (80944)

Just a quick look at how the input jitter coherence has changed with these changes as well. For estimating input jitter, we generally use the IMC WFS A DC pitch and yaw channels, both for the noise budget and for jitter cleaning.

I used the exact same times as the freqeuency noise traces for ease, and I matched the colors too for easy comparison. Note: I used coherence with a channel that has no jitter subtraction to also avoid confusion.

This first plot compares the jitter coherence with DARM from all the times across the whole band in pitch and yaw. It's a bit hard to read. To make this easier, I'll break down the trace comparisons:

The most interesting point here (in my opinion) is that the improvement in frequency noise from the brown trace to the pink trace, that is, when we turned off the WFS offset, is opposite to the effect on the jitter noise. We've seen this before: improvements to frequency noise worsen jitter coupling and vice versa. I still don't understand that mechanism.

These are saved in the same template as the frequency noise plot: /ligo/home/elenna.capote/freq_noise_coherence_compare.xml

Images attached to this comment
elenna.capote@LIGO.ORG - 16:07, Wednesday 30 October 2024 (80950)

Daniel rightfully pointed out to me that REFL A RIN is a better measure of intensity noise than frequency noise. In the process of thinking about this, I realized that we found that PRCL had some offset present that increased DARM coherence to LSC REFL RIN. We first fixed this by applying a digital offset, and then Sheila rephased POP9 which had the same effect of reducing the coupling to REFL RIN and increasing power in the PRC. The digital offset was applied to PRCL from March 30 to May 6, and then again applied from Sept 16 until Sheila rephased POP 9 on Sept 23.

Since the PRCL offset/POP9 rephasing effects the coherence of DARM and REFL RIN, and to better ensure I am capturing frequency noise, I reran these measurements using coherence with the REFL SERVO CTRL channel.

Figure 1 We see similar improvement and worsening between O4a, Apr 12 O4b and Jun 10 O4b. Then, the three traces after the OFI vent show the same coherence, Figure 2. This indicates that the improvement between the brown (Sept 14) and pink (Sept 20) trace in the REFL RIN plot (original alog) is likely due to the changes in PRCL and not due to changes in frequency noise. In fact, the frequency noise coherence since the vent for these three times looks about the same.

This leads to the conclusion that the something about the OFI vent itself changed the frequency noise. We might be able to attribute it to an alignment change, but my sense is that whatever alignment change that occurred is small compared to the significant change in the output mode matching. I still don't full see how this then couples back to frequency noise, but it's worth some thinking and modeling.

Images attached to this comment
H1 SUS
oli.patane@LIGO.ORG - posted 14:03, Tuesday 29 October 2024 (80919)
plotallhlts_tfs_M1.m now shows cross-coupling plots

I have updated the plotallhlts_tfs_M1.m matlab script to allow the user to plot any potential cross-coupling. There is a newly-added boolean near the top called plotOffDiagonalTFs that can be set depending on whether you want to see the off-diagonal plots or not, and there is also a coupling matrix that can be changed depending on what coupling you want to see. The plots get appended to the end of the regular transfer function pdf file, allhltss_*_ALL_TFs.pdf. Attached is an example of how the cross-coupling plots are laid out. The script has been committed to svn as part of revision 12063.
 

Non-image files attached to this report
H1 General
thomas.shaffer@LIGO.ORG - posted 12:05, Tuesday 29 October 2024 - last comment - 16:15, Tuesday 29 October 2024(80917)
LVEA Swept

I preemptively swept the LVEA since it seems like the PSL work will complete soon. The only things of note are I ended up unplugging 5 unused extension chords.

The last remaining items are: PSL in Science mode, wifi off, LVEA lights off, PSL phone unplugged in 163.

Comments related to this report
oli.patane@LIGO.ORG - 16:15, Tuesday 29 October 2024 (80925)

The remaining checks from the LVEA sweep have been done.

H1 TCS
camilla.compton@LIGO.ORG - posted 11:57, Tuesday 29 October 2024 - last comment - 16:36, Tuesday 29 October 2024(80916)
Checking on CO2 ISS PDs

Looking at the CO2 ISS PD trends (qty 2 on each table labeled IN and OUT of loop), as the CIT CHETA setup that uses this PD is still getting confusing results (e.g. CIT#481). Each PD as an AC and DC mon output, from the DB9 of the PD preamp board D1201111.

Inially the DC signals look as expected, dropping to zero when laser is off (CO2X plot / CO2Y plot). CO2X stays within 1% when the laser is stable (CO2X plot). Though the CO2Y plots looks worse, only staying within 5% when the laser is stable (CO2Y plot).

If you pay attention to the ~hour  region once the laser is first turned on in both lasers (worse in CO2Y, see plot) the ISS PDs show power signal varying much more than the CO2 power head PD does. I don't understand why that would be, but this could explain the issues we've seen at CIT where the laser is always ina less stable state as is fan cooled rather than water cooled.

CO2Y_IN shipped to CIT in 80883.

Images attached to this report
Comments related to this report
camilla.compton@LIGO.ORG - 16:36, Tuesday 29 October 2024 (80924)

After suggestion from Keita, I have added trends of the thermal QPD NSUMs, which also shows this 9 minute oscillation but on a much smaller scale (less than 1% wobble). Plot here

The laser head reported power is in-loop (i.e. it's output is stabilized via the laser PZT), So it makes sense that it's very flat. There seems to be not much in this feedback loop, as laser power set point a PZT set point and a 0.5Hz integrator. Also the signal seems to go straight to the chiller with a ~1 hour integrator, I'm not sure if this really makes sense, but it seems to work. 

I'm still unsure why the ISS QPDs see such a big change at the start of turn on. To check if the PDs or Laser warming up cause this, I turned the CO2Y laser off then quickly (~5 seconds) on again.  This seemed to decrease the time of wobbles, plot attached. 

Images attached to this comment
LHO VE
david.barker@LIGO.ORG - posted 10:38, Tuesday 29 October 2024 (80915)
Tue CP1 fill

Tue Oct 29 10:08:04 2024 INFO: Fill completed in 8min 0secs

Gerardo confirmed a good fill curbside.

Images attached to this report
H1 CDS
david.barker@LIGO.ORG - posted 08:48, Tuesday 29 October 2024 - last comment - 10:37, Tuesday 29 October 2024(80913)
Fire pump running, test alarms and reporting

Eric is running the fire pumps this morning for maintenance. This is a good opportunity to test CDS reporting and alarms. Attached MEDM shows CDS Overview with a red fire pumps button, it opens the FMCS overview (also shown). I let the first three cell phone alarm texts to proceed and then bypassed this alarm for the remainder of this morning.

Bypass will expire:
Tue Oct 29 08:41:08 PM PDT 2024
For channel(s):
    H0:FMC-CS_FIRE_PUMP_1
    H0:FMC-CS_FIRE_PUMP_2
 

Images attached to this report
Comments related to this report
david.barker@LIGO.ORG - 10:37, Tuesday 29 October 2024 (80914)

Bypass has been removed

H1 SEI (SEI)
corey.gray@LIGO.ORG - posted 08:21, Tuesday 29 October 2024 (80912)
H1 ISI CPS Noise Spectra Check - Weekly (Famis 26015)

FAMIS Link:  26015

Only CPS channels which look higher at high frequencies (see attached) would be the following (which have been like this on the order of weeks):

  1. ITMx St1 V1
  2. ITMy St1 V2
  3. ETMy St1 H2
Non-image files attached to this report
H1 PSL
sheila.dwyer@LIGO.ORG - posted 11:22, Monday 28 October 2024 - last comment - 11:20, Thursday 31 October 2024(80902)
comarison of new and old PSL glitches

Continuing on from Jenne's observation that there are still glitches in the new NPRO, I've tried to make a plot we can use to compare the glitch rate in the new and old NPROs, using the NPRO_PWR channel instead of the FSS channel which isn't available for the new NPRO. 

I've used a 3 hour stretch of observing time for the old NPRO, and a three hour stretch before the time when Jenne made a plot in 80837.  The ISS is not on for the new NPRO time, which is probably why the intensity is flcutuating and making it harder to see the small steps in power that are the glitches we are looking for.  In the second panel, I've plotted the data high passed with a 0.05 Hz butterworth, this helps to show the glitches, although not perfectly (in either case).  Based on this, the glitches look to be happening at a roughly similar rate, although somewhat less with the new NPRO.

This script in in sheila.dwyer/DutyCycle)4/dutycycleplots/PSL_glitches.py

Images attached to this report
Comments related to this report
brian.lantz@LIGO.ORG - 16:04, Monday 28 October 2024 (80906)
sheila.dwyer@LIGO.ORG - 11:42, Monday 28 October 2024 (80903)

Attaching another plot, showing that comparing our old NPRO to LLO during an observing stretch that started at midnight UTC time on Oct7th, LLO has no similar glitches.

Images attached to this comment
sheila.dwyer@LIGO.ORG - 14:26, Tuesday 29 October 2024 (80921)

Here's the same plot, but using a time from last night when the PSL environmental controls were off.  There are still gltiches, but fewer.

Images attached to this comment
victoriaa.xu@LIGO.ORG - 14:23, Wednesday 30 October 2024 (80947)

These plot tiles show runs of Sheila's code looking for PSL power glitches on several days before / after the suspect date around Sept 12.

There's not a clear correlation between the glitches and locklosses. While maybe there's more glitches after Sept 12 (bottom row), the glitches don't consistently correlate with locklosses? Sept 14 is a good example of this: lots of glitches, the IFO stays locked through many of them.

2nd plot here shows overnight again with the swapped new laser. There are still glitches (though potentially less). 

Images attached to this comment
Non-image files attached to this comment
sheila.dwyer@LIGO.ORG - 15:21, Wednesday 30 October 2024 (80948)

The PSL-PWR_NPRO_OUT_DQ channel seems to not be connected at LLO, which explains why the comparison plot a few comments above makes it look like L1 PSL is so much quieter than H1.

victoriaa.xu@LIGO.ORG - 11:20, Thursday 31 October 2024 (80973)

Adding screenshot of the NPRO power glitches over the past day. There are still glitches with the new laser -- not all glitches correspond to locklosses, but some do.

Images attached to this comment
Displaying reports 5361-5380 of 83944.Go to page Start 265 266 267 268 269 270 271 272 273 End