TJ, Camilla WP# 12121.
Current CO2Y laser: 20510-20816D which was re-gassed in 2016 and installed in October 2022 65264.
To prepare for the CO2Y laser swap next week:
Tue Oct 15 10:11:38 2024 INFO: Fill completed in 11min 34secs
TCs looking good again.
13:01 UTC lockloss from NLN (12:40 lock)
~1000 Hz oscillation in DARM, violins 1st harmonic area. There was a small DARM wiggle 200ms then a much larger DARM wiggle 100ms before the lockloss, IMC lost it the usual 1/4 sec after ASC-AS_A.
J. Kissel WP 12140 Per investigations described in WP 12140, I've installed elements for driving the H1 ISI HAM2 ISI in the H1 SUS PR3 suspension point's Euler basis into the ISI's H1:ISI-HAM2_SUSPOINT_EUL2CART matrix. The elements had been pre-calculated using the math from T1100617, and pulled from pre-saved collection of these matrices in /opt/rtcds/userapps/release/isc/common/projections/ISI2SUS_projection_file.mat To install, I ran the following code in matlab from a control room work station, >> addpath /ligo/svncommon/SeiSVN/seismic/Common/MatlabTools/ % this adds fill_matrix_values.m to the path, needed below >> cd /opt/rtcds/userapps/release/isc/common/projections/ >> load ISI2SUS_projection_file.mat >> drvmatrx = ISI2SUSprojections.h1.pr3.EUL2CART >> drvmatrx = 1 -0.0112 0 -0.0115 -1.0243 -0.1768 0.0112 1 0 1.0243 -0.0115 -0.3308 0 0 0 0 0 1 0 0 1 0.1805 0.3288 0 0 0 0 1 -0.0112 0 0 0 0 0.0112 1 0 >> fill_matrix_values('H1:ISI-HAM2_SUSPOINT_EUL2CART',drvmatrx) % this actually installs the coefficients into EPICs. These channels are *NOT* monitored in SDF. However, to make sure they stick, I've accepted the values in both the safe and OBSERVE safe snap files.
TITLE: 10/15 Day Shift: 1430-2330 UTC (0730-1630 PST), all times posted in UTC
STATE of H1: Aligning
OUTGOING OPERATOR: TJ
CURRENT ENVIRONMENT:
SEI_ENV state: CALM
Wind: 4mph Gusts, 3mph 3min avg
Primary useism: 0.03 μm/s
Secondary useism: 0.38 μm/s
QUICK SUMMARY:
When I Arrived ISC_LOCK was in Inintial_alignment, Init_Align was in Locking Green Arms, and ALSY arm has no light on it.
Last lockloss was 2024-10-15_13:01:37Z ISC_LOCK NOMINAL_LOW_NOISE -> LOCKLOSS
TJ Said he got called by H1 Manny just before 7:30.
I will be running Oli's script as described in Alog 76606 to save all slider values before the CDS team does their DAQ Restart thing.
Output of Oli's script:
anthony.sanchez@cdsws29: python3 update_sus_safesnap.py
No optics or groups entered. -h or --help to display opt-ions.
anthony.sanchez@cdsws29: python3 update_sus_safesnap.py -h
usage: update_sus_safesnap [-h] [-p] [-o [OPTICS ...]]
Reads the current OPTICALIGN_{P,Y}_OFFSET values and uses those to overwrite
the OPTICALIGN_{P,Y}_OFFSET values in the burt files linked from their
respective safe.snap files.
options:
-h, --help show this help message and exit
-p, --print-only Use -p or --print-only to only print the beforeand
after values without updating the values saved in
safe.snap. (default: False)
-o [OPTICS ...], --optics [OPTICS ...]
Type the names of optic groups (ex. itm) or individual
optic names (ex. pr2), with spaces in between. Case
does not matter.
OptGroup | Optics OptGroup | Optics
itm ITMX etm ETMX
ITMY ETMY
bs BS tms TMSX
TMSY
rm RM1
RM2 pr PRM
PR2
im IM1 PR3
IM2
IM3 mc MC1
IM4 MC2
MC3
sr SRM
SR2 ifo_out OFI
SR3 (om if w/o OFI) OMC
OM1
fc FC1 OM2
FC2 OM3
zm_in OPO zm_out ZM4
ZM1 ZM5
ZM1 ZM6
ZM3
(default: none)
anthony.sanchez@cdsws29: python3 update_sus_safesnap.py -o itm bs rm im sr fc zm_in etm tms pr mc ifo_out zm_out
Running $(USERAPPS)/isc/h1/guardian/update_sus_safesnap.py
Updating and printing out saved OPTICALIGN_{P,Y}_OFFSET values from safe.snap vs current values for these optics:
ITMX ITMY BS RM1 RM2 IM1 IM2 IM3 IM4 SRM SR2 SR3 FC1 FC2 OPO ZM1 ZM2 ZM3 ETMX ETMY TMSX TMSY PRM PR2 PR3 MC1 MC2 MC3 OFI OMC OM1 OM2 OM3 ZM4 ZM5 ZM6
Traceback (most recent call last):
File "/opt/rtcds/userapps/trunk/isc/h1/scripts/update_sus_safesnap.py", line 318, in <module>
old_new = replace_offsets(opt_dicts(optics), print_only=print_only)
File "/opt/rtcds/userapps/trunk/isc/h1/scripts/update_sus_safesnap.py", line 201, in replace_offsets
cur_vals.append(ezca[pchanname])
File "/var/opt/conda/base/envs/cds/lib/python3.10/site-packages/ezca/ezca.py", line 304, in __getitem__
return self.read(channel)
File "/var/opt/conda/base/envs/cds/lib/python3.10/site-packages/ezca/ezca.py", line 294, in read
pv = self.connect(channel)
File "/var/opt/conda/base/envs/cds/lib/python3.10/site-packages/ezca/ezca.py", line 272, in connect
raise EzcaConnectError("Could not connect to channel (timeout=%ds): %s" % (self._timeout, name))
ezca.errors.EzcaConnectError: Could not connect to channel (timeout=2s): H1:SUS-OFI_M1_OPTICALIGN_P_OFFSET
anthony.sanchez@cdsws29: python3 update_sus_safesnap.py -o zm_out
Running $(USERAPPS)/isc/h1/guardian/update_sus_safesnap.py
Updating and printing out saved OPTICALIGN_{P,Y}_OFFSET values from safe.snap vs current values for these optics:
ZM4 ZM5 ZM6
SUS-ZM4_M1_OPTICALIGN_P_OFFSET
Old Saved: -7.92342523045482380439e+02
New Saved: -772.2246009467159
SUS-ZM4_M1_OPTICALIGN_Y_OFFSET
Old Saved: -9.85740674423158566242e+02
New Saved: -981.3613025567112
SUS-ZM5_M1_OPTICALIGN_P_OFFSET
Old Saved: -1.15000000000000000000e+02
New Saved: -115.0
SUS-ZM5_M1_OPTICALIGN_Y_OFFSET
Old Saved: -4.60000000000000000000e+02
New Saved: -460.0
SUS-ZM6_M1_OPTICALIGN_P_OFFSET
Old Saved: 1.39848934620929139783e+03
New Saved: 1408.6829424213722
SUS-ZM6_M1_OPTICALIGN_Y_OFFSET
Old Saved: -2.83802124439147348767e+02
New Saved: -260.05899996129443
anthony.sanchez@cdsws29: python3 update_sus_safesnap.py -o ifo_out
Running $(USERAPPS)/isc/h1/guardian/update_sus_safesnap.py
Updating and printing out saved OPTICALIGN_{P,Y}_OFFSET values from safe.snap vs current values for these optics:
OFI OMC OM1 OM2 OM3
Traceback (most recent call last):
File "/opt/rtcds/userapps/trunk/isc/h1/scripts/update_sus_safesnap.py", line 318, in <module>
old_new = replace_offsets(opt_dicts(optics), print_only=print_only)
File "/opt/rtcds/userapps/trunk/isc/h1/scripts/update_sus_safesnap.py", line 201, in replace_offsets
cur_vals.append(ezca[pchanname])
File "/var/opt/conda/base/envs/cds/lib/python3.10/site-packages/ezca/ezca.py", line 304, in __getitem__
return self.read(channel)
File "/var/opt/conda/base/envs/cds/lib/python3.10/site-packages/ezca/ezca.py", line 294, in read
pv = self.connect(channel)
File "/var/opt/conda/base/envs/cds/lib/python3.10/site-packages/ezca/ezca.py", line 272, in connect
raise EzcaConnectError("Could not connect to channel (timeout=%ds): %s" % (self._timeout, name))
ezca.errors.EzcaConnectError: Could not connect to channel (timeout=2s): H1:SUS-OFI_M1_OPTICALIGN_P_OFFSET
anthony.sanchez@cdsws29:
That error to my update_safe_snap script shouldn't happen again - I had put the OFI as an option in there for overwriting the OPTICALIGN offset settings, but it turns out that the OFI doesn't have opticalign offsets! Neither does the OPO, so I've removed both of those from the code.
It seems to now be working correctly (but it's tricky to test) so hopefully there are no more issues with running it.
TITLE: 10/15 Eve Shift: 2330-0500 UTC (1630-2200 PST), all times posted in UTC
STATE of H1: Observing at 155Mpc
INCOMING OPERATOR: TJ
SHIFT SUMMARY: Very quiet shift tonight. Once H1 relocked at the start of the shift, we've been observing with steady range.
H1 has now been locked for almost 5 hours.
Lockloss @ 23:29 UTC - link to lockloss tool
No obvious cause, but looks to be some ETMX L3 motion right before the lockloss.
H1 back to observing at 00:23 UTC. Fully automatic relock.
TITLE: 10/14 Day Shift: 1430-2330 UTC (0730-1630 PST), all times posted in UTC
STATE of H1: Observing at 156Mpc
INCOMING OPERATOR: Ryan S
SHIFT SUMMARY: We've been locked for almost 8 hours, locked almost the whole shift.
LOG:
Start Time | System | Name | Location | Lazer_Haz | Task | Time End |
---|---|---|---|---|---|---|
15:26 | FAC | Karen, Kim | FCES | N | Tech clean, out at 15:46 | 17:59 |
19:25 | FAC | Karen | MidY | N | Tech clean | 20:20 |
TITLE: 10/14 Eve Shift: 2330-0500 UTC (1630-2200 PST), all times posted in UTC
STATE of H1: Observing at 155Mpc
OUTGOING OPERATOR: Ryan C
CURRENT ENVIRONMENT:
SEI_ENV state: USEISM
Wind: 16mph Gusts, 13mph 3min avg
Primary useism: 0.04 μm/s
Secondary useism: 0.50 μm/s
QUICK SUMMARY: H1 has been locked for over 7 hours and observing for the past 2 hours.
The well pump has been cycled twice during our tank cleaning work. The pump is currently operating for a manual cycle time of 20 minutes, at which point we will identify its level and record it for future reference. For those interested, the well pump takes ~40 seconds to begin filling after being cycled on. C. Soike E. Otterman T. Guidry
25 minutes of pump runtime adds roughly 48" of water to the well tank.
Sheila, Camilla
17:23 - 1745 Turned off SQZ IFO ASC and ran SCAN _SQZ_ALIGNMENT (changed ZMs by ~20urad max plot but BLRMs worse) and then SCAN_SQZANG (changed by 4deg, BLRMS improved but still worse than original). DTT comparing: shows that the AS42 SQZ IFO ASC did better than guardian SCAN_SQZ alignment and angle.
17:50:30 - 18:30:30 UTC - Took No Squeezing time. IFO had been in NLN for 2h10m. Checked NLG = 13.8 (0.12133/0.008785), following 76542. OPO temperature was already at best.
Went back to FDS with ASC and ran SCAN_SQZANG. After the first FDS data set, we turned off ASC.
FDS Data set:
State | Time (UTC) | Start time (gps) | Angle | DTT Ref |
Notes |
FDS ASC on | 17:16 | 1 | |||
FDS SCAN_ALIGN | 17:49 | 2 | (ASC off). SQZ worse than with AS42: plot | ||
No SQZ | 17:50:30 - 18:00:30 (10min) | 1412963448 | N/A | 0 | |
FDS | 18:06:00 - 18:12:00 (6min) | 1412964378 | 182.4 | 3 | |
Glitch 2 minutes in, looked simular to FDS | |||||
Mid SQZ + | 18:26:00 - 18:32:00 (6min) | 1412965578 | 216.6 | 4 | Aimed for No SQZ level at 2kHz |
A SQZ | 18:36:00 - 18:42:00 (6min) | 1412966178 | (-)105.6 | 5 | |
A SQZ +10deg | 18:42:15 - 18:48:15 (6min) | 1412966553 | (-)115.1 | 6 | |
A SQZ -10deg | 18:48:30 - 18:54:30 (6min) | 1412966928 | (-)95.2 | 7 | |
Mid SQZ - | 18:56:00 - 19:02:00 (6min) | 1412967378 | 136.9 | 8 | Aimed for No SQZ level at 2kHz |
FDS +10deg | 19:03:30 - 19:09:30 (6min) | 1412967828 | 192.8 | 9 | |
FDS -10deg | 19:10:00 - 19:16:00 (6min) | 1412968218 | 172.0 | 10 | |
FDS (repeat, ASC off)
|
19:16:30 - 19:22:30 (6min)
|
|
182.4
|
11
|
Slightly worse than ref3
1h10 later with ASC off
|
Plot attached showing ASQZ and Mid sqz trends and FDS trends. Saved as camilla.compton/Documents/sqz/templates/dtt/14Oct2024_SQZ_FDS_ASQZ/SQZ.xml.
Then did scan SQZ ang (adjusted 182.4 to 183.9) and turned on ASC in FDS. Then turned off ASC and went to FIS (un-managed form ISC_LOCK). Tweaked SQZ angle as it wasn't optimized at high freq.
FDS Data set:
State | Time (UTC) | Start time (gps) | Angle | DTT Ref |
Notes |
FIS | 19:40:30 - 18:46:30 (6min) | 1412970048 | 193.4 | 3 | |
Mid SQZ + | 19:47:30 - 18:53:30 (6min) | 1412970468 | 218.0 | 4 |
Aimed for No SQZ level at 2kHz
(SEI state changed to useism at 19:52 UTC)
|
A SQZ | 19:56:00 - 20:02:00 (6min) | 1412970978 | (-)103.3 | 5 | |
A SQZ +10deg | 20:02:30 - 20:08:30 (6min) | 1412971368 | (-)113.8 | 6 | |
A SQZ -10deg | 20:09:00 - 20:15:00 (6min) | 1412971758 | (-)93.8 | 7 | |
Mid SQZ - | 20:16:30- 20:22:30 (6min) | 1412972208 | 147.0 | 8 | Aimed for No SQZ level at 2kHz |
FIS +10deg | 20:24:30- 20:30:30 (6min) | 1412972688 | 203.8 | 9 | |
N/A | Got distracted and changed angle too soon | ||||
FIS -10deg | 20:35:45- 20:41:45 (6min) | 1412973363 | 183.9 | 10 | |
FIS (repeat) | 20:42:00- 20:48:00 (6min) | 1412973738 | 193.4 | 11 | V. simular to ref 3. Maybe slightly better |
Plot attached showing FIS ASQZ and Mid sqz trends and FDS trends. Saved as camilla.compton/Documents/sqz/templates/dtt/14Oct2024_SQZ_FIS_ASQZ/SQZ.xml.
No SQZ 20:49:00UTC to 20:51:00UTC while we went back to FDS, I started it at 185deg and ran SCAN_SQZANG, angle adjusted to 189deg. Back to Observing at 20:57UTC.
FAMIS 31055
The PSL has been taken down a few times in the past week as part of the glitching investigations, and this is seen clearly on several trends. Also, since the NPRO controller was swapped 5 days ago but the potentiometers on the daughter board were not adjusted on the one swapped in (alog80566), some of the readbacks for the NPRO channels are reporting inaccurate values, namely the laser diode powers. The controller is planned to be swapped back to the original tomorrow so these readbacks will be fixed.
Other item of note is that every time the PMC was unlocked last week, it seems to have relocked with a slightly higher reflected power and corresponding lower transmitted power (see stabilization trends). Looking at the PMC REFL camera image, there could be something to gain from an alignment tweak into the PMC, so I'll try that tomorrow during maintenance and see if there's any improvement.
17:22 UTC We started comissioning, starting a little late today due to the IFO not being fully locked and thermalized.
Mon Oct 14 10:12:33 2024 INFO: Fill completed in 12min 29secs
Travis confirmed a good fill curbside.
In the past few weeks, a number OPO temperature changes have been made while the detector was in observing mode (per the relevant instructions). These changes have been highly successful at increasing the range, particularly the most recent couple of OPO changes. However, this type of rapid improvement in the spectrum can create challenges when measuring the spectrum of the data in downstream data analysis pipelines (similar to how the sudden turn-on of the line subtraction was problematic). When the OPO adjustment has created significant changes to the spectrum, the time periods during the transition should be CAT1 vetoed (tagging Detchar-request).
As an example of these transitions, I've included a range timeseries and a daily spectrogram with the transition time indicated. I also have included a before/after spectrum comparison showing the broadband improvement at high frequency.
To mitigate the impact on data analysis pipelines, future transitions should either be made while briefly out of observing or tracked by Detchar for CAT1 vetoes.
-Brice, Sheila, Camilla
We are looking to see if there are any aux channels that are affected by certain types of locklosses. Understanding if a threshold is reached in the last few seconds prior to a lockloss can help determine the type of lockloss, which channels are affected more than others, as well as
We have gathered a list of lockloss times (using https://ldas-jobs.ligo-wa.caltech.edu/~lockloss/index.cgi) with:
(issue: the plots for the first 3 lockloss types wouldn't upload to this aLog. Created a dcc for them: G2401806)
We wrote a python code to pull the data of various auxilliary channels 15 seconds before a lockloss. Graphs for each channel are created, a plot for each lockloss time are stacked on each of the graphs, and the graphs are saved to a png file. All the graphs have been shifted so that the time of lockloss is at t=0.
Histograms for each channel are created that compare the maximum displacement from zero for each lockloss time. There are also a stacked histogram based on 12 quiet microseism times (all taken from between 4.12.24 0900-0930 UTC). The histrograms are created using only the last second of data before lockloss, are normalized by dividing by the numbe rof lockloss times, and saved to a seperate pnd file from the plots.
These channels are provided via a list inside the python file and can be easily adjusted to fit a user's needs. We used the following channels:
After talking with Camilla and Sheila, I adjusted the histogram plots. I excluded the last 0.1 sec before lockloss from the analysis. This is due to (in the original post plots) the H1:ASC-AS_A_NSUM_OUT_DQ channel have most of the last second (blue) histogram at a value of 1.3x10^5. Indicating that the last second of data is capturing the lockloss causing a runawawy in the channels. I also combined the ground motion locklosses (EQ, Windy, and microseism) into one set of plots (45 locklosses) and left the only observe (and Refined) tagged locklosses as another set of plots (15 locklosses). Both groups of plots have 2 stacked histograms for each channel:
Take notice of the histogram for the H1:ASC-DC2_P_IN1_DQ channel for the ground motion locklosses. In the last second before lockloss (blue), we can see a bimodal distribution with the right groupling centered around 0.10. The numbers above the blue bars is the percentage of the counts in that bin: about 33.33% is in the grouping around 0.10. This is in contrast to the distribution for the observe, refined locklosses where the entire (blue) distribution is under 0.02. This could indicate a threshold could be placed on this channel for lockloss tagging. More analysis will be required before that (I am going to next look at times without locklosses for comparison).
I started looking at the DC2 channel and the REFL_B channel, to see if there is a threshold in REFL_B that can be put for a new lockloss tag. I plotted the last eight seconds before lockloss for the various lockloss times. This time I split up the times into different graphs based on if the DC2 max displacement from zero in the last second before lockloss was above 0.06 (based on the histogram in previous comment): Greater = the max displacement is greater than 0.06, Less = the max displacement is less than 0.06. However, I discovered that some of the locklosses that are above 0.06 for the DC2 channel, are failing the logic test in the code: getting considered as having a max displacement less than 0.06 and getting plotted on the lower plots. I wonder if this is also happening in the histograms, but this would only mean that we are underestimating the number of locklosses above the threshold. This could be suppressing possible bimodal distributions for other histograms as well. (Looking into debugging this)
I split the locklosses into 5groups of 8 and 1 group of 5 to make it easier to distinghuish between the lines in the plots.
Based on the plots, I think a threshold for H1:ASC-REFL_B_DC_PIT_OUT_DQ would be 0.06 in the last 3 seconds prior to lockloss
Fixed the logic issue for splitting the plots into pass/fail the threshold of 0.06 as seen in the plot.
The histograms were unaffected by the issue.
Added code to the gitLab