In the past few weeks, a number OPO temperature changes have been made while the detector was in observing mode (per the relevant instructions). These changes have been highly successful at increasing the range, particularly the most recent couple of OPO changes. However, this type of rapid improvement in the spectrum can create challenges when measuring the spectrum of the data in downstream data analysis pipelines (similar to how the sudden turn-on of the line subtraction was problematic). When the OPO adjustment has created significant changes to the spectrum, the time periods during the transition should be CAT1 vetoed (tagging Detchar-request).
As an example of these transitions, I've included a range timeseries and a daily spectrogram with the transition time indicated. I also have included a before/after spectrum comparison showing the broadband improvement at high frequency.
To mitigate the impact on data analysis pipelines, future transitions should either be made while briefly out of observing or tracked by Detchar for CAT1 vetoes.
I've wrote a small script to revert ZM sliders after a SCAN_ALIGNMENT is run (SQZ_MANAGER state 105) incase we don't like it. It does a rough search for when this state was last run in the past day (it probably can be reduced but I needed a larger range for testing) using minute trends. From this time it then does a more narrow second trend to get more accurate state boundary times (did this for speed of nds2 calls), then it just takes the slider values of ZM{4,6} from a minute before the most recent SCAN_ALIGNMENT started and caputs them.
You can change the lookback time by changing the "days" and "hours" variables at the top of the script which lives at /opt/rtcds/userapps/release/sqz/h1/scripts/revert_sqz_align.py
Overall the finidings were similar to the previous days, with a few exceptions. On Monday there was ground motion reported around 7:00. On Tuesday, there was also earthquake ground motion, and a slight increase in glitch rate around the hours of 1:00-3:00, and at 12:00 and 15:00. On Wednesday, there were no significant changes to report. On Thursday, there was rotational wind motion around hours 1-5:00 and glitch rate increase around hours 6:00-8:00. Also there was a decrease in the Detchar Fscan lines to around 400, which was less than previous days. On Friday, there were no significant changes to report. Fscans lines increased back to the normal range. On Saturday, there was earthquake motion around 19:00. On Sunday, there was a slight increase in the lock/strain/sensitivity around 16:00.
TITLE: 10/14 Day Shift: 1430-2330 UTC (0730-1630 PST), all times posted in UTC
STATE of H1: Lock Acquisition
OUTGOING OPERATOR: Oli
CURRENT ENVIRONMENT:
SEI_ENV state: CALM
Wind: 4mph Gusts, 3mph 3min avg
Primary useism: 0.03 μm/s
Secondary useism: 0.42 μm/s
QUICK SUMMARY:
2 high state locklosses on this reaquisition, TRANSITION_FROM_ETMX at 13:55 UTC and a LOWNOISE_ESD_ETMX at 14:44 UTC
DARM coherence low range check
Over the summer, Sam, Robert, and I investigated several peaks in DARM, including one at ~35.4 Hz and a peak that oscillates between 30-40 Hz. The 35.4 Hz peak was found to couple strongly at HAM1 and HAM6 (see alog 79546). Shut-offs of the office area air handler and the main chillers showed that the peak decreases when these systems are shut off, though it doesn't disappear completely. See Figure 1 and Figure 2 with office area air handler shut offs at 19:33:00-19:38:30 and 19:43:00-19:55:00 (alog 79888), and Figure 3 for main chiller shut offs (alog 73941). Note that there is also a fainter peak about 0.2 Hz above the 35.4 Hz peak as seen in Figure 4 but it is unclear if it also decreases when the HVAC is shut off.
The oscillating 30-40 Hz peak tends to be near 40 Hz at the beginning and end of the UTC day and drops to near 30 Hz in the middle of the day as seen in Figure 5. It often appears sinusoidal as seen in Figure 6 but sometimes has a more random appearance as in Figure 7. It is seen in microphones and magnetometers as well, and first appeared at least as early as 6 June 2024. Its source has yet to be identified.
These peaks were dicussed in a presentation at the end of our summer fellowship as well as in a DetChar call, now posted on the DCC: LIGO-G2402140.
TITLE: 10/14 Eve Shift: 2330-0500 UTC (1630-2200 PST), all times posted in UTC
STATE of H1: Observing at 158Mpc
INCOMING OPERATOR: Oli
SHIFT SUMMARY: Pretty quiet evening with just one lockloss followed by an automatic relock. Range has been keeping fairly steady this lock.
H1 has been locked and observing for just over 4 hours.
Lockloss @ 23:53 UTC - link to lockloss tool
No obvious cause. Maybe a small ETMX glitch before the lockloss, but otherwise I haven't noticed anything else.
H1 back to observing at 00:48 UTC. Fully automatic relock.
TITLE: 10/13 Day Shift: 1430-2330 UTC (0730-1630 PST), all times posted in UTC
STATE of H1: Observing at 154Mpc
INCOMING OPERATOR: Ryan S
SHIFT SUMMARY: We've been locked for just over 2 hours, 3 locklosses today fairly automated relocks.
LOG: No log.
TITLE: 10/13 Eve Shift: 2330-0500 UTC (1630-2200 PST), all times posted in UTC
STATE of H1: Observing at 154Mpc
OUTGOING OPERATOR: Ryan C
CURRENT ENVIRONMENT:
SEI_ENV state: CALM
Wind: 4mph Gusts, 2mph 3min avg
Primary useism: 0.03 μm/s
Secondary useism: 0.45 μm/s
QUICK SUMMARY: H1 has been locked and observing for 1.5 hours.
Laser Status:
NPRO output power is 1.829W (nominal ~2W)
AMP1 output power is 64.44W (nominal ~70W)
AMP2 output power is 137.5W (nominal 135-140W)
NPRO watchdog is GREEN
AMP1 watchdog is GREEN
AMP2 watchdog is GREEN
PDWD watchdog is GREEN
PMC:
It has been locked 3 days, 3 hr 9 minutes
Reflected power = 24.22W
Transmitted power = 101.8W
PowerSum = 126.0W
FSS:
It has been locked for 0 days 0 hr and 21 min
TPD[V] = 0.7953V
ISS:
The diffracted power is around 2.1%
Last saturation event was 0 days 0 hours and 22 minutes ago
Possible Issues:
AMP1 power is low
PMC reflected power is high
EX saturation then lockoss
RyanC, Camilla, Vicky
I noticed that the SQZer wasn't locking from NUC33 this morning when I first adjusted the OPO temperature. The OPO kept dropping when the FC trys to lock IR, there was a SQZ ISS saturated notification on DIAG_MAIN. I looked through the alogs and wikis on this. I investigated the checks that RyanS went through last night in alog80639 to no avail, I also tried setting FC1 & 2 back to their spots from the last time we locked the SQZer using OSEMs which didn't help either. I ended up contacting Camilla, where we:
H1:SQZ-FC_TRANS_C_LF_OUTPUT
improved form 75 to 120.def PMC_PZT_OK(): return 5 < ezca['SQZ-PMC_PZT_VOLTS'] < 95
and everything worked fine. Simular issue to what Ryan Short had in https://alog.ligo-wa.caltech.edu/aLOG/index.php?callRep=80490Sun Oct 13 10:12:24 2024 INFO: Fill completed in 12min 21secs
Overall the fill looks good, but the TCs are not showing their normal winter profile and are getting very close to the -200C limit. Friday 11oct2024 plot shown for comparison.
Also TC-B again looks significantly different from TC-A.
TITLE: 10/12 Day Shift: 1430-2330 UTC (0730-1630 PST), all times posted in UTC
STATE of H1: Microseism, Lock Aquisition
INCOMING OPERATOR: Ryan S
SHIFT SUMMARY: Second saturday tours today, we've been struggling to relock following the EQ due to the elevated secondary microseism.
TITLE: 10/13 Day Shift: 1430-2330 UTC (0730-1630 PST), all times posted in UTC
STATE of H1: Lock Acquisition
OUTGOING OPERATOR: Oli
CURRENT ENVIRONMENT:
SEI_ENV state: CALM
Wind: 6mph Gusts, 5mph 3min avg
Primary useism: 0.04 μm/s
Secondary useism: 0.42 μm/s
QUICK SUMMARY:
For the last 2 long lock stretches the range has slowly degraded, as the range decreases the BLRMs rise, it also looks like ZMs 4&6 are drifting which is expected.
There's still an issue with the FC locking, as soon as we go to IR_FOUND in SQZ_FC we lose lock, turning on VCO controls? Camilla and I have been trying things for a little bit to no luck, now we're going to tag in Sheila and or Vicky for more help. I'm seeing if we can get to FREQ_IND SQZing.