TITLE: 10/06 Eve Shift: 2330-0500 UTC (1630-2200 PST), all times posted in UTC
STATE of H1: Lock Aquisition
OUTGOING OPERATOR: Corey
CURRENT ENVIRONMENT:
SEI_ENV state: CALM
Wind: 11mph Gusts, 7mph 3min avg
Primary useism: 0.02 μm/s
Secondary useism: 0.17 μm/s
QUICK SUMMARY:
Back to Observing at 00:48 UTC
TITLE: 10/06 Day Shift: 1430-2330 UTC (0730-1630 PST), all times posted in UTC
STATE of H1: Lock Acquisition
INCOMING OPERATOR: Ryan C
SHIFT SUMMARY:
Observing for almost half of the shift. With one EQ lockloss in the afternoon which we are recovering from now.
LOG:
Smooth sailing this morning with H1 locked most of the time, but it just lost lock after a 4hr lock (managed to make it through which took down L1 30min ago). Other than that, environmentals are decent. Off to make lunch.
About Last Night: 737 - 1401utc (1237am-701am PDT)
Only looking at locklosses at ISC LOCK states from 500 and above (i.e. with ASC Full IFO); a lot of the other locklosses were at early states (and quite a bit have the FSS Oscillation tag)
Sun Oct 06 08:09:41 2024 INFO: Fill completed in 9min 37secs
TITLE: 10/06 Day Shift: 1430-2330 UTC (0730-1630 PST), all times posted in UTC
STATE of H1: Lock Acquisition
OUTGOING OPERATOR: Ryan S
CURRENT ENVIRONMENT:
SEI_ENV state: CALM
Wind: 4mph Gusts, 3mph 3min avg
Primary useism: 0.02 μm/s
Secondary useism: 0.14 μm/s
QUICK SUMMARY:
H1 currently at ENGAGE ASC (after a lockloss from Observing for a 51min lock). Environmal conditions about identical to yesterday. (although there looks to be an EQ about an 1hr ago (close to recent lockloss [but also don't see on 1412258495.71875]...perhaps M5.2 from Vanuatu region).
Additional Note: The 3hr downtime had one lockloss which happened 10min after getting to NLN and H1 Manager had not taken H1 to Observing which is a bit odd. After that the next 2hr locking time had lots of Green Arm locklosses (9 in total), but it eventually made it back to Observing.
H1 called for assistance at 08:39 UTC after reaching NLN successfully but being unable to start observing due to an issue with SQZ. I found the issue was that the PMC was consistently locking between 11-12V, and because of the lower bound of 15V in the check recently added to unlock and relock the PMC when outside of a comfortable range (see alog80371), SQZ_MANAGER would repeatedly unlock the PMC once it reached FDS_READY_IFO. Since the PMC seemed happy at this 11-12V point, for now I've changed the lower threshold for the PMC PZT check from 15V to 10V (line 73). SQZ_MANAGER injected squeezing just fine after that, and H1 started observing at 08:55 UTC.
TITLE: 10/06 Eve Shift: 2330-0500 UTC (1630-2200 PST), all times posted in UTC
STATE of H1: Observing at 153Mpc
INCOMING OPERATOR: Ryan S
SHIFT SUMMARY: 1 lockloss with an automated relock, we've been locked for a little over an hour.
LOG: No log.
01:45 UTC I adjusted the OPO temperature a 2nd time as the high frequency looked bad on NUC33.
01:53 UTC Superevent S241006k
02:35 UTC lockloss (12:44 lock)
03:45 UTC Observing
TITLE: 10/05 Day Shift: 1430-2330 UTC (0730-1630 PST), all times posted in UTC
STATE of H1: Observing at 152Mpc
INCOMING OPERATOR: Ryan C
SHIFT SUMMARY:
Much different shift compared to yesterday with H1 locked the entirety of the shift! (vs only 1 or 2 hrs during yesterday's shift!). Ran the Saturday calibration. Ryan C touched up the OPO temperature while H1 was Observing.
LOG:
TITLE: 10/05 Eve Shift: 2330-0500 UTC (1630-2200 PST), all times posted in UTC
STATE of H1: Observing at 152Mpc
OUTGOING OPERATOR: Corey
CURRENT ENVIRONMENT:
SEI_ENV state: CALM
Wind: 12mph Gusts, 7mph 3min avg
Primary useism: 0.02 μm/s
Secondary useism: 0.15 μm/s
QUICK SUMMARY:
About Last Night: 523 - 1235utc (1023pm-535am PDT)
Only looking at correlations of locklosses with IMC locking and at a high enough ISC LOCK state to have ASC engaged.
Much different shift from yesterday!
H1 was locked before my shift started and is currently at 5.75hrs. Ran the Saturday calibration. Environmentally, winds are much calmer than yesterday and useism continues its slow crawl downward.
Measurement NOTES:
Editor's Note: In an attempt at documenting recent SUS Fiber Puller activities and share overall status of work of the Advanced LIGO Fiber Puller Lab located in the LSB building here at LHO, have had requests to post our notes/summaries (which in the last few years had been relegated to notes in logbooks, email chains, hearsay, etc.) in the LHO Logbook and tagging the ALOG section as "X1" with a Primary Task of "SUS".
Summary Of The Last 2-Years
(Alphabetical list of people who have helped/been involved: C.Gray, J.Kissel R.McCarthy J.Oberling, T.Sadecki, R.Savage, TJ Shaffer, R.Short, B.Weaver)
Upgrade To 200W Laser (Fall 2022)
Until recently, the last batch of Pulled Fibers were pulled in Fall 2022. At this time, the Fiber Puller started having issues related to the laser (f100 CO2 laser by Synrad; 100W and 10,600um)--this laser was well over a dozen years old and at the end of its operational life. Higher power lasers had already been purchased for the Fiber Puller about 5-years ago in preparation for an upgrade and a possible need to pull thicker diameter silica fibers for heavier suspensions. Because of this, it was decided to upgrade the Fiber Puller with one of these 200W lasers (f201 CO2 laser by Synrad; 200W and 10,600um). The 200W laser is bigger than the previous laser, and because of this, the back of this laser hangs off the edge of the optics table, but Rick made a nice breadboard which offers a platform to support the back of this laser (see image1). Cabinets and furniture were removed along the wall to allow extra space to for walking around this area of the lab.
After RyanS and I installed the new laser & re-did the chiller plumbing, we moved on to aligning the laser into the Fiber Puller. Since alignment work was next, we took this opportunity to swap in new upper & lower conical mirrors in the Fiber Puller (Travis ordered these a while ago.).
Alignment Work Begins (2023-2024)
Then, with the help of Karl Toland's thesis (Chapter 2), we started Fiber Puller alignment. This included Mechanical checks of the Fiber Puller which looked mostly OK; it was noticed there is a slight tilt forward of the tower. We decided to not change this. The periscope which points the beam into the Fiber Puller was reconfigured to allow its translation stages (namely the horizontal one) to have better adjustability for pointing into the Fiber Puller--previously the horizontal translation stage only moved forward and back which did not allow for horizontal translations of the beam into the Fiber Puller (this only required us to rotate the translation stage 90deg).
After this it was all optical alignment work, and this proved to be non-trivial. Additionally, one of the gold mirrors was burned. This mirror had a glass substrate, so it was replaced with a gold mirror with a copper substrate (also took this opportunity to replace several dirty input gold mirrors).
Then there was several months of no progress with alignment. Eventually Travis & Jason checked out the status of alignment. And in Aug 2024, Jason was able to give us a decent looking beam on our stock and after almost 2-years, fibers were finally pulled again!
Return To Fiber Pulling! ...For A Little While.
Between Aug 2-20th, six fibers were pulled (4 passes & 2 fails). At this point, while preparing to pull another fiber, one of the 1/8" ID tubing to the shutter burst on Aug 20, 2024.
NOTE: Here I will paste in the email summary I sent to the group on Sept 26th.
Recovery From The Plumbing Failure On Aug 20, 2024
[start of email]
Summary:
After the 1/8" chilling hose burst (8/20), weeks were spent with recovery and buying new plumbing hardware. There is now better hosing for the shutter + beam bender (mirror mount) and most of the fittings have been replaced with push-to-connects (excepted for barbed fitting of the beam bender (see image 6)). We have been running the chiller w/ new plumbing since 9/17/2024.
For the plumbing fix above, this was done in-situ without removing the shutter or mirror mount with the hopes of preserving the alignment, but first looks at alignment by myself and Jason at separate times did see an alignment change on our fiber stock target. On Sept 25th, we were both able to work on the Fiber Puller, and Jason was able to get us a decent alignment back, we pulled our first fiber since the 8/20 chiller plumbing link---and this fiber also passed on 9/26!
PLUMBING (see image 5):
The backstory is years ago a water-cooled shutter & mirror mount were installed (1/8" ID plumbing using a mix of push-to-connect & barbed fittings) for the Fiber Puller. The water-cooled shutter & mirror mount were added in series to the laser (which has 1/2"OD tubing) via an aluminum manifold. During the 100W to 200W laser swap by RyanS and I, we discovered everything downstream of the laser (1/8" ID stuff) had been clogged (most likely for years) from the manifold downstream to the shutter + mirror mount. This led to us replacing all lines, cleaning the manifold, and starting to use OptiShield with the chiller water with hopes of preventing any corrosion clogs. This worked for a while during the upgrade and even through six NEW fibers pulled in August, but after the 6th fiber there was a huge burst in the tubing at the shutter.
This led to repair work, with a few issues/notes observed:
ALIGNMENT Once Again:
For all of the plumbing work above, I opted to do it "in situ" by not "touching" the shutter or beam bender (I did not remove them from the beam path and only connected/disconnected their tubing)---this was all in the hopes of not changing the alignment---we had a nice alignment which produced decent fibers in August!
Although I attempted to be careful with all of the plumbing work above, first checks by both myself and Jason later showed we were off a little when we looked at the fiber stock target with the red beam.
[On Sept 25, 2024], Jason and I were both able to work together in the fiber lab. Here are some of the notes I took while Jason did his alignment magic!
Alignment Attempt #1:
Red beam alignment
Jason went through alignment touch-up via the periscope mirrors. He was quickly able to get a decent beam on the fiber stock target. At this point, he checked to see how this beam looked with the alignment irises which have been in place all the while (between the periscope and Fiber Puller). After aligning beam to the irises, he once again had a decent beam on the fiber stock. In both cases, there was a "hot spot" noted on the "back" side of the fiber stock.
CO2 beam alignment
With the main CO2 beam on a new fiber stock, we needed to turn the power up to about 55-60% on the laser to be able to see the beam via the cameras in the Labview app. With the cameras, I tweaked the (periscope mirrors) to get a better alignment (which allowed us to lower the power to about 50%). Jason had a try at tweaking alignment via the cameras (I believe this was his first chance getting to do this—especially since the side camera was better-focused on our stock back in August).
We were able to optimize a little more, but it still looked not great (see image 7). I thought it might have looked like what we had when we were pulling fibers in August, but we could clearly see it wasn't great. There was an angle on the fiber stock and the rear camera could clearly see the angle even more. I mentioned we could probably pull a fiber, but we'd definitely have to increase the laser power. We did not pull a fiber however. We broke for lunch with hopes at more checks in the afternoon.
Alignment Attempt #2 With Mechanical Offset Check Between Top & Bottom Clamp Translation Stages:
Translation Stages:
Thinking there was still something amiss mechanically, Jason wanted to check the Top & Bottom Clamp Translation Stages. We do this using a special tool to set the Upper translation stage and the Lower translation stage (the latter we have not touched for a while).
Jason went through several iterations of making small adjustments to both the upper and lower translation stages (see image 8). On one of the final adjustments, he intentionally overshot the upper translation stages. This was to hopefully help us later (it did!).
Tower:
NOTE: At this point, Jason continued with mechanical checks and we looked at the Tower with a bubble level. There is an observable tilt forward of the tower albeit small. (this is mentioned above) Karl's thesis mentions this should be fixed, but there are no tolerances given or go/no go values. And it's not clear how to do this without a major change to the system. There are alot of surface-to-surface mechanical contacts in the tower, so one would need to loosen lots of bolts and then possibly install shims and retorque down everything. Anyway---a big job. Since it is a small tilt, we are just noting it and decided to move on. In the future, the Fiber Puller will need to be upgraded to a taller tower, this will definitely give us the opportunity to remove the tilt from the tower (note: This could be a reason for [the known years-long issue of ] why we always have to make adjustments to the upper clamp translation stage almost every time we pull a fiber).
Red beam alignment
Once again, Jason very quickly went through an alignment onto our fiber stock. One nice thing: no "hot spot" on back side of stock!
CO2 beam alignment
A new stock was installed, and we heated it. We could clearly see the beam with the cameras at a lower power of 45%! (lower power than Attempt #1! Our 1st good sign!)
And the 2nd good signs was the forward & back alignment of the stock was GOOD (in other words, there was not an offset in this direction! Another sign the translation stage mechanical checks did us good!). The stock did show an offset in the other direction ("left/right"), so the translation stage was adjusted accordingly.
Additionally, the spot on the stock looked MUCH better on the cameras (3rd good sign! [see image 9]). There were minimal angles seen with the "ring spot" on the stock! Touched up the alignment a little more, but it was already better than how we looked in the morning. We were ready to pull!
Vaporization
Before pulling, wanted to get an idea of what laser power we could go up to before silica vaporization begins. Ryan can correct me here, but I believe Alan told us, we should do pulls at laser powers just lower than the laser power when silica vaporization occurs. The laser power was slowly ramped up, and I started seeing vaporization somewhere around 75-80% (it was very bright on the stock).
Polish & Pull
Not sure of what is the ideal values to use here, but to just do it, went with:
Although late in the afternoon, we went through the whole process. Fiber was profiled and then analyzed:
This is where we ended for that day.
Have continued to pull more fibers and get more data points with an eye on the fundamental (violin) mode frequencies. One knob we have here are those Polish & Pull powers.
NOTE: A reminder that even with the 100W laser toward the end, our fibers have been populating the lower range of violin mode frequencies (see fiber table). Something to think about.
Additional Note On Alignment & Power
With our nice alignment, it should also be noted we are still running at higher powers than what we are used to (which was at 85% or ~85W with the 100W). With the current 200W laser, we were running at ~140W in Aug for pulls and yesterday we were at ~135W. This would point to a the overall alignment in need of some improvement.
[end of email]
Here is a video DCC Link to fiber (S2400752) pulled on Aug 19, 2024:
https://dcc.ligo.org/LIGO-E2400339
Sat Oct 05 08:09:22 2024 INFO: Fill completed in 9min 18secs
More investigation similar to alog80358
NLN 1412064049 lockloss tool, no tag, FSS chans looks stable.
AS_A_DC and IMC-TRANS loose lock within ~250 ms
PREP_DC_READOUT_TRANSITION 1412066248 lockloss tool, FSS tag
AS_A_DC and IMC-TRANS loose lock within 1 ms of each other, but the FSS chans look stable before hand
NLN 1412077192 lockloss tool, tool failed
AS_A_DC and IMC-TRANS loose lock within ~5 ms, small FSS glitching starts almost 2 mins before LL, large glitch 1/2 a sec before
NLN 1412084422 lockloss tool, No FSSery
AS_A_DC and IMC-TRANS loose lock within ~250 ms
NLN 1412092628 lockloss tool, FSS tag
AS_A_DC and IMC-TRANS loose lock within ~5 ms, FSS glitching starts 5 secs before LL
NLN 1412101888 lockloss tool, FSS tag
AS_A_DC and IMC-TRANS loose lock within ~250 ms
TRANSITION_FROM_ETMX 1412105312 lockloss tool, FSS tag
AS_A_DC and IMC-TRANS loose lock within ~ 13 ms, the FSS starts glitching 40 seconds before LL, FSS_PC_MON_OUTPUT starts rising ~40 seconds before LL
LOW_NOISE_ESD_ETMX 1412113952 lockloss tool, no FSSery
AS_A_DC and IMC-TRANS loose lock within ~250 ms
NLN 1412131865 lockloss tool, FSS tag
AS_A_DC and IMC-TRANS loose lock within ~1 ms, there's a FSS glitch 1 second before the LL
To summarize, Ryan looked at 8 locklosses from today, 6 of them had the FSS tag, 5 of them had the IMC loose lock withing 15ms of the IFO losing lock, and only 3 of them had the pattern that Ian and Camilla found was normal in O4a, where the IMC looses lock ~250 ms after the IFO losses lock. This FSS issue seems to be having a serious impact on our duty cycle.
I had a helpful conversation with Rick this afternoon about this issue, he sugested that we trying looking for the glitches in other places in the PSL, so that we could think about tests where we don't run some of the feedback servos and see if we still see the issue. I made an ndscope template with all the PSL fast channels I could find, it is saved in sheila.dwyer/ndscope/PSL/PSL_fast_channels.yaml
Looking at 1412111658 with this scope, it looks like several of these channels that we are saving at a fast rate might not be connected, for example the OSC and HPL channels are around 0. The only other channel that clearly shows these glitches is H1:PSL-PWR_NPRO_OUT_DQ.
Request for operators: If you are having locking difficulties over the weekend, it may be due to the PSL/FSS problems. To help narrow down the cause of the problem one could sit for an hour or two with the FSS unlocked, and the ISS unlocked. If the glitches show up in the NPRO channel even without these servos locked, then we will know that the problem is not from the FSS, but from the NPRO.
Using Sheilas template for a few of these LLs.
NLN LL, It looks like the FSS started glitching first then the NPRO.
TRANSITION_FROM_ETMX LL, here it looks like the NPRO saw the first glitch then the FSS started glitching.
NLN LL, the NPRO power starts dropping 28 seconds before LL then the ISS, FSS, PMC and NPRO all glitch a ms before LL.
PREP_DC_READOUT_TRANSITION LL, not much going on here, some small FSS glitches and PSL_ILS_MIXER drops.
NLN LL, the FSS and NPRO seem to glitch at the same time ~5 sec before the LL, glitching gets more frequent closer to the LL.