Sat Sep 21 08:11:59 2024 INFO: Fill completed in 11min 55secs
TITLE: 09/21 Day Shift: 1430-2330 UTC (0730-1630 PST), all times posted in UTC
STATE of H1: Aligning
OUTGOING OPERATOR: Oli
CURRENT ENVIRONMENT:
SEI_ENV state: CALM
Wind: 10mph Gusts, 5mph 3min avg
Primary useism: 0.02 μm/s
Secondary useism: 0.15 μm/s
QUICK SUMMARY:
H1 had been stuck in IA for 1.5 hours, something was clearly yawed from the camera. I looked at the osems scopes for the PRC and the ITM, ETM, TMS and set the test mass sliders to recover the osem values from when we were locking on the 20th. ITMY_Y ended up having to be moved the most, now we're moving along IA at regular pace.
TITLE: 09/21 Eve Shift: 2330-0500 UTC (1630-2200 PST), all times posted in UTC
STATE of H1: Observing at 152Mpc
INCOMING OPERATOR: Oli
SHIFT SUMMARY: Very quiet shift, H1 remained locked throughout. Only events of note were a brief drop in observing because of the SQZ PMC and an earthquake passed through.
H1 has now been locked for just over 24 hours.
TITLE: 09/20 Day Shift: 1430-2330 UTC (0730-1630 PST), all times posted in UTC
STATE of H1: Observing at 153Mpc
INCOMING OPERATOR: Ryan S
SHIFT SUMMARY:
LOG: The range was in the upper 150s for most of shift, we've been locked for almost 19 hours!
Start Time | System | Name | Location | Lazer_Haz | Task | Time End |
---|---|---|---|---|---|---|
23:58 | SAF | H1 | LVEA | YES | LVEA is laser HAZARD | 18:24 |
16:08 | PEM | Robert | Yarm | N | PEM measurements, left at 16:20, 18:22 | 17:28 |
22:11 | VAC | Janos | Site | N | Cryopump checks | 22:27 |
23:16 | PEM | Robert | Y-arm | N | Setup test equipment | 01:16 |
HAM6 OMC TRANS camera was pretty jittery the whole shift
18:15 UTC, EDC reports 12 DC chans again, from NUC33. The NUC doesn't look frozen as the SQZ plot is still updating.
TITLE: 09/20 Eve Shift: 2330-0500 UTC (1630-2200 PST), all times posted in UTC
STATE of H1: Observing at 152Mpc
OUTGOING OPERATOR: Ryan C
CURRENT ENVIRONMENT:
SEI_ENV state: CALM
Wind: 16mph Gusts, 9mph 3min avg
Primary useism: 0.02 μm/s
Secondary useism: 0.10 μm/s
QUICK SUMMARY: H1 has been locked and observing for 18 hours. Sounds like it's been a quiet day.
We've been locked for a little over 14 hours, its been a calm day.
The range has been in the high 150s all morning.
The low range check yielded < ~14 Hz SRCL & CHARD_Y (and at >95Hz), and > ~14 Hz PRCL (and at >95Hz) & DHARD_Y coherence.
Fri Sep 20 08:09:52 2024 INFO: Fill completed in 9min 48secs
Closes FAMIS26298
Laser Status:
NPRO output power is 1.824W (nominal ~2W)
AMP1 output power is 64.37W (nominal ~70W)
AMP2 output power is 137.4W (nominal 135-140W)
NPRO watchdog is GREEN
AMP1 watchdog is GREEN
AMP2 watchdog is GREEN
PDWD watchdog is GREEN
PMC:
It has been locked 23 days, 21 hr 37 minutes
Reflected power = 22.08W
Transmitted power = 104.2W
PowerSum = 126.3W
FSS:
It has been locked for 0 days 11 hr and 13 min
TPD[V] = 0.804V
ISS:
The diffracted power is around 2.2%
Last saturation event was 0 days 11 hours and 13 minutes ago
Possible Issues:
AMP1 power is low, there was a step down about 47 days ago.
PMC reflected power is high, it appears to have been rising for the past >2 months.
TITLE: 09/20 Day Shift: 1430-2330 UTC (0730-1630 PST), all times posted in UTC
STATE of H1: Observing at 150Mpc
OUTGOING OPERATOR: Oli
CURRENT ENVIRONMENT:
SEI_ENV state: CALM
Wind: 10mph Gusts, 6mph 3min avg
Primary useism: 0.02 μm/s
Secondary useism: 0.08 μm/s
QUICK SUMMARY:
We dropped observing from 13:14 to 13:18 UTC this morning, it appears to be from the SQZer loosing lock and relocking itself. The PMC GRD specifically.
TITLE: 09/20 Eve Shift: 2330-0500 UTC (1630-2200 PST), all times posted in UTC
STATE of H1: Observing at 157Mpc
INCOMING OPERATOR: Oli
SHIFT SUMMARY: High winds this evening which possibly contributed to the one lockloss. Relocking was automated and otherwise a quiet shift.
LOG:
No log for this shift.
Lockloss @ 03:53 UTC - link to lockloss tool
No extremely obvious cause, but seeing as winds have recently gusted up to over 30mph and multiple suspensions seem to have started shaking about a second before the lockloss, my initial assumption is that this was wind-related.
Range had also started dropping for about 30 minutes prior to the lockloss, possibly due to the higher winds? (trend attached)
Back to observing at 04:49 UTC. Fully automated relock without an initial alignment, however many signals are shaky and acquisition took slightly longer due to high winds.
PI mode 31 started ringing up shortly after NLN. Guardian was able to damp it down, but not until mode 24 also started rising and damping started on that mode. Unsure if this is a coincidence or if damping mode 24 is actually what brought down mode 31.
TITLE: 09/19 Day Shift: 1430-2330 UTC (0730-1630 PST), all times posted in UTC
STATE of H1: Observing at 155Mpc
INCOMING OPERATOR: Ryan S
SHIFT SUMMARY: Three lock losses during my shift. Two of them are unknown. All reacquisitions have been fully auto. SR3 oplev sums are low since the SR3 move last week. Plans to fix this next maintenance day.
LOG:
Start Time | System | Name | Location | Lazer_Haz | Task | Time End |
---|---|---|---|---|---|---|
23:58 | SAF | H1 | LVEA | YES | LVEA is laser HAZARD | 18:24 |
15:10 | FAC | Kim | Opt lab | n | Tech clean | 15:11 |
16:19 | PEM | Robert | LVEA | yes | Setup injections | 18:43 |
18:05 | ISC | Sheila | LVEA | yes | Plug in cable by PSL racks | 18:15 |
18:14 | CDS | Fil | MY | n | Part dropoff and fiber testing | 19:15 |
23:03 | TCS | TJ | MER | n | Checking TCS chillers | 23:13 |
Samantha Callos, Robert Schofield
We identified 3 peaks (26.4 Hz, 27 Hz, and 29.5 Hz) in DARM resulting from HVAC systems and the CS Chiller; 1 peak between 26.4 Hz and 27 Hz remains unidentified. See Fig. 1.
The first peak at 26.4 Hz's source has been found to be the office HVAC system, as shown in Fig. 2. There are two gaps corresponding to when Robert shut down the HVAC system (from alog 79888). Fig. 3 shows the peak at 26.4 Hz disappears in DARM for when the office HVAC is off vs when it is on.
The second peak varies between 26.5 Hz and ~26.7 Hz. It has yet to be identified, but we do know:
The third (27 Hz) peak's source is the mini splits HVACs controlled by the downstairs thermostat of the CER, as shown in Fig. 4 when the CER HVAC was shut down (alog 80049). It also shows the second round of shut downs of the office HVAC from alog 79888 which reconfirms the first peak. Fig. 5 shows the peak in the mics disappearing when the "downstairs" bank of the mini splits in the CER were turned off.
The fourth peak's source is the CS main chiller unit, Fig. 6, at 29.5 Hz. This shut down was done by Robert on June 29th, 2024 (alog 78749). A microphone placed across the road from the chiller pads showed that the 29.5 Hz peak seen in the permanent microphones is much louder near the chillers (see Fig. 7).
Finally, in Fig. 8, the coherence between DARM and floor accelerometers is shown for the peaks mentioned above.
The line heights of some of the PCAL lines in the cleaned channel have been much higher than actual at the begining of todays' locks (attachment 1). The relock yesterday didn't have it (attachment 2). Looks like this was potentially fixed a month ago - alog79558, but perhaps the locks from today are too short?
This is most likely caused by a slightly different issue that what was addressed in LHO aLOG 79558. In some instances, the line subtraction TFs are not updating properly at the beginning of lock stretches. I am working on a fix for this.
Followed instructions in 74681. Last done in 78782, 79988. Saved in /ligo/gitcommon/NoiseBudget/aligoNB/aligoNB/H1/couplings/ and pushed to git.
CHARD_P, CHARD_Y, MICH, PRCL, SRCL screenshots attached. The IFO had been in NLN for 4h15 when these were taken. The AS_A_YAW and PRCL offsets were turned off.
I modified the script used in 78969 to project PRCL noise to DARM through MICH and SRCL, and now added coupling through CHARD P + Y.
There is high coherence between PRCL and CHARD, but these active injections that Camilla did show that the main coupling of PRCL to DARM is not through CHARD.
This script is now in /ligo/gitcommon/NoiseBudget/simplepyNB/PRCL_excitation_projections.py (not actually a git repo)
Sheila, Vicky - we ran the noise budget using these updated couplings from Camilla.
Noise budget with squeezing - pdf and svg (and the quantum sub-budget with squeezing). Plots without unsqueezed DARM here: pdf and svg. Picked a time with high range, and good ~4.8dB squeezing.
Noise budget without squeezing - pdf and svg (and the quantum sub-budget without squeezing).
The remaining sub-budgets are for squeezed DARM: Laser, Jitter, LSC, ASC, Thermal, PUMDAC.
Noise below 25 Hz looks pretty well accounted for: 10-15 Hz ~ ASC (CHARD Y, then CSOFT P, CHARD P). 15-20 Hz ~ LSC (PRCL).
Some comments and caveats for these budget plots:
The code has been pushed to aligoNB repo, commit 95d3a88b. To make these noise budget plots:
Thanks to Erik von Reis for helping us update the aligoNB environment to newer python and scipy (etc) versions. Next to-do: have the budget code use median averaging to be more robust to glitches (which can be done now that the environment has an updated scipy!).
Sheila, Louis, Francisco
Following LHO:80044, we measured ASC-DHARD_P(Y) for different ASC-AS_A_DC_YAW_OFFSET and found the loswet values of DHARD_Y at an offset of -0.05.
The "DTT_AS_A_*.png"s show the outputs of DHARD_DARM_240912 when changing AS_A_DC_OFFSET with a reference trace for when the offset was nominal (ASC-AS_A_DC_YAW_OFFSET = -0.15). Each trace has a marker at the two highest peaks in the ASC-DHARD power spectrum (the middle plot on the left). DTT_AS_A_neg0_05 shows the lowest value in the power spectrum compared to DTT_AS_A_neg0_10, while preserving coherence (lowest-left) and phase values (middle-rigt), compared to DTT_AS_A_0. AS_A_NDSCOPE corroborate on the times at which these measurements were done and the values for AS_A offset.
Confirming that the four TFs traces corresponding to reports
were all done under a thermalized interferometer.
Vicky, Sheila, Naoki
First we tried SRCL offset of -400, which looked good in yesterday's FIS SRCL offset measurement 79903. We took the calibration measurement with SRCL offset of -400 in 79911, but Louis reported in the mattermost that there is a large optical spring in the sensing function. Also, FDS with SRCL offset of -400 is worse than nominal. Vicky will add more plots for this.
Then we decided to change the SRCL offset to -290 and optimized FC detuning. This improved the sensitivity below 100 Hz as shown in the first attachment and improved the range by ~5Mpc. The optimal FC detuning changed from -34 Hz to -28 Hz and this could be because of SRCL offset change and arm power change.
After FC detuning improvement, we took the calibration measurement with SRCL offset of -290 in 79922, but the measurement did not make sense according to Louis so we took an another calibration measurement with SRCL offset of -290 in 79928.
Following up with some FIS SRCL measurements from today as we were navigating how to best optimize SRCL offset for squeezing, which gives best sensitivity around 100 Hz.
Blue & purple traces - When first looking at SQZ after re-calibrating at -400 counts srcl offset, SQZ looked kinda v-shaped, like as if the SRCL detuning is big. We first tried optimizing the sqz angle for the bucket (blue, CLF RF6 demod phase @ 222 deg), then tried to optimize high-freq sqz (purple, CLF RF6 @ 215deg). For this SRCL offset at -400 counts, with about (222-215=) 7 degrees difference on the CLF RF6 demod phase (bad estimate is ~3.5deg diff on sqz angle), this changed the kHz squeezing level by about 1.9dB. See the trends on this screenshot.
Yellow trace - We then tried to see if FIS + SRCL @ -400 counts was the same as yesterday lho79903 and yes it was same. But zooming into yesterday's plots, it looks like this -400 SRCL offset setting (yesterday's blue trace) was actually not a great spot (already well passed zero detuning), as there is a little bit of ballooning between 100-200Hz that we did not notice yesterday.
Given that squeezing, and also calibration, saw that this SRCL offset @ -400 cts had a bad spring effect, we backed it off to -290 counts and took another cal meausrement. We chose -290 to be ~halfway between the -475 ct (pink) and -100 ct (black) settings tried yesterday (see dtt). For -475 ct and -100 ct, we realized today that DARM between 250-500 Hz had about the same level of anti-sqz coupled in by the SRCL detuning. Unsure if this means they have the same physical detuning, this is something we will try out in quantum noise models to understand better.
Green trace - shows FIS + SRCL @ -290 counts. It is where we expected from yesterday. Leaving it here.
In summary, today we tried a few methods of "optimizing srcl detuning," to get it closer to 0, but also realized we need to think more carefully with quantum noise models like, what is the easiest / most sensitive metric for squeezing to see the srcl detuning.
We then moved onto FDS + SRCL @ -290 counts, and optimized the filter cavity detuning, as Naoki describes above.
Adding plots of the sensing function. From these measurements, we see that the sensing function is also an indicator of bad/good SRCL offset. Additionally, *something* changed from Thursday to Saturday, as seen in the Saturday calibration measurement trace.
Figures (1) and (2) are the different sensing functions where the second figure ranges from 0-40 Hz. The uncertainties of each measutrement are plotted in figures (3) and (4), where figure (4) ranges from 0-40Hz.