Yesterday we added the remote access ioc (RACCESS) uid channels to the DAQ so they can be trended.
I have written a progam called who_is_logged_in which takes any gpstime format and lists who was logged into CDS remotely at that time.
The epoch for these channels is noon Tue 10 Sept 2024.
Example:
who_is_logged_in "17:00 yesterday"
Who is logged remotely into CDS on Tue Sep 10 17:00:00 2024 PDT
cdsssh Number of users 5
cdsssh elenna.capote (1 session)
cdsssh erik.vonreis (1 session)
cdsssh ezekiel.dohmen (1 session)
cdsssh gerardo.moreno (1 session)
cdsssh louis.dartez (2 sessions)
cdslogin Number of users 1
cdslogin david.barker (1 session)
The code uses minute trend data, so you will get the login list rounded to the minute.
If you ask for who is logged in now, it defaults to 10 minutes ago because minute trend data is not immediately available, e.g.
who_is_logged_in now
Who is logged remotely into CDS on Wed Sep 11 13:32:16 2024 PDT
cdsssh Number of users 7
cdsssh elenna.capote (1 session)
cdsssh erik.vonreis (1 session)
cdsssh ezekiel.dohmen (1 session)
cdsssh gerardo.moreno (1 session)
cdsssh jim.warner (1 session)
cdsssh louis.dartez (2 sessions)
cdsssh tyler.guidry (1 session)
cdslogin Number of users 2
cdslogin david.barker (1 session)
cdslogin root (1 session)
TJ, Camilla.
We turned on the HWS lasers via medm and the LVEA chassis, they came back with the same powers we turned them off with (1.7mW for Y and 3.2mW for X). Since we realigned SR3 to the pre-April alignment yesterday 80028, both beams are on the CCD cameras, picture. The HWS plates are still removed from when we started alignment work in 78083. We will need to replace these before getting HWS signals, then restart HWS code.
CO2X chassis tripped off with the "RTD or IR alarm" error when I turned on the HWS SLED chassis (same rack). Turned back on with no issue (keyed off/on, gate button). We've seen similar behavior before. These CO2 chassis are planning an upgrade as per FRS6639.
I found the LVEA, clean receiving entrance and EE bay lights still on, turned them off but they would have been on during observing since yesterday, tagging Detchar.
There was an earthquake rumbling through the site from Papua New Guinea during commissioning this morning, so Sheila suggested we could try the IMC gain redistribution again, as we got several notifications of IMC splitmon saturations. To do this, we commented out the IMC power adjust decorator in the IMC_LOCK guardian, unfortunately in the wrong state, so we again got bit by IMC_LOCK readjusting IMC fast gain while we were trying to change IMC fast gain and IN1 and IN2 gains. After losing lock and catching the error, the decorator was commented out in the ISS_ON state for IMC_LOCK, and the gain redistribution was added to ISC_LOCK's LASER_NOISE_SUPPRESSION state. Still waiting for the ground to calm down enough for the arms to stay locked, but we will try locking with the gain redistribution in this time.
I realized that there isn't an explict alog about this because Paul was asking, so I'm adding this trend to show that after the OFI repair our optical gain is better by about 2.1%, implying that the optical losses are reduced by 4.3%. While the OM2 heaters is now off and was on before the vent, that didn't have a large impact on optical gain last time that we changed it in late June.
Wed Sep 11 08:12:51 2024 INFO: Fill completed in 12min 47secs
WP12069 New CDS NAT router test
Jonathan:
The new CDS NAT router was tested successfully. It has been left in place as the production machine. Details in Jonathan's alog.
WP12067 Add PEM ADC to h1iscey
Fil, Erik, Dave:
The additional PEM ADC was added to h1iscey's IO Chassis. At the same time the failed A2 Adnaco backplane in the chassis was investigated.
After replacing backplanes and swapping fibers the problem was traced to the Adnaco adapter card in the front end computer, specifically the PCIe slot it was in (slot7, left-most as viewed from rear of computer).
h1iscey does not have any Contec binary IO cards, so it was possible to skip PCIe-slot7 and temporarily only use three Adnaco adapter cards.
h1iopiscey model was modified to add the new ADC. A DAQ restart was required
WP12076 Add VACSTAT EPICS channels to DAQ
Dave:
A new H1EPICS_VACSTAT.ini was added to the DAQ. EDC+DAQ restart required.
WP12075 Add RACCESS UID EPICS channels to DAQ
Dave:
H1EPICS_RACCESS.ini was expanded to add the UID channels. EDC+DAQ restart required.
WP12059 Add CDS HW Status EPICS channels to DAQ
Dave:
H1EPICS_CDSHWSTAT.ini was added to the DAQ. DAQ+EDC restart required.
DAQ Restart
Dave:
The DAQ was restarted 12:01 0-leg, 12:05 1-leg for the above changes. EDC was restarted at 12:02.
No problems with the restart, no second GDS restarts were required.
h1digivideo3 cameras briefly offline
Dave:
While tracing the digital video servers ethernet cabling I discovered the WorkStation-VLAN ethernet cable in eth0 of h1digivideo3 was not fully seated and its cameras went blue-screen.
After Erik alerted me to the issue, I pushed the ethernet cable and it reseated with a satisfying snap and the images started streaming again.
h1iscey bad PCIe slot7 FRS32088
Tue10Sep2024
LOC TIME HOSTNAME MODEL/REBOOT
08:57:28 h1iscey ***REBOOT*** <<< Add ADC and Debug A2 in IO Chassis
08:59:10 h1iscey h1iopiscey
10:01:35 h1iscey ***REBOOT***
10:03:17 h1iscey h1iopiscey
10:07:24 h1iscey ***REBOOT***
10:09:11 h1iscey h1iopiscey
10:09:24 h1iscey h1pemey
10:09:37 h1iscey h1iscey
10:29:13 h1iscey ***REBOOT***
10:30:57 h1iscey h1iopiscey
10:31:10 h1iscey h1pemey
10:31:23 h1iscey h1iscey
10:31:36 h1iscey h1caley
10:31:49 h1iscey h1alsey
12:01:46 h1daqdc0 [DAQ] <<< 0-leg restart
12:01:58 h1daqfw0 [DAQ]
12:01:58 h1daqtw0 [DAQ]
12:01:59 h1daqnds0 [DAQ]
12:02:07 h1daqgds0 [DAQ]
12:02:58 h1susauxb123 h1edc[DAQ] <<< EDC restart
12:05:00 h1daqdc1 [DAQ] <<< 1-leg restart
12:05:12 h1daqfw1 [DAQ]
12:05:12 h1daqtw1 [DAQ]
12:05:13 h1daqnds1 [DAQ]
12:05:22 h1daqgds1 [DAQ]
TITLE: 09/11 Day Shift: 1430-2330 UTC (0730-1630 PST), all times posted in UTC
STATE of H1: Observing at 150Mpc
OUTGOING OPERATOR: TJ
CURRENT ENVIRONMENT:
SEI_ENV state: CALM
Wind: 6mph Gusts, 4mph 3min avg
Primary useism: 0.01 μm/s
Secondary useism: 0.14 μm/s
QUICK SUMMARY:
IFO is in NLN and OBSERVING as of 14:16 UTC.
SQZ is not perfectly optimized just looking at DARM.
Planning on going into planned calibration from 8AM PST to 10AM PST (15-17 UTC)
The IFO timed out during initial alignment because ALS Y would not lock. Flashes were at 0.8 but it wouldn't catch. I tried to manually move ETMY, TMSY, and eventually ITMY, but I couldn't increase the height of the flashes. After about 30 min of fussing with it, it caught and stayed locked. I have no idea what was different though.
Initial alignment has just finished and main locking has commenced.
TITLE: 09/11 Eve Shift: 2330-0500 UTC (1630-2200 PST), all times posted in UTC
STATE of H1: Observing at 151Mpc
INCOMING OPERATOR: TJ
SHIFT SUMMARY: Easy automated acquisitions but some short locks following the SR3 move, 22 and 14 minutes, the 3rd lock we were able to survive. The low range check yielded high PRCL, CHARD_Y, and a little DHARD_Y (mostly just at low frequency, <20Hz) coherence with cleaned DARM. We've been locked for almost 5 hours. LLO is currently down due to the incoming tropical storm/hurricane.
Naoki, Vicky
We are back to observing after the SR3 move. For SQZ, we had to move quite a lot to get the SQZ LO loop to lock (Naoki mostly moved ZM5 yaw sliders around +200 urad).
PSAMS SDFs attached to get back to our recent values (not the single-bounce values we found this morning in lho80010, but what we used yesterday / last couple weeks). So ZM 4,5 strains = +5.5V, -0.8V as they were yesterday.
We weren't able to try these new values properly in full lock because
1) OPO TEC temperature was off, Naoki had to move the OPO TEC setpoint from 31.474 --> 31.457 (ie, lowered it by 0.017 degC). Noticed this because anti-squeezing was like 2-3 dB too low.
2) SR3 move meant a big alignment shift for SQZ, regardless of PSAMS settings. The new SCAN_ALIGNMENT plots now also include OMC_RF3_Q so we can compare whether this is a usable signal for SQZ ASC.
So now we're basically back to where we were this morning, after the sr3 move. We can try the single-bounce psams settings from lho80010 in full lock another time.
TITLE: 09/10 Day Shift: 1430-2330 UTC (0730-1630 PST), all times posted in UTC
STATE of H1: Preventive Maintenance
INCOMING OPERATOR: Ryan C
SHIFT SUMMARY:
We’re trying to get to observing but waiting on SQZ Team to finish alignment. We've reached NLN twice now.
Locking started at 19:58 UTC where after our SR3 move, we went into initial alignment in prep for full IFO locking. Initial alignment finished at 20:37 UTC. It took a while because we had to move SRM to alignment with the new SRM and SR2 positions.
We fully automatically got to NLN at 21:18 UTC but lost lock 22 minutes later (21:41 UTC) for unknown reasons. We didn’t get to observing due to SQZ commissioning work happening at that time.
Following the lockloss, we were not able to lock X-Arm ALS, losing lock twice unexpectedly, prompting yet another initial alignment. This initial alignment stalled at SRC align, which was unexpected considering we just moved SRM to proper alignment manually at this state. Ryan C paused the state and apparently that was all that was needed in order for initial alignment to re-catch, finishing the process. Onto real locking.
We lost lock unexpectedly at CHECK_IR but in relocking, were able to lock DRMI without going through PRMI or MICH. We then fully automatically got to NLN for a second time. SDF Diffs from first NLN acquisition attached.
UPDATE 16:21 UTC:
We lost lock again from NLN during SQZ alignment, convincing me that perhaps the previous LL was also SQZ related. 14 min lock. On the bright side, it seems we are reliably locking to NLN following the SR3 movement.
Other:
Other/Opportunistic (All times in UTC):
LOG:
Start Time | System | Name | Location | Lazer_Haz | Task | Time End |
---|---|---|---|---|---|---|
23:58 | SAF | H1 | LHO | YES | LVEA is laser HAZARD | 18:24 |
14:43 | FAC | Karen | Optics, Vac Prep Labs | N | Technical Cleaning | 15:20 |
15:19 | FAC | Karen | EY | N | Technical Cleaning | 16:37 |
15:20 | FAC | Kim | EX | N | Technical Cleaning | 16:37 |
15:21 | IAS | Jason | LVEA | YES | Faro Movement | 15:58 |
15:21 | CDS | Fil | EY | N | PEM Chassis Change | 17:42 |
15:32 | FAC | Christina | Receiving/Hi-Bay | N | Forklift recycling | 18:46 |
15:32 | VAC | Jordan, Erik | LVEA | YES | HAM6 RGA | 16:03 |
15:34 | FAC | Nellie | FCES | N | Technical Cleaning | 16:36 |
16:06 | VAC | Jordan, Erik | LVEA | YES | HAM6 RGA: Part 2 | 16:25 |
16:21 | OPS | TJ | LVEA | YES | TCS Line Inspection | 16:49 |
16:22 | CDS | Marc | EX | N | DAC Transition from read only to read&write | 17:55 |
16:37 | SUS | Betsy, Travis | LVEA | YES | LVEA Chamber Sweep | 17:25 |
16:38 | IAS | Jason, Mitchell | LVEA | YES | FARO Work | 18:51 |
16:45 | FAC | Tyler | LVEA, MX, MY | YES, N, N | Routine 3IFO Checks | 18:11 |
17:01 | FAC | Karen, Kim | LVEA | YES | Technical Cleaning | 18:24 |
17:29 | SEI | Jim | LVEA | YES | Checking HAM1/2 cleanroom | 18:27 |
17:55 | FAC | Chris | LVEA | YES | Battery Maintenace | 18:16 |
18:01 | VAC | Janos, Gerardo | LVEA | YES | Capturing Photos | 18:20 |
18:01 | CDS | Marc | EX | N | DAC Transition Ctd. | 19:11 |
18:17 | FAC | Chris | FCES | N | Snorkel-lift Battery Maintenance | 20:16 |
22:20 | FAC | Chris | Optics Lab | N | Battery Check | 20:20 |
Marc Daniel
We measured the gain and phase difference between the new DAC and the existing 20-bit DAC in SUS ETMX. For this we injected 1kHz sine waves and measure gain and phase shifts between the two. We started with a digital gain value of 275.65 for the new DAC and adjusted it to 275.31 after the measurement to keep the gains identical. The new DAC implements a digital AI filter that has a gain of 1.00074 and a phase of -5.48° at 1kHz, which corresponds to a delay of 15.2µs.
This puts the relative gain (new/old) to 1.00074±0.00125 and the delay to 13.71±0.66µs. The variations can be due to the gain variations in the LIGO DAC, the 20-bit DAC, the ADC or the AA chassis.
DAC | Channel Name | Gain | Adjusted | Diff (%) | Phase (°) | Delay (us) |
0 | H1:SUS-ETMX_L3_ESD_DC | 1.00239 | 1.00114 | 0.11% | -5.29955 | -14.72 |
1 | H1:SUS-ETMX_L3_ESD_UR | 1.00026 | 0.99901 | -0.10% | -5.10734 | -14.19 |
2 | H1:SUS-ETMX_L3_ESD_LR | 1.00000 | 0.99875 | -0.12% | -4.93122 | -13.70 |
3 | H1:SUS-ETMX_L3_ESD_UL | 1.00103 | 0.99978 | -0.02% | -5.11118 | -14.20 |
4 | H1:SUS-ETMX_L3_ESD_LL | 1.00088 | 0.99963 | -0.04% | -5.21524 | -14.49 |
8 | H1:SUS-ETMX_L1_COIL_UL | 1.00400 | 1.00275 | 0.27% | -4.72888 | -13.14 |
9 | H1:SUS-ETMX_L1_COIL_LL | 1.00295 | 1.00170 | 0.17% | -4.88883 | -13.58 |
10 | H1:SUS-ETMX_L1_COIL_UR | 1.00125 | 1.00000 | 0.00% | -5.08727 | -14.13 |
11 | H1:SUS-ETMX_L1_COIL_LR | 1.00224 | 1.00099 | 0.10% | -4.92882 | -13.69 |
12 | H1:SUS-ETMX_L2_COIL_UL | 1.00325 | 1.00200 | 0.20% | -4.78859 | -13.30 |
13 | H1:SUS-ETMX_L2_COIL_LL | 1.00245 | 1.00120 | 0.12% | -4.55283 | -12.65 |
14 | H1:SUS-ETMX_L2_COIL_UR | 1.00175 | 1.00050 | 0.05% | -4.52503 | -12.57 |
15 | H1:SUS-ETMX_L2_COIL_LR | 1.00344 | 1.00219 | 0.22% | -5.00466 | -13.90 |
Average | 1.00199 | 1.00074 | 0.07% | -4.93611 | -13.71 | |
Standard Deviation | 0.00125 | 0.00125 | 0.13% | 0.23812 | 0.66 |
FPGA filter is
zpk([585.714+i*32794.8;585.714-i*32794.8;1489.45+i*65519.1;1489.45-i*65519.1;3276.8+i*131031; \
3276.8-i*131031;8738.13+i*261998;8738.13-i*261998], \
[11555.6+i*17294.8;11555.6-i*17294.8;2061.54+i*26720.6;2061.54-i*26720.6;75000+i*93675; \
75000-i*93675;150000+i*187350;150000-i*187350;40000],1,"n")
TITLE: 09/10 Eve Shift: 2330-0500 UTC (1630-2200 PST), all times posted in UTC
STATE of H1: Preventive Maintenance
OUTGOING OPERATOR: Ibrahim
CURRENT ENVIRONMENT:
SEI_ENV state: CALM
Wind: 19mph Gusts, 12mph 3min avg
Primary useism: 0.02 μm/s
Secondary useism: 0.10 μm/s
QUICK SUMMARY:
TJ and I turned up the CO2s from 1.7W to 2.0W today before we lost lock for Tuesday Maintenance at 2024/09/10 15:10 UTC. We then lost lock at 2024/09/10 15:18 UTC. We did this after mention that PRCL to CHARD coupling could be reduced by CO2 power changed in 79989, but we didn't have time to think about if we should make an injection.
Checked when we turned the CO2s up for 7 minutes, that this had no noticeable effect on squeezing level or sqz alignment, plot attached. But maybe 7 minutes isn't long enough to see any changes, we could try again with more time or try turning the CO2s off before Tuesday Maintenance
Checking as LLO sees the Squeezing and SQZ alignment/mode matching may be related to changes in CO2 power (or alignment), see 72244.
Closes FAMIS 28370
All the measurements ran, ITMX could not be processed due to low bias_drive_bias_off coherence.
No clear trends, everything seems steady.
Vicky, Camilla
Repeated 66946 PSAMs changes with SQZ-OMC scans with a new method of dithering the PZT around the TEM02 mode and minimizing it. With this we improved the mode mismatch from 4% to 3%. It will interesting to see if these settings are still better in full lock. Plots of OMC scan attached and same plot zoomed on peaks attached.
Took OMC scans using tempalte /sqz/h1/Templates/dtt/OMC_SCANS/Sept10_2024_PSAMS_OMC_scan_coldOM2.xml Unlock OMC and H1:OMC-PZT2_OFFSET to -50 (nominal is-17) before starting scan.
ZM4/5 PSAMs | TEM00 | TEM02 |
Mismatch
(% of TEM02)
|
Notes | Ref on Plot |
5.5V/-0.8V | 0.6362 | 0.02684 | 4.048% | Starting | 0 (pink) |
4.0V/0.34V | 0.6602 | 0.02332 | 3.412% | Maximized TEM00 | 1 (blue) |
2.1V/0.2V | 0.6611 |
0.02097 |
3.074% | Minimized TEM02 | 2 (green) This is 0V on the ZM4 PZT. |
3.0V/0.85V | 0.6609 | 0.02209 | 3.234% | Minimized TEM02 | 3 (orange) |
4.0V/0.34V | N/A | N/A | N/A | Minimized TEM02 | Didn't scan, checked that we got similar results with different method of minimumizing TEM02 rather than maximizing TEM00 |
8.1V/-0.4V | 0.6422 | 0.03432 | 5.073% |
Minimized TEM02
|
4 (cyan)
Chose similar ZM4 settings to what we found was good in full lock with cold OM2 in 76986
|
2.1V/-0.1V |
0.6591 | 0.02162 | 3.176% | Minimized TEM02 | 5 (red) |
2.1V/0.2V |
0.6580 | 0.01954 | 2.884% | Back to best ref2 PSAMS values | 6 (brown) LEAVING HERE |
Over 1V and under -1V on ZM5 is bad at most ZM4 strains (tested at 4.0V ZM4). For each step we adjusted ZM4 and then fine adjusted ZM5.
Note OM2 is cold currently for this measurement (and since the vent it seems).
With the orginal PSAMs (5.5V/-0.8V) we had:
At the better PSAMS settings (2.1V/0.2V) plot attached:
We made some improvements today in the sensitivity, going from about 151 Mpc on GDS CLEAN to about 158 Mpc. However, our best range from April 11th (DARM FOM reference pre-OFI disaster) is around 165 Mpc. I made a comparison of that time and now with today's commissioning improvements to see where we are still missing range. I have attached the four plot results from the darm_integral_compare results (see alog 76935 for directions).
The range integrand plot makes it much easier to see that we are still missing sensitivity around the mid-frequency band. However, the sensitivity difference shows that we lose 5 Mpc of range by 40 Hz as well. Much of this range loss seems to come from a variety of peaks that have appeared since the OFI vent, such as the 20 Hz peak. We lose another ~3 Mpc between 40-200 Hz.
I ran a bruco with GDS CALIB STRAIN CLEAN on high range time after commissioning today: post-commissioning bruco
It looks like many of these new low frequency peaks (like the large 20 Hz peak) are well witnessed by things like PSL accelerometers, indicating that they could be from jitter: PEM-CS_ACC_PSL_TABLE1_Y_DQ
Generally, there is a lot of jitter coherence, and given that this is the CLEAN channel, that's probably a sign that the jitter cleaning could be improved, maybe making use of other witness channels if the current witnesses are insufficient to subtract the noise.
A peak at 30 Hz has some coherence with MAG sensor channels, here is one: PEM-CS_MAG_LVEA_VERTEX_X_DQ
Right around 35.4 Hz, there is a lot of coherence with various ISI HAM6 sensors and OMC ASC sensors. For example: ISI-HAM6_GS13INF_V1_IN1_DQ
There is also still a large amount of LSC REFL RIN coherence up to 1 kHz: LSC-REFL_RIN_DQ
I think we should test the PRCL offset again, especially because this will help reduce the CHARD Y noise coupling (ASC-CHARD_Y_OUT_DQ) and will also possibly help this HF noise (frequency noise? intensity noise?)
SRCL is better than before, but maybe has more room for improvement between 10-25 Hz: LSC-SRCL_OUT_DQ
DHARD Y coherence is low, but still present, so we should be careful with the WFS offset: ASC-DHARD_Y_OUT_DQ
There is still PRCL coherence: LSC-PRCL_OUT_DQ which is likely coupling through a combination of CHARD Y, SRCL, and LSC REFL RIN. Again a PRCL offset will help. Other strategies are to check POP phasing, POP sensing, etc. Reminder: PRCL feedforward failed, so we need to consider other avenues for noise reduction.
To summarize some strategies to get back to April sensitivity:
Editing because I went back to check the previous PRCL offset work and found this comment: 76818, in short, we can fix the REFL RIN coherence, but it has no effect on the sensitivity. However, it can improve CHARD Y noise, although at the time I don't think we were limited by CHARD Y enough to see the low frequency benefit.
Regarding the 20 Hz line, this line disappeared from DARM yesterday (Sept 5) from roughly 12:45 - 14:15 UTC. Matching Elenna's note about coherence with PSL environmental channels, the same line disappears from the PSL microphones and accelerometers at the same time. Furthermore, there are short time windows where this line dissapears from PSL channels. This behavoir happens roughly (not the exact same gap each time) at 2 hour intervals.
These clues may be helpful for any investigation into the source of this line.
Another note about PRCL Offsets and CHARD Y:
I have attached a screenshot plot comparing the PRCL offset on/off times with the noise in CHARD Y (I used the on/off times from this April alog: 76814). The PRCL offset did reduce the noise in CHARD Y a small amount, and also reduced the CHARD Y coherence with DARM. I don't think at the time of this test we were limited by CHARD Y, so we didn't actually see a change in sensitivity from this test. Therefore, it's worth trying the offset again since we seem to have more CHARD Y noise coupling right now.
Here is a comparison of a longer-span time from April and from last night's lock. Using 2 hour blocks of no-glitch time I created these darm comparison plots.
There were further small improvements in the sensitivity from when these plots were last made, so they are not completely comparable to the plots in the original alog.
These plots indicate that we have actually gained some low frequency sensitivity since April, although we are definitely seeing more peaks around low frequency than before the emergency vent. We are still missing some range around 100 Hz.