X1 SUS (SUS)
ibrahim.abouelfettouh@LIGO.ORG - posted 18:57, Thursday 05 September 2024 - last comment - 16:19, Saturday 07 September 2024(79941)
BBSS M1 Pitch Instability F1 BOSEM Drift: The Saga Continues

Ibrahim, Oli, Jeff, Betsy, Joe, Others

Summary:

Relevant Alogs:

alog 79079: Recent Post-TF Diagnostic Check-up - one of the early discoveries of the drift and pitch instability.

alog 79181: Recent M1 TF Comparisons. More recent TFs have been taken (found at: /ligo/svncommon/SusSVN/sus/trunk/BBSS/X1/BS/SAGM1/Data on the X1 network). We are waiting on updated confirmation of model parameters in order to know what we should correctly be comparing our measurements to. We just confirmed d4 a few days ago following the bottom wire loop change and now seek to confirm d1 and what that means with respect to our referential calibration block.

alog 79042: First investigation into the BOSEM drift - still operating erroneously under the tmperature assumption.

alog 79032: First discovery of drift issue, originally erroneously thought to be part of the diurnal temperature driven suspension sag (where I though that blades sagging more than others contributed to the drift in pitch).

Hypothesis:

We think that this issue is related to the height of the blades for these reasons:

  1. The issue was fixed when we lowered all blades from the calibration block's "nominal" or zero by -1.5mm with all 4 blades roughly close to this number (avg -1.5mm)
  2. The issue came back when we attempted to fix the S-shaped M1 blade tip by correcting the extra swivel it needed to have in order to stay at the same height. (Joe recommendation to Betsy)
  3. Oli and Jeff have a d1 investigation in alog 76071 overlays different P to P model TFs when the blade heights are above/below their physical D (called FD in the attached plots).
    1. Interestingly, there is a new mode at roughly 1.9Hz when d is above the model's physical D by +-4mm. This mode is confirmed to not be cross coupling. Our recent TFs don't have them but TFs with the drift earlier do - I think this is a red herring.
    2. More clearly, the attached file shows overlays from different d1 sizes (Pitch).
  4. While the F1 blades are at an avg height of -1.5mm below nominal calibration block height, the spread between the individual blades is higher than before, with the problematic "soft/S" blade measuring at only -1mm. There's another blade at -1.8mm. This is the only difference between our current drifty -1.5mm avg and the non-drifty -1.5mm avg is the spread of each indiv. blade height. At this point, I'm interested in seeing how the spread of individual blades affects the drift effect in addition to just an everage d1 drop - could it be a combo of these effects? We can investigate the latter by playing with the model and the former by emperically measuring the drift itself.

Our Units:

Sensor Calibration Block Nominal: 0mm = 25.5mm using shims, drifty - what below measurements are based on
Config 1: -1.5mm avg = 24mm using shims, no drift
Config 2: -1.5mm avg = 24mm using shims, drifty. Only difference is that the spread of the individual blade tip heights is greater. Indiv blade heights: -1.6mm, -1.5mm, -1.0mm, -1.8mm.

We need to know how the calibration block converts to model parameters in d1 and whether that's effective or physical d1 in the model. Then we can stop using referential units.

To further investigate, we have questions:

  1. What is the "sensor calibration block" calibrated to? Physical D (Center of Mass to blade tip) or Effective D?  What are these values? We just want to find a model way to test parameters rather than the cal block or the shim methods to our model since right now we're going off potentially old information.
  2. Could differences between the 4 individual blades be causing a drift this stark? (i.e. it's not a net d1 height issue but a blade to blade height issue or a combo). I'm thinking this may be the case since we have two equal net heights (-1.5mm avg) with the only difference being the spread of the indiv. heights.

Some Early Observations (attempting to constrain our model to our measurements):

  1. TFs before and after the F1 drift manifested (now vs 7 days ago) barely change the actual peak locations, but that's expected due to nature of TFs (I think).
  2. The difference between -1mm and -3mm drastically changes the 1.05Hz peak's position. In general, small mm changes have noticeable decimal freq. changes.
  3. The shape of the model curve is different for -3mm and -5mm, having positive inflection. Anything higher has our straight/negative inflection shape.

Attachments:

F1Drift09052024: BOSEM Drift over the last 7 days. Notice that the F1 OSEM is the only one showing a drift. LF and RT show a diurnal temperature based change due to suspension sagging but this is unrelated.
F1DriftEuler09052024: BOSEM Euler Basis Drift over the last 7 days. Notice that only Pitch is showing the drift
F1DriftM2CountsEuler09052024: BOSEM Counts Drift in the M2 (PUM) Stage for both euler and direct. Notice that there is no percieveable drifting or pitching here. Disclaimer: The M2 Sat-amp box is old and has a transimpedance issue. I just got a spare and will switch it out when not on-shift.
triplemodelcomp_2024-08-30_2300_BBSS_M1toM1: Oli's TF model to measurement comparison with different physical d1 +- mm distances. Pitch here is the most important. We want to empically fit the model to the measurement but we do not yet know the absolute height of the calibration block in model terms.
allbbss_2024-jan05vJuly12Aug30_X1SUSBS_M1_ALL_ZOOMED_TFs: Oli's Drift v. No Drift v. Model Comparison. Oli is planning on posting an alog both with this information and the d1 distance comparisons once we ascertain calibration block absolute units.
Images attached to this report
Non-image files attached to this report
Comments related to this report
oli.patane@LIGO.ORG - 16:19, Saturday 07 September 2024 (79969)

Update to the triplemodelcomp_2024-08-30_2300_BBSS_M1toM1 file Ibrahim attached - there is an update to the legend. In that version I had the description for the July 12th measurement as 'New wire loop, d1=-1.5mm, no F1 drift', but there was actually F1 drift during that measurement - it had just started over a week before so the OSEM values weren't declining as fast as they had been earlier that week. I also want to be more specific as to what d1 means in that context, so in this updated version I changed July's d1 to be d1_indiv to hopefully better show that that value of -1.5mm is the same for each blade, whereas for the August measurements (now posted ) we have d1_net, because the blades heights differ by multiple .1 mms, but they still average out to the same -1.5mm.

Non-image files attached to this comment
H1 SQZ
victoriaa.xu@LIGO.ORG - posted 18:00, Thursday 05 September 2024 (79942)
SHG locking issue b/c demod RF Max threshold exceeded when shg unlocked

Naoki, Vicky -

Had an SHG relocking issue just now, when the squeezer briefly dropped lock at 2024 Sept 5 22:46:16 UTC, for the PMC to relock (its PZT bottomed out, routine issue).

SHG guardian went into a weird locking loophole which we had not seen before, summarized in screenshot. The SHG IR trans PD locking beatnote strength goes high when the SHG is unlocked, aka see the H1:SQZ-SHG_TRANS_RF24_DEMOD_RFMON signal. Its threshold is nominally at H1:SQZ-SHG_TRANS_RF24_DEMOD_RFMAX = 0. But the SHG_GRD has a hardfault state that brings guardian down if this threshold is exceeded, so GRD would try to LOCK, then see this error message for RF power level overload, then it would go DOWN, and its stuck.  See SHG guardian logs.

#FIXME: resolve this issue. Ideas- either remove this race condition from SHG guardian (send to IDLE if in fault?), changing RF threshold, etc.

To fix it this time, I manually changed the threshold H1:SQZ-SHG_TRANS_RF24_DEMOD_RFMAX = 5 (threshold was at 0, the demod beatnote was at 3.3), then brought SHG_GRD to LOCKED (worked fine), then reset threshold back H1:SQZ-SHG_TRANS_RF24_DEMOD_RFMAX = 0.

#TODO: decide whether this is a problem that needs fixing or just a weird one-off issue. Trending back, the RF demod power basically always goes high when unlocked, which often triggers this race condition. I'm not sure like 1) why was a problem this time, or 2)  why it is not a problem every time.

Images attached to this report
H1 ISC
elenna.capote@LIGO.ORG - posted 16:47, Thursday 05 September 2024 - last comment - 16:33, Tuesday 10 September 2024(79939)
DARM comparison, BRUCO results post-commissioning

We made some improvements today in the sensitivity, going from about 151 Mpc on GDS CLEAN to about 158 Mpc. However, our best range from April 11th (DARM FOM reference pre-OFI disaster) is around 165 Mpc. I made a comparison of that time and now with today's commissioning improvements to see where we are still missing range. I have attached the four plot results from the darm_integral_compare results (see alog 76935 for directions).

The range integrand plot makes it much easier to see that we are still missing sensitivity around the mid-frequency band. However, the sensitivity difference shows that we lose 5 Mpc of range by 40 Hz as well. Much of this range loss seems to come from a variety of peaks that have appeared since the OFI vent, such as the 20 Hz peak. We lose another ~3 Mpc between 40-200 Hz.

I ran a bruco with GDS CALIB STRAIN CLEAN on high range time after commissioning today: post-commissioning bruco

It looks like many of these new low frequency peaks (like the large 20 Hz peak) are well witnessed by things like PSL accelerometers, indicating that they could be from jitter: PEM-CS_ACC_PSL_TABLE1_Y_DQ

Generally, there is a lot of jitter coherence, and given that this is the CLEAN channel, that's probably a sign that the jitter cleaning could be improved, maybe making use of other witness channels if the current witnesses are insufficient to subtract the noise.

A peak at 30 Hz has some coherence with MAG sensor channels, here is one: PEM-CS_MAG_LVEA_VERTEX_X_DQ

Right around 35.4 Hz, there is a lot of coherence with various ISI HAM6 sensors and OMC ASC sensors. For example: ISI-HAM6_GS13INF_V1_IN1_DQ

There is also still a large amount of LSC REFL RIN coherence up to 1 kHz: LSC-REFL_RIN_DQ

I think we should test the PRCL offset again, especially because this will help reduce the CHARD Y noise coupling (ASC-CHARD_Y_OUT_DQ) and will also possibly help this HF noise (frequency noise? intensity noise?)

SRCL is better than before, but maybe has more room for improvement between 10-25 Hz: LSC-SRCL_OUT_DQ

DHARD Y coherence is low, but still present, so we should be careful with the WFS offset: ASC-DHARD_Y_OUT_DQ

There is still PRCL coherence: LSC-PRCL_OUT_DQ which is likely coupling through a combination of CHARD Y, SRCL, and LSC REFL RIN. Again a PRCL offset will help. Other strategies are to check POP phasing, POP sensing, etc. Reminder: PRCL feedforward failed, so we need to consider other avenues for noise reduction.

To summarize some strategies to get back to April sensitivity:

Editing because I went back to check the previous PRCL offset work and found this comment: 76818, in short, we can fix the REFL RIN coherence, but it has no effect on the sensitivity. However, it can improve CHARD Y noise, although at the time I don't think we were limited by CHARD Y enough to see the low frequency benefit.

Images attached to this report
Comments related to this report
derek.davis@LIGO.ORG - 11:29, Friday 06 September 2024 (79948)DetChar, DetChar-Request

Regarding the 20 Hz line, this line disappeared from DARM yesterday (Sept 5) from roughly 12:45 - 14:15 UTC. Matching Elenna's note about coherence with PSL environmental channels, the same line disappears from the PSL microphones and accelerometers at the same time. Furthermore, there are short time windows where this line dissapears from PSL channels. This behavoir happens roughly (not the exact same gap each time) at 2 hour intervals.

These clues may be helpful for any investigation into the source of this line.  

Images attached to this comment
elenna.capote@LIGO.ORG - 15:18, Friday 06 September 2024 (79953)

Another note about PRCL Offsets and CHARD Y:

I have attached a screenshot plot comparing the PRCL offset on/off times with the noise in CHARD Y (I used the on/off times from this April alog: 76814). The PRCL offset did reduce the noise in CHARD Y a small amount, and also reduced the CHARD Y coherence with DARM. I don't think at the time of this test we were limited by CHARD Y, so we didn't actually see a change in sensitivity from this test. Therefore, it's worth trying the offset again since we seem to have more CHARD Y noise coupling right now.

Images attached to this comment
elenna.capote@LIGO.ORG - 16:33, Tuesday 10 September 2024 (80029)

Here is a comparison of a longer-span time from April and from last night's lock. Using 2 hour blocks of no-glitch time I created these darm comparison plots.

There were further small improvements in the sensitivity from when these plots were last made, so they are not completely comparable to the plots in the original alog.

These plots indicate that we have actually gained some low frequency sensitivity since April, although we are definitely seeing more peaks around low frequency than before the emergency vent. We are still missing some range around 100 Hz.

Images attached to this comment
LHO General
corey.gray@LIGO.ORG - posted 16:29, Thursday 05 September 2024 (79912)
Thurs DAY Ops Summary

TITLE: 09/05 Day Shift: 1430-2330 UTC (0730-1630 PST), all times posted in UTC
STATE of H1: Observing at 147Mpc
INCOMING OPERATOR: Ibrahim
SHIFT SUMMARY:

The first half of the shift was devoted to calibration measurements + a little over 3hrs of commissioning time.  H1 then had a lockloss (after 16hrs & almost reaching 160Mpc).  45min into the next lock and have had range data point just under 158Mpc.
LOG:

LHO General
ibrahim.abouelfettouh@LIGO.ORG - posted 16:22, Thursday 05 September 2024 (79940)
OPS Eve Shift Start

TITLE: 09/05 Eve Shift: 2330-0500 UTC (1630-2200 PST), all times posted in UTC
STATE of H1: Observing at 147Mpc
OUTGOING OPERATOR: Corey
CURRENT ENVIRONMENT:
    SEI_ENV state: CALM
    Wind: 8mph Gusts, 3mph 3min avg
    Primary useism: 0.02 μm/s
    Secondary useism: 0.18 μm/s
QUICK SUMMARY:

IFO is in NLN and OBSERVING as of 22:46 UTC

H1 ISC
naoki.aritomi@LIGO.ORG - posted 16:01, Thursday 05 September 2024 (79938)
PI ETMY output filter change

This is a request from Vlad a long time ago. 

In 73697, Vlad changed the bandpass filter in H1:SUS-ETMX_PI_UPCONV_UC3_SIG to steeply cut off the lower sideband (80kHz-300Hz) for 80.3 kHz PI. The new filters are FM1 and 2 (80to81kHz_a and 80to81kHz_b).

Vlad asked me to implement a similar filter for other PIs. I changed the bandpass filter in H1:SUS-ETMY_PI_UPCONV_UC7_SIG for 10.4kHz PI. The new filters are FM4 and 5 (10to11kHz_a and 10to11kHz_b) and old filter is FM1.

The first and second attachments show the new and old bandpass filters. The new filter has -144dB gain for lower sideband (10kHz-430Hz), while the old filter has -40dB gain. The SDF is accepted.

Images attached to this report
H1 CAL (CAL)
corey.gray@LIGO.ORG - posted 15:35, Thursday 05 September 2024 (79928)
Meas #3: H1 Calibration Measurement Post-Commissioning Changes (broadband headless + simulines)

This is the 3rd calibration of the day.  The one taken post-commissioning was not usable/had error.  So received request to run another Calibration.

Measurement NOTES:

Images attached to this report
H1 AOS (DetChar)
mattia.emma@LIGO.ORG - posted 14:48, Thursday 05 September 2024 - last comment - 16:05, Thursday 19 September 2024(79936)
Cross-power spectral density code

-Mattia, Sheila

We have written a python script to compute the full matrix of power spectral densities and cross-power spectral densities between a given channel, i.e., DARM, and a set of auxiliary channels. The code can be find at this repository https://git.ligo.org/mattia.emma/cross_psd  which includes a README file describing how to run it.

The main arguments the user has to pass are the start time (in GPS time) and length of the data to retrieve from gwpy, a list of channel names and the starting frequency for the strain plots.

The code creates five different types of plots using the coherence and cross-power spectral density matrix. The final result of the code is a coefficient for each frequency value expressing the algebraic sum of the contributions of all the auxiliary channels to DARM considering the cross-power spectral density terms. It also computes the coherence between the single auxiliary channels and the DARM channel, which are the diagonal terms in the cross-power spectral density matrix.

The five kinds of plots are:

  1. The cumulative coherence. The sum of the coherence coefficients of the single auxiliary channels with DARM. As we add more and more channels to the sum, one can notice from the plot that the value of the cumulative coherence goes above one, which is unphysical. This motivates the inclusion of the cross-power spectral density terms to account for the correlation between the auxiliary channels.
  2. The cumulative strain contribution. Plot of the DARM strain and the iterative contribution of the selected set of channels to the strain. For example 3_<Channel_name> means that the strain contribution was computed using three auxiliary channels and the added channel compared to the previous plot (2_<Channel_name>) is <Channel_name>. This plot has only two lines.
  3. Strain_<number>.   Similar to 2 but with as many lines as in <number> plus the DARM strain to show how increasing the number of included channels saturates the DARM strain.
  4. Strain_comparison_<channel_name_1>_<channel_name_2>. Similar to 2 but including  the DARM strain and only two lines. One showing the cumulative contribution to the strain until <channel_name_1> and one adding to this <channel_name_2>.
  5. Single_coherence_<channel_name>. A plot of the coherence between the DARM channel and the <channel_name>.

All of these plots can also be created using as a main channel any auxiliary channel instead of DARM, e.g., if one would like to study the correlation between auxiliary channels. Each plot name also includes the start and end GPS time of the data used for them.

Comments are welcome. As a next step we would like to implement interactive plots to allow the user to include/exclude lines from the plots.

Images attached to this report
Comments related to this report
mattia.emma@LIGO.ORG - 16:05, Thursday 19 September 2024 (80192)DetChar

We have now added a code and instructions to the GitLab to obtain an interactive plot on one's local server.

The webpage displays two plots as shown in the attached screenshots (third and fourth image) and allows the user to select which lines to show through a checklist. It is possible to save a screenshot of each plot, zoom-in and out, and hover over the data.

The two included plots are (1) a plot of the normalized residuals between the DARM noise and the cumulative strain contribution of the auxiliary channels , and (2) "Plot 2" from the above aLog, showing the cumulative contribution of the selected channels to the DARM noise.

The code is publicly accessible on GitLab at Cross_psd .

Images attached to this comment
X1 SUS (SUS)
rahul.kumar@LIGO.ORG - posted 14:27, Thursday 05 September 2024 - last comment - 14:27, Thursday 05 September 2024(79923)
O5-HRTS status report.

Ryan C, Rahul

We have finished the assembly of the 10th Ham Relay Triple Suspension (HRTS) for O5, which is being assembled and characterized in the stagings clean room lab upstairs. In June we reported the assembly and testing of first five Freestanding HRTS suspension (see LHO alog 78574 and 78711), since then we have built an additional five of them, thus bringing the total count to ten for both the sites (with two more to go, total twelve required between LHO & LLO which includes one spare at each site).

I have attached several pictures (attachment01, attachment02, attachment03, attachment04) below which shows the assembled & locked HRTS stored in the lab on the flow bench in the clean room. Picture01 shows an HRTS with BOSEMs and cables attached, ready to be characterized on test stand (reference pic is shown here).

In this round of HRTS assembly work we have assembled three Freestanding configuration, one Suspended version (shown in the attachment05 below) and one OM0 (attachment06). The Suspended version of HRTS will be attached to the new BBSS (beam splitter) in O5 and Om0 will have bottom mass (optic) actuation using AOSEMS.The top mass will be controlled by 6 BOSEMs which is common for all types of HRTS.

After finishing the assembly work, we balanced all three stages of the suspensions for all six degrees of freedom. This involved lowering and matching  blade tip height and angle on the top stage (2 blade springs) and on the top mass (4 blade springs). In all the cases, optic's lowest edge was lowered to a height of 40.5mm (+-0.5mm) from the bottom of the cage. The PUM and Top Mass height was adjusted based on the scribe lines on the structure.

Given blow are the details (OLV, offsets and Gain) of the six BOSEMs attached the HRTS.

1. Structure no. 07, Configuration: Suspended

Suspended masses: Top Mass = 755gm, Penultimate mass = 802gm, Dummy optic = 300gm

BOSEMs s/n D060108-E. S1900741, S1900749, S1900622, S1900662, S1900637, S1900613.

OLV OFFSETS GAIN
30830 -15415 0.973078
27619 -13809.5 1.086209
25585 -12792.5 1.172562
24300 -12150 1.234568
26400 -13200 1.136364
26872 -13436 1.116404

2. Structure no. 06, Configuration: OM0

Suspended masses: Top Mass = 755gm, Penultimate mass = 802gm, Dummy optic = 301gm

BOSEMs s/n D060108-E. S1900726, S1900723, S1900746, S1900732, S1900742, S1900747

OLV OFFSETS GAIN
31111 -15555.5 0.964289
30571 -15285.5 0.981322
32384 -16192 0.926383
24964 -12482 1.20173
26685 -13342.5 1.124227
26905 -13452.5 1.115034

 

3. Structure no. 04, Configuration: Freestanding

Suspended masses: Top Mass = 758gm, Penultimate mass = 802gm, Dummy optic = 301gm

BOSEMs s/n D060108-E. S1900749, S1900722, S1900724, S1900735, S1900740, S1900744

OLV OFFSETS GAIN
30687 15343.5 0.977613
27768 13884 1.08038
28421 14210.5 1.055558
26807 13403.5 1.119111
26432 13216 1.134988
30319 15159.5 0.989479

4. Structure no. 05, Configuration: Freestanding

Suspended masses: Top Mass = 755gm, Penultimate mass = 803gm, Dummy optic = 300gm

BOSEMs s/n D060108-E. S1900730, S1900727, S1900750, S1900738, S1900743, S1900734

OLV OFFSETS GAIN
30534 -15267 0.982511
29900 -14950 1.003344
26531 -13265.5 1.130753
26624 -13312 1.126803
24670 -12335 1.216052
29626 -14813 1.012624

5. Structure no. 09, Configuration: Freestanding

Suspended masses: Top Mass = 758gm, Penultimate mass = 800gm, Dummy optic = 300gm

BOSEMs s/n D060108-E. S19007309 S1900725, S1900733, S1900736, S1900803, S1900728

OLV OFFSETS GAIN
31068 -15534 0.965624
30716 -15358 0.97669
27512 -13756 1.090433
25864 -12932 1.159913
26362 -13181 1.138002
32378 -16189 0.926555

********************************************

Note- The test results of the suspension will be posted below as comments.

Images attached to this report
Comments related to this report
rahul.kumar@LIGO.ORG - 13:57, Thursday 05 September 2024 (79931)

Test results for structure no. 07, Configuration:- Suspended

Attachment01 shows the transfer function results along with individual osem results, compared against the model

Attachment02 shows the top to top transfer function measurement results for all 6 dof and attachment03 is the zoomed in version of the same. The plots shows three measurements (taken on Aug 12, Aug 19 and Aug 21) after making mechanical changes to the suspension, which includes replacing the bottom wire loop to remove heaving pitch on the optic (caused due to faulty springs in the wire pulling jig). There is some low frequency (0.8Hz approx.) cross coupling in T dof from Yaw. V dof still has R coupling into it. The magnitude for R dof is slightly low when compared against the model. 
We have tried to fine tune the suspension to remove cross coupling and improve the TF magnitude, how it looks like we still need to do so some work over here to further refine the results.This work is still ongoing.

Non-image files attached to this comment
rahul.kumar@LIGO.ORG - 14:03, Thursday 05 September 2024 (79932)

Test results for structure no. 06, Configuration:- OM0

Attachment01 shows the transfer function results along with individual osem results, compared against the model

Attachment02 shows the top to top transfer function measurement results for all 6 dof and attachment03 is the zoomed in version of the same.

L, P, T and Y dof looks fine, although there is a slight frequency shift at Yaw. However the magnitude for R dof is slightly lower than the model and V dof has cross coupling from R which needs further work.

Non-image files attached to this comment
rahul.kumar@LIGO.ORG - 14:09, Thursday 05 September 2024 (79933)

Test results for structure no. 04, Configuration:- Freestanding

Attachment01 shows the transfer function results along with individual osem results, compared against the model.

Attachment02 shows the top to top transfer function measurement results for all 6 dof. Overall the suspension looks healthy. V and Rdof in this case has given us a lot of trouble and after a lot of fine tuning (of the suspended chain, bosems, flags etc) we have been able to bring the results as close as possible to the model. The black trace on V dof was measured with flags at an angle with respect to the PD/LED of the bosem, once corrected the magnitude improve as seen in pin and orange trace.

Non-image files attached to this comment
rahul.kumar@LIGO.ORG - 14:13, Thursday 05 September 2024 (79935)

Test results for structure no. 05, Configuration:- Freestanding

Attachment01 shows the transfer function results along with individual osem results, compared against the model

Attachment02 shows the top to top transfer function measurement results for all 6 dof and attachment03 is the zoomed in version of the same.

V and R dof needs some improvement which is currently ongoing. The rest of them looks healthy.

Non-image files attached to this comment
rahul.kumar@LIGO.ORG - 14:16, Thursday 05 September 2024 (79937)

Test results for structure no. 09, Configuration:- Freestanding

Attachment01 shows the transfer function results along with individual osem results, compared against the model

Attachment02 shows the top to top transfer function measurement results for all 6 dof and attachment03 is the zoomed in version of the same.

The suspension looks healthy and I am happy with the transfer function results. The cross coupling at Vdof (which is common to all the HRTS) needs some attention, which is currently ongoing.

Non-image files attached to this comment
H1 SUS
jim.warner@LIGO.ORG - posted 14:01, Thursday 05 September 2024 (79930)
B&K measurements of BBSS in staging

Betsy asked me to take a look at doing B&K measurements of the BBSS being assembled in the staging building, so I reminded myself how to use the B&K and took measurements this morning. I'll attach a photo shortly, but I put the accel on the very bottom of the cage, with +X axis aligned with optic longitudinal, Z aligned with is optic vertical, Y is optic transverse. Plots are titled with the accel axis that I hit on the suspension cage, while the legends are labeled with the accel axis response, so "BBSS X Meas" shows the X,Y,Z tf from hitting the cage along the accel X axis. These measurements are a kind of a mid point of the assembly, looks like most of the parts were there, but the bottom stage osems didn't have flags, I didn't see any vibration absorbers.

I think the most concerning thing I see is this 65-ish hz X mode on the first plot. It's the biggest peak and is in a band that could potentially really limit some of the ISI loop gains, if it's not well damped on the table.

A while ago I made a script to plot these measurements, but didn't explicitly say how to run it. Script is quick_plot.py is userapps/sys/h1/scripts/bruel_and_kjaer:

jim.warner@cdsws22:~ 0$ userapps
jim.warner@cdsws22:release 0$ cd sys/h1/scripts/bruel_and_kjaer/
jim.warner@cdsws22:bruel_and_kjaer 148$ ./quick_plot.py -t "BBSS Z Meas" -f "/path/to/data/BBSS_Z_meas.csv"
 

 

Images attached to this report
H1 SQZ
naoki.aritomi@LIGO.ORG - posted 13:12, Thursday 05 September 2024 - last comment - 11:45, Friday 20 September 2024(79929)
SRCL offset change from -175 to -290 and FC detuning improvement

Vicky, Sheila, Naoki

First we tried SRCL offset of -400, which looked good in yesterday's FIS SRCL offset measurement 79903. We took the calibration measurement with SRCL offset of -400 in 79911, but Louis reported in the mattermost that there is a large optical spring in the sensing function. Also, FDS with SRCL offset of -400 is worse than nominal. Vicky will add more plots for this.

Then we decided to change the SRCL offset to -290 and optimized FC detuning. This improved the sensitivity below 100 Hz as shown in the first attachment and improved the range by ~5Mpc. The optimal FC detuning changed from -34 Hz to -28 Hz and this could be because of SRCL offset change and arm power change.

After FC detuning improvement, we took the calibration measurement with SRCL offset of -290 in 79922, but the measurement did not make sense according to Louis so we took an another calibration measurement with SRCL offset of -290 in 79928

Images attached to this report
Comments related to this report
victoriaa.xu@LIGO.ORG - 16:03, Thursday 05 September 2024 (79934)

Following up with some FIS SRCL measurements from today as we were navigating how to best optimize SRCL offset for squeezing, which gives best sensitivity around 100 Hz.

Blue & purple traces - When first looking at SQZ after re-calibrating at -400 counts srcl offset, SQZ looked kinda v-shaped, like as if the SRCL detuning is big. We first tried optimizing the sqz angle for the bucket (blue, CLF RF6 demod phase @ 222 deg), then tried to optimize high-freq sqz (purple, CLF RF6 @ 215deg). For this SRCL offset at -400 counts, with about (222-215=) 7 degrees difference on the CLF RF6 demod phase (bad estimate is ~3.5deg diff on sqz angle), this changed the kHz squeezing level by about 1.9dB. See the trends on this screenshot.

Yellow trace - We then tried to see if FIS + SRCL @ -400 counts was the same as yesterday lho79903 and yes it was same. But zooming into yesterday's plots, it looks like this -400 SRCL offset setting (yesterday's blue trace) was actually not a great spot (already well passed zero detuning), as there is a little bit of ballooning between 100-200Hz that we did not notice yesterday.

Given that squeezing, and also calibration, saw that this SRCL offset @ -400 cts had a bad spring effect, we backed it off to -290 counts and took another cal meausrement. We chose -290 to be ~halfway between the -475 ct (pink) and -100 ct (black) settings  tried yesterday (see dtt). For -475 ct and -100 ct, we realized today that DARM between 250-500 Hz had about the same level of anti-sqz coupled in by the SRCL detuning. Unsure if this means they have the same physical detuning, this is something we will try out in quantum noise models to understand better.

Green trace - shows FIS + SRCL @ -290 counts. It is where we expected from yesterday. Leaving it here.

In summary, today we tried a few methods of "optimizing srcl detuning," to get it closer to 0, but also realized we need to think more carefully with quantum noise models like, what is the easiest / most sensitive metric for squeezing to see the srcl detuning.

  1. looked at mid-squeezing, where the high freq squeezing angle matches no squeezing. the hope was that at this angle, we are mostly seeing phase variations across the band, using no-sqz as the reference. -400 ct was noticeably less flat compared to no-sqz than -290 ct.
  2. while always maximizing 1 kHz squeezing, try to see if we can "flatten" darm in the 100s Hz band.  This was a kinda confusing to evaluate because QN in the bucket is a very marginal/small effect you have to squint closely to see. We tried to do this yesterday and only in hindsight noticed that -400 counts was not good in yesterday's plots. From models, we can look for what do we even want / expect for 0 detuning.
  3. while maximizing bucket ~350 Hz squeezing, try to see what is the best we can do for darm noise in the bucket.

We then moved onto FDS + SRCL @ -290 counts, and optimized the filter cavity detuning, as Naoki describes above.

Images attached to this comment
francisco.llamas@LIGO.ORG - 11:45, Friday 20 September 2024 (80210)

Adding plots of the sensing function. From these measurements, we see that the sensing function is also an indicator of bad/good SRCL offset. Additionally, *something* changed from Thursday to Saturday, as seen in the Saturday calibration measurement trace.

Figures (1) and (2) are the different sensing functions where the second figure ranges from 0-40 Hz. The uncertainties of each measutrement are plotted in figures (3) and (4), where figure (4) ranges from 0-40Hz.

Images attached to this comment
H1 ISC
elenna.capote@LIGO.ORG - posted 12:42, Thursday 05 September 2024 (79927)
AS WFS offset test - no appreciable change in sensitivity

This was a fast test right at the end of the commissioning period. I tried changing the offset on the AS WFS to see if that changes the low frequency sensitivity of DARM. Short answer: no change in sensitivity without the offset, and no improvement in sensitivity with a higher offset, which yesterday's tests suggested would help (79904).

I forgot to save the reference for the higher offset test (it was exactly the same as the others), but here is a comparison of the current offset (-0.15) and zero offset. The April 11 reference trace is also shown. We are very close to our best low frequency sensitivity in April (pre-OFI problems).

I think that if it helps the SQZ ASC to have no offset, we should turn this offset off. DHARD Y coherence is now very low even with the offset off.

Images attached to this report
LHO General
corey.gray@LIGO.ORG - posted 12:21, Thursday 05 September 2024 (79926)
Mid-Shift Status (Thurs)

Dropped out of OBSERVING at 1530utc (830amPT), for calibration measurements and then went immediately into Thurs COMMISSIONING time.  Commissioning ended 1917utc (1217pmPT).

H1 CDS
david.barker@LIGO.ORG - posted 12:18, Thursday 05 September 2024 (79925)
Added SENSMON2 CLEAN channel to IFO Range MEDM

Sheila, Dave:

On Sheila's request, I have edited the generate_ifo_range_medm.py script to add a new line for the H1:CDS-SENSMON2_BNS_EFF_RANGE_CLEAN_MPC channel (plus its associated GPS channel).

Images attached to this report
Displaying reports 6681-6700 of 84300.Go to page Start 331 332 333 334 335 336 337 338 339 End