H1 CDS (SYS)
david.barker@LIGO.ORG - posted 15:03, Monday 26 May 2014 (12078)
h1guardian0 machine out of memory, is swapping from disk

I just noticed that the h1guardian0 machine is in need of some attention. It currently is using all its RAM and is swapping from disk, so presumably it is now performance limited.

The memory usage started increasing around 17:30 PDT Thursday 22nd, and got steadily worse. Swapping started at 03:30 PDT Friday 23rd and has been doing so ever since then.

We will most probably reboot during tomorrow's maintenance.

controls@h1guardian0:~ 1$ free -g

             total       used       free     shared    buffers     cached

Mem:            11         11          0          0          0          0

-/+ buffers/cache:         11          0

Swap:           11          5          6

H1 CDS (DAQ)
david.barker@LIGO.ORG - posted 11:05, Monday 26 May 2014 (12077)
CDS model and DAQ restart report, Saturday and Sunday 24th and 25th May 2014

model restarts logged for Sat 24/May/2014
2014_05_24 06:44 h1fw0

model restarts logged for Sun 25/May/2014

Unexpected restart of h1fw0, no restarts reported for Sunday.

H1 ISC (CDS, SYS)
jeffrey.kissel@LIGO.ORG - posted 18:33, Saturday 24 May 2014 - last comment - 02:53, Sunday 25 May 2014(12074)
Y-Arm Locks Now...
J. Kissel, A. Staley

As suspected, the problem appears to be the 71 MHz local oscillator that the Y end. At the remote advice of Alexa, I increased the ALSY's "LO mon" value, H1:ALS-Y_REFL_A_DEMOD_LONOM, from 20 to 21. As soon as I did so, the arm locked up instantly, the demod error disappeared, and the guardian error message cleared. Even more strange, the monitor value, H1:ALS-Y_REFL_A_DEMOD_LOMON is still *above* 21, so the nominal must be a mean with a range not a threshold. Even more strange than that, if I decrease the nominal value back down to 20, the arm remains locked. DAH! I guess I have plenty more to learn on this system.

Anyways, the 71 MHz power supply still claims that its power supply voltages are too low, and its output monitor, H1:ISC-RF_Y_AMP71M_OUTPUTMON, says the power is 51 [dBm]. We should fix this (if its actually broken) on Tuesday. 

We should also put in some effort to making the guardian subsystem messages more clear.

For now I'll continue with the LO nominal set to 21 [??]. (Though I'm surprised that Stefan's state machine doesn't prevent me from doing this...)

Also, I attach the MEDM screen chain one has to follow to get to this information.
SITEMAP > ALS tab > ALS Overview > Y Arm PDH [little black words in a silver background box] > 71MHz RF Amp 

I'm leaving both the X and Y arm locked and well aligned. And will shoot for the moon again tomorrow.
Images attached to this report
Comments related to this report
sheila.dwyer@LIGO.ORG - 02:53, Sunday 25 May 2014 (12076)
Also if you hit the force button on the PDH screen it will ignore error messages
daniel.sigg@LIGO.ORG - 21:15, Saturday 24 May 2014 (12075)

Doesn't make a lot of sense to me. The PDH LO is driven the 24.4MHz source. The 71MHz is used by the VCO. It looks like the monitor cable is unplugged, or maybe the 71MHz source is down? Check the RF monitors of the VCO. Documentation actually exists. RF monitors are part of the Beckhoff system. The tolerance is ±1dBm. A 1dBm variation of the PDH LO shouldn't prevent the Y-arm from locking.

H1 ISC (CDS, SEI, SUS, SYS)
jeffrey.kissel@LIGO.ORG - posted 17:58, Saturday 24 May 2014 (12073)
Attempted to use the Y-ARM. Failed.
J. Kissel, L. Barsotti, D. Hoak

Hoping to make a measurement of the length actuation force coefficient for the ETMY ESD, we tried to lock the Y-Arm using ALS. We've failed, and we don't know why. Below I outline our debugging process, but it's really not that interesting since we never found a culprit. Our best guess is something wrong with in analog at the Y-End PDH demodulator's local oscillator, because 
    - when we request the Guardian to changed to "LOCKED_NO_SLOW," it immediately faults out with a rather unhelpful "PDH" error message.     
    - H1:ALS-Y_REFL_LOCK_ERROR_MSG on the PDH overview screen claims "demodulator"
    - DEMODs complain of an error message "LO power level out-of-range" for both the "REFL" and "SPARE," where the nominal values are 20 and 22 [??], respectively and the monitored values show ~ 21.2 and ~ -36.9 [??]. Dunno what units these are in. Maybe dBm?
    - Opening the 71 MHz RF AMP screen, there are errors shown "Output RF power level out-of-range" and "Power supply voltages out-of-range" with a nominal value of 20.5 [dBm], and a monitor value of 51.9 [dBm].

X-Arm remains happily locked, and even survived a the big earthquake that took out the Y-ARM. 

Merp.


- Found no light or flashes on ALS Y GIG-E camera monitoring the transmitted light.
- Found all Y-arm ISIs tripped (probably because of an earthquake -13 hours ago, but strange that it didn't affect X-arm. Did look that hard.)
- Found ISI subordinate Guardians not responsive because a ca.get request for the master switch had faulted out.
- Reloaded all sub-ordinate Guardians, restored them in managed mode
- Reset Y-arm ISI watchdogs. Erred out because it "filters are not in expected stated," or something like that.
- Reloaded manager, switched requested state to OFFLINE to start everyone over
- Reloaded subordinates again, set to managed, requested FULLY_ISOLATED, and things came up -- slowly, but surely -- included HEPI realignment.
- Found SUS ITMY PUM WD tripped, which forced Guardian to go to safe, with the master switch OFF, and therefore no alignment biases.
- Reset SUS ITMY WD, waited for guardian to turn everything back on. As soon as alignment sliders came on, we began to get transmission flashes on the GIG-E camera. 

Since flashes, we've gotten no where. As mentioned above, the ALSY Guardian immediately faults.
- Tried tweaking alignment, because we thought transmission flashes were below locking trigger threshold. Tweaked up alignment, got normalized transmission up past 1.0, still no dice.
- Looked at optical levers after ISIs settled, there's slightly higher motion than the X-ARM, but nothing outrageous -- at MOST 0.2 [urad]_{pkpk} in ITMY, but I think that's because the blend filter configuration is different between ETMY and ITMY chambers. 
- The state machine is preventing us from changing any of the PDH Board configurations, but we find
    - Both ALSY PDH inputs disabled -- maybe because Guardian's waiting for "PDH" to be OK?
    - Error point, H1:ALS-Y_REFL_ERR_INMON shows identically zero signal.
    - DEMODs complain of an error message "LO power level out-of-range" for both the "REFL" and "SPARE," where the nominal values are 20 and 22 [??], respectively and the monitored values show ~ 21.2 and ~ -36.9 [??]. Dunno what units these are in. Maybe dBm?
    - Opening the F AMP screen, there are errors shown "Output RF power level out-of-range" and "Power supply voltages out-of-range" with a nominal value of 20.5 [dBm], and a monitor value of 51.9 [dBm].
    - H1:ALS-Y_REFL_LOCK_ERROR_MSG on the PDH overview screen claims "demodulator"
    - Similarly (but I guess less important), there are some errors in the Phase-Frequency Discriminator spare (sign wrong, and LO out of range), but I think (a) the spares don't matter, and (b) the nominal values haven't been set.


#yakshaving
H1 CDS (DAQ)
david.barker@LIGO.ORG - posted 10:34, Saturday 24 May 2014 (12072)
CDS model and DAQ restart report, Friday 23rd May 2014

No restarts reported.

H1 ISC
keita.kawabe@LIGO.ORG - posted 19:55, Friday 23 May 2014 (12070)
Awesome green WFSX

(awesome compared to what we had in the past, but still only for 3 DOFs).

I started with H1:ALS-X_TR_A_LF_OUT of about 1.1, centered WFSs, engaged the servo, and it didn't work.

Then I manually aligned the arm well such that the transmission becomes 1.2-1.25, centered WFS, and it still didn't work. Since I wasn't sure if the cavity was well aligned when I measured everything before, I started from scratch.

I measured the demod phase, and the phase itself was not a disaster, but I've found that segments were totally imbalanced (I balanced them before). Fixed it such that the seg1 signal strength against length injection is matched to seg3, same thing for seg2/seg4.

Then I measured the sensing matrix again, inverted them, put them in the input matrix, and PIT DOFs started working (but YAW not).

After several rounds of enable WFSs, center WFSs, remeasure sensing matrix, I converged to a state where 2 PIT DOFs plus one YAW DOF that corresponds to PZT2 works wonderfully. Enabling 3DOFs would immediately bring the transmission up to 1.36 or so.

Lisa misaligned ETMX such that the transmission drops to 1.0-ish, we enabled the 3DOF WFS, and immediately the transmission recovered.

Don't know why the 4th DOF doesn't work but I'm leaving it as is. For now WFS is disabled, QPD centering is enabled. If you want to enable WFS, you first need to disable QPD centering by disabling the input or output of H1:ALS-X_QPD_A_PIT and such, as the WFS feedback is also added into the same PZT path and there's no convenient way to disable QPD while allowing WFS signal to be routed to PZT.

Images attached to this report
H1 SUS
arnaud.pele@LIGO.ORG - posted 19:37, Friday 23 May 2014 (12067)
SR3 tfs results

H1 SR3 in chamber (HAM5 locked) undamped transfer functions for the three stages were measured yesterday night and are attached below. Overall they look good. Damped transfer functions are currently running.

Attachments in order :

1) M1-M1 undamped tfs compared with the model
Clean tfs, excellent match with the model.

2) M2-M2 undamped tfs compared with the model
Data is noisy, which is probably as good as we can get for now.
Pitch seems to couple with the first top mass vertical mode at 1.06Hz, yaw seems to couple with the second top mass roll mode @1.97Hz. Those coupling should be reduced with damping. 

3) M3-M3 undamped tfs compared with the model

Data is noisy, but gives a good idea of the tf shape. The only odd thing in the results was the factor of 4ish discrepancy between the model and the measurement for the pitch dof (meas=4ish*model). After spending some time trying to understand, it appeared to be a wrong euler to osem basis matrix. The pitch to osems factor (8.3) was 4ish times higher than the nominal value (2.4) (from make_sushlts_projections.m under HLTS/Common/MatlabTools/). Screenshot attached shows the corrected matrix.

I doubled check for PR3, which was also wrong. The new values were saved under a safe.snap for both suspensions and commited under the svn.

Images attached to this report
Non-image files attached to this report
H1 ISC
daniel.sigg@LIGO.ORG - posted 19:26, Friday 23 May 2014 (12069)
Y-arm bi-stable green lock

Not sure I saw this reported before. Today, I tried to align the y-arm. When I hit a certain angle in TMS, ETM or ITM, pitch or yaw, the lock would go bi-stable. When moving even further, it would stay at the lower value. However, the higher value could be regained by adjusting the PDH demodulator phase. As a matter of fact a phase change of ~20º can be used to switch between the states (see attached plot). Looking at the transmitted camera both modes look like 00.

Images attached to this report
LHO General
corey.gray@LIGO.ORG - posted 16:18, Friday 23 May 2014 (12050)
Ops DAY Summary

Day's Activities

H1 PSL (PSL)
corey.gray@LIGO.ORG - posted 16:15, Friday 23 May 2014 (12065)
PSL Diode Chiller Low Flow TRIP

This afternoon the following items tripped/went down: 

After much head-scratching, ultimately pointed our focus to the PSL (the PSL was completely down, no light coming from the PSL, Gerardo noted an Error on the Diode Chiller).  Luckily Rick was here and was already on his way up to the OSB.  Justin & I accompanied him to the Chiller & Diode Room. 

[(1)Before heading to Diode Room, we turned the ISS AutoLocker OFF.  (2)When heading to Diode Room, Kissel took the IMC Guardian to DOWN]

In the Chiller room, we noticed an Error light and message on the Diode Chiller (the one on the top which has a clear spout on it); the water in the spout wasn't moving much--it's generally more turbulent.  We couldn't clear the error at the Chiller, so we garbed up & went into adjacent Diode Room.

Here we had the Beckhoff computer to work with.  On the System Status screen we saw the following Trips (in red):

We hit a RESET here, but the Diode Chiller Flow was still tripped.  We then went to the Chiller screen & clicked on the RED Chiller button to bring it back.  We also clicked on the red Watchdog button.  At this point we were GREEN, and done in the Diode Room.  On the Diode Chiller the Error light was OFF (but we still saw the Error message on the LCD screen).

When we walked back into the Control Room everything was good, green, & we had PSL light.  The ISS Diffracted Power Was a little low, so we clicked it more positive (i.e. made absolute value of voltage a coule hundredths smaller.].

[when we had PSL light, Kissel requested "LOCKED" for IMC Guardian]

H1 ISC (ISC)
keita.kawabe@LIGO.ORG - posted 16:13, Friday 23 May 2014 (12063)
LHO arm drifts to compare with LLO

Lisa

 

At Livingston they have to realign the arms very frequently in order to mantain high power build up. It seemed like we were not seeing the same problem here, but we didn't really have any numbers for Valera.

So, I left both arms locked on green last night. The plot shows a 6 hours trend of the green transmission power for both arms, and amplitudes of the beat notes. The guardian was left on, and it was automatically recovering lock.

The Y arm power dropped by ~10-15% over 6 hours. For whatever reason X was drifting much more than Y. Still, on a 1 hour timescale, you can't really see any significant drift; over 6 hours, the X arm drift was ~50%. I don't know if it has been already observed in the past that X drifts more than Y, or if it was just an isolated event.

Images attached to this report
H1 CDS
cyrus.reed@LIGO.ORG - posted 15:47, Friday 23 May 2014 - last comment - 15:54, Friday 23 May 2014(12062)
Control Room Display Computers

I've upgraded the memory in all of the wall display computers in the control room from the woefully inadequate 2GB, up to 8GB.  This should make them run much better and prevent swapping and the general malaise that makes things quit working or otherwise grind to a halt on them after a while.

Comments related to this report
cyrus.reed@LIGO.ORG - 15:54, Friday 23 May 2014 (12064)

(These are hosts video0-6 and projector0.)

H1 TCS
david.hosken@LIGO.ORG - posted 15:32, Friday 23 May 2014 (12061)
TCS progress
TCSY:
- continued with CO2 beam alignment... transmitted beam through the second beam splitter (1% pickoff) is now aligned to the two quad thermopile position sensors.
- temperature sensors run to the water cooled beam dump, AOM driver and cooling water manifold. Tested and appear to be operational. Once the clamps are received back from LLO these can be fixed in position.
- AOM driver power cable re-routed

TCSX:
- CO2 laser turned off at 2130 UTC
- chiller and power supplies for both TCSX and TCSY were turned off at 2135 UTC
- FLIR camera/screen cover removed. Camera front face to screen distance is 8" (rather than the 13" on the design). Photo attached. 

TCS install checklist was also updated.
Images attached to this report
H1 SUS
arnaud.pele@LIGO.ORG - posted 15:16, Friday 23 May 2014 - last comment - 10:32, Saturday 24 May 2014(12059)
IOP WD still looking at osem DC values

After the PSL went down, MC2 IOP watchdogs tripped this afternoon, which cascaded to HAM2/HAM3 ISIs.

It tripped because of a large ISC length control offset signal applied on the left and right osems of the top mass.

Similarly as what Jeff did on the sus WD models (cf his alog), the trigger on DC osem values in the iop models (upper path of screenshot) should be removed to avoid this kind of situations.

This could be done during the vent period in two weeks. 

Images attached to this report
Comments related to this report
david.barker@LIGO.ORG - 10:32, Saturday 24 May 2014 (12071)

The vent period would be an excellent time for me to upgrade the IOP models to the targeted SUS/SEI watchdog system. In that system the DC component of the OSEMs is only monitored.

LHO VE (VE)
gerardo.moreno@LIGO.ORG - posted 12:33, Friday 23 May 2014 - last comment - 16:51, Friday 23 May 2014(12055)
Turned On then OFF the Mid Y PT-246B Cold Cathode

Reading before turning it off, 1.34X10-04 torr.

Left the CC on for 1.5 hours.

It is off now.

Comments related to this report
gerardo.moreno@LIGO.ORG - 16:51, Friday 23 May 2014 (12066)VE

Turned it ON again this afternoon, 4:03 pm, until 4:45 pm, CC is off now and it will remain off for the long weekend.

Pressure reading, 1.47X10-04  torr.

H1 General
greg.grabeel@LIGO.ORG - posted 11:07, Friday 23 May 2014 - last comment - 15:21, Friday 23 May 2014(12052)
LTS
The long term storage Nitrogen purge system has started testing today. It will be venting through a regulator and hose near HAM12 over the weekend. This purging shouldn't have an impact on any activities inside the LVEA. CP2 levels may need increased attention until we can see the impact that the purge line has on the LN2 dewar.
Images attached to this report
Comments related to this report
greg.grabeel@LIGO.ORG - 15:21, Friday 23 May 2014 (12060)
After the Nitrogen gas has had an opportunity to flow for a couple of hours the initial signs are looking good. The dewpoint is < -40° tdC and the pressure drop from the CP2 dewar to the end of the line pressure regulator looks to be < 1psi. I added a flow meter to the exhaust of CP2 and it looks like most of the boil-off is being redirected. Everything is looking good to start a test next week and check the overall cleanliness.
Images attached to this comment
H1 ISC
kiwamu.izumi@LIGO.ORG - posted 23:55, Thursday 22 May 2014 - last comment - 18:39, Friday 23 May 2014(12040)
Low arm biuldup was due to misalignment in Y arm

This evening Lisa pointed out that the low carrier buildup can be explained by misalignment in the Y arm.

I spent an hour to carefully adjust the alignment. Indeed, after the alignment, I got a cavity flash of 45 (normalized for a single arm build up) which is the highest we ever obtained. Also, the funny REFL9I offset disappeared and I could see a PDH-looking signal there when CARM passed through a resonance.

What I did:

Comments related to this report
kiwamu.izumi@LIGO.ORG - 00:09, Friday 23 May 2014 (12041)

Also in the afternonn I did a simple, brief chek for the demod phase of all the REFL 1f PDs.

I swept the X arm through a resonance by using ALS comm and monitored the PDH signals. It seems that everyone is adjusted somewhat.

=== settings ===

REFL9 = 84.9 deg

REFL45 = 19.2 deg

REFLAIR9 = 90 deg

REFLAIR45 = 147.6 deg

The whitening gain for all the PDs was set to the maximum i.e. 45 dB in this measurement.

Images attached to this comment
lisa.barsotti@LIGO.ORG - 18:39, Friday 23 May 2014 (12068)

This is a summary of last week of locking work, for posterity.

https://dcc.ligo.org/LIGO-G1400576