Displaying reports 72461-72480 of 84167.Go to page Start 3620 3621 3622 3623 3624 3625 3626 3627 3628 End
Reports until 15:16, Friday 23 May 2014
H1 SUS
arnaud.pele@LIGO.ORG - posted 15:16, Friday 23 May 2014 - last comment - 10:32, Saturday 24 May 2014(12059)
IOP WD still looking at osem DC values

After the PSL went down, MC2 IOP watchdogs tripped this afternoon, which cascaded to HAM2/HAM3 ISIs.

It tripped because of a large ISC length control offset signal applied on the left and right osems of the top mass.

Similarly as what Jeff did on the sus WD models (cf his alog), the trigger on DC osem values in the iop models (upper path of screenshot) should be removed to avoid this kind of situations.

This could be done during the vent period in two weeks. 

Images attached to this report
Comments related to this report
david.barker@LIGO.ORG - 10:32, Saturday 24 May 2014 (12071)

The vent period would be an excellent time for me to upgrade the IOP models to the targeted SUS/SEI watchdog system. In that system the DC component of the OSEMs is only monitored.

H1 SUS
arnaud.pele@LIGO.ORG - posted 14:40, Friday 23 May 2014 (12058)
Guardian error on ISIs

[Justin Corey Arnaud]
Even though the ISIs/HEPI were working fine, guardian has been reporting errors on ST1 and ST2 of each bsc chambers, cf screenshot. After reloading all of them, guardian is not reporting errors any more.

Images attached to this report
H1 CDS
cyrus.reed@LIGO.ORG - posted 14:04, Friday 23 May 2014 (12057)
ligo.org Authentication Failure

Authentication for ligo.org accounts in the control room started to fail at about 1:40PM (or at least that was when it was first reported).  I followed it as far as cdsldap0 logs stating slapd couldn't contact the remote server; rock.ligo-wa.caltech.edu was not pingable.  So I called Jonathan and he was able to walk me through reconfiguring slapd to use the alternate server, quartz.ligo-wa.caltech.edu which is still up and reachable.  ligo.org logins should now be functional in the control room again - Jonathan will investigate further remotely later in the day.

H1 CDS
cyrus.reed@LIGO.ORG - posted 13:21, Friday 23 May 2014 (12056)
LVEA CDS Workstations

I've swapped out the workstations located by the test stands, they were no longer useable as configured.  The new workstations, lveaws1,2 are iMacs and connect via the wireless AP.

LHO VE (VE)
gerardo.moreno@LIGO.ORG - posted 12:33, Friday 23 May 2014 - last comment - 16:51, Friday 23 May 2014(12055)
Turned On then OFF the Mid Y PT-246B Cold Cathode

Reading before turning it off, 1.34X10-04 torr.

Left the CC on for 1.5 hours.

It is off now.

Comments related to this report
gerardo.moreno@LIGO.ORG - 16:51, Friday 23 May 2014 (12066)VE

Turned it ON again this afternoon, 4:03 pm, until 4:45 pm, CC is off now and it will remain off for the long weekend.

Pressure reading, 1.47X10-04  torr.

H1 PSL (PSL)
corey.gray@LIGO.ORG - posted 12:06, Friday 23 May 2014 - last comment - 11:55, Tuesday 27 May 2014(12053)
ISS Oscillations (& Maybe Fixed?)

(Corey, Gerardo, Patrick)

Two days ago (about 4am Thurs morning) the ISS diffracted power started to drift down from about 6.7% down to 2.0%.  Once at 2%, it started to go into oscillations (roughly around 3am this morning); see attached 2-day trend.

Without instructions on how to address this (and no recent alogs noting this behavior), we scratched our heads a bit, moved some gains and hit buttons to no effect.  We returned back to the original state.  Then Patrick suggested we try switching from PD A to PD B, and this appeared to stop the oscillations.  It took us to a value of about 5%.  Unfortunately, it looks like the power is still sloping down however.  (Curious to see if the ISS goes back into oscillations at 9pm tonight).

Non-image files attached to this report
Comments related to this report
corey.gray@LIGO.ORG - 11:55, Tuesday 27 May 2014 (12086)PSL

Actually switching PDs was not the way to go here; we generally want to stay with PD-A. 

So here, you want to adjust the REFSIGNAL (H1:PSL-ISS_REFSIGNAL) channel in 0.01 amounts.  With Rick on the phone, I went from -1.63 to -1.55.  This stablized the Diffracted Power and took it from ~2% up to ~10%.  

H1 CDS
james.batch@LIGO.ORG - posted 12:03, Friday 23 May 2014 (12054)
Cleared testpoints on h1lsc model
After checking with commissioners to verify no one was performing any measurements on h1lsc, I manually cleared the test point list to avoid overloading the awgtpman process.  Test points had apparently been orphaned at some point, corresponding to the following channels:

H1:LSC-REFLAIR_A_RF45_I_ERR_DQ
H1:LSC-REFLAIR_A_RF45_Q_ERR_DQ
H1:LSC-REFLAIR_B_RF135_I_ERR_DQ
H1:LSC-REFLAIR_B_RF135_Q_ERR_DQ
H1:LSC-PRCL_EXC
H1 General
greg.grabeel@LIGO.ORG - posted 11:07, Friday 23 May 2014 - last comment - 15:21, Friday 23 May 2014(12052)
LTS
The long term storage Nitrogen purge system has started testing today. It will be venting through a regulator and hose near HAM12 over the weekend. This purging shouldn't have an impact on any activities inside the LVEA. CP2 levels may need increased attention until we can see the impact that the purge line has on the LN2 dewar.
Images attached to this report
Comments related to this report
greg.grabeel@LIGO.ORG - 15:21, Friday 23 May 2014 (12060)
After the Nitrogen gas has had an opportunity to flow for a couple of hours the initial signs are looking good. The dewpoint is < -40° tdC and the pressure drop from the CP2 dewar to the end of the line pressure regulator looks to be < 1psi. I added a flow meter to the exhaust of CP2 and it looks like most of the boil-off is being redirected. Everything is looking good to start a test next week and check the overall cleanliness.
Images attached to this comment
H1 CDS (VE)
david.barker@LIGO.ORG - posted 08:38, Friday 23 May 2014 (12047)
New EPICS alarms to cell phone alerting system running

Yesterday I started my new EPICS alarms alerting system with a full configuration. It monitors critical EPICS channels and sends text alerts to engineering staff (cell phone texts and regular email). This system is monitoring vacuum, fmcs and DAQ channels at a very low rate (once per minute). I do not anticipate any problems at the IOC end.

LHO General
corey.gray@LIGO.ORG - posted 08:34, Friday 23 May 2014 (12046)
Morning Installation Meeting Minutes

 

H1 CDS (AOS)
david.barker@LIGO.ORG - posted 08:29, Friday 23 May 2014 (12045)
TCS thermal camera testing

Yesterday I installed Windows 7 pro on a TCS FLIR thermal camera readout computer as a test in the CUR (cpu was installed on the GC network). Thomas provided two TCS FLIR cameras, which I attached to the second ethernet port of the computer via a 100BaseT switched hub. I ran the cameras at a low frame rate because I did not have GigE speeds for this test. Running the FLIR provided camera monitor software, I was able to view both cameras from one computer, which was the main purpose of the test. We do need to label the images if that is possible to differentiate between X and Y arm.

I noticed that one camera was not auto-focusing, Thomas is investigating.

H1 SEI
hugh.radkins@LIGO.ORG - posted 08:24, Friday 23 May 2014 (12044)
WHAM4 HEPI Off Stops & Floating
Entered the LVEA at 0745pdt and left 0805--No issues, will now attempt to close position loops.
H1 CDS (DAQ)
david.barker@LIGO.ORG - posted 08:23, Friday 23 May 2014 (12043)
CDS model and DAQ restart report, Thursday 22nd May 2014

model restarts logged for Thu 22/May/2014
2014_05_22 15:27 h1fw1

unexpected restart of h1fw1.

H1 ISC
kiwamu.izumi@LIGO.ORG - posted 23:55, Thursday 22 May 2014 - last comment - 18:39, Friday 23 May 2014(12040)
Low arm biuldup was due to misalignment in Y arm

This evening Lisa pointed out that the low carrier buildup can be explained by misalignment in the Y arm.

I spent an hour to carefully adjust the alignment. Indeed, after the alignment, I got a cavity flash of 45 (normalized for a single arm build up) which is the highest we ever obtained. Also, the funny REFL9I offset disappeared and I could see a PDH-looking signal there when CARM passed through a resonance.

What I did:

Comments related to this report
kiwamu.izumi@LIGO.ORG - 00:09, Friday 23 May 2014 (12041)

Also in the afternonn I did a simple, brief chek for the demod phase of all the REFL 1f PDs.

I swept the X arm through a resonance by using ALS comm and monitored the PDH signals. It seems that everyone is adjusted somewhat.

=== settings ===

REFL9 = 84.9 deg

REFL45 = 19.2 deg

REFLAIR9 = 90 deg

REFLAIR45 = 147.6 deg

The whitening gain for all the PDs was set to the maximum i.e. 45 dB in this measurement.

Images attached to this comment
lisa.barsotti@LIGO.ORG - 18:39, Friday 23 May 2014 (12068)

This is a summary of last week of locking work, for posterity.

https://dcc.ligo.org/LIGO-G1400576

H1 SYS (ISC, SEI)
jameson.rollins@LIGO.ORG - posted 23:34, Thursday 22 May 2014 - last comment - 06:27, Friday 23 May 2014(12035)
Locking activity tripping SEI watchdogs

This is really the next big watchdog issue: regular IFO commissioning activity is causing the SEI watchdogs to trip.  We need to investigate the issue further, but what we definitely know is that when we lose the ALS locks the ETM ISI watchdogs trip.  It's usually just in stage 2 actuators, but also sometimes both ISI stages and more than just the actuators.  This is reducing efficiency during commissioning, so we need to back off on the saturation count for the SEI watchdogs some more.

Comments related to this report
sebastien.biscans@LIGO.ORG - 06:27, Friday 23 May 2014 (12042)

Do you know why the SUS watchdogs don't trip before the ISI watchdogs? I would imagine that the transient sent when we lose the lock would trip SUS first.

H1 SUS
arnaud.pele@LIGO.ORG - posted 20:16, Thursday 22 May 2014 - last comment - 09:12, Friday 23 May 2014(12039)
SR3 TFs running overnight

SR3 measurements will be running overnight on opsws1.

Guardian states "undamping/undamped" were added to sus.py. It basically set the correct switches for testing purposes (undamped tfs). This state can be called from matlab before running a TF using (e.g for SR3):

system('caput H1:GRD-SUS_SR3_REQUEST UNDAMPED')

Only SR3 guardian was restarted

Images attached to this report
Comments related to this report
arnaud.pele@LIGO.ORG - 09:12, Friday 23 May 2014 (12049)

Measurements still running this morning

H1 ISC
keita.kawabe@LIGO.ORG - posted 15:10, Thursday 22 May 2014 - last comment - 10:18, Friday 23 May 2014(12024)
EX Green WFS again

Daniel and I restarted green WFS effort.

WFSA and WFSB were rephased using an injection into PDH CM board. Apparently somebody tried to compensate the signal differences across the quadrants when doing a similar injection as mine, and I followed that same path such that seg1 and seg3 are matched as well as seg2 and seg4.

Then I dithered PZTs at 2, 8, 11 and 13.5Hz to measure the sensing matrix, inverted the matrix, and put them in the input matrix, such that WFS_DOF3 becomes PZT1 and DOF4 PZT2. Note that both WFSs are much more sensitive to PZT2 than PZT1.

I didn't put any filter in DOF3/4 nor IP PITOFS and IP YAWOFS, but set the gain to some negative numbers.

In the input matrix of QPD alignment servo, I added a straight-through matrix to add the WFS signal.

I had a hard time working with state definition thing and maybe the guardian, so I still don't know if it works or not, but the intent is to do a high BW feedback to the PZT.

Images attached to this report
Comments related to this report
daniel.sigg@LIGO.ORG - 10:18, Friday 23 May 2014 (12051)

This was due to the guardian still containing old WFS code. I removed the offending lines from the python script. Then, I reloaded the guardian. Unfortunately, I missed adding a pass statement in a hanging if clause, which caused the guardian to commit suicide. Unfortunately, the guardian took the restart button with it. No guardian, no restart button, ???

H1 SYS
corey.gray@LIGO.ORG - posted 21:33, Wednesday 23 April 2014 - last comment - 08:56, Friday 23 May 2014(11552)
Camera Housings Installed On ITMx Cryo Baffle Spool

While the Gate Valves were closed and we were Laser Safe, I installed a pair of aLIGO Camera Housings on the Spool where the ITMx cameras will be. 

Comments related to this report
corey.gray@LIGO.ORG - 08:56, Friday 23 May 2014 (12048)

Additional Notes: 

Lexan covers were already installed on these viewports.

Checked out unused viewports:  VP1 & VP4 (see attached map).  Line of sight looks good for both of these viewports.  I installed camera housings and kept them on both of these viewports. 

Currently VP5 has the sole ITM camera.

Pictures of this work are located here.

Images attached to this comment