Displaying reports 72501-72520 of 84133.Go to page Start 3622 3623 3624 3625 3626 3627 3628 3629 3630 End
Reports until 10:42, Tuesday 20 May 2014
H1 ISC
corey.gray@LIGO.ORG - posted 10:42, Tuesday 20 May 2014 (11985)
Replaced Cable For ISCT1 Lights

Thought the issue was a bad switch, but it was actually one of the cables.  I swapped this cable out (which wasn't easy since it was hard to see where the cable connector needed to go [& these connectors suck!]). 

LHO General (CDS, PEM)
patrick.thomas@LIGO.ORG - posted 10:27, Tuesday 20 May 2014 (11984)
dust monitor code updated to 1.3.0
This completes WP 4633.

This was done to communicate with the MetOne model 6000 installed in the H1 PSL diode room.

The h0dustdr, h0dustex, h0dustey, h0dustlab, h0dustlvea, h0dustmx and h0dustmy target directories in /ligo/lho/h0/target were copied to /ligo/lho/h0/target_archive and updated. The h0dustex, h0dustey, h0dustlvea and h0dustlab IOCs were restarted and burtrestored to the snapshot files in /ligo/cds/lho/h0/burt/2014/05/19/08:00.

The h0dustdr IOC was started. The settings were changed to:
Sample Time: 20 seconds
Hold Time: 300 seconds
0.3 micron minor alarm: 100
0.3 micron major alarm: 200
0.5 micron minor alarm: 100
0.5 micron major alarm: 200
LHO VE
john.worden@LIGO.ORG - posted 10:20, Tuesday 20 May 2014 (11983)
MID Y vacuum PT246

Gerardo and I pumped out the dead space around PT246 and closed the valves to their prior state.

LHO General
justin.bergman@LIGO.ORG - posted 09:18, Tuesday 20 May 2014 (11980)
notes from tuesday morning meeting

SRM looking good; Betsy plans to do final check and hand off to OFI today

Apollo will be craning OFI over beam tube

Gerardo s. closing GV5/GV7 in anticipation of craning

HAM4 ISI floating, HEPI locked

McCarthy and Fil pulling cables at HAM5/6

Dan Hoak/Corey working on SLED buildup for HAM6

TCS calibrating CO2Y, troubleshooting interlock system CO2X

laser hazard expected ~1400

Corey swapping light in ISCT1 and manhandling things with Bubba in the squeezer bay

control room tour expected 1230-1300

King Soft expected

 

H1 CDS (DAQ)
david.barker@LIGO.ORG - posted 08:51, Tuesday 20 May 2014 (11979)
CDS model and DAQ restart report, Monday 19th May 2014

No restarts reported.

H1 ISC
lisa.barsotti@LIGO.ORG - posted 01:16, Tuesday 20 May 2014 (11978)
3f + dual arm: understanding our pain

Kiwamu, Stefan, Lisa

After talking with our LLO locking friends, spending some more time trying to further reduce the CARM offset, and thanks to the fact that tonight everything else was working fine, we think we know why our CARM offset reduction is so painful.

At LLO, the transition to 3f signals can be done with a very large offset (~ 3kHz), and once the transition to 3f signals is done, there is no particular issue in reducing the CARM offset down; no adjustments are done in the DRMI control.

Here, first of all we can transition to 3f signals for PRMI only after having passed the 18 MHz resonance in the arms (~970 Hz). This implies using the REFL 45 I&Q signal down to 700-800 Hz, which can be done only by tuning the demod phase on-the-fly .

Second, once on 3f, without constantly tuning the MICH loop (gain, offset, demod phase), we can't keep the PRMI locked while reducing the CARM offset.

We realized that the problem is that here we are using REFL 27 Q for controlling MICH, instead of REFL 135 Q. This is bad because REFL 27 Q is much more sensitive to the CARM offset, and offset and gain changes for this signal are indeed predicted by Kiwamu and Anamaria's simulation (though we don't have on hand plots for the exact CARM offsets we are currently at; Kiwamu is in the process of producing more plots).

The reason why historically REFL 135 Q was not used here is that there was essentially no signal. By comparing the LLO parameters with the ones we are currently using, it looks like we should increase the modulation index by at least a factor 2 and increase the light on the BBPD.

On the other hand, once we realized what was going on, we could reduce the CARM offset down to 250 Hz, by keeping the MICH loop happy monitoring offset, gain, and demod phase, and adjust all these parameters by hand. We could probably keep going, but there is no much point in doing that if we believe that we are just making our life harder by using a hostile signal.

Here is the roadmap to reach 250 Hz:


CARM OFFSET / MICH OFFSET
700 Hz / +200 cts
600 Hz / +400 cts
550 Hz / +800 cts
400 Hz / +900 cts
350 Hz / +900 cts
250 Hz / +1300 cts (PRCL offset -1000 cts)
MICH GAIN = 2
PRCL GAIN = 1.5


Other changes we did tonight:
    1.    Stefan relaigned the full IFO (X arm green, X arm red, TMSY single shot to beat note, Y arm green, PRMI)
    2.    We added a notch in the PRCL loop for the 70 Hz periscope resonance
    3.    We realized that theTMSY YAW damping loop has been off since May 15.. we re-closed the damping..
    4.    We modified the ALS slow path to include a 40 dB 5 second ramp for smooth engaging
    5.    We re-commissioned the Y arm ITM dither alingment loops, 1 dof only, in PITCH and YAW (the PZT loops are broken for both arms since the WFS software upgrade)

H1 PEM
kiwamu.izumi@LIGO.ORG - posted 18:48, Monday 19 May 2014 (11977)
ISS reference offset readjusted

ISS was in a state where he tries to engage the loop but keeps failing. So I re-adjusted the reference DC signal to -1.631. It fixed the issue. The diffracted power is now at 8-ish percent. Good.

Hope this will help our locking activity tonight.

H1 TCS
thomas.vo@LIGO.ORG - posted 16:59, Monday 19 May 2014 (11973)
TCS Progress
CO2X:
- Turned on laser at 10:00 AM PT, mysteriously turned off around 3:24 PM PT.  Still investigating causes, but we opened up the table and didn't see any problems.  We're leaving this on overnight tonight.

CO2Y:
- Calibrate the on table power meter.
- We're not leaving the laser on tonight, but we are leaving the chiller and the power supply on.

HWS HAM4:
- Aligned part of the X side on the in air table
- Retrieved spare in-vac temperature sensor for install by SUS

RHs:
- We wanted to commission the ITMX ring heater today without bothering the integration team.  Since the time constant of the ring heaters is on the order of many hours, quick impulses of very small powers (1-4 Watts for 1 or 2 seconds) we figured that it wouldn't be a problem.  We left the ITMY ring heater alone because it is actively being used to lock the PRMI so we focused solely on ITMX.

Complication: We saw some problems with the ITMX RH.  First off, the power we request gets translated into a current request which should match pretty closely to the current measured.  When we request 3.5 Watts, we expect to get .29 Amps and 12.0 Volts but we get .14 Amps and 6.00 Volts with an output wattage of .8 Watts. Not good.  Then we noticed that turning on the upper segment of the RH affected the read back on the lower segment.  This is really strange since we expect that the two segments are electronically isolated from each other.
Test:
We tested the ITMX ring heater continuity out to the floor and got 50.2 Ohms for both the upper and lower segments so that is what we expect.  Then to the ring heater on the floor from the RH driver chassis, we saw that it was driving the correct amount when we used a breakout board to measure the voltage across the ring heaters.  The ring heater driver also provides the monitoring tools for the RHs as well such as voltage_mon and current_mon and this could be wired wrong in the Beckhoff chassis.  So we carefully measured the continuity of the connection between the feed through and the EtherCAT modules to make sure that they match our drawings and this is where we found the wiring mistake that had us confused.  Basically, there was a wiring switcharoo between the readouts of the upper and lower segments on ITMX but in a unique way: the positive read back terminal was connected to the upper and the negative read back terminal was connected to the lower.  That would explain why the two segments were coupled when we know that they shouldn't be.  The good news is that ITMY seems to be working just fine and weird up correctly, also, this mixup happened only on the read back side of ITMX RH, which means we don't think that it's actually driving the ring heaters in some unexpected way.  At the first available opportunity, we want to fix this wiring and test the RH again.  Before the next vent, we hope to do some serious testing with the ITM ring heaters, namely turning them on and off in 30 minute intervals for 24 hours to see their response.
H1 SEI (AOS, INS, SUS)
hugh.radkins@LIGO.ORG - posted 16:46, Monday 19 May 2014 (11974)
WHAM4 SEI-ISI Payload change -52.45Kg
With a woefully underestimated increase in the payload, I removed a bunch of wall mass from the ISI.  It unlocked pretty easily and then I commenced to removing more and yet more mass.  But I got there with the table locking/unlocking quite smoothly with well within spec shifts.  A 10Kg D0901075 even had to be removed from the table top.  In the end, the added payload & balance mass is lower by 52.45Kg.  I have red-lined D1001132-v3 with the changes and current mass distribution and added that to the DCC.

The ISI is unlocked with the C3 covers pulled away from the ISI.  HEPI remains locked.
H1 TCS (TCS)
thomas.vo@LIGO.ORG - posted 15:58, Monday 19 May 2014 (11972)
Unexpected laser glitch while CO2X was running
Between the times of 3:24-3:27 PM PT, we saw that the laser on CO2X was turned off when we were trying to initialize CO2Y.  It's not clear exactly what caused this glitch because we had not yet started touching either system during this time frame so we're not sure if this glitch was due to a human interaction or some sort of electronics malfunction.  All we know is that the laser gate was off but that the emergency shutoff had not been pressed on either table.  Also, the laser itself was not shut off but the laser controller had somehow closed the gate.  We're still investigating this issue, we turned the laser on at 10:00 AM this morning so it had been running for about 5.5 hours or so.
H1 General
jeffrey.bartlett@LIGO.ORG - posted 15:54, Monday 19 May 2014 (11971)
Ops Summary
08:50 Corey – Working around the squeezer area on laser enclosure
09:20 Hugh – Working on HAM4 ISI alignment & balance
09:42 Dave – At HAM4 area working on Hartman table
10:00 Jason & Betsy – HAM5 for SRM alignment
10:05 Travis & Gerardo – Working on ACB alignment
10:18 Peter – Working in the H2-PSL enclosure
12:50 Karen – Going to End-Y and Mid-Y
12:57 King Water Systems on site to work on RO system
13:17 Thomas – In and out of LVEA working on TCS
13:51 Gerardo & Travis – Working on ACB alignment 
14:22 Hugh & Scott – HAM4 ISI alignment & balance
14:30 Justin – Transition LVEA to laser hazard 
15:45 Hugh – Turned down purge air at HAM4 and HAM6
H1 SUS
betsy.weaver@LIGO.ORG - posted 14:36, Monday 19 May 2014 - last comment - 12:32, Monday 01 November 2021(11970)
HAM 5 Status

Today, Jeff is on operator duty so I tagged back in on HAM 5.  While Jason was resettting his equipment, I worked on -

- cable routing for SR3, including switching the cables in the bracket since they were mounted backwards.

- positioning all of the lower stage AOSEMs on SR3.

- removing yaw adjustment hardware and torqued remaining dog clamps.

- cable routing on SRM.

- resetting the SRM open light gains/offsets with Arnaud (and creating the safe_snap once set) - Note, this was done because it was last done on a different set of electronics/cables.  Currently, all of the OSEMs are backed out and reading open light - I'll resume setting these tomorrow.

- staging the dog clamps for the upcoming OFI and 3-baffle installs on this table.

Comments related to this report
jeffrey.kissel@LIGO.ORG - 12:32, Monday 01 November 2021 (60477)
J. Kissel

In Nov 2021, looking at the OSEMINF OFFSETs reveals for the past 8 years reveals that SRM has had these same open light current values since this aLOG. 
I'm not sure where the values ended up recorded in terms of the E1200343 excel spreadsheet we used to keep up-to-date, so I report them here, attached to this aLOG for posterity.
The open light current values (OLC values, in terms of ADC counts) are based on the offsets and gains currently installed, where, as always, OLC [ct] / -2 = OFFSET [ct], and 30000 / OLC [ct] = GAIN, so I've derived the OLC value from the existing OFFSET value.

SRM OSEM       Open Light     OFFSET       NORMALIZING 
               Current [ct]   [ct]         GAIN [ct/ct]
   M1 T1       26908          -13454       1.1149
   M1 T2       25472          -12736       1.1778
   M1 T3       28670          -14335       1.0464
   M1 LF       27764          -13882       1.0805
   M1 RT       26272          -13136       1.1419
   M1 SD       25516          -12758       1.1757


Images attached to this comment
H1 SEI (SUS)
arnaud.pele@LIGO.ORG - posted 14:25, Monday 19 May 2014 - last comment - 23:48, Tuesday 20 May 2014(11951)
Oplevs on friday windy night

On friday night, the wind was high(~25mph), and the arm was hard to lock. Although the angular motion of the test masses was not particularly different than on a quiet night. First attachement shows the oplev spectra from friday night, when the wind was ~25mph. second attachement shows spectra from yesterday night with a 5mph wind.

To note :

Non-image files attached to this report
Comments related to this report
lisa.barsotti@LIGO.ORG - 18:02, Monday 19 May 2014 (11976)

We tracked down the problems  we had in the past windy nights to be related with the   ALS tidal tuning , but it is still good to make these plots with the OpLEv signals.

However, I think your plots didn't turn out the way you wanted to. There is only YAW in the second attachment.

Also, it would be easier to make a comparison if you put windy/quiet  curves for each DOF in the same plot. Thanks!

arnaud.pele@LIGO.ORG - 23:48, Tuesday 20 May 2014 (12000)

thanks for noticing! 

Attached are some other plots : 

1. wind at corner and endy stations between may 17th/may 20th. High winds references are marked in orange, low winds is in green

2. Spectra comparison of ground sensors (HEPI STS) at end and corner stations with different winds. Blue and pink curves are during high winds (blue = may 17th, pink = may 18th). Red is during low winds (may 19th). From top to bottom rows : ETMX ETMY and ITMY. From left to right : X Y Z degrees of freedom. 

3. Spectra comparison of oplevs during high winds (may 18th blue curve) and low winds (may 19th red curve) for ETMx ETMy and ITMy top to bottom. Left column is pitch, right column is yaw.

Images attached to this comment
H1 ISC
christopher.wipf@LIGO.ORG - posted 12:34, Monday 19 May 2014 (11967)
ALS tidal tuning

(Stefan, Lisa, Chris)

Looking through the locked stretches from the weekend, we noticed that the ALS slow feedback -- intended to relieve the VCO control signal of low frequency seismic and tidal motion -- was failing in its mission.  What we saw is plotted in the first attachment.  The green trace shows the VCO control signal, which should be forced toward zero when the slow test-mass feedback (red trace) is enabled about halfway through the timeseries. Obviously this wasn't happening. Meanwhile the VCO frequency servo that actuates the tune slider (blue trace) was running away along with the VCO control signal. When the tune slider hits its limit at +/-5 the lock is broken.

We tracked it down to a missing integrator in the ALS-X_ARM filter bank, without which the slow loop didn't have enough oomph at DC to null the fast control signal. I think this filter was removed intentionally (but without realizing its true purpose) during some earlier automation work. We put it back and, taking advantage of the improved test mass plant inversion, we were able to increase the gain upstream (in the ALS-X_REFL_SLOW filter bank) from 1 to 30. This should help prevent the arm from being blown away by the wind.  When we lose lock the integrator is switched off by the Beckhoff, and the drive bleeds away through a 0.01Hz pole.  The improved behavior is shown in the second attachment (where the gain was cranked about 20 minutes in).

Images attached to this report
H1 SYS
daniel.sigg@LIGO.ORG - posted 12:29, Monday 19 May 2014 (11962)
Commissioning calendar for next 2 weeks

Here is the list of commissioning task for the next 7-14 days:

Green team (XY-arm):

Blue team (X/Y-arm):

Red team:

SEI/SUS team:

In-Vacuum preperation:

H1 AOS (INS, SUS)
jason.oberling@LIGO.ORG - posted 12:16, Monday 19 May 2014 (11969)
SRM Surrogate Alignment Tentatively Complete
IAS: J. Oberling
SUS: B. Weaver
 
The fine pitch/yaw alignment of the SRM surrogate was completed this morning (actually, no alignment was required.  Upon setting up equipment to measure the pitch/yaw it turns out we got everything in spec during the rough alignment last Friday).  My equipment is still set up until I get word from SUS that the suspension is healthy; I will also post final alignment numbers at this point.
H1 PSL
jeffrey.bartlett@LIGO.ORG - posted 12:11, Monday 19 May 2014 (11968)
PSL Status Check
As of 12:00

PSL Status: 
SysStat: Green, except VB
Output power: 26.7w  
FRONTEND WATCH: Good
HPO WATCH: Red  

PMC:
Locked: 12min
Reflected power:   1.5w
Power Transmitted: 9.8w 
Total Power:      11.3w 

FSS:
Locked: 12min
Trans PD: 0.94v

ISS:
Diffracted power: 3.833%
Last saturation event: 12m
H1 General
jeffrey.bartlett@LIGO.ORG - posted 11:00, Monday 19 May 2014 (11966)
Morning Meeting Minutes
Jason & Betsy – SRM fine alignment at HAM5
Gerardo – Putting the OFI into storage box and fly over beam tube
Hugh – ISI balancing at HAM4
Travis – ACB balance and alignment
Richard & Filiberto – Chassis work in EE shop & cabling at HAM6
Peter & Olli – In H2-PSL working on ISS assembly
Dave – TCS Hartman table alignment
H1 SYS (SEI, SUS, SYS)
jameson.rollins@LIGO.ORG - posted 10:22, Monday 19 May 2014 - last comment - 17:26, Monday 19 May 2014(11965)
lockloss SUS and SEI watchdog trips should probably be addressed in the watchdog code

The problems we noted over the weekend with the ETM SUS (and sometimes SEI) systems tripping on lock loss (alog 11957) can maybe most accurately be characterized as a watchdog problem.  The trips are caused by large drive transients after lock loss.  It's hard to imagine that there's much we can do to prevent this from happening.  Even if the DARM (CARM, etc.) control signals could be shut off immediately, the residual impulses would still produce large impulse response in the LOCK filters in the suspensions.    We could try to shut off the drive signals in the SUS controllers, or hold the outputs at their current value, but that's a bit more difficult to implement.

In general, though, the watchdogs should probably just not be tripping on transients.  If the watchdogs were a bit smarter and only tripped on sustained saturations or oscillations, this would likely not be an issue.  I vote that we solve the problem in the watchdogs, but increasing the amount of time it takes before they trip.

Comments related to this report
arnaud.pele@LIGO.ORG - 17:26, Monday 19 May 2014 (11975)

I closely looked at one of saturday's trip on ETMX @ 04:44:40 UTC (May 18th 2014). The sequence was :

  • Large kick to UIM actuators (~2e8 cts) (RMS of osems exceeded ~10000cts)
  • ONLY UIM wd trips (the other WD were set at 80000 instead of 8000)
  • ISI ST2 trips on GS13

I will post some data tomorrow

Displaying reports 72501-72520 of 84133.Go to page Start 3622 3623 3624 3625 3626 3627 3628 3629 3630 End