Jamie, Dave, Fabrice,
We have implemented the modifications in the isi2stage master model that were necessary to:
1) Allow good functioning of the guardian
2) Investigate the subtraction scheme we have been talking about to improve teh RZ (Yaw) isolation.
We are testing these changes so we can decide which ones to propagate (ECR, svn commit, install on other units, other sites...)
Details of the changes:
- Added a block in the ST1 block, to filter the T240RZsignal induced by the Z drive. This block is called T240 subtract
- Changed the way the WD "ignore" the T240 when they are not in loop. This is now done in the T240 block instead of being done in the c code. It permits to keep the c code generic for all other types of sensors. The c code is back to 9 inputs. I removed the 10th input in Stage 1 and Stage 2 "Muxes" entering in the Simulink. We must check that everything i s compatible with the HAM-ISI and BSC-ISI models
- Changed the logic to calculate the state of Stage 1 ISO. It is now done with boolean operators. The output returns a "0" if all gains are 0, and a "1" if any of the gains in non-zero. Added an Epics output to monitor this variable.
- Added some logic to reset the T240 counter when the isolation is tuned on.
The model has been compiled, installed and started on ITMY. The T240 counter does reset when the isolation is turned on. However, on the last test I did with the guradian before to hand the unit back to commissioning, it tripped on the T240s. To be investigated tomorrow morning.
Other problems to be fixed:
- the GS13s trip when the boosts of the HEPI horizontal loops are engaged. We must check if it's a matter of adding phase margin or adding some ramping time.
- all the safe.snaps must be updated to record the T240 saturation counter parameters
- for some reasons, the cont2b filters in ITMY Stage 1 X,Y, Z had disappeared. I assumed they were just constant values of "1" and added such filters with foton. To be checked.
- some HEPI ETMX boost filters were not loaded. We loaded constant values of "1" so we could keep working on the guardian. To be fixed.
Hosken, Grabeel, Vo CO2X: - Laser left on running overnight again. - Prepare gig-E camera infrastructure for wiring and software. CO2Y: - Rotation Stage working, turns out that the motor power cable at the feed through was not plugged in. - Starting to connect up temp. sensors on table, looking for the custom clamps that mount the sensors. HAM4 HWS: - Alignment laser is the wrong wavelength for the dichroic mirror which is HR at 650-900nm and HT at 500-550nm. - Lens mounts readied for install in-vac
We twice observed a filter module turn on almost immediately, even though it was supposed to ramp over 15seconds.
It is not reproducable in the sence that it seems to be a random occurance, and usually ramps with the propper time.
8:00-9:42 Getting ready to move clean room in LVEA (Craning) – Apollo 8:30 Water supplier on site – Paradise 8:35 Going into the LVEA to search for parts – Corey 8:40-14:00 Continue assembling/suspending/balancing of the ACB suspension- Betsy/Travis/Margot 8:48-13:02 Heading into the LVEA for SRM alignment – Jason 9:00-11:50 Joining Jason on SRM alignment – Jeff B 9:05-9:44 Retrieving items from LVEA - Gerardo 10:04-12:02 Heading in to the LVEA for TCSx table work – David 10:09-15:43 ICS rack inventory in LVEA – Filiberto 13:14 Restarting ISI model for ITMY – Dave/Fabrice 13:16 Restarting ASC model and the DAQ – Dave/Fabrice 13:32-14:20 Back to HAM5 to connect BOSEMs – Jeff B 14:05 Transitioning the LVEA to Laser HAZARD 14:13 Back to West bay (LVEA) – Betsy/Travis/Margot 14:37 Back to the LVEA for TCSY table work – David/Greg LVEA is Laser HAZARD! NOTE: Today while going over the CDs Check sheet, I noticed that the Right BOSEM on PRM was reading almost 0. I talked to Alexa and concluded that it was because the suspension has been yawed.
Also, the flag of this osem seems to be a bit offcentered when the offsets are off (~ 100 um). We should recenter during next vent.
Heated volume is adjacent to but isolated from unpumped volume seen by PT246A,B gauges -> Ignore readings from PT246A,B until further notice (2 weeks?)
Last week I took some in chamber, in vacuum acceptance measurements for TMSx and TMSy. ISI tables were both isolated during the measurement.
Attached are the 6 Dofs transfer functions measurements as well as the osems spectra for both suspended tables :
1. TMSX TF compared with the model
2. TMSX spectra for each osem, as well as in the euler basis
3. TMSY TF compared with the model
4. TMSY spectra for each osem, as well as in the euler basis
5. TF comparison of both H1 TMSs and L1 TMSs
To note :
The difference seen in the TF of H1 TMSx is explained in previous alogs
TMSx spectra shows excess 60Hz noise in F1 F2 F3 and LF osems (see 2nd attachment)
Damping for the yaw degree of freedom, for both TMSs is increasing the motion at the resonnance (see last page of 2nd and fourth attachment). I will turn the yaw damping off for both TMSs for now.
I have begun and mostly completed the setup for the rough pitch/yaw alignment of the SRM-s. This will be completed tomorrow morning and the rough pitch/yaw alignment will follow.
I ran quick V and R TFs and the sus looks healthy to me compared to old references that Arnaud left me. I need to dig up a good L reference TF and run that in the morning, but then we should be good to go on the pitch/yaw tuning.
And L looks good, too!
Fabrice and Dave:
We successfully made a new h1isiitmy model using the latest isi2stagemaster model changes. We restarted h1isiitmy with the new code
Chris, Sheila, Dave:
I found that I had mistakenly restarted an incorrect h1asc model on Tuesday. After the first DAQ restart that day I noticed that the DAQ picked up a newer INI fle for h1asc and I assumed (which we should never do) that the last "make install" was correct. It appears that later changes were not installed.
I did a clean "make" and "make install" on h1asc and restarted the model.
Dave:
Finally I did a DAQ restart to support the above changes (remembering to wait into the next 10min period to flush out the second trends)
Here is the restart sequence in detail:
2014_05_15 13:16 h1isiitmy
2014_05_15 13:19 h1asc
2014_05_15 13:22 h1broadcast0
2014_05_15 13:22 h1dc0
2014_05_15 13:22 h1fw0
2014_05_15 13:22 h1fw1
2014_05_15 13:22 h1nds0
8:15-8:30 Fred, Richard, Cyrus, Filiberto, Aaron, Bubba, Gerardo, Jeff B, Bubba, Travis, Hugh, Mitchell, Justin, Mike, Thomas, Jeff K, Fabrice, Alexa, Steban, Robert, Jamie, etc. • SRM alignment on HAM5 - (Jeff B/Jason) • TCS tables work continues. – (David, Thomas) • Getting things ready to transport the OFI - (Gerardo) • Craning activity in LVEA / Moving clearoom from west bay -(Apollo) • ICS rack inventory in LVEA – (Richard/Filiberto) • Commissioning work continues (Commissioners) • Testing and assembly operations continue in Staging building –(Jim/Hugh/Scott) • Guardian work in progress -(Jamie) LVEA is Laser SAFE
Richard warned me that the Fiber polarization had probably drifted at EY due to some work done around the table. Indeed it had drifted to up to 33% for the wrong polarization. However, Stefan had increased the threshold to 36. I returned the threshold down to 30 and adjusted the controller. I also had to adjust the EX polarization when I turned the controller on, which forced both polarizations to drift. All is good now.
Craning activity in the LVEA at the moment. A cleanroom is being moved - Apollo
model restarts logged for Wed 14/May/2014
2014_05_14 12:37 h1fw1
unexpected restart of h1fw1
Kiwamu, Stefan, Both ALS_DIFF and ALS_COMM were straight forward today, and we got them locked literally in minutes. I.e. the ESD is still working fine. We misaligned the arms, and verified that 3f locking works just fine without the arms. We locked the arms and parked them 1kHz off resonance. I this configuration the the RF27_I signal worked fine, but the REFL27_Q signal had significant contamination from the COMM noise at 70Hzish (periscope peak). Thus we designed a broad notch filter in the mich loop, which kept the BS from saturating. However it seems that MICH is still too strongly contaminated by the low frequency COMM noise. As a result the MICH loop seems to drift out of its linear range. Ideas: - divide REFL27_Q by POP_18 to expand the linear range - rephrase REFL27 to reduce the coupling Either way, an earthquake told us to get some sleep.
David H, Greg G, Thomas V - Corner Hartmann table now has the Y-arm in-air optics mounted and positioned, ready for alignment using the visible laser. Components for the HWS were tracked down and staged. - TCSX CO2 laser continued to run all day. Once going to laser hazard we realigned the CO2 beam that is transmitted through the output beam splitter. This transmitted beam passes through another 50/50 beam splitter, with the (second) transmitted beam aligned to the output power meter, while the reflected beam was expanded and aligned to the FLIR camera screen position. This required the repositioning of some cables and mounts located near the CO2 laser and RF driver. TSCX laser will continue to run overnight. Rotation stage set to 44 degrees (with interlock cable removed to prevent changes to this angle). Table doors are locked. TSCY chiller and power supplies continue to run, TCSY laser is turned off.
Richard showed me that there is a liner coupling from any of the electrodes to the OPLEV even when there's no bias anywhere, and the bias-less coupling is on the same order as the coupling with bias.
I started flipping the bias of the common ("DC") electrode while keeping all four quadrants at zero count output, and indeed there's a linear coupling, and the effect is not subtle.
In the attached, I changed the DC bias from 125000 to 0 to -125000, then to 0 and finally back to +125000. The ETM points up by 0.3urad in the first step, then further up 0.5urad in the second step (instead of going back to the original position). It's 0.8 urad peak to peak!
OTOH, when I set the four quadrants such that top two outputs -50900 counts and the bottom +50900 to tilt the optic legitimately while the DC bias is kept at 125000 counts, I can only move it by -0.5 urad peak to peak (second attachment).
This could still be electronics offset, so I looked at the ESD readback. The readback is not calibrated, but four quadrants always read from -75 to -200 counts when I'm outputing zero, the 300volt-ish thing reads 30000-ish counts, so the voltage offset for the quadrants should be 2V-ish at most. That's not large enough, I think.
I disconnected the ESD drive cables between the current limiting resistor and the flange. Put large drive signals on the cables and did not see a response in the oplev. So it is not a direct coupling in the rack or cables up to the chamber.
At LASTI we saw static charges on the test mass high enough to mimic a bias voltage of 125 V (very large!). John Miller put together a procedure and MATLAB script for measuring what this effective bias was. So the problems you are seeing with a non-symmetric response are within the limits of what has been observed before. See the LASTI ilog http://emvogil-3.mit.edu/ilog/pub/ilog.cgi?group=lasti&task=view&date_to_view=12/18/2009&anchor_to_scroll_to=2009:12:18:16:36:37-brett u: reader p: readonly This script happens to be on the svn at /ligo/svncommon/SusSVN/sus/trunk/QUAD/Common/MatlabTools/ChargeScript It will need some modification to work at the sites, since it was written to work in the old LASTI file structure. Basically though, it automatically runs DTT from MATLAB, and measures the response at 11 Hz with a range of bias voltages. Note, Rai has put together a gizmo to discharge the test masses with ionized nitrogen. Not sure of its status. Venting to some torr might also help, not sure.
The discharging rig Brett is referring to is described in LIGO T1100332. It currently resides at MIT under clean conditions. It and the associated electronics can be shipped to LHO. It needs a 2 3/4 inch conflat gatevalve attached to one of the ten inch blank flanges on the BSC chamber at the charged mirror height. The gas injected into the deionizer needs to be clean nitrogen such as the boil off from liquid nitrogen passed through another liquid nitrogen trap and warmed to room temperature before injection into the BSC. RW
I think that the ISI trip happened before the suspension trip, this was while we were locking diff. I also thought that the T240s were green before I untripped the watchdog, but maybe they weren't because the ISI tripped again as it was isolating.
I stongly suspect that the second trip is due to the bug Fabrice and I noticed in 11888
This afternoon, after Jeff balanced the coils, I took measurements on the main chain of ETMY for filter design.
Results attached are showing Length/Pitch/Yaw drive to Pitch/Yaw Response for the top mass, UIM and PUM. Y axis is in urad/cts
Templates live in the usual sus path H1/ETMY/SAGL1/Data/2014-04-16_H1SUSETMY_P2PY_WhiteNoise.xml
Corrected version (without mistakes !)