Reports until 16:56, Monday 12 May 2014
H1 ISC
sheila.dwyer@LIGO.ORG - posted 16:56, Monday 12 May 2014 (11831)
cameras, Y end laser

This morning the end Y laser was off and had no power, Richard looked around and noticed that there was an extension chord which had come loose.  He changed the way that this is plugged in so this should not happen again.

Alexa and I placed the GigE camera on ISCT1 for the X arm.  

I also went out to End Y a few times to work on the IR path there.  The LSC PD is now aligned for the IR trans, the gain setting is 60dB.  The power cable is flaky for the analog camera.  Aaron and Fil helped get the signal to the control room. Although the spot is faint you can see it in the upper right hand corner of channel A on the lower monitor. 

LHO General
gerardo.moreno@LIGO.ORG - posted 16:28, Monday 12 May 2014 (11830)
Operator Shift Summary

8:54 am, Jeff and Andres to the CS VEA, work around HAM4/5 area.
9:05 am, Jason to the CS VEA, East bay area for alignment work. <-- Done by 12:33 pm.
9:20 am, Jeff requested aide from Apollo, work on and around HAM6, 30 min. curtain work while using a small scissors lift.
9:20 am, Travis to the CS VEA, West bay area for ACB assembly work.
9:30 am, Betsy  to the CS VEA, East bay area work.
9:42 am, Richard to End Y VEA, ESD work.
10:18 am, David H. to CS VEA, near HAM4, Hartmann sensor table work.
11:00 am, Restarted video4, loaded camera views only, no striptool, elimination process for "freezing" issue.
12:00 pm, ACB crew out of CS VEA.
12:45 pm, Cris to X-End station VEA, cleaning.
12:45 pm, Karen to Y-End station VEA, cleaning.
1:11 pm, Travis to CS VEA, West bay area for ACB work.
1:13 pm, Mitchell to CS VEA, West bay area for ACB work. <-- Done 2:20 pm.
1:16 pm, Betsy to CS VEA, West bay area for ACB work.
1:45 pm, Justin transitioned the LVEA to laser hazard.
2:30 pm, Thomas and David to CS VEA, East bay area for TCS work, powering laser inside table.
2:45 pm, Mark L. to CS VEA, TCS install work.
3:45 pm, Jeff and Andres to CS VEA cleaning area. <-- done 4:05 pm

 

H1 ISC
kiwamu.izumi@LIGO.ORG - posted 14:55, Monday 12 May 2014 (11829)
PD offset nulling script modified

I noticed that the PD offset nulling script for PRMI did not run for some reason. I looked into the script and found that this was due to too-many PD channels requested to tdsavg at once. So I modified the script so that it divides the PDs into a number of group. This seems running OK at a expense of the processing time. The modified script is named as lsc/h1/scripts/pdOffsetNull_ver2.py. I also checked this script into the svn.

LHO General (CDS, PEM)
patrick.thomas@LIGO.ORG - posted 14:27, Monday 12 May 2014 (11828)
Restarted the IOC for the weather station at end Y


			
			
H1 AOS (INS, SUS)
jason.oberling@LIGO.ORG - posted 12:46, Monday 12 May 2014 (11827)
SR3 Final X, Y, Z Position
IAS: J. Oberling
SUS: J. Bartlett, A. Ramirez
 
SR3 was pushed into place this morning.  The final position errors are below:

I have begun setup for the pitch/yaw alignment; will finish fine set tomorrow morning and we will commence with SR3 pitch/yaw alignment.

H1 SEI
arnaud.pele@LIGO.ORG - posted 12:40, Monday 12 May 2014 (11826)
BS ISI tripped

BS ISI tripped at 12:25pm. Certainly due to a second earthquake (5.8 southern east pacific rise)

Images attached to this report
H1 DAQ
betsy.weaver@LIGO.ORG - posted 12:30, Monday 12 May 2014 (11823)
EY Wind channel died

FYI - The EY wind channel died ~2 hours ago.  Richard reports that "someone was working out there and it's probably related."

H1 SUS
betsy.weaver@LIGO.ORG - posted 12:28, Monday 12 May 2014 (11822)
ETMx OL SUM is way low

While poking around looking at screens in the control room this morning, I noticed the ETMx OL sum is was low.  Some trends reveal that there was a drastic drop of the laser power on the QPD on Sat morning.  A trend of ETMx signals, as well as some ISI and HEPI signals (not shown), indicate those systems are ~healthy.  So, it does not seem that the physical pointing of the ETMx via SUS or SEI has changed the pointing on the OL.  Note, this happened a day after the Fri EQ which caused all the ISIs to trip.  Likely we should investigate the OL itself to see what's going on with the laser beam/QPD.

Images attached to this report
H1 SUS
betsy.weaver@LIGO.ORG - posted 12:25, Monday 12 May 2014 - last comment - 12:36, Monday 12 May 2014(11821)
Friday night Earthquake

Arnaud reports that at ~midnight last Friday night, all of the ISI tripped due to an earthquake.  There was a magnitude 6 EQ in Mexico May 10 07:36 UTC which correlates to the ISI's tripping at 07:50 UTC.

Comments related to this report
arnaud.pele@LIGO.ORG - 12:36, Monday 12 May 2014 (11824)

cf alog for ISI plots

H1 SEI
sheila.dwyer@LIGO.ORG - posted 12:03, Monday 12 May 2014 (11820)
ETMX ISI tripped

Gerardo says there is an earth quake on the oregon coast, so far end X is the only one tripped.

Images attached to this report
LHO FMCS
john.worden@LIGO.ORG - posted 11:52, Monday 12 May 2014 (11819)
YEND Station temperature

Here is the last 30 days of YEND temperatures. Shown is the LVEA average and two of the four zones from which the average is derived.

The large positive spike is experimentation with chilled water flow - (Robert and John on 4/20).

The smaller negative going spikes are not explained but may be related to human actions as I have stopped and started chillers several times in this period for diagnostic purposes.

Images attached to this report
H1 SEI
arnaud.pele@LIGO.ORG - posted 11:51, Monday 12 May 2014 (11818)
Some ISI trips from the week end

It's not clear what caused the trips from this morning. The ones from Friday night seem to be related to earthquakes.

Images attached to this report
H1 AOS
keita.kawabe@LIGO.ORG - posted 11:19, Monday 12 May 2014 (11817)
EY OL laser oscillation at 0.32 Hz.

It's not a problem for now, even if we use oplev damping, because the oscillation leaking to the oplev error signal (attached, a tiny bump at 0.32Hz for green curve) is small enough.

Anyway, it seems like this has been going on for the past  four weeks (second attachment), and even if it doesn't get worse, oplev people should look at it after the integration test.

Oplev SUM peak-peak was a factor of 10 worse before it settled down to the current state (beginning of the second attachment), but I cannot see the raw data so we cannot say what was going on then.

Images attached to this report
H1 CDS (DAQ)
david.barker@LIGO.ORG - posted 08:44, Monday 12 May 2014 (11816)
CDS model and DAQ restart report, Sunday 11th May 2014

no restarts reported.

LHO General
corey.gray@LIGO.ORG - posted 08:42, Monday 12 May 2014 (11815)
Installation Meeting Minutes
H1 CDS (DAQ)
david.barker@LIGO.ORG - posted 12:04, Sunday 11 May 2014 (11814)
CDS model and DAQ restart report, Saturday 10th May 2014

model restarts logged for Sat 10/May/2014
2014_05_10 05:02 h1fw1
2014_05_10 18:42 h1fw0

both unexpected restarts, not simultaneous so no data lost.

H1 CDS (DAQ)
david.barker@LIGO.ORG - posted 07:57, Saturday 10 May 2014 (11812)
CDS model and DAQ restart report, Friday 9th May 2014

No restarts reported.

H1 SUS
arnaud.pele@LIGO.ORG - posted 20:34, Thursday 08 May 2014 - last comment - 19:30, Thursday 15 May 2014(11786)
SR2 lower stages TF

Yesterday night, I tried to run SR2 M2-M2 and M3-M3 (lower stages) in chamber transfer functions after the osems were centered on wednesday. Although both M2 and M3 watchdogs tripped during the measurement, so I am running it again tonight. (This time, I decreased the drive and increased the watchdog threshold).

Comments related to this report
arnaud.pele@LIGO.ORG - 10:17, Friday 09 May 2014 (11799)

Decreasing the drive didn't help either since I ended up with measurements without coherence. This morning I tried to drive M2 stage with high amplitude sinewaves at the resonant frequencies of the suspension for each DOF (L P and Y) to see if the osems would saturate. They don't. So a drive of 500 000 (cts) for L and 20 000 (cts) for P and Y (which is the limit before saturating the DAC) should be optimum at all frequencies. Started a new measurement which will run today.

arnaud.pele@LIGO.ORG - 22:32, Friday 09 May 2014 (11811)

This time, phase 3a M2-M2 and M3-M3 measurements of SR2, in air, with the HAM-ISI locked were succesful. The actuation is functioning, and the transfer functions for the three degrees of freedom are similar to the model.

There is one interesting feature to note for M2 stage. From 10Hz, the measured tf rolls up, as if some extra zeros were added to the tf. I checked the osem output filters, and they seem to compensate correctly for the coil driver (looking at the state diagram in state 1).

Non-image files attached to this comment
arnaud.pele@LIGO.ORG - 19:30, Thursday 15 May 2014 (11928)

Attached are some SR2 phase 3a spectra for future reference

Non-image files attached to this comment
H1 AOS
matthew.heintze@LIGO.ORG - posted 19:50, Thursday 08 May 2014 - last comment - 09:40, Sunday 11 May 2014(11785)
TCSx--success

(David H, Thomas V, Greg G, Alasitair H, Matt H)

Well if yesterday was "The Empire strikes back", today was "Return of the Jedi" and the good guys had a win.

 

You may remember from this mornings alog that we had been having a few troubles with the alignment of TCSx.

 

After a brainstorming meeting with Aidan the decision was made to ignore the path defined by the flipper mirrors having problems with (what is supposed to be the central heating path) and align what is the annular heating path (which only uses mirrors) to the output beam splitter and through the irises defining the beam path up the periscope, into the chamber and onto the CP. We will then use the central heating mask instead of the annular heating mask (in the location the annular heating mask would be ), and thus temporarily turn the annular heating beam path into the central heating beam path.

The first step we did was to use a HeNe beam to adjust the output beam splitter and the beamsplitter just before the on table power meter so that the front and back reflections were in the same plane (they werent installed that way). We then went all the way back to the first large gold mirror after the polarisers (which are after the beckhoff controlled HWP) and mirror by mirror in the annular (now temporary central heating) beam path made sure that they were set so that the beam was in a plane with the table at a height of 4 inches.

Once the beam got to the output beamsplittler, the beamsplitter and the last gold mirror before the periscope was used to align the beam to the irises that we had defined to put the beam correctly into the chamber. I roughly made sure that the beam transmitted through the output beam splitter was going to the on table power meter, and the beam path that would go to the FLIR camera was beam blocked as I no longer no that the beam path is correct (I removed the lens there so that needs to be reinstalled).

A HeNe beam was setup to trace through the irises (heading in direction of going towards the periscope). Once the optic beam path had been re-established I swapped out the 1" irises we had (which had clipping on the beam occuring) for 2" irises. We then inserted a 2 inch gold mirror into the path between the 2 irises and sent the HeNe beam down towards HAM5 and the target that we had set up at a distance that mimicks where the CP would be. An "X" was marked on the card and the HeNe aligned to this "X' and the FLIR camera setup so that this spot was centered on the camera.

HeNe beam removed and the CO2 beam projected onto the target. Good to see that the CO2 beam appears to hit exaclty where the HeNe indicated it should (lets out sigh of relief)....so this should mean that the CO2 beam should go into the chamber and onto the CP correctly. Whilst doing the projection we also placed in the central heating mask (it has been rotated 90 degrees so that the rejected beam is directed towards the edge of the table not the center of the table as indicated in the drawing because the beam dump would not fit) and used the projection to help center the mask. Worked well...and success was declared. I dont have the pics of the projection, but pics were taken.

All beams have beam blocked so that if wanted to run the laser around the clock we can (we wont be until given the go ahead by the local LSO). A bugzilla list (Bug 868...https://services.ligo-wa.caltech.edu/integrationissues/show_bug.cgi?id=868) has been made of the tasks that can think of that are still outstanding/need to be done for this table.

One concern: A couple times today we had further issues with the HWP. We would dial up an angle for it to go to, the MEDM screens would indicae that the HWP was at the angle we had requested yet it physically was at a different angle. I have asked Thomas to look into tomorrow as this is a concern.

 

Pic:

TCScurrentalignmentstanding shows a quick summary of whats aligned and what still needs to be done

Images attached to this report
Comments related to this report
justin.bergman@LIGO.ORG - 07:52, Friday 09 May 2014 (11795)

Awesome work. Great job doing a difficult operation in a safe manner--thanks. I think we can start running TCSx unattended starting Monday.

greg.grabeel@LIGO.ORG - 10:31, Friday 09 May 2014 (11800)TCS
Some pictures from the FLIR of the projection in action. These pictures show the projection and the projection through the heating mask onto our paper target. The heating seen was about 2° C above ambient and the ruler in the picture is 12"
Images attached to this comment
matthew.heintze@LIGO.ORG - 09:40, Sunday 11 May 2014 (11813)

Pics of projection setup and also the table as it stood when I left thursday night

Images attached to this comment
Displaying reports 72641-72660 of 84124.Go to page Start 3629 3630 3631 3632 3633 3634 3635 3636 3637 End