Displaying reports 72661-72680 of 84095.Go to page Start 3630 3631 3632 3633 3634 3635 3636 3637 3638 End
Reports until 16:09, Thursday 08 May 2014
H1 SEI (INS)
hugh.radkins@LIGO.ORG - posted 16:09, Thursday 08 May 2014 (11780)
WHAM5 ISI Table Payloaded w/ make up weight per D1001139-v2
With much help from Apollo Mark we positioned and torqued down 170kg (10)xD0901075-03 Bulk Trim Mass per the layout on D1001139-v2.  I did NOT viton damp any of these--SEI will take care of that after things settle.
LHO General
patrick.thomas@LIGO.ORG - posted 16:03, Thursday 08 May 2014 (11765)
Ops summary
08:33 Jeff and Andres heading out to work on SR3
08:58 Apollo done craning box for Joe D. at mid Y
09:19 Betsy going into HAM4, baffle and payload work
09:32 Let car from fire department in through gate
09:45 Praxair driver called to report that he was 10 - 15 minutes away
09:47 Travis and Margot heading out to work on the ACB in the LVEA test stand
Rick investigating PSL ISS locking problems. He adjusted the ISS reference signal (H1:PSL-ISS_REFSIGNAL) from -1.79 to -1.69 and the ISS locked with ~ 8% diffracted power.
David H. going to get parts from the LVEA X slab, then Hartman sensor work for ~30 minutes.
10:27 David H. done, out of LVEA
10:56 Jeff and Andres done at HAM5
11:03 Sheila working on the end Y ISC table
12:24 Justin transitioning the LVEA to laser hazard for TCS work
12:35 School tour in control room
13:03 Thomas V. restarted the H1ECATC1 system manager to add links for the TCS Y rotation stage. He then went to connect the stage to the H1 PSL ENV Beckhoff chassis (requiring a power cycle of this chassis).
13:10 John W. to end Y chiller yard to look at water system
14:24 Hugh heading out to add dummy mass payload to ISI table in HAM5
15:45 I updated the conlog channel list using the file that Dave generated yesterday. The number of unmonitored channels is taking a long time to come down.
H1 CDS
david.barker@LIGO.ORG - posted 16:03, Thursday 08 May 2014 (11779)
RFM IPC errors, ISC EX and EY senders, LSC receiver

We have notice a steady patter of IPC receive error on the LSC model for the H1:LSC-[X,Y]_TR_A_RFM signals coming from ISC EX and EY for many week. Lately with an increase in the number of ISC IPC channels this error rate has been increasing (it used to be one an hour or so).

It should be noted that these are almost always single errors, i.e. one data error in 16384 in a one second period. Very occasionally the error rate is 2.

I have just measured the number of errors over a 10 minute period for the IPC channels. The Y arm signal gave 30 errors (average of one every 20 seconds), the X arm gave 5 errors (average one every two minutes).

I have also noted that:

there are other RFM IPC channels coming from ISC end stations to LSC which don't show any errors (H1:ALS-[X,Y]_ARM_RFM).

there are the same number of IPC channels from X and Y arm, so why is the Y error rate 6 times higher?

Even at 30 errors in 10 minutes this is an error rate of 0.0003%

LHO FMCS
john.worden@LIGO.ORG - posted 14:44, Thursday 08 May 2014 (11777)
FMCS ENDY

Robert had tried to operate the YEND chiller 1 on its variable speed drive but had difficulties with it.

I spent some time out in the chiller yard today and the chiller now appears to be working at 35 hz (rather than the line frequency) I am not sure why it is working now but it may have just been a startup issue after having sat for a long time with no water flow through the heat exchanger. I did have trouble starting the unit but ran the frequency up to 50hz where the chiller started and continued to run. After several hours I have dialed the frequency down to 35 hz. Temperatures in the heat exchanger(evaporator) appear to be normal. The error message when tripped was " Chilled Water Flow(Ent Wtr Temp)"

 

If there are problems with cooling in YEND please switch to the other chiller. (Or call me)

john

H1 SEI
patrick.thomas@LIGO.ORG - posted 14:32, Thursday 08 May 2014 - last comment - 14:49, Thursday 08 May 2014(11775)
BS ISI ST2 GS13 WD trip plot
Plot attached.
Images attached to this report
Comments related to this report
patrick.thomas@LIGO.ORG - 14:38, Thursday 08 May 2014 (11776)
Tripped again.
Images attached to this comment
patrick.thomas@LIGO.ORG - 14:49, Thursday 08 May 2014 (11778)
Sebastian says that this is a known issue from interactions with the suspension and to leave it tripped for now. It is still isolated on ST1.
H1 ISC
sheila.dwyer@LIGO.ORG - posted 14:22, Thursday 08 May 2014 (11774)
ISCEY IR path work

Durring the earth quake this morning I went out to End Y to work on the IR path, using the small amount of green light reflected into that path.  As Keita said, the beam divereter is open when the medm screen indicates that it is closed.  I moved the top periscope mirror down several inches, and moved the whole periscope about  inch closer to the corner station.  I had to use the third actuator to get a larger angle on bothof he periscope mirrors, this was the same situation as with the X end table and is because the beam comes out of the chamber at an angle.  The path is roughly aligned to the PD and camera, but will need to be tweaked up when we can align the Y arm and use IR.  I also replaced the camera cable with the one that Aaron and Keita left, although it is not labeled yet, checked for a signal, and connected it to input 2 on the video box (I also moved the cable for the ETM to input 1 following Fil's instructions).  

H1 INS (SEI, SUS, TCS)
hugh.radkins@LIGO.ORG - posted 13:21, Thursday 08 May 2014 (11772)
SRS Cables run HAM5 per D1101917
These are run from the vacuum feedthru up onto the Optical Table.  SUS will connect to SUS etc.  SUS has serial numbers and will ICS those and mate accordingly.
H1 SEI
sebastien.biscans@LIGO.ORG - posted 10:19, Thursday 08 May 2014 - last comment - 10:21, Thursday 08 May 2014(11767)
Earthquake

All the BSC-ISI tripped, starting at 1083604427, except ETMX which was on High Blends (no T240s in the loops)

Comments related to this report
sebastien.biscans@LIGO.ORG - 10:21, Thursday 08 May 2014 (11768)

6.8 -- 13km WSW of Tecpan de Galeana, Mexico

H1 SEI
patrick.thomas@LIGO.ORG - posted 09:00, Thursday 08 May 2014 (11766)
end X ISI ST2 trip plots
I found stage 2 of the ISI at end X tripped this morning. Both GS13 and ACT were indicated as first triggers. Plots are attached.
Images attached to this report
LHO General
patrick.thomas@LIGO.ORG - posted 08:45, Thursday 08 May 2014 (11764)
Installation meeting notes
SR2 is aligned.

SR3 was installed last night. It will be clamped down and wired today.

Betsy is working on baffle installation in HAM4. There are issues with the cookie cutters.

No TCS projection likely today. This is Matt's last day. He would like laser hazard ASAP.

WFS work is on hold.

Staging the ITM in the beer garden is on hold.

A faulty ESD cable at end X was found and fixed yesterday. Work continues today.

Work on 3rd IFO assembly continues in the staging building.

Joe D. wants to get access to a box at mid Y. This will require craning another box out of the way.
H1 AOS
matthew.heintze@LIGO.ORG - posted 07:49, Thursday 08 May 2014 (11762)
The saga of TCSx

(David H, Matt H)

So a silly assumption that I made has caused me to make what I consider a rookie mistake and thus we are having a few problems with TCSx alignment.

 

The story thus far. We are trying to set the beam height to 4 inches in height to be flat across the table. This was accomplished up to the polarisers after the Beckhoff controlled waveplate (see layout) and for the ISS photodiode alignment, the quadrant detectors. Now the silly assumption I made (and I kick myself as it was hammered home to me all throughout my phd to never assume anything, and thats been my mantra at LIGO, until this one time...and its bitten me..*sigh*) is that because the two polarisers and the flipper mirror (which is next in line for the central heating beam path) were all in fixed mounts that if the beam coming onto them was parallel with the table at 4 inches, then the beam after it had reflected off all these optics would still be parallel with the table at 4 inches.

With this assumed knoweldge and because the optics had all been laid out in roughly the right position in advance making the table cluttered (no excuse I know), to check if each mirror, beamsplitter, etc I used in the path after these optics  was projecting the beam correctly I placed a target as far away as I could and projected the beam onto a target and altered the vertical adjustment of each mount until the beam came to 4 inches on the target. Now this technique only works if the beam incident on the optic you are testing is horizontal with the table, if its not you are just setting the beam height to be 4 inches at that one spot and the beam path could actually be going up and down. What I should of done is what I always normally do with optics and check the beam height up close and far away and see that it stays at the same height...lesson learned....*sigh*.

 

I had aligned the central heating path with a little trouble but got a solution so that the beam path would go be able to go through the irises we had marked as our optical axis to get the beam up the periscope and into the chamber and onto the cp correctly (this we had done the other day with the HeNe beam....Im sorry on the layout I forgot to mark the iris location but they are between the last gold mirror (at the top of the page) and the periscope). The trouble came when we tried to get the annular heating path to also go through these irises, we couldnt find a solution to do so. David came up with the brilliant solution to shine a HeNe through the irises the other way and see what the beam path should roughly be for the annular heating. What we found is that the HeNe beam shot over the top of the mirrors used to steer the annular heating beam onto the beamsplitter meaning no solution was in fact possible with what I had laid out. 

 

So whats the problem. The problem is in my assumption. With everything in its current layout, we used a combination of CO2 beam and HeNe beam to look at what the reflections of the polarisers and optics in the flipper mirrors are doing. What we found is that each of the two polarisers after the HWP both kick the beam up, as does the first flipper mirror after the polarisers, and the 2nd flipper mirror kicks the beam down (we are talking numbers like 1/4 inch over say 15-20 inches). I checked the two flipper mirrors set aside for the TCSy table and they both kick the beam up as well.

 

This did not bite us with the central heating beam (for the moment, it would of when went to put the mask in and wondered why the beam was not at 4 inches) as the otics are all nice and close to each other, so even if the beam is going up and down a bit, they still hit roughly the center of the optics and can find a solution to get the beam through the irises we set to align the beam heading  towards the periscope. It turns out that the optical beam path off the second flipper mirror towards the beamsplitter that recombines the central heating and the annular beam path, is on a downwards slope (because of the flippers/polarisers throwing us out of plane). It bites us for the annular path because its such a long lever arm that to match the optical path set by the central heating optics we would need such a steep angle of the beam that the mirrors we used to steer the annular path onto the beamsplitter cant provide this.

 

Sooooo whats the solution. Well first...never make assumptions again. But in all seriousness there are solutions and I throw out options without having really thought about it or having discussed it with the TCS folk like Aidan. Options include, using flipper mirrors (like those I believe that were used in eLIGO) that have vertical adjustment so that we can correct vertical alignment, putting in an extra mirror in a bow tie type arrangement to try to correct out the vertical kick up or down, change the layout (but keep the length the same) of the annular path so that at least one of the steering mirrors is closer to the second flipper and so we can try to match the downward trajectory of the beam path set by the second flipper for the central heating route. We could try to remount the polarisers better. Again this is all just being thrown out there for now.

 

Hopefully you arent all thoroughly confused by now, and I really am sorry we didnt catch this earlier. Kicking myself all night for such a rookie error and feeling wasted peoples time. If nothing else its given us fair warning to look out for this on TCSy and when we do the two livingston tables, so it actually could be a time saver by finding this problem now on the first table and coming up with a solution.

Non-image files attached to this report
H1 CDS (DAQ)
david.barker@LIGO.ORG - posted 07:33, Thursday 08 May 2014 (11763)
CDS model and DAQ restart report, Wednesday 7th May 2014

model restarts logged for Wed 07/May/2014
2014_05_07 01:02 h1fw0
2014_05_07 05:53 h1fw0

2014_05_07 08:45 h1fw0
2014_05_07 10:11 h1nds0
2014_05_07 14:46 h1fw0

Minute trend offloading caused the unexpected h1fw0 restarts, completion of this work required the later restarts.

H1 SUS
kiwamu.izumi@LIGO.ORG - posted 03:43, Thursday 08 May 2014 - last comment - 11:12, Thursday 08 May 2014(11761)
TMSX and TMSY

I launched TF measurements on both TMSX and TMSY for Anaud at around 3:43 AM local.

Comments related to this report
arnaud.pele@LIGO.ORG - 11:12, Thursday 08 May 2014 (11770)

Thanks Kiwamu !

H1 ISC (ISC)
stefan.ballmer@LIGO.ORG - posted 02:17, Thursday 08 May 2014 - last comment - 03:32, Thursday 08 May 2014(11759)
A slider, a switch, and a button: catch me if you can
Kiwamu, Stefan

The story of the evening is short:
 - H1:ALS-C_DIFF_PLL_GAIN was accidental increased to 26dB. Up there the PLL oscillates - the gain has to be 6dB.
 - The power on the ETMX UIM coil driver was off - it should be on.
 - The ESD was in a dead state - we had to recycle the power to get it back.
 - Fixing these things took a very short time - its finding them that took all evening...

 - Before starting to chase these 3 needles in the haystack we also updated the L3 inverse plant filters to match the 0.5Hz resonance of the upper stages exactly. This should guarantee a stable behaviour of the blend filters at 0.5ish Hz.

 - Finally we measured the gain ratio between the TOP/UIM combined actuator and the TST actuator at two frequencies:
           TST/(TOP&UIM) ratio
    2.5Hz      2.9
    4.0Hz      1.9 
i.e. the TST drive was  2 to 3 times stronger than the TOP/UIM actuator. We set the TST gain to 0.5.

 - When we finally tried this at the end of the evening, and got the UGF to 1.2Hz. This was done with two additional p5z50 roll-offs.
 - The resulting coil output spectra are attached.

 - Next Kiwamu put in a boost at low frequency to suppress some noise - we got an RMS of ~100Hz in infrared.
 - In this configuration we are limited by the ESD around 3Hz and the UIM drive around 10Hz in about equal amounts.
    Ideas:
      - Get a factor of two in ESD range by using additional drive offset and linearisation
      - Get a factor of two in total range by using ETMY too.
      - Fine-tune the the UIM/TST blend filters with the measured coil noise in mind.
      - Resurrect PUM drive around 10Hz?
      - What is the diff noise from 3hz to 10Hz?
Images attached to this report
Comments related to this report
kiwamu.izumi@LIGO.ORG - 03:32, Thursday 08 May 2014 (11760)

Here are some screen shots and plots:

The blue trace is the open-loop error signal withou supression and all the rest is closed-loop spectrum with some different gain/cross-over settings.

The below is a screen shot of StripTool showing nobody is saturating.

Images attached to this comment
H1 ISC
daniel.sigg@LIGO.ORG - posted 13:33, Wednesday 07 May 2014 - last comment - 16:54, Thursday 08 May 2014(11748)
ISCT1 work

(Alexa, Daniel)

Continuing yesterdays work we locked on PRX and installed the beampspitter in the POP path in front of POPAIR_A. The beam was very weak and we had some fun aligning it. We needed an additional lens (ROC 500mm) to keep the beam small. After the beam combiner we measured 170nW of power. Another short focal length lens was installed after the combiner to focus the beam down. We are still missing a photodetector.

Comments related to this report
alexan.staley@LIGO.ORG - 18:11, Wednesday 07 May 2014 (11757)

We have set up the ISCT1 ALS-Y-GREEN digital video camera (number 05 on the camera overview screen). We have left the CCD on the table in case we need it for any reason. We are still using the CCD camera for the x-arm, but the digital video camera is ready and in place when we want to swap that out. 

I also brought BBPD (S1200247) from MY to ISCT1. The PD is mounted. Power and cables are still needed, but Kiwamu indicated we can borrow the 3f PD power from the legacy PD interface.

alexan.staley@LIGO.ORG - 16:54, Thursday 08 May 2014 (11781)

I have removed the CCD camera used for the y-arm beam and returned it to the shelves by the field racks.

I placed an ND06A (25±4% transmission for 1064nm) before the 50/50BS to reduce the power coming in from the PSL reference path. We also have a ND10A (10±4% transmission for 1064nm) readily avaliable (and it's an easy swap) if need be. The BBPD max incident power is 50mW for 1064nm. I have not measured the incident power yet.

Thanks to Stefan and Kiwamu, we got PRMI locked. This is much easier to work with :). I was able to do a rough aligmnet of the two beams by adjusting the BS. It remains to install the BBPD, but we have everything ready, so this should not take long and we should be able to finally do our measurement tomorrow.

H1 SEI
sebastien.biscans@LIGO.ORG - posted 09:54, Wednesday 30 April 2014 - last comment - 11:09, Thursday 08 May 2014(11643)
HEPI ETMY issue fixed

Jim reported some issues on ETMY HEPI yesterday https://alog.ligo-wa.caltech.edu/aLOG/index.php?callRep=11618

Turns out that the position loops used were adding extra amplification at 10Hz (a 10Hz already amplified by the pier on this chamber). This was causing the HEPI to go unstable, dragging the ISI with it.

I switched to the controllers installed in FM2&FM3 (Cont_2), which are more generic, less aggressive loops. It works just fine.

 

ETMY chamber is used by the commissioners right now, but as soon as I have a chance I'll modified the design of the Cont_1 loops.

Comments related to this report
sebastien.biscans@LIGO.ORG - 11:09, Thursday 08 May 2014 (11769)

More info about this HEPI instability:

- This instability shows up mostly in Y (see ETMY_Sensors.png)

- This unstability is seen by the postion sensors and the actuators on HEPI (see ETMY_drive.png). The thing is that the HEPI-L4Cs, then the ISI-GS13s saturate (and make the platform trips) way before the IPS and ACT do.

- Find attached a screenshot of the actual filter installed. Removing the "bumps" at 10Hz and 45Hz fixed the problem.

Images attached to this comment
Displaying reports 72661-72680 of 84095.Go to page Start 3630 3631 3632 3633 3634 3635 3636 3637 3638 End