Reports until 12:01, Tuesday 29 April 2014
H1 TCS (TCS)
aidan.brooks@LIGO.ORG - posted 12:01, Tuesday 29 April 2014 (11625)
TCS CO2X output power vs temperature and PZT voltage

Aidan, David, Heintze, Thomas, Greg.

Yesterday, to map out the response of the CO2X laser as a function of PZT voltage and temperature, we drove the PZT on the CO2X laser with a 30V amplitude, 50mHz triangle wave whilst increasing the temperature slowly. The resulting phase space is mapped out in the attached density plot. By noting when the laser mode hops (at a given length of the cavity), we mapped out lines of isolength. They have slope of 1.25mK/V - this implies that a 1.25mK change in temperature of the laser yields the equivalent length change to a 1V change in the PZT voltage.

The PZT voltage has a range of 70V. Therefore, the PZT can compensate for a change in temperature of 87.5mK, or +/- 44mK.

Images attached to this report
H1 SYS
margot.phelps@LIGO.ORG - posted 11:49, Tuesday 29 April 2014 (11624)
Contamination Control Update
Contamination Control Supplies Area Reorganized:
The CC Supplies area in the entrance to LVEA has been re-organized and supplies clearly labeled. 
The heavy use supplies like wipes and foil are in the most obvious and easy to grab location. 
NOTE: The different types of pre-saturated and dry wipes are not interchangeable. General rule of thumb is only use the red pre-saturated or dry Vectra Alpha wipes on Class A parts. (Rest are for "gross cleaning" and floor mop.) The supply shelf is labeled with which one to use, if in doubt ask Jeff B. or Margot.   
The more advanced cc tools like the witness wafers, PET swipe tool, 1'' optics or Top Gun ionizers should only be used by experienced operators. If you think your work in the LVEA cleanrooms/chambers would benefit from using these, contact Jeff Bartlett or Margot Phelps first for assistance. 

Contamination Control work in HAM chambers with Jeff B.:
We are utilizing the new PET swipe tools to track surface contamination during install in HAM4-6. Yesterday Jeff B. took swipe samples of the tables in HAM4, HAM5 and HAM6. We will replicate this at the start of different in-chamber activities to track surface particulate through different install tasks. 
Also plan on chamber inspection and any necessary cleaning of these HAM chambers this week, whenever we can get in there to do so.    
H1 AOS
jeffrey.bartlett@LIGO.ORG - posted 11:02, Tuesday 29 April 2014 (11622)
OPS: reset of HEPI L4C Accumulated WD Counters Tuesday 29th April 2014
Reset WD counters on HAM3, HAM4, BS, & ETMX
H1 CDS
david.barker@LIGO.ORG - posted 10:50, Tuesday 29 April 2014 (11621)
h1build controls password change

h1build controls account password is now the same as the workstations' controls password.

H1 AOS
jeffrey.bartlett@LIGO.ORG - posted 10:19, Tuesday 29 April 2014 (11620)
Morning Meeting Minutes
LVEA Laser Safe

Jason – Set up at HAM6 for SR2 alignment.
TCS Crew – Working on TSC-X table
Apollo – Installing bellows between BSC1/BSC3& TCS-Y/TCS-X
Gerardo - Soft close GV5 and GV7
Justin - Shutter PSL & ALS lightpipe	
Thomas & Patrick – Debugging TCS-X rotational stage 
Richard – Y-Arm ESD cabling
Rick, Peter, Chris, & Justin – H1-PSL cleaning & alignment work
Jeff – Quad & BS Front end model changes
 
LHO VE (VE)
gerardo.moreno@LIGO.ORG - posted 09:50, Tuesday 29 April 2014 (11619)
Soft Closed Gate Valves

Soft closed GV5 at 9:10 am, and GV7 at 9:20 am.  They are to remain soft closed for TCS viewport work at BSC1 and BSC3.

H1 SEI
jim.warner@LIGO.ORG - posted 09:46, Tuesday 29 April 2014 (11618)
HEPI currently having issues at ETMYf

Yesterday, Patrick found HEPI tripped at ETMY. His plots showed the HEPI L4C's rung up. We've been chasing problems there for a while dealing with pier amplification. This morning, I tried bringing HEPI back up and found that the HEPI L4C's would ring after bringing HEPI and the ISI up. My attached plot shows HEPI L4C spectra for the whole chamber isolated  in dashed blue (HEPI on position loops, ISI on level 3 isolated), HEPI postion loops on, ISI damping in green and HEPI off with the ISI isolated in red. Maybe we have a problem with the HEPI loops?

Images attached to this report
H1 CDS (DAQ)
david.barker@LIGO.ORG - posted 08:40, Tuesday 29 April 2014 (11617)
CDS model and DAQ restart report, Monday 28th April 2014

no restarts reported.

H1 AOS
matthew.heintze@LIGO.ORG - posted 19:37, Monday 28 April 2014 (11615)
TCS/HWS update

The AOS people and Vern

HWS table has been moved into a rough position in front of HAM4 so that the buildup of that table can commence. The HWS shipment has been received from Caltech so work can commence on this table

 

Vern had a look at the TCSx Beckhoff controlled HWP and its issues of it not rotating correctly. Its still unfortunately not working correctly and so he has some ideas to try and they will be looked into tomorrow

 

We have been looking into the alignment of the polarisers, we may be seeing evidence of birefringence occurring after the first polariser (not sure what due to), but we need to do some more investigation before making any definitive statements.  

H1 ISC
sheila.dwyer@LIGO.ORG - posted 18:57, Monday 28 April 2014 - last comment - 05:32, Tuesday 29 April 2014(11614)
X arm locking on side of fringe

Today I spent some time working on the automation of the dither alignment using guardian.  I think this should be working OK now, we can try using it for a while and see how this goes.

We need a signal to keep the X arm on resonance when we are working with the Y arm, because the michelson signal contaminates REFL_9 when ITMY is aligned.  Today I switched the refl bias path over to using the transmitted X arm power to lock on the side of fringe.  The attached screenshot shows the settings in the LSC matrix.  Stefan had the nice suggestion of using schmidt trigger to acquire this.  The transmitted power is normalized already, so the calibration into Hz is just multiplying by the FWHM of the cavity, 84Hz., done is LSC REFL BIAS. The offset in this filter determines where we are on the fringe. 

The gain is now set to give this path a crossover with the ALS COMM signal at 35 Hz, (Kiwamu's simulations have us using 30Hz crossover for this).  The gain of this path is attached. 

Images attached to this report
Comments related to this report
michael.zucker@LIGO.ORG - 05:32, Tuesday 29 April 2014 (11616)
Schmitt trigger?
Images attached to this comment
LHO General
patrick.thomas@LIGO.ORG - posted 18:02, Monday 28 April 2014 (11610)
Ops Summary
CDS workstations were frozen and not accepting logins. Cyrus fixed this with a reboot of cdsfs0.

08:52 Jeff and Andres to set up dust monitors near HAM 4,5,6
09:15 Hugh to HAM4
09:24 RO in alarm, sent email to Ski
09:56 Hugh out of HAM4, HEPI is locked, doors are still on
10:24 Matt, David working on TCS HWS table
10:46 Travis heading out to LVEA test stand area, cleanup work
10:52 Email from Ski, RO is fixed
10:53 Richard into H1 diode room
11:09 Jeff looking for serial cables near HAM1, HAM2
11:16 Hugh to lock HAM4 ISI
11:57 Hugh out of HAM4, ISI is locked
12:14 I reset the WD for the BS ISI, Guardian brought it back
?     I reset the WD for ETMY HEPI
12:27 Richard to end X to look at power supply
12:31 Monthly phone test of Hanford site emergency alert system
12:35 Jeff done installing dust monitor at HAM4 at location 1
12:47 Karen to end Y to clean
12:59 I ran the script to isolate ETMY HEPI to level 1
13:34 I restarted the video4 computer and the FOMs
13:37 Justin transitioned the LVEA to laser HAZARD
13:37 Karen back from end Y
13:42 Vern, Matt and David working on TCS rotation stage in LVEA
13:51 I reset the WD for ETMY HEPI. I ran the script to isolate ETMY HEPI to level 1
13:56 Jeff installed a dust monitor at location 6 inside the clean room over HAM 6
14:05 Richard to end X to look at high voltage supply
14:58 Richard back from end X, working on dust monitor in diode room
H1 ISC
alexan.staley@LIGO.ORG - posted 16:54, Monday 28 April 2014 - last comment - 17:19, Monday 28 April 2014(11611)
EY Cavity Length Measurement

(Daniel, Alexa)

Today we measured the EY cavity length. We repeated the technique described in alog 9626. We ran the measurement three times. And got the following results:

Offset Zero Crossing (MHz) Length (m)
0.0V 24.992280 3994.4690
0.0V 24.992281 3994.4688
-2.5V 24.992277 3994.4695

where the offset refers to the common offset in the PDH REFL servo board. The results of each attempt is plotted respectively. (I have also attached the data and the matlab script that creates the plots and gives the values listed in the above table). This gives:

Zero crossing freq = 24.992280MHz ± 5Hz

EY Arm Cavity Length = 3994.4691m ± .7mm

If we compare this to the result for EX, we find that the cavity lengths differ by 1 ± 1mm. 

Non-image files attached to this report
Comments related to this report
daniel.sigg@LIGO.ORG - 17:19, Monday 28 April 2014 (11613)

The nominal y-arm length according to Jason is 3994.4728 ± 0.004 m, about 3.7 mm off the measured value and well within the error bar.

The x-arm length can be found in alog 9626.

H1 AOS (SUS)
richard.mccarthy@LIGO.ORG - posted 15:28, Monday 28 April 2014 - last comment - 11:21, Tuesday 29 April 2014(11609)
ETM-X ESD Problems with Power Supplies
The ESD was non-functional this morning when we tried to operate it.  I went down to EX and found the negative supply in the off state (indicating a trip probably not someone shutting it off).  Turned it on went out to ESD drive to turn it on.  As soon as I turned on ESD amp the Neg. Power supply tripped off.  Went back out to power supply to see if I had not set the over current.  The unit was off again. This time it would not turn on.  Took this opportunity to swap out bot the positive and negative supplies.  The positive due to problems noted last week with sync. and the neg. do to this failure.  Power the system back up.  The system once again was in an odd state all of the supplies present but sitting at a neg rail.  I verified voltage everything was properly connected but still at a neg. rail.  This was the same state the unit was in on Friday when I had Kiwamu come out to help.  I disconnected the DAC inputs and reconnected them.  Everything came up just fine.  This is a very troubling state as the DAC was not sending out a voltage and the unit was behaving as though it was.

The unit is now running and seems to be working again.
Comments related to this report
kiwamu.izumi@LIGO.ORG - 11:21, Tuesday 29 April 2014 (11623)ISC

This is just a followup of the ETMX ESD power supply failure.

It seems that the power supply became non-functional (or at least the HV amp started generating zero voltage) in the evening of this past Friday which is the day we activated the ESD for the first time on ETMX.

  • Apr.25 18:00 UTC  - We started using the ESD with a bias count of -125 k counts.
  • Apr.25 18:45 UTC  - The swept sine measurements were over. The DC bias was left on at -125 k counts.
  • Apr.26 00:29 UTC  - The readback ADC started reading zero voltage while the DAC still kept sending -125 counts. The readback remained zero until Richard did some activities yesterday.

The DC bias was the only channel which had a non-zero value and all the other quadrants was not doing anything at the time of the failure. A trend of the DC bias and its readback is attached.

Images attached to this comment
H1 General
jeffrey.bartlett@LIGO.ORG - posted 14:40, Monday 28 April 2014 (11608)
PET Swipe Samples
Took PET swipe samples:
 (1). Center of HAM5 ISI from the north side door.
 (2). End of HAM6 ISI near east door. 
 (3). Just south of Center of HSM4 ISI from the south door.  
H1 General
jeffrey.bartlett@LIGO.ORG - posted 14:34, Monday 28 April 2014 (11607)
Add New Dust Monitors
Added two new dust monitors to cover the installation and alignment work at HAMs 4,5 & 6. 

   Loc #1 is at the South side door of HAM4.
   Loc #6 is at the East side door of HAM6. 

H1 SEI
patrick.thomas@LIGO.ORG - posted 13:19, Monday 28 April 2014 (11606)
Plot of L4C WD trip for ETMY HEPI
Plot attached.
Images attached to this report
H1 ISC (ISC)
stefan.ballmer@LIGO.ORG - posted 13:16, Monday 28 April 2014 (11605)
H1ECATY1PLC2 now controlled by CSD (Control State Definition)
I updated the H1ECATY1PLC2 xml file with the required manual setting to be compatible with the autolockers, and turned it on.

All of the original four CSD prototype targets (H1ECATX1PLC2 H1ECATY1PLC2 H1ISCEX H1ISCEY) are now running.

I also stood up the infrastructure for the CSD for H1LSC and H1LSCAUX - this was literally just running the commands:

./createCSD H1LSC lsc /ligo/cds/lho/h1/burt/2014/04/28/12:00/h1lscepics.snap
./createCSD H1LSCAUX lsc /ligo/cds/lho/h1/burt/2014/04/28/12:00/h1lscauxepics.snap

followed by adding the systems to the CSD main screen.