Displaying reports 72841-72860 of 84073.Go to page Start 3639 3640 3641 3642 3643 3644 3645 3646 3647 End
Reports until 13:20, Friday 25 April 2014
H1 SUS (INS, SUS)
richard.mccarthy@LIGO.ORG - posted 13:20, Friday 25 April 2014 (11573)
ETM-X ESD Power up
Finally installed all of the cabling and interlock boxes for the ESD drive.  There is a short cable at the feed through that goes to a current limiting resistor box.  From that box a 5 conduct cable with SHV connectors goes to the ESD amplifier.   The ESD amplifier has +-430V dc and +-18v dc supplied to it.  The HV supply is interlocked to a Vacuum gauge on the chamber.  

One item of note for the installation is the SHV coax cable label 1 goes to ESD amp port 3 and Coax cable 3 goes to ESD amp port 1.  I have used sharpie to mark this.

If the vacuum gauge trips the HV supply or if we have a power outage the HV supplies need to be switched on by hand.  The +430 Volt supply was found in Sink mode.  I am not sure how it arrived in this state because you would have to program the unit to do this and when the unit was turned on this was not done.  WE WILL have to track this to see if it is a problem. 

Before connecting the unit to Vacuum I checked the output values.

With See Table on attached pdf


								

Non-image files attached to this report
H1 SEI (INS)
hugh.radkins@LIGO.ORG - posted 12:08, Friday 25 April 2014 (11572)
WHAM5 SEI Activity/Status--Locked; ISI Off, HEPI Sensors On
HEPI was locked(put on stops) a couple days ago but its sensors remain on.  At the same time, the ISI interface electronics were powered down to allow decabling the air side.
This morning the ISI was locked (with lockers) and then the 800lbs of dummy payload was removed to make room for Suspension installs.
Thanks to Apollo Scott, Mark & Bubba.
H1 SEI
sheila.dwyer@LIGO.ORG - posted 12:04, Friday 25 April 2014 (11571)
still logging trips

ITMX tripped, this might have been a result of Jim's measurement, but I am not sure. 

 

The gps time was 1082487591

H1 ISC
daniel.sigg@LIGO.ORG - posted 10:14, Friday 25 April 2014 (11570)
RF amp added to COMM PLL BBPD

A ZFL-500LNB+ Mini-Circuits amplifier was added to the output of the COMM PLL BBPD. It is mounted directly to the output connector of BBPD using a SMA barrel. This amplifier was measured to have 29dB-30dB of gain in the 80MHz frequency range. Currently, there is a power supply on top of the enclosure. Longer term, we want to splice this into the +/-15V supply running to the BBPD. All other amplifiers were removed from the path.

H1 General
andres.ramirez@LIGO.ORG - posted 09:15, Friday 25 April 2014 (11569)
Installation Meeting Minutes
8:15-8:35

Mike, Terry, Pablo, Daniel, Steban, Vern, Justin, Richard, Bubba, Kiwamu, Jim, Hugh, Mark, Jason, Aaron, Mitchell, Mark B., Keita, Jeff K.

LVEA is Laser HAZARD

HAM4- Cleaning crew in action – Karen and Chris
Craning activity by APOLLO
HAM5 ISI:  Removing payload –Hugh/Apollo 
TCS tables work continues. David/Aidan
TCS racks work at end stations (Richard & crew)
3ifo BSC ISI assembly  work continues in Staging Building – Mitchell
Dust monitors work at end stations. Switching the dust monitor unit in diode room. Jeff B.
H1 CDS (DAQ)
david.barker@LIGO.ORG - posted 08:28, Friday 25 April 2014 (11568)
CDS model and DAQ restart report, Thursday 24th April 2014

no restarts reported.

H2 SEI
mitchell.robinson@LIGO.ORG - posted 08:08, Friday 25 April 2014 (11567)
Staging building, 3IFO (unit 2) progress
Jim and I pulled/pushed all of the blade springs and installed flexures on unit 2 yesterday. Parts needed for unit 3 were discovered to be short of needed quantities have been ordered.
H1 ISC
stefan.ballmer@LIGO.ORG - posted 19:22, Thursday 24 April 2014 - last comment - 19:44, Thursday 24 April 2014(11565)
Working towards diff
Alexa, Sheila, Stefan

Our goal today was to get a good diff readout going. For this we
- Commissioned the IMTY and ETMY optical levers, See snapshot.
- Recommissioned the x-arm dither - turns out the phases were tuned up for a different suspension setting - we need configuration control on all the suspension settings. Also see the snaphot.
- With that we got fairly stable arm locking - at least for a while - see below.

- Next we tweaked up the DIFF beat note on ISCT1. We got -20dB signal out of the PD.
- Th PLL locked for short stretches, but essentially always runs out of range after a few seconds.

- Thus we decided to work on top-mass slow feed-back: There was a lot of confusion, but once everything was done right, it sort of worked.
- One thing we noticed along the way, is that our 1-3Hz BLRM traces pick up increases in noise with an roughly hourly periodicity. This noise somehow translates into extra length motion at 0.05Hz. 
- We also fine-tuned the ETMY top mass L2P filter - see Arnaud's log
- The slow feed-back gain was however limited by our main suspension resonance, which meant that we couldn't suppress the DIFF motion enough.
- We thus decided to work on the L2L filters, which should give us the ability to increase the UGF of that loop and get more suppression.
- We got a simple L2L measurement going, but more work is needed.
Images attached to this report
Comments related to this report
arnaud.pele@LIGO.ORG - 19:44, Thursday 24 April 2014 (11566)

Stefan tweaked the L2P decoupling filter to improve (even more!) the top mass to test mass length to pitch decoupling. Basically, the Q of the first resonance of the filter was reduced from 16 to 12.5, (see difference in the attached plots) and this helped reducing the pitch motion, while driving in length, by a factor of ~2. The new filter is loaded in the L2P M0 drivealign matrix bank, and named L2PQ12.5. The old filter is loaded in FM6 as L2P1legacy.

Images attached to this comment
H1 SEI
sheila.dwyer@LIGO.ORG - posted 19:09, Thursday 24 April 2014 (11563)
ETMY ISI

Something is wrong with ETMY stage 2 RX Tbetter....  we clearly have less opLev peak to peak when we turn this to Tcrappy. 

So the configuration we are using now is Tbetter everywhere except Tcrappy on RZ on stage 1 +stage2, and Tcrappy on stage 2 RX, sesnsor correction from the ground to stage 1 in X Y and Z. 

We also briefly tried T750 on stage 1 Z motivated by llo alog 12164, this wasn't good so we will have to do a more thoughfull job of importing those improvements.

H1 SUS
arnaud.pele@LIGO.ORG - posted 18:50, Thursday 24 April 2014 (11555)
ETMY UIM modified coil drivers

Yesterday, the modified UIM coil drivers for ETMY and ETMX were tested in-situ. The transfer functions are showing an average drive increase of ~3.8 for ETMY and ~3.9 for ETMX comparing them before and after, which corresponds to the modification as described in T1400223.
A second test was carried out, using the monitor boards current channels. The test consisted in sending the equivalent of 1V to the coil drivers, to each of the UIM osem channels, and recording the current increase with channel ${QUAD}_L1_FASTIMON_${OSEM}. Jeff K helped me for the calibration of those channels.

The output voltage of the "fast current channel" of the monitor board as described in T1100378 is measured across the resistor Zout. The relation between the current and the ouput voltage is described in the last equation of Jeff's notes attached, with R1/R2 = 1/3 and Zout = 2010 ohms. In other words Current_readback_calibrated (A) = FASTIMON_Readback (cts)* 1/1638.4 (V/cts) * 3/2 * 1/2010 (ohms-1)

For ETMX I measured a transconductance of ~0.6 mA/V for each channel which matches pretty well with the design, but for ETMY it didn't quite match. First, only two channels (even though the mass was moving) were seeing a response, and secondly, the working channels were showing ~3mA increase for 1V drive. Since the transfer function shows that the driver is working as expected we certainly have something going on with the monitor board.

The non functioning channels are LL and UR osems. For UL and LR, when no voltage is sent to the coil driver, the readback sees ~4000 cts (as shown on the screenshot).
 

Images attached to this report
Non-image files attached to this report
LHO VE
kyle.ryan@LIGO.ORG - posted 16:03, Thursday 24 April 2014 (11564)
~1515 hrs. local -> "Burped" unpumped volume seen by PT246B into adjacent RGA volume


			
			
H1 AOS
corey.gray@LIGO.ORG - posted 16:00, Thursday 24 April 2014 (11556)
Ops DAY Summary

Days Activities

 

H1 SEI (SEI)
corey.gray@LIGO.ORG - posted 13:15, Thursday 24 April 2014 (11561)
OPS: reset of HEPI L4C Accumulated WD Counters Thursday 24nd April 2014

Went through the Operator check of saturations with HEPI this afternoon.  The HEPI Saturation Counters which I had to reset were: 

HAM2, HAM4, ITMx(BSC3), ITMy(BSC1), ETMx(BSC9), ETMy(BSC10)

LHO VE (VE)
corey.gray@LIGO.ORG - posted 12:12, Thursday 24 April 2014 - last comment - 13:56, Thursday 24 April 2014(11559)
MY Pressure Sensor Alarm Level Changed

A pressure sensor at MY had been MAJOR Alarming the last few days, but this is due to it being worked on.  It will be displaying values of a higher pressure for a month or so while it is valved out and being worked on.  To prevent getting alarms from this, we've bumped up the MAJOR alarm setting to 1x10^-6 (originally it would alarm at 5.11x10-8).

Since the Vacuum computer was really slow, Dave ssh-ed into the computer (still was slow) & did the following:

vacuum@control0:~$ caget HVE-MY:Y5_246BTORR.HIHI
HVE-MY:Y5_246BTORR.HIHI        5.11e-08
vacuum@control0:~$ caput HVE-MY:Y5_246BTORR.HIHI 1.00e-06
Old : HVE-MY:Y5_246BTORR.HIHI        5.11e-08
New : HVE-MY:Y5_246BTORR.HIHI        1e-06

We must revert the alarm setting when the VAC work is complete.

Comments related to this report
corey.gray@LIGO.ORG - 13:56, Thursday 24 April 2014 (11562)VE

OK, 1e-6 wasn't good enough (Kyle started baking out RGA components today & this shot up the pressure on this sensor).  John said I could up the Alarm setting to 1e-05, and if it alarms here, then the VAC crew will just power OFF the sensor.

LHO VE
kyle.ryan@LIGO.ORG - posted 11:57, Thursday 24 April 2014 (11560)
~1130 hrs. local -> Began baking portable RGA currently mounted at Y-mid on the Y2-1 beamtube port
Baking will continue for as long as a few weeks
H1 SEI (SEI)
hugo.paris@LIGO.ORG - posted 10:55, Thursday 24 April 2014 (11557)
HEPI safe.snap corrected

HEPI safe.snap files had the wrong ..._L4C_THRESH_MAX values recorded, as pointed out by Dave yesterday. Those safe.snap files are now fixed. The new versions are committed under the SVN -r7796.

Details are attached.

Non-image files attached to this report
H1 SEI (INS)
hugh.radkins@LIGO.ORG - posted 10:53, Thursday 24 April 2014 (11558)
WHAM6 SEI ISI Electronics Powered Down--for access to WHAM6 Bellows retraction Bolts

The Apollo crew was unable to get wrenches to the large clamp bolts which retract the bellows of the chamber's west side 60" flange.  We needed to remove the Feedtrhu protection shroud and the cabling attached to the feedthru.  So the WHAM6 isi interface electronics were powered down.

H1 CDS (DAQ)
david.barker@LIGO.ORG - posted 08:54, Thursday 24 April 2014 (11554)
CDS model and DAQ restart report, Wednesday 23rd April 2014

model restarts logged for Wed 23/Apr/2014
2014_04_23 08:46 h1nds1
2014_04_23 08:53 h1fw1
2014_04_23 09:03 h1broadcast0

2014_04_23 10:02 h1asc
2014_04_23 11:06 h1susmc2
2014_04_23 11:29 h1susprm
2014_04_23 11:38 h1sussrm
2014_04_23 11:52 h1susmc1
2014_04_23 12:01 h1susmc3
2014_04_23 12:11 h1suspr2
2014_04_23 12:18 h1sussr2
2014_04_23 12:58 h1suspr3
2014_04_23 13:08 h1sussr3

2014_04_23 13:16 h1broadcast0
2014_04_23 13:16 h1dc0
2014_04_23 13:16 h1fw0
2014_04_23 13:16 h1fw1
2014_04_23 13:16 h1nds0
2014_04_23 13:16 h1nds1

no unexpected restarts.

Displaying reports 72841-72860 of 84073.Go to page Start 3639 3640 3641 3642 3643 3644 3645 3646 3647 End