Re-did measurements from yesterday. Daniel brought up point about green light leaking into IR measurements and vice versa. So addressed this.
IR Laser Light: Look At filters to attenuate IR
Here we wanted to see which filter was best for viewing the GREEN light, so we wanted the filter which passed green & cut out IR. With the Prometheus laser we used its IR light. To make sure there was no Green light, we dropped in a Hoya R72 filter (to remove any Green light from laser). Then we looked at the filters I bought . So this is what we had:
The BP550 is OK, but Daniel says the OD of this filter may be low and we should look for a Schott glass filter (order of 4mm thick, similar to our old iLIGO glasses). Either that or we can see what a couple of the BP 550s filters look like in series.
GREEN Laser Light: Look At filters to attenuate Green
Here we want to see which filter is best for viewing IR light, so we want a filter which passes IR & attenuates Green. With the Prometheus laser we had green light. To make sure there is no IR light leaking in, we dropped an iLIGO goggle in the beam path as a filter.
LP 920 may be good...maybe have two in series?
Alexa, Stefan - With the y-arm o.k. (the remaining glitches were actually bleeding in from x-arm locking), we realigned the x-arm. - Note: we need to switch back to a better camera view for the x-arm transmitted light. The current one does not provide a lot of information because a) it is completely saturated and b) it is in a guoy phase that is not very sensitive to TMS alignment. - Once we had both arms aligned and locking fairly reliable, we looked at the DIFF electronics: - First we found 3 switches on the VCO and FDD that were left off. - Next we noticed that the DIFF beat note was only -32dBm - we verified the EPICS read-back with the scope. - So we hooked up the scope on ISCT1, but right then an earthquake struck and knocked out every ISI on site. Thus we went home.
The earthquake was reported as a 6.7 94km S of Port Hardy, Canada (Vancouver Island), at 2014-04-23 20:10:13 UTC-07:00
Today we were able to lock the y arm for a significant period of time. Here are some settings:
PDH REFL Servo Board:
I took a few measurements:
Note: Stefan has since changed the input gain to -13dB and the fast gain to 6dB. The overall UGF and loop shape is the same. See alog 11547
I created a script, createCSD in sys/common/scripts, that sets up all required files and code for implementing a new instance of the control state definition. I also improved the makeMEDMfromOUTXML.py somewhat when dealing with sub-states. createCSD takes the following three inputs: createCSD SYSTEM systemhome snapfile SYSTEM has to be the capital version of the system name, i.e H1ISCEX or H1ECATX1PLC2 systemhome is the system subdirectory name in userapps, i.e. something like als, isc, isi, lsc, omc, pem, psl snapfile is the initial snapshot setting that will be enforced. If not specified, the default safe.snap will be used It uses a burt snap file to create a very simple xml file with no states. Running this xml file will simply continously enforce that snapshot file. Any further modifications can then be done manually in the xml file. Using this I stood up CSD-Guardians for H1ISCEY and H1ECATY1PLC2. I also manually created the same states for H1ISCEY as we have for H1ISCEX, so H1ISCEY is ready to be used. I haven't done the manual edits for H1ECATY1PLC2. I left H1ISCEX, H1ECATY1PLC2 and H1ISCEY running in OP. H1ECATY1PLC2 was left with the Guardian paused.
Alexa, Pablo, Keita, Stefan We noticed that H1:ALS-Y_VCO_TUNEMON and H1:ALS-Y_VCO_FREQUENCY were only reacting to half the range of the drive from the common mode board (H1:ALS-Y_REFL_SERVO_FASTMON). We thus swapped the EX VCO ( D0900605 , S1200562 ) with a H2 spare ( S1200566 ). This fixed the issue. Next we noticed that the PDH signal doesn't bring the arm power to a maximum. With a H1:ALS-Y_REFL_SERVO_IN1GAIN of -13dB, and an H1:ALS-Y_REFL_SERVO_COMOFS of -4.75V we get the maximum build-up, about 1750 counts of H1:ALS-C_DIFF_A_LF_OUT_DQ. With a misaligned ITM Keita and Alexa verified that it is not an RFAM effect. We still see transients in the arm build-up.
Jim and I have been investigating DAQ issues with HEPI ETMY which started over the weekend. Brian noticed that HPI ETMY's L4C Sat Counter started looking like the WD threshold, and was also counting down from 89k to 30k which it should no longer need to do.
We are unsure about the details, but it appears that when Jeff restarted h1hpietmy at 15:02PDT Saturday afternoon , the old INI file was archived but the newer file was used. It would appear that the INI Checksum the FE sends to the DAQ was calculated from the archived file, so DAQ did not show a 0x2000 error for this model. At a later time of 18:50PDT Saturday Jeff restarted the DAQ, at which point the FE DAQ status went to 0x2000 and the data in the DAQ was mixed up (resulting in a WD threshold being named the Sat Count). When I pressed the "DAQ RELOAD" button for HPI ETMY monday morning at 10:24PDT the FE and DAQ synced up and the DAQ data became good again.
When the model was restarted on Sauturday it read the safe.snap file which set the WD threshold level high, hence the ramping back down to 30,000. The safe.snap is being corrected by Brian and Hugo.
I had to "DAQ RELOAD" h1hpibs on monday as well, so it could have the same issues over the weekend.
We suspect the fact that the make-install and model restart occured very close to each other may be a possible cause of the INI file mismatch, but this is pure speculation.
If commissioners suspect any DAQ issues with h1hpietmy and h1hpibs we should restart the models.
J. Kissel I've modified all HAM SUS front end code to receive dither alignment signals from the ASC front end. Currently, however, the sending channels have dummy constants as input at the top level of the h1asc model, because there's work internal to the ASC library block that needs doing. I leave the ASC model changes in the very capable hands of the ISC team. Thankfully, recovery was easy from these changes went much more smoothly than Monday's. We had no guardian machine failures or IOP DAC FIFO errors, and the MC REFL path stayed put. As such, once we went back to laser hazard, the IMC popped right back into business. Obviously, everything went smoothly because plenty of relevant parties were here on site. #sarcasm I have not yet begun to make the necessary MEDM screen modifications (which is how I was able to get through the changes so fast). I'll begin doing so in a bit and post shots later. I also have not committed any of the changed library parts mentioned below, because I'm not sure yet how LLO would like to roll out these past few days of changes. However, all top level models have been committed, since they don't affect LLO. Details ----------------- Of the list of front end models mentioned this morning, I got through h1asc SUS top-level models: h1susprm h1suspr2 h1suspr3 h1sussrm h1sussr2 h1sussr3 h1susmc1 h1susmc2 h1susmc3 SUS library parts: FOUROSEM_STAGE_MASTER FOUROSEM_STAGE_MASTER_OPLEV SIXOSEM_T_STAGE_MASTER HLTS_MASTER HSTS_MASTER MC_MASTER Though the IMC models do not receive dither, they use the HSTS_MASTER and MC_MASTER parts, so the dither inputs had to be terminated at the top level. Minor mod, but still a mod. I've also added place-holder IPC receivers to the top level of all BS, and all QUAD models, but they're terminated at the top level, since I've not yet made changes to the QUAD or BSFM library parts. I attach lots of screenshots of the affected simulink models, to show how I've implemented the path.
The y-arm was locked to a seoncd order mode. The transmitted power was 4uW, whereas it is 30uW for the fundamental. This gives a rough estimate of the mode matching with ~13%.
JeffK doing model updates all day, various IMC sus's and isi's going down, then up.
8:45 Heintze and Hosken to LVEA for TCS work
9:00 Jodi moving stuff in the LVEA west bay
9:00 Justin transitions LVEA to laser safe
9:00 JeffB, Hugh, Patrick to HAM5 for HEPI lock up
9:00 Alexa and Apollo Mark to H1 PSL area to move carts for fork lift access
9:15 Gerardo soft-closes GV5&7
10:00 MarkB and Gerardo to H2 PSL for OFI work
10:15 TVo to LVEA
10:30 Jodi to Y-Mid
12:30 Fil to EX for cabling
12:30 Travis to LVEA test stand area
13:00 Karen to EY and MY for cleaning
13:00 Margot to EY looking for equipment
13:00 Heintze and Hosken back to LVEA TCS
13:00 Gerardo opening GV5&7
13:30 TVo to LVEA for Oplev work
13:30 Travis to HAM3 for mobility camera work
13:30 JeffK and Dale to LVEA with tour
14:00 TVo to EX and EY
14:30 LVEA Laser Hazard
15:00 Aidan to LVEA for TCS
15:00 Alexa at EY
I changed the group permissions of all files under the /opt/rtcds/userapps/release area to permit individual accounts modification access to these controls owned files. Please report any file permission problems to me, thanks.
This is the first step in implementing this change. Not all users accounts belong to the controls group.
I restarted the DAQ at 13:12PDT today to support SUS and ASC model changes made this morning.
h1dc0 monit did not restart the daqd process after I shut it down. I logged into h1dc0 as root and restarted monit (which seemed to be running) which in turn started the daqd process.
After the DAQ restart h1susprm and h1suspr3 showed a 0x2000 DAQ error. I pressed the DAQ RELOAD button on their GDSTP MEDM screens and cleared the error.
Mark B. and Gerardo
Yesterday (4/22/14) Gerardo and I measured the vertical mode Q of the OFIS for three different positions of the ECD block to try to get the Q in the specified range of 25-30.
The OFIS was set up on the optical bench in the H2 laser enclosure. The ECD block sits on a tray below the payload which is supported by four groups of vertically pointing screws at accessible positions around the edge of the structure. Gerardo had earlier attempted to set the ECD block at the nominal height using the spacer tool provided but found that this was too high and caused interference. He therefore lowered the block until it was just barely clear plus approximately an extra two turns of the 1/4-20 screws. This was our starting point for further adjustments.
To measure the vertical Q, we used the laser pointer and QPD from the monolithic violin mode setup and used a convenient screw on the top of the payload to partially block the beam. We displayed the "pitch" output of the QPD box on a digital oscilloscope with a 1 sec/div timebase and photographed the screen to capture the data. I read off the peak positions with GraphClick, and worked out the logarithmic decrement and Q with Mathematica.
For the initial position, the Q was 10.7. We lowered the ECD by one turn on all the screws and got Q = 18.9. We lowered the ECD another half turn and got Q = 23.3. Finally, today (4/23/14) we lowered the ECD another 3/4 turn and got 27.8, which is in spec.
Attached is a JPG of the setup, a PDF of all the screenshots, and for the fourth and final run, the Mathematica notebook, PDF thereof and the raw data.
We went back on Friday 4/25 and used the same method to measure the longitudinal (parallel to the OFI beam axis) and transverse mode Qs. For the longitudinal measurement we were able to keep the laser in almost the same position, just clipping a different edge, but for the transverse we had to send the beam on an odd diagonal path clipping one corner and then passing through the hole in the beam dump at the end (see photo). The results were
L: 21.3
T: 15.3
V: 27.8 (from 4/23, above)
The spec is <30 per T1000308-v1, p36, so these Qs look good and we propose to leave it like this.
I measured the gap between the copper plate and the magnets, 4 mm and all 4 corners.
Per request of Jeff Kissel, I extracted the frequencies from the data of 4/23 and 4/25 for the final configuration of the dampers:
In addition, I pulled the Dial Indicators from the East side, Turned off the ISI Sensor/Driver electronics, unplugged all the the East air-side cabling, and removed those Feed-Thru protection shrouds. This will give access to the final bolts of the Septum flange. Be mindful of the CPS Feedthrus on the North side--long and vulnerable.
For the operators or future HEPI Lockers, attached are trends from before starting thru after stopping the HEPI down. We shoot for < +-200 IPS Counts (655cts/mil) and it looks like we did pretty well here. Also are trends of the Cartesian values. These are nanos(meters/rads) for the horizontal/rotation dofs. We shifted 7um in X, less for Y & Z and 5urads RX and less for RY & RZ. RZ is likely the most important for the upcoming alignments, it shifted 2urads.
Bartlett, Thomas
Notes for Saturation counter bleeding design:
to note: after a day of heavy installation work around this chamber, the HPI L4C WD is still a long way from saturation. I (Brian L) believe that this is not a good day to consider when thinking about the auto-bleed-down rate. This sort of shenanigans should be cleared by an operator - under the belief that if this sort of thing were happening to the HPI, then someone should know about it.
Soft closed GV5 at 9:00 am, and GV7 at 9:07 am. They are to remain soft closed for TCS table work near BSC1 and BSC3.
Valves are open now, GV5 and GV7 were open by 1:37 pm.
This is a tabletop photodetector interface (D1002932-V5, S1103811) in ISCTEY that was misbehaving yesterday. I opened it and found this.
None of the power connectors for Thorlabs PDs and BBPDs were soldered to the board. And one of the connectors was loose (right-most one in the video). See how the legs move as I wiggle.
It's a miracle that it worked at some point. I soldered all of the connectors.
(If avi doesn't play, try mov file, though the time of the mov file seems to be out of whack.)
I opend and checked two randomly selected "Table-Top" boxes (D1002932-v4) from the twelve boxes in Mid-Y storage, serial numbers S1103796 and S1103810, for quality of build and found them to be in good shape. The front circuit card was soldered onto the panel connectors. All screws and fasteners were tight. The general quality of work looked good. Let's hope the box Keita found (S1103811) was an oversight.
I am about to start upgrading drivers on the DAQ as specified in WP4583. There will be NO DATA recorded during the period when the data concentrator is rebooted - as it is due for a full FSCK at boot, this will be a period of 10-15 minutes. For the remaining system upgrades, there will be intermittent access to the recorded data as those systems (h1nds1, h1fw1, h1broadcast0) are rebooted. Changes to h1nds0 and h1fw0 will happen at a later time. Further updates will be posted to this entry with specific downtime.
DAQ Downtime Report
h1dc0: 16:07:40 - 16:18:00 UTC There is NO data recorded by the DAQ during this period.
h1nds1: 16:26:00 - 16:28:20 UTC
h1fw1: 16:33:55 - 16:55:50 UTC There is NO data available via h1nds1/h1fw1 for this period. Use h1nds0/h1fw0 for frames ending/starting in this timeframe.
h1broadcast0: 17:06:55 - 17:16:00 UTC
Most installs were uneventful. However, on h1fw1, the MTU was not set to 9000 in /etc/conf.d/net as it is on h1fw0, which prevented daqd from running after restart. I changed /etc/conf.d/net to match and rebooted to fix; I have no idea how it ever worked before. On h1broadcast0, I disabled the items in local.start that are only useful for a data concentrator; h1broadcast0 being a clone of a data concentrator had these unnecessary additions.
Technical Details
(l inadvertently left these out of the original entry)
The change is to upgrade the Myricom ethernet adapter drivers for the DAQ broadcast network to version 1.5.3.p3, compiling them with the MYRI10GE_ALLOC_ORDER=2 option and using the big_rxring firmware at driver load. This is to attempt to reduce the number of dropped frames that are seen occasionally, most often on the framewriters, that also trigger 'retransmission request' errors in the daqd log. And additionally, on the data concentrator to make use of the MYRI10GE_THROTTLE option to see if tuning the packet emission rate has any effect for the receiving systems. The primary method of measuring any change is to use the SNMP monitoring of the DAQ broadcast switch to monitor the dropped/paused frames per host port. The same changes on the test stand indicate some improvement.
So the plan is this.
For Green-viewing camera, we will actually use a 4mm thick KG5 Schott filter (these are on order from UQG Optics in the UK).
For the IR-viewing camera, we actually want to try the LP 550 from the entry above (the LP920 & Hoya R72 will show IR light, but we won't see much else). Since we have one of the LP550s, we can test out this filter now. Want to make sure we can easily install this on the Rainbow zoom lens (without disturbing alignment). If we like it, we can order more of these guys.