H1 TCS (TCS)
aidan.brooks@LIGO.ORG - posted 10:50, Wednesday 23 April 2014 (11528)
TCSX install work - aligned up to polarizer

Aidan, Dave H, Matt H, Greg G.

We aligned the X-arm CO2 laser through the first 40% of the optics on the table, including:

We measured the DE of the AOM as a function of applied voltage (via the front end model). The results are posted in the table below. The AOM is quoted as having a maximum DE of ~85% at the exact Bragg angle.

The Y-arm table laser is ready to test on Wednesday.

Images attached to this report
Non-image files attached to this report
LHO General
corey.gray@LIGO.ORG - posted 10:08, Wednesday 23 April 2014 (11524)
Installation Meeting Minutes

[this is something new.  We would like the Operator to post minutes for the morning meeting]

Morning Installation Meeting Minutes

Attendees:  Vern, Keita, Jeff K, Jeff B, Hugh, Corey, Justin, Jim W, Jodi, Aiden, Mark (apollo), Cyrus, Aaron, Richard, Pablo, John.....(sorry if I'm missing others, this is from memory over an hour after the fact)

Topics Brought Up:

LHO VE
gerardo.moreno@LIGO.ORG - posted 09:35, Wednesday 23 April 2014 - last comment - 13:57, Wednesday 23 April 2014(11529)
Soft Closed Gate Valves

Soft closed GV5 at 9:00 am, and GV7 at 9:07 am.  They are to remain soft closed for TCS table work near BSC1 and BSC3.

Comments related to this report
gerardo.moreno@LIGO.ORG - 13:57, Wednesday 23 April 2014 (11535)

Valves are open now, GV5 and GV7 were open by 1:37 pm.

H1 CDS
cyrus.reed@LIGO.ORG - posted 09:20, Wednesday 23 April 2014 (11527)
DAQ Drivers Reverted

The new drivers installed on the DAQ yesterday as part of WP4583 did not improve performance as expected, and in fact made it worse, so I have rolled back the changes to h1nds1, h1fw1, and h1broadcast0.  I have left h1dc0 as it is since the change there does not seem to have had any ill effects.  It's not clear to me why the same change showed an improvement on the DAQ test stand, other than the traffic level is significantly higher on the production system and must influence the driver behavior or the system configurations have diverged enough to affect the results of testing of this nature.  Here are the downtimes for reboots:

h1nds1:  15:40:35 - 15:45:54 UTC

h1fw1:  15:48:23 - 15:52:30 UTC  Frames starting/ending in this period will be missing - use h1nds0/h1fw0 for data in this gap.

h1broadcast0:  16:00:40 - 16:02:40 UTC

H1 SUS (CDS, ISC, SYS)
jeffrey.kissel@LIGO.ORG - posted 09:09, Wednesday 23 April 2014 (11526)
Beginning Installation of ASC to SUS Dither Paths, ECR E1400105
J. Kissel (Approved by M. Landry, K. Kawabe, V. Sandberg)

I'm taking the opportunity while gate-valves are closed for TCS table moving to install ASC dither alignment IPC channels into all core-optic SUS, (see ECR ). This will replicate what has been done for PR2 (see LHO aLOG 10346). Note, for now (so the SUS models will compile without complaint), I plan to add the IPC sender channels at the top-level of the ASC model, with zeros sent into them, and I'll leave it up to the ISC team to hook them up to their main library block as they wish.

The models affected with be 
(to add new IPC sender parts)
h1asc

(to add new IPC receiver parts)
h1susprm
h1suspr3
h1susbs
h1susimty
h1susitmx
h1susetmx
h1susetmy
h1sussrm
h1sussr2
h1sussr3

[because it uses the HSTS_MASTER, MC_MASTER library part, so new unused inputs must be terminated]
h1susmc1
h1susmc2
h1susmc3

(to add dither paths to each stage of each SUS type)
SIXOSEM_F_STAGE_MASTER
FOUROSEM_STAGE_MASTER
FOUROSEM_STAGE_MASTER_OPLEV
SIXOSEM_T_STAGE_MASTER
QUAD_MASTER
BSFM_MASTER
HLTS_MASTER
HSTS_MASTER
MC_MASTER

Work beginning 
1082304916
2014-04-23 16:15 UTC
2014-04-23 09:15a PDT

I'll make sure to capture a new h1asc_safe.snap before getting started. 
H1 CDS (DAQ)
david.barker@LIGO.ORG - posted 08:15, Wednesday 23 April 2014 (11523)
CDS model and DAQ restart report, Tuesday 22nd April 2014

model restarts logged for Tue 22/Apr/2014
2014_04_22 09:14 h1dc0
2014_04_22 09:15 h1broadcast0
2014_04_22 09:15 h1fw0
2014_04_22 09:15 h1fw1
2014_04_22 09:15 h1nds1
2014_04_22 09:16 h1nds0
2014_04_22 09:29 h1nds1
2014_04_22 09:40 h1fw1
2014_04_22 09:53 h1fw1
2014_04_22 10:10 h1broadcast0
2014_04_22 10:16 h1broadcast0

no unexpected restarts.

H1 ISC
corey.gray@LIGO.ORG - posted 22:01, Tuesday 22 April 2014 (11522)
Checking First Batch Of Camera Filters for ITM Spool Cameras

There is a desire to have Spool cameras looking at the ITMs--One to show only Green light & one to show only IR light.  Currently we only have one camera looking at the ITMs, we want to have (2) GigE Digital cameras with proper filters to look at the ITMs.  This is to aid in alignment with the Green & IR lasers.

I received filters (from MidOpt Systems) this afternoon and measured transmission of Green & IR light through each of the filters.  I had the laser point at an Ophir Power Meter, noted power, then placed filter in front of power meter and noted power.  Here are the results:

IR laser set to ~0.474W

Transmission through the filters = power with filter (w/o filter)

Green laser set to ~100.5 mW

Transmission through the filters = power with filter (w/o filter)

The links for the filters above give info on them and Transmission v. Wavelength charts.  The Filters are M62 (62mm thread).  They can be screwed on the output of our Butterfly electric zoom lens.  These lens would then be installed on our Digital GigE cameras (with a beam expander in between?). 

Next thing to be done would be to see if any of these filters will work.

A wiki showing information for cameras is on the H1 Camera Page.

 

Images attached to this report
H1 ISC
keita.kawabe@LIGO.ORG - posted 21:47, Tuesday 22 April 2014 (11521)
ISC for Y arm today

Fixed (not that they were "broken") the unsoldered connectors.

PDH CM board was modified so that it should be identical to X arm.

For some reason we found that the demod output for the PDH was railed at 10V (or was that -10V?). LO and PDH RF were both OK, but the I output as well as IMON were both railed. The demod chassis has two I/Q demod and the unused one was still alive, so we just switched. The broken one is still left there.

Though the only Hartman path optic on the table was a pickoff for that path, I installed another pickoff downstream of the first pickoff and directed the beam to REFLB diode so we have something to monitor.

We started locking the arm again. But the CM board output to VCO would rail really quickly. We might have to enable LSC path to offload the VCO.

When locked, the arm transmission is not maximized, we're probably talking about 10% or so smaller transmission than the true peak. Looking on the oscilloscope, it's clear that the PDH error signal is not symmetric around the 00 carrier transmission when locked. We swapped the RF source with IFR generator and changed the modulation frequency +-30kHz or so (transverse mode spacing is 28.59kHz for Y arm) with a few kHz step at a time. We were able to observe clear steps in the transmission when we changed the modulation frequency, but this was not a big effect, we were never able to fix the asymmetry of the PDH error around the lock point. In the end we changed the oscillator back to the original.

Since it seems like we have a relatively large 20 mode, one thing to try is to improve the mode matching and see what happens.

H1 ISC
sheila.dwyer@LIGO.ORG - posted 19:18, Tuesday 22 April 2014 (11519)
work on ISCT1

This morning Pablo and I worked on getting (separate) cameras on both of the arm transmitted beams on ISCT1. We approximately followed the layout posted in llo alog 12198

To do this we had to add a lens in the Y arm path before the pick off for a camera, we used a Laser Optic +50mm roc. We used R=10% beam splitters for the pick offs for the cameras. We used analog cameras temporarily.  I borrowed the POP cable (labeled POD) for the X arm trans camera, and used the REFL_PD camera that we have been using for the X+Y arms for the Y arm.  The Y arm spot is on a baffle, the camera has a lens and is focused on the spot on the baffle, this makes a nicer image where we can clearly see the different cavity modes.  We will do this for the X arm camera as well once we find a good lens. 

Once we saw that both arms had nice IR flashes, I worked on aligning the diff beatnote.  On the diff BBPD we have about 126 uW from the Y arm when it is locked and about 40uW from the X arm.  We get -30dBm on the beatnote, (at 160MHz) I din't really try to optimize this since the cavity keeps dropping out of lock making it difficult to adjust.

H1 SUS
arnaud.pele@LIGO.ORG - posted 19:02, Tuesday 22 April 2014 - last comment - 19:25, Tuesday 22 April 2014(11517)
EY oplev

[Sheila Arnaud]
EY oplev signal got somehow really noisy during the afternoon. It doesn't seem to be seimic noise. It is not clear why, but we should check this when possible.
Attached is a comparison spectra of EY oplev pitch at two different times this afternoon, with ISI isolated. Pink curve is the most recent one.

Images attached to this report
Comments related to this report
sheila.dwyer@LIGO.ORG - 19:25, Tuesday 22 April 2014 (11520)SEI

We started looking at this OpLev because we saw 1urad pp in pitch, which may have been one reason the arm cavity wasn't locking stably.  We tried a few configurations with different blends. 

With Tbetter everywhere except RZ, we see almost 1urad pit pp (over 16 seconds) and 0.4urad yaw. 

With Tcrappy on Stage 2 and Tbetter on stage except for RZ we see 0.25pp PIT, which is now dominated by motion around the suspension resonances instead of the low frqeuency motion we saw with Tbetter. 

Turning on and off sensor correction didn't seem to change the situation much, it is off right now.

H1 ISC
alexan.staley@LIGO.ORG - posted 17:42, Tuesday 22 April 2014 - last comment - 08:55, Wednesday 23 April 2014(11516)
EY measurements

(Keita, Alexa)

A more in depth alog will be posted later about what we did today at EY. For now I have attached the data for the OLTF we measured (mag --> 122.txt, phase --> 123.txt). The UGF was about 2.3kHz with a phase margin of a little less than 60 deg. The phase shifter was adjusted to 23ns. The PDH REFL servo board settings were as follows:

We also measured the peak to peak of the PDH error signal and found it to be ~816mVpp.

Non-image files attached to this report
Comments related to this report
alexan.staley@LIGO.ORG - 08:55, Wednesday 23 April 2014 (11525)

We remeasured the green power along ISCTEY (its possible we had the wrong laser setting on the powermeter when we measured this last):

  • Out of laser: 32mW
  • Before first Faraday: 29mW
  • Out of first Faraday: 26.5mW
  • After EOM: 25.5mW
  • After second Faraday: 21.5mW
  • Before pick off: 21.4mW
  • After pick off: 18mW
H1 ISC (ISC)
stefan.ballmer@LIGO.ORG - posted 17:27, Tuesday 22 April 2014 (11515)
Control State Definition
Some updates to the Control State Definition code:

- Updated the compilation to also read in the autoBurt.req file. If not listed in the xml file, all channels in the autoBurt.req file (except read-only and alarm-relates channels) will now be enforced to zero.
- Updated the medm generator. It's now python code, and parses the xml directly. This way external states also show up on the screen.
- Added links to the documentation on the medm screen.
H1 SUS
filiberto.clara@LIGO.ORG - posted 16:54, Tuesday 22 April 2014 - last comment - 19:03, Tuesday 22 April 2014(11514)
ETM UIM Coil Drivers
Modified the output stages of the ETM UIM coil drivers, to give a factor of 4 more range per ECR E1400164.

All four channels of each unit were modified as followed:
R10 & R15 were changed to 2.2K Ohm
R5  & R23 were changed to 2.0K Ohm 

Unit from EX - S0900303
Unit from EY - S0900304
Comments related to this report
arnaud.pele@LIGO.ORG - 19:03, Tuesday 22 April 2014 (11518)

The theoretical transconductance (@ DC) for each channel in the "High Dynamic Range Mode" is 0.625mA/V = -64dB Amps/Volt (from p2 of T140023 assuming a maximum 10V input).

H1 SEI (INS)
jim.warner@LIGO.ORG - posted 16:30, Tuesday 22 April 2014 (11513)
HAM5 ISI TF's running on OPSWS0

No touching.

LHO General
thomas.vo@LIGO.ORG - posted 16:29, Tuesday 22 April 2014 (11512)
2014-04-22 Ops Summary
- PSL went down today and Sheila brought it back up, diffracted power is a bit low in the ISS.

- Sheila to ISCT1 to work on cameras 9:00 AM PT

- Fil to EX and EY 9:10 AM PT

- Richard and Peter to EY to work on ESD 9:15 AM PT

- TCS Aussie Crew: Aidan, Matt, David working on CO2X and CO2Y tables, turning on laser.

- Mark(Apollo) going to EX and EY to look for tools 11:15 AM PT

- Gerardo and Mark Barton to H2 PSL Enclosure

- Corey to HAM6 bay to turn on laser for camera work

- Ken running conduit from CO2X table to H1 chiller pods

- Apollo breaking bolts at HAM5&6, Jeff Bartlett taking dust counts, temporarily disabling dust monitor 15

- Hugo updating MEDM screens remotely from Stanford

- Jonathan working on OS upgrade on SVN and Bugzilla

- Filaberto working on output stages of the ETM UIM coil drivers.

- Guardian machine reboot, IMC remained locked in that time during entire reboot and came back in a locked state!

- Cleared HEPI L4C stat monitors.
H2 SEI
mitchell.robinson@LIGO.ORG - posted 16:18, Tuesday 22 April 2014 (11511)
Staging building, 3IFO
Scott, and I finished what we could of the actuator sub assemblies. There are a few parts that are currently MIA that will effect the last unit. 

After lunch Jim and Hugh came to the rescue and aided with the installation of unit 2's horizontal GS-13's. 
H1 SEI (SEI)
hugo.paris@LIGO.ORG - posted 16:17, Tuesday 22 April 2014 (11510)
HEPI MEDM screens Updated

The HEPI overview screens were not displaying the ISI DAC outputs correctly. This was fixed on the HEPI overview screen template, and the update was ported here at LHO.

The update required to add the ISI_DAC macro substitution to the macro substitution text files of HEPI, which was done too. The new version of those files was committed to the svn -r7772

Details about the content of the update can be found in SEI aLOG #453

Work was performed under WP 4588, which can now be closed. 