Displaying reports 72901-72920 of 84069.Go to page Start 3642 3643 3644 3645 3646 3647 3648 3649 3650 End
Reports until 15:14, Tuesday 22 April 2014
H1 CDS (SYS)
david.barker@LIGO.ORG - posted 15:14, Tuesday 22 April 2014 (11507)
Removed CDS and PSL alarms from operator alarm station

We are redefining what the EPICS audible alarm system, reducing it to only include alarms which are not accessible via other data channels and which need URGENT operator/staff attention. To this end I have removed the CDS and PSL alarms from the operator alarm station. This leaves the VACUUM, FMCS, DUST and SOFTWARE_WATCHDOG alarms in place. I had re-worked the Software Watchdog alarms last week to remove duplicate and spurious reporting of these alarms.

Coupled with this is the requirement that urgent alarms also send text messages to cell phones to cover times when the operator is not on duty.

Daniel would like non-urgent alarms to be reported by a new system which filters the data before presenting it to the operator. Currently alarm status is available on MEDM screens which the operator checks regularly.

H1 AOS
sheila.dwyer@LIGO.ORG - posted 14:29, Tuesday 22 April 2014 (11506)
ETMX ISI tripped

We had ETMX running Tcrappy and sensor correction.  We don't know why it tripped.

Now I will put it back to Tbetter with sensor correction because the microseism has come back down.

Images attached to this report
H1 ISC
alexan.staley@LIGO.ORG - posted 12:58, Tuesday 22 April 2014 - last comment - 15:35, Tuesday 22 April 2014(11505)
Fiber Polarization

I noticed that the fiber polarization (in wrong pol) at EY had drifted back up to 32%. The normal procedure for this is to turn the controller back on and adjust the settings; this never seemed to disturb anything. When I turned the controller on it made a funny noise (it sounded like the waveplates were moving rapidly), and BOTH EX and EY polarizations got drastically worse. I manually adjusted both polarizations, and they are back down now. I turned the box off. I did not want to turn the box back on. Clearly this is not good...

sad

Comments related to this report
cyrus.reed@LIGO.ORG - 15:35, Tuesday 22 April 2014 (11509)

The temperature in the MSR were the polarizer is located is varying a lot more now with the change in weather (and between day/night).  As I recall, it's pretty sensitive to temperature changes...  and the MSR isn't really temperature controlled to a high degree of accuracy beyond 'not hot'.

H1 ISC (ISC)
stefan.ballmer@LIGO.ORG - posted 12:23, Tuesday 22 April 2014 (11504)
Another y-arm initial alignment
Did another initial y-arm alignment from scratch.

- TMS pointing to hit the center of ITMY, with the hitting-catch-at-all-four-cardinal-directions technique (Pitch -107.0, Yaw: -25)
- ITMY pointo to the Baffle PD's:
   BPD 1:  Pitch: 197.0, Yaw -157.5
   BPD 4:  Pitch: 230.7, Yaw -191.5
   Center: Pitch: 213.85,Yaw -174.5
- EMTY pointing to center, with the hitting-catch-at-all-four-cardinal-directions technique (Pitch -107.7, Yaw: -34.1)

- This brought back good flashes at the center of the reference camera, without any move of the BS or PR3.
H1 ISC
alexan.staley@LIGO.ORG - posted 12:16, Tuesday 22 April 2014 (11503)
EY REFL Servo Board Mod SN S1102632

As mentioned in alog 11488, I had pulled the ALS EY REFL common mode board. I have modified the second boost stage so that it is the same as the first (pole at 100 Hz and a zero at 1 kHz). The serial number is SN S1102632. In detial:

The board is now back in the rack and the TFs look good.

H1 ISC
keita.kawabe@LIGO.ORG - posted 12:14, Tuesday 22 April 2014 - last comment - 08:25, Wednesday 18 November 2015(11498)
Solder things.

This is a tabletop photodetector interface (D1002932-V5, S1103811) in ISCTEY that was misbehaving yesterday. I opened it and found this.

None of the power connectors for Thorlabs PDs and BBPDs were soldered to the board. And one of the connectors was loose (right-most one in the video). See how the legs move as I wiggle.

It's a miracle that it worked at some point. I soldered all of the connectors.

(If avi doesn't play, try mov file, though the time of the mov file seems to be out of whack.)

Non-image files attached to this report
Comments related to this report
vernon.sandberg@LIGO.ORG - 15:55, Wednesday 23 April 2014 (11540)

I opend and checked two randomly selected "Table-Top" boxes (D1002932-v4) from the twelve boxes in Mid-Y storage, serial numbers S1103796 and S1103810, for quality of build and found them to be in good shape.  The front circuit card was soldered onto the panel connectors.  All screws and fasteners were tight.  The general quality of work looked good.  Let's hope the box Keita found (S1103811) was an oversight.

H1 CDS
cyrus.reed@LIGO.ORG - posted 11:41, Tuesday 22 April 2014 (11502)
h1guardian0 Rebooted

I've rebooted h1guardian0 as a requested test to see if it recovers gracefully after a restart, which it appears to do.  Also, I took the opportunity to configure the IPMI management port during the reboot.  Note that when I logged in to reboot the machine, there were 20 zombie processes reported.  That's probably not great since it was just rebooted yesterday.

H1 General
jeffrey.bartlett@LIGO.ORG - posted 10:18, Tuesday 22 April 2014 (11497)
Dust Counts at HAM5
   The Apollo crew was breaking loose the bolts at the septum between HAM 5 and HAM6 to prepare for the upcoming HAM5 installation work. Monitored the dust counts before and during the work on the bolts. Before work started the dust counts in the cleanroom were zero. During the loosing process counts were in the 40 to 60 range while the bolts were actually being turned. Shortly after the wrench work stopped the counts dropped back to zero. I saw no counts over 100 0.3 micron particles during the monitoring; larger particle counts were generally less than the 0.3 micron counts.   
H1 CDS
cyrus.reed@LIGO.ORG - posted 09:06, Tuesday 22 April 2014 - last comment - 11:00, Wednesday 23 April 2014(11496)
DAQ Driver Updates

I am about to start upgrading drivers on the DAQ as specified in WP4583.  There will be NO DATA recorded during the period when the data concentrator is rebooted - as it is due for a full FSCK at boot, this will be a period of 10-15 minutes.  For the remaining system upgrades, there will be intermittent access to the recorded data as those systems (h1nds1, h1fw1, h1broadcast0) are rebooted.  Changes to h1nds0 and h1fw0 will happen at a later time.  Further updates will be posted to this entry with specific downtime.

Comments related to this report
cyrus.reed@LIGO.ORG - 10:25, Tuesday 22 April 2014 (11499)

DAQ Downtime Report

h1dc0: 16:07:40 - 16:18:00 UTC  There is NO data recorded by the DAQ during this period.

h1nds1: 16:26:00 - 16:28:20 UTC

h1fw1: 16:33:55 - 16:55:50 UTC  There is NO data available via h1nds1/h1fw1 for this period.  Use h1nds0/h1fw0 for frames ending/starting in this timeframe.

h1broadcast0: 17:06:55 - 17:16:00 UTC

cyrus.reed@LIGO.ORG - 10:39, Tuesday 22 April 2014 (11501)

Most installs were uneventful.  However, on h1fw1, the MTU was not set to 9000 in /etc/conf.d/net as it is on h1fw0, which prevented daqd from running after restart.  I changed /etc/conf.d/net to match and rebooted to fix; I have no idea how it ever worked before.  On h1broadcast0, I disabled the items in local.start that are only useful for a data concentrator; h1broadcast0 being a clone of a data concentrator had these unnecessary additions.

cyrus.reed@LIGO.ORG - 11:00, Wednesday 23 April 2014 (11531)

Technical Details

(l inadvertently left these out of the original entry)

The change is to upgrade the Myricom ethernet adapter drivers for the DAQ broadcast network to version 1.5.3.p3, compiling them with the MYRI10GE_ALLOC_ORDER=2 option and using the big_rxring firmware at driver load.  This is to attempt to reduce the number of dropped frames that are seen occasionally, most often on the framewriters, that also trigger 'retransmission request' errors in the daqd log.  And additionally, on the data concentrator to make use of the MYRI10GE_THROTTLE option to see if tuning the packet emission rate has any effect for the receiving systems.  The primary method of measuring any change is to use the SNMP monitoring of the DAQ broadcast switch to monitor the dropped/paused frames per host port.  The same changes on the test stand indicate some improvement.

H1 PSL
justin.bergman@LIGO.ORG - posted 09:06, Tuesday 22 April 2014 - last comment - 10:27, Tuesday 22 April 2014(11495)
PSL Check

Things were working fine till 9:00 AM PT, then the PSL shut off due to a chiller error.  Sheila was notified of this.  When the PSL comes back online, I'll append its status with a comment.

This is Thomas

Comments related to this report
thomas.vo@LIGO.ORG - 10:27, Tuesday 22 April 2014 (11500)PSL
Sheila turned the laser back on, she thinks the chiller may have caused the trip, but it didn't need re-filling.

- Laser is ON
- Output power = 27.5 W
- Watchdog is RED
- PSL SYSSTAT.adl is all green

- PMC just came back online
- PMC Reflected power at 1.4 W and Transmission at 10.0 W

- Ref Cav just came online
- Camera looks ok and trans PD threshold is at .75

- ISS is at 6.58% diffracted power
- Just came back online.
H1 TCS (TCS)
aidan.brooks@LIGO.ORG - posted 08:43, Tuesday 22 April 2014 (11494)
CO2X install work - AOM aligned

Aidan. Matt. Dave H.

The CO2X laser was energized and aligned to the initial polarizer and AOM. The AOM was energized (the external RF input and power appear to work successfully) and set to maximum modulation depth. The AOM was aligned to the Bragg angle to maximize the diffraction efficiency (this has yet to be measured).

The cable connecting the voltage and current monitor channels from the laser power supply to the ADC had to be rewired as the I_MON and  GND pins were back to front.

H1 CDS (DAQ)
david.barker@LIGO.ORG - posted 08:22, Tuesday 22 April 2014 (11493)
CDS model and DAQ restart report, Monday 21st April 2014

model restarts logged for Mon 21/Apr/2014
2014_04_21 09:46 h1iopsush2a
2014_04_21 09:48 h1susmc1
2014_04_21 09:48 h1susmc3
2014_04_21 09:49 h1susmc3
2014_04_21 09:51 h1suspr3
2014_04_21 09:51 h1susprm
2014_04_21 09:52 h1suspr3

Reboot of h1sush2a Link. Unsure why some models got logged twice. (Purple=IOP, Green=User)

H1 SEI
sebastien.biscans@LIGO.ORG - posted 07:51, Tuesday 22 April 2014 (11492)
ISI Watchdogs trips summary (04/14 - 04/21)

Find attached the watchdogs trips summary of last week/beginning of this week. We'll discuss about it during the SEI portion of the testing meeting today.

Non-image files attached to this report
H1 ISC
sheila.dwyer@LIGO.ORG - posted 20:00, Monday 21 April 2014 - last comment - 20:10, Monday 21 April 2014(11490)
Y arm IR alingment, green separation on ISCT1

Stefan, Sheila

After locking the Xarm (we turned on the opLev damping, and slowed down the gain ramping in the guardian for the ALS COMM ). We aligned the IR to the X arm using IM4 and PR2.  Then we tweaked to BS alignment, and saw flashes of up to 350 counts on ASC_Y_TR_A_SUM.

We went out to the Y end to try to aling the beam onto the camera and LSC PD, but we didn't see the beam while the cavity was flashing and we notied that we still need power to the analog camera on the table. 

We came back to the corner and looked at the separation of the green beams on ISCT1; right before the prism they are separated by 9 mm. They were well placed on the prism as we found them. 

We currently have both the X and Y transmitted beams on the ISCT1 camera, and have marked both of their current positions on the monitor in the control room.  Tomorow we can use this as a reference for the BS alignment. 

Comments related to this report
stefan.ballmer@LIGO.ORG - 20:10, Monday 21 April 2014 (11491)
BS alignment: 187.4 pitch, -264.0 yaw

Picture 1: alignment snapshot: PR2 and IM4 were tweaked.
Picture 2: picture of beam separation at prism: 9mm
Picture 3: Beam alignment on monitor
Images attached to this comment
H1 ISC
alexan.staley@LIGO.ORG - posted 18:51, Monday 21 April 2014 (11488)
Y arm updates

(Keita, Alexa)

We adjusted the phase shifter delay line to 20ns. We optimized this by looking at the X-Y plot of the demod IMON error signal and the PD DC readout (see first picture).

With this phase, and the following common mode board settings, we took an open loop transfer function of the PDH:

The OLTF gave a UGF of about 5.6kHz with a phase margin of about 20 deg. I have attached a picture and the data (119 --> mag, 120 --> phase). However, this was not exactly reproducible as the lock kept dropping and the alignment was drifting.

We pulled the PDH common mode board SN S1102632 to make adjustments to the second boost stage as made for EX (see alog 9357). We also pulled the generic interface for the ISC tables (D1002932) SN S1103811 since two out of the four ±12V DC output were not working. Both these units are currently in the EE shop.

 

We also found a bad connection between the phase modulation panel on ISCTEY and the pockel cell. We reconnected the cable and this seemed to help. We measured the EOM RF power, and found 240mV RMS.

Images attached to this report
Non-image files attached to this report
H1 SUS (SEI)
arnaud.pele@LIGO.ORG - posted 18:30, Monday 21 April 2014 - last comment - 19:49, Monday 21 April 2014(11487)
ETMY ITMY oplev spectra

Attached is a spectra of ITMY and ETMY optical lever with ISI blends in two different configurations : 

BLUE : Tbetter on both stages and for every DOF (except for Ry which stayed on Tcrappy)
PINK : Tcrappy on both stages

The sensor correction on stage 1 was running during the measurement for both ISIs.

There is no major difference in the YAW spectra (bottom two plots) since Ry stays in Tcrappy, but the difference can be clearly seen in Pitch (top two plots). Tcrappy improves the microseism (~.1Hz) but gives less attenuation at the sus resonance frequencies (~.5Hz).

Images attached to this report
Comments related to this report
sheila.dwyer@LIGO.ORG - 19:49, Monday 21 April 2014 (11489)

The reason we started looking at this is that we were bothered by the large (order of 1 urad peak) fluctuations at around 0.14Hz.  The microseism is a bit higher today that it was when Rich was here designing Tbetter, it has been around 5e-5 decaum/s most of the day, (the upper dashed line on the 0.1-0.3 Hz PEM FOM) We are also running Tcrappy +sensor correction on the xarm, with OpLev damping as well. 

Displaying reports 72901-72920 of 84069.Go to page Start 3642 3643 3644 3645 3646 3647 3648 3649 3650 End