Displaying reports 72941-72960 of 84064.Go to page Start 3644 3645 3646 3647 3648 3649 3650 3651 3652 End
Reports until 11:50, Sunday 20 April 2014
H1 SUS (SEI, SYS)
jeffrey.kissel@LIGO.ORG - posted 11:50, Sunday 20 April 2014 (11463)
Beginning remaining changes on H1 SUS WD Systems
HAM systems remain: 
SEI: HPI HAM2, HPI HAM3
SUS: IMs 1-4, MC1, MC2, MC3, PRM, PR2, PR3, SR3, SR2, SRM, OMC

Starting with HEPI reboots, which will take down the mode cleaner.

Getting started roughly around 
1082055016
Apr 20 2014 18:50:00 UTC
Apr 20 2014 11:50:00 PDT
H1 AOS (DAQ)
david.barker@LIGO.ORG - posted 09:55, Sunday 20 April 2014 - last comment - 10:01, Sunday 20 April 2014(11461)
CDS model and DAQ restart report, Saturday 19th April 2014

model restarts logged for Sat 19/Apr/2014
2014_04_19 13:26 h1hpietmx
2014_04_19 13:27 h1hpietmx
2014_04_19 13:30 h1susetmx
2014_04_19 15:01 h1susetmy
2014_04_19 15:03 h1hpietmy
2014_04_19 15:18 h1susitmy
2014_04_19 15:19 h1hpiitmy
2014_04_19 15:29 h1susitmx
2014_04_19 15:32 h1hpiitmx
2014_04_19 15:45 h1sustmsx
2014_04_19 16:10 h1sustmsy
2014_04_19 17:14 h1hpibs
2014_04_19 17:19 h1susbs

2014_04_19 18:35 h1broadcast0
2014_04_19 18:35 h1dc0
2014_04_19 18:35 h1fw0
2014_04_19 18:35 h1fw1
2014_04_19 18:35 h1nds0
2014_04_19 18:35 h1nds1

A busy commissioning day followed by a DAQ restart. No unexpected restarts.

Comments related to this report
david.barker@LIGO.ORG - 10:01, Sunday 20 April 2014 (11462)DAQ, SEI

I just cleared the warnings raised by yesterday's restarts and all cleared except a DAQ error on HEPI BS and ETMY. Looks like their INI files are out of sync between FE and DAQ (model restart post-DAQ-restart). We might want to restart the DAQ ASAP as data from these systems is most probably corrupt.

H1 SUS (CDS, DetChar, SEI, SYS)
jeffrey.kissel@LIGO.ORG - posted 19:51, Saturday 19 April 2014 (11460)
All BSC SUS Watchdogs Updated as per ECR E1400102
J. Kissel

Beginning to tackle the changes approved in ECR E1400102, i.e. modifying of SUS User Watchdog to reduce false alarm rate, I've made it through the three BSC-type suspensions (and their respective HEPIs), QUADs, BSFMs, and TMTSs. The final change list includes:
- Removing the OSEM DC and Actuator AC trigger paths from the watchdogs
- Removing the Optical Lever watchdog trigger paths from the QUAD and BSFMs
- Merging all stages of USER and USER DACKILL MEDM screens
- Creating a one-click, reset all button for all stages of USER and USER DACKILL watchdogs (by hooking a single reset signal to each stage of USER WDs, and copying SEI's script for resetting the USER and USER DACKILL psuedo-simultaneously.)
- Changing the SUS USER DACKILL (which informs the "PAYLOAD" trigger flag of the ISIs) to use the AND of every watchdog stage instead of an OR of just the top mass [behavior is unchanged for TMTS, but TMTS is NOT hooked up to the ISI]
- Removing the SUS USER DACKILL connection to HEPI's PAYLOAD trigger

I've exercised the SEI / SUS watchdogs (by decreasing the trigger threshold below normal values) to ensure the desired behavior is achieved and all screens are reporting the correct status, and no funky reset loops happen. Of note, if just one of the USER WDs are green, then one can reset the USER DACKILL i.e. the PAYLOAD flag for the ISI. This is fine -- those user watchdogs which are still setting off triggers cannot be reset, as has always been the case. This just makes it that much easier to begin resetting a chamber after a "catastrophic" chamber trip, which almost always is because of a front-end boot fest, not anything physically happening to the chamber.

FIXME's as a result of these changes (for BSFMs and QUADs ONLY):
- Because the L3 (fr WUADs) and M3 (for BSFMs) no longer exist, the Guardian is getting confused in its checks for whether the suspension is tripped, and throwing an error. I tried digging into the sustools.py rabbit hole, but got lost and gave up quickly. I'll leave this to Jamie / Mark / Arnaud to fix. Regardless of the guardian failure, all SUS have been turned on, damped, with their previous alignment restored.
- Because the L3 (fr WUADs) and M3 (for BSFMs) no longer exist, I've terminated where the corresponding bit is fed into the ODC bitword creator instead of shifting everything around (again). As such, bits 7 (for QUADs) and 5 (for the BSFM) should be masked out and ignored until we're motivated enough to clean this up in the front end.

Though I've tried to restore all BSC chambers to full isolation, damping and alignment, the ground has been too violently non-stationary (wind, earthquakes, trucks, etc.) to keep things up for too long. I'll try again before I leave, but I doubt it'll stay up for too long.

After all changes were complete, h1dc0 was successfully rebooted at 01:35 UTC (18:35 PDT), with both frame writers (h1fw0 and h1fw1) happily cliking up there up-time (~1500 seconds as of this log)

Those files affected / created and now committed to the USERAPPS repository:

${userapps}/release/sus/common/src/
M       WATCHDOG.c
${userapps}/release/sus/common/models/
M       TMTS_MASTER.mdl
M       QUAD_MASTER.mdl
M       SIXOSEM_F_STAGE_MASTER.mdl
M       FOUROSEM_STAGE_MASTER_OPLEV.mdl
M       BSFM_MASTER.mdl
${userapps}/release/sus/common/scripts/
A       wdreset_all.pl
${userapps}/release/sus/common/medm/
M       bsfm/SUS_CUST_BSFM_OVERVIEW.adl
A       bsfm/SUS_CUST_BSFM_WD.adl
A       quad/SUS_CUST_QUAD_WD.adl
M       quad/SUS_CUST_QUAD_OVERVIEW.adl
M       quad/SUS_CUST_QUAD_R0.adl
A       tmts/SUS_CUST_TMTS_WD.adl
M       tmts/SUS_CUST_TMTS_OVERVIEW.adl
${userapps}/release/hpi/h1/models/
M       h1hpietmx.mdl
M       h1hpietmy.mdl
M       h1hpiitmx.mdl
M       h1hpiitmy.mdl
M       h1hpibs.mdl

Images attached to this report
H1 SEI (CDS)
jeffrey.kissel@LIGO.ORG - posted 18:11, Saturday 19 April 2014 (11459)
ETMY GND STS Not Cabled Up Correctly into ISI ADCs
J. Kissel, R. Schofield,

Robert was making ground motion comparisons between PEM channels and SEI channels, and discovered that the H1:ISI-GND_STS_ETMY_[X,Y,Z]_DQ were reading ADC bit noise. Confused, having heard that the STS-2 had been re-installed about two-ish weeks ago, I took a look around and found the usual confusion between A, B, and C, channels in HEPI vs. ISI. The agreed upon, end-station, cabling configuration is to plug in the STS-2 to the B channel for both HEPI and ISIs, such that it gets routed in at the top level of the front-end model, in through the isi2stagemaster library part, then up out again to be stored in the frames once and only once. However, this means that the STS distribution chassis must have its output plugged into BOTH HEPI and ISI's "B" ADC channels. Currently, the STS is happily plugged into HEPI's B channels, but ISI's version is plugged into the A channels. It also doesn't have its calibration filters turned on. 

Queue sad trombone. *wahn*wahn*. 

We'll fix it on Tuesday (or earlier if the analog CDS crew has time).
H1 SEI
jeffrey.kissel@LIGO.ORG - posted 13:21, Saturday 19 April 2014 (11458)
H1 ISI ETMX Tripped
1081907495
Apr 18 2014 18:51:19 PDT
Apr 19 2014 01:51:19 UTC
Stage 1 and Stage 2 actuators.

Found the trip after 12 hours had passed, so couldn't check the seismic FOMs, but judging by the amplitude and frequency of the actuation control before the trip, and the large amounts of earthquakes recently, that would be my guess. There's a couple of small ~ 3 [mag] EQs arounf that time, capped with a 4.7 [mag] in Northern Alaska at 01:49 UTC. Disappointingly, USGS no longer has those "time of arrival" contour maps (or I couldn't find it with a bunch of clicking around the site), so you can't use that to narrow down which earthquake was yours. 
Images attached to this report
H1 FMP
jeffrey.kissel@LIGO.ORG - posted 11:04, Saturday 19 April 2014 (11457)
Fire Dept. Checking out Alarm at Mid-Y
Fire department called at 10:58a PDT, asking to check out a box at the South Mid-Station, so I said "sure, no problem." After speaking with Robert, he suggests that when they get a glitch in their alarm system, they have to send someone out to confirm its not a fire, which we suspect is the case -- no fire (confirmed by corner station camera), glitch in the system, routine check. Will post if we hear anything further/otherwise.
H1 CDS (DAQ)
david.barker@LIGO.ORG - posted 07:51, Saturday 19 April 2014 (11456)
CDS model and DAQ restart report, Friday 18th April 2014

model restarts logged for Fri 18/Apr/2014
2014_04_18 10:21 h1susetmx
2014_04_18 10:43 h1susitmx
2014_04_18 10:43 h1susitmy

2014_04_18 10:49 h1broadcast0
2014_04_18 10:49 h1dc0
2014_04_18 10:49 h1fw0
2014_04_18 10:49 h1fw1
2014_04_18 10:49 h1nds0
2014_04_18 10:49 h1nds1

2014_04_18 13:25 h1susetmy
2014_04_18 14:21 h1suspr3
2014_04_18 14:21 h1sussr3
2014_04_18 14:37 h1susbs

2014_04_18 14:44 h1dc0
2014_04_18 14:44 h1nds0
2014_04_18 14:46 h1broadcast0
2014_04_18 14:46 h1fw0
2014_04_18 14:46 h1fw1
2014_04_18 14:46 h1nds1

no unexpected restarts.

H1 ISC
sheila.dwyer@LIGO.ORG - posted 07:29, Saturday 19 April 2014 (11446)
Fiber Polarization Controller

(Sheila, Alexa)

When I was at EY taking the noise measurements, I noticed that the fiber polarization (in the wrong pol) was up to about 60%. I asked Sheila to readjust the controller box for me. Now it's back down to 18%, and the controller is off. We should keep an eye on this drift...

(Alexa posting as Sheila)

A photo of the new settings is attached
Images attached to this report
H1 SUS (CDS, DetChar, ISC, SYS)
jeffrey.kissel@LIGO.ORG - posted 17:40, Friday 18 April 2014 (11454)
Optical Lever Damping Changes Complete as per ECR E1400207
J. Kissel

In order to get started on the suspension software ECRs with top priority, I needed to first clean up the library parts and MEDM screen from the prototype optical lever damping. I've completed the needed changes as described in ECR E1400207. All changes have been installed in the front-end code, the affected models have been restarted and restored, MEDM screens have been modified, and all committed to the userapps repo. Details of the changes are spelled out below. I have *not* captured any new safe.snaps, as folks have begun to lock the Y-ARM. 

Over the weekend I'll begin making the high-priority changes, starting with removing redundant watchdog components to reduce the false alarm rate as per E1400102. 

Stuart -- you should wait to begin re-merging the LLO models with the library parts until I've completed the majority of the changes.

Details
-------------------
I've done the following to the following SUS types:
QUAD:
- Cleaned up ${userapps}/release/sus/common/models/FOUROSEM_STAGE_MASTER_OPLEV.mdl, piping the ODC state bit for the optical levers to the output.  These bits have been inserted in the middle, after the M0 and R0 damp bits, into bit 11 and 12. This means the L1, L2, and L3 LOCK state bits are now 13-15. Notably, the optical lever damping loop drive path goes *through* the DRIVEALIGN matrix, to gather any P2Y, Y2P, or Angle to Longitudinal decoupling that we install -- this is different from how the BSFM optical lever damping was originally installed.
- Added outputs to L1 and L2 optical lever state bits to ODC vector in ${userapps}/release/sus/common/models/QUAD_MASTER.mdl
- Cleaned up ${userapps}/release/sus/common/medm/quad/SUS_CUST_QUAD_OVERVIEW.adl, and added the 2 extra ODC bits in the bitword light representation in the top right corner.
- Added two extra bits to ${userapps}/release/sus/common/medm/quad/SUS_CUST_QUAD_ODC.adl.
I *have not* updated the bit representation channels, I'll that to the ODC team.

HLTS:
- Modified ${userapps}/release/sus/common/models/HLTS_MASTER.mdl to use FOUROSEM_STAGE_MASTER_OPLEV.mdl on the M2 stage, modified the M3 stage to match the optical lever damping topology of the FOUROSEM_STAGE_MASTER_OPLEV.mdl (as usual, the bottom stage of every suspension type is different in some way, so it must remain unique). Both stages now output an optical lever damping bit to the ODC. As with the QUAD, the optical lever damping status bits have been inserted just after the M1 OSEM damping status bits. As such, bits 6 - 8 are M1, M2, and M2 damping, with 9, 10, and 11 being the M1, M2, and M3 LOCK status bits.
- Modified ${userapps}/release/sus/common/medm/hxts/SUS_CUST_HLTS_OVERVIEW.adl to include optical lever damping on M2 and M3, and added two bits to the ODC word lights in the top right.
- Created new screens ${userapps}/release/sus/common/medm/hxts/SUS_CUST_HLTS_[M2/M3]_OLDAMP_ALL.adl which contain the details of the two OLDAMP filter banks, virtually identical to the BSFM and QUAD versions.
- Modified ${userapps}/release/sus/common/medm/hlts/SUS_CUST_HLTS_ODC.adl to include two extra damping bits. As with the QUAD, I *have not* updated the bit representation channels, I'll that to the ODC team.

BSFM:
- Modified ${userapps}/release/sus/common/models/BSFM_MASTER.mdl to route the OLDAMP servo through the DRIVEALIGN matrix. Regrettably, because we will eventually need to install M1 to M2 stage OSEM damping to kill the highest Roll and Vertical modes of the suspension, we cannot just copy in and use FOUROSEM_STAGE_MASTER_OPLEV.mdl. Again, also worth note -- the OLDAMP path is now routed through the DRIVEALIGN matrix. There's currently no filters in the P or Y elements of the matrix, so the loop shape / design is unaffected. (The status bit had already been routed out from the M2 stage up in to the ODC vector).
- Made a few aesthetic changes to ${userapps}/release/sus/common/medm/bsfm/SUS_CUST_BSFM_OVERVIEW.adl such that the OLDAMP path matched the QUAD and HLTS.
- Modified ${userapps}/release/sus/common/medm/bsfm/SUS_CUST_BSFM_ODC.adl to include extra damping bits. As with the QUAD, I *have not* updated the bit representation channels, I'll that to the ODC team.
H1 SEI
hugh.radkins@LIGO.ORG - posted 17:34, Friday 18 April 2014 (11455)
HEPI TFs Running on WHAM5--opsws0

nm

H1 SEI (INS)
hugh.radkins@LIGO.ORG - posted 16:26, Friday 18 April 2014 - last comment - 16:28, Friday 18 April 2014(11451)
WHAM5 SEI ISI Tuned Mass Dampers Installed

Once IAS finished, Greg & I installed the ISI Blade Spring's TMDs.  SNs 22 23 24 on Springs 1 2 3 respectively.

Comments related to this report
hugh.radkins@LIGO.ORG - 16:28, Friday 18 April 2014 (11452)

Photo of the little fella.

Images attached to this comment
LHO General
gerardo.moreno@LIGO.ORG - posted 16:25, Friday 18 April 2014 (11450)
Ops Summary (second part)

We had a couple of earthquakes today, a 7.2 near Tecpan de Galeana, Mexico, a 5.6 near Noatak, Alaska, and a 5.5 at Balleny Islands region.

- 9:06 am, Andres to the CS VEA, retrieve items.--> done by 10:17 am.
- 10:01 am, Hugh to CS VEA, HAM5 area for HEPI work.
- 10:01 am, Kyle to Y-End station, open GV18--> done by 10:20 am.
- 10:25 am, Jeff K. from the CR, new code per WP#4573.
- 10:30 am, Kyle to CS VEA, open GV7 and GV5.
- 10:40 am, Corey to CS cleaning area, retrieve garb.
- 10:45 am, DAQ restart for new code.
- 1:00 pm, Karen to Y-End, cleaning.
- 1:05 pm, David to CS VEA, TCS work.
- 1:30 pm, Hugh to CS VEA, continue with HAM5 work.
- 1:55 pm, Matt H. to CS VEA, TCS work.
- 2:04 pm, Cyrus to X-End, comtrol check/work. -->done by 2:33 pm.
- 2:09 pm, Jeff K. more code.
- 2:20 pm, DAQ restart.
 

LHO VE
kyle.ryan@LIGO.ORG - posted 16:09, Friday 18 April 2014 (11449)
Leaving PT246B energized and unpumped over the weekend
I ran into a "snag" with the RGA reconfiguration that I had envisioned and won't be able to pump the volume seen by PT246B until next week -> The pumping effect provided by the gauge isn't enough to match the out gassing and the pressure is rising as well as the rate of rise -> If it starts to "run away" I'll have to shut it off but, ideally, it will stay in its safe operating pressure range until I can pump it early next week.
LHO VE
kyle.ryan@LIGO.ORG - posted 15:50, Friday 18 April 2014 (11448)
Gate valve operations
Soft-cycled GV7 so that others could install viewport protector shutters etc -> Dumped unpumped gate annulus volume into pumped annulus volume, opened GV5 -> Dumped GV18's unpumped gate annulus volume into pump cart and decoupled pump cart from annulus plumbing -> Isolated and shut down Turbo and scroll pumps -> opened GV18
H1 SEI (INS)
hugh.radkins@LIGO.ORG - posted 15:14, Friday 18 April 2014 - last comment - 15:38, Friday 18 April 2014(11445)
WHAM5 SEI HEPI IPS channels now on and calibrated. Alignment zero'd.

The input matrices for WHAM5 are populated and calibration filters are loaded.  With the Actuators attached, the IPS and even better, the Cartesian Position Biases are valid.  The IPSs were zeroed immediately after the IAS look this morning.  So, the 'aligned' position is zero on this chamber.  Likely once I do range of motion etc tests, the system will de stress and certainly local numbers will change.  Usually though the cartesian values tend to cancel, we'll see.

Comments related to this report
hugh.radkins@LIGO.ORG - 15:38, Friday 18 April 2014 (11447)

Safe.snap made just now.

H1 SEI
hugo.paris@LIGO.ORG - posted 11:06, Friday 18 April 2014 - last comment - 15:13, Friday 18 April 2014(11434)
BSC-ISI Blend Filters Cleaned Up

JimW, HugoP,

With the recent blend design activities, a lot of filter files (.mat) were created, some were duplicated multiple times in the folder tree, while only a few were actually used. Some filters were also installed in the wrong slot, with the wrong name. For example: Start filters were installed in ITMX's TCrappy, TBetter was installed in ETMX's TCrappy. This can be quite mis-leading for the commissioners and we should avoid it.

We figured out which filter files should be used. We took those and gave them clear names in the common BSC part of the seismice SVN as follow, and removed every duplicate we found in the folder tree:

/ligo/svncommon/SeiSVN/seimic/BSC-ISI/Common/Complementary_Filters_BSC_ISI/aLIGO/

 

The Step_6 unit-specific scripts were modified for each BSC-ISI chamber to prevent accidentaly loading the wrong filter into the wrong slot again.

Every BSC-ISI blend filter was reloaded this morning at 9:35AM, from the agreed generic blends mentioned above.

Work will be commited to this SVN today, to facilitate next week's commissioner hand-off.

Comments related to this report
hugo.paris@LIGO.ORG - 15:13, Friday 18 April 2014 (11444)

I copied all the temporary blend fiters under:
/ligo/svncommon/SeiSVN/seimic/BSC-ISI/Common/Complementary_Filters_BSC_ISI/aLIGO/Temporary_Versions/

Now the regular blend filter folder only contains the ones to be used:
/ligo/svncommon/SeiSVN/seimic/BSC-ISI/Common/Complementary_Filters_BSC_ISI/aLIGO/

  • Start_Blend.mat
  • TBetter.mat
  • TCRappy.mat
H1 SEI
arnaud.pele@LIGO.ORG - posted 09:38, Friday 18 April 2014 - last comment - 17:05, Friday 18 April 2014(11432)
HEPI Position Control or fluid flow appears to NOT contribute to ETMY ~10hz Resonance

Arnaud & Hugh

We quickly looked at this.  We didn't expect an effect but HEPI PS control runs at ~10hz (Epics) and we could check so we did.  The attached looks at the Pier top horizontals over the ground STS2.  All the horizontsl HEPI signals looked the same wrt both horizontals of the STS2s.  First Ref is ISI OFF, HEPI position loop ON, Second Ref is ISI OFF, HEPI Position Loop OFF, current trace is with the fluid flow zeroed.  No affect evident.

Images attached to this report
Comments related to this report
arnaud.pele@LIGO.ORG - 17:05, Friday 18 April 2014 (11453)

I guess I was wrong. After taking a closer look at it, closing the position loops on HEPI is actually amplifying the motion at 10Hz, by a factor of ~3. References are with position loop off.

Images attached to this comment
Displaying reports 72941-72960 of 84064.Go to page Start 3644 3645 3646 3647 3648 3649 3650 3651 3652 End