gerardo.moreno@LIGO.ORG - posted 15:49, Friday 11 April 2014 - last comment - 16:50, Friday 11 April 2014(11291)
ALS New Shutter

(Joseph D., John W., Justin B., Sheila D.,  and Gerardo M.)

Shutter installation finished today.

The viewport will need to be pulled sometime later for a close inspection and or possible replacement.

Images attached to this report
Comments related to this report
gerardo.moreno@LIGO.ORG - 16:50, Friday 11 April 2014 (11300)

I opened GV7 at 2 pm.

X1 DTS
james.batch@LIGO.ORG - posted 15:16, Friday 11 April 2014 (11290)
Rebooted x1boot
I moved x1boot to a different location in the rack, requiring a power down and restart.  An fsck was run on startup, delaying the boot process by over 30 minutes.
LHO General
patrick.thomas@LIGO.ORG - posted 12:58, Friday 11 April 2014 (11288)
h0epics2 updated and rebooted, IOC for weather station at end Y started
Cyrus R., Richard M., Patrick T.

h0epics2 runs the fmcs, tidal and weather IOCs.

Although the weather and fmcs IOCs appeared to be running fine (I did not check tidal), h0epics2 was nearly unresponsive to log in attempts. When I restarted it, it would not mount /ligo. Cyrus noted that it was trying to mount h2boot, which no longer exists. Fixing this allowed it to mount /ligo. Cyrus took the opportunity to apply the OS updates. Once that was done I restarted the h0fmcs, h0tidal and h0weathercs IOCs. I also started the h0weatherey IOC, which was the reason I had tried to log in to begin with.
H1 TCS
david.hosken@LIGO.ORG - posted 12:56, Friday 11 April 2014 (11287)
TCSY cooling hose damage
Greg / DavidH
At ~0930 we were notified that a cut to one of the TCSY cooling hoses had been observed, and despite there being no leaks, it was decided to remove the affected length of hose near the table enclosure feed-through (cut out). No sharp edges were noticed on this feed-through, however as a preventative measure some clean room tape was applied around this cut out and then also around the two hoses before reconnecting them up. The chiller was operated and no leaks were observed.
The cooling hoses to TCSX were also inspected and no damaged was found. However, as a preventative measure, clean room tape was also applied around these hoses where they passed through the feed-through. It was decided to not disconnect these hoses (to apply tape around the enclosure feed-through) since no damage was observed and disconnection within the enclosure could introduce water leaks.
See attached photos. 
Images attached to this report
LHO VE
kyle.ryan@LIGO.ORG - posted 11:57, Friday 11 April 2014 (11286)
(~1000 hrs. Y-end) -> Dumped GV18's gate annulus volume into pump cart -> Valved-out MTP and annulus pump carts -> Opened GV18
At behest of others -> GV18 will be closed later today
H1 SEI
stefan.ballmer@LIGO.ORG - posted 11:04, Friday 11 April 2014 (11285)
HEPI L4C wd reset
To avoid HEPI tripping on L4Cs, I made a simple script to raise the WD value to 99999 on HAM2 HAM3 ETMX ETMY ITMX ITMY. This task can be automated daily by running crontab on a script machine but this needs a SEI approval !
Script is called ResetL4cwd.sh and lives in /ligo/svncommon/SeiSVN/seismic/BSC-ISI/H1/Common/Misc
H1 CDS (DAQ)
david.barker@LIGO.ORG - posted 08:31, Friday 11 April 2014 (11283)
CDS model and DAQ restart report, Thursday 10th April 2014

no restarts reported.

LHO VE (VE)
rainer.weiss@LIGO.ORG - posted 21:48, Thursday 10 April 2014 (11281)
Pump down of the yend
The pressure is dropping as 1/t^0.87. There is still water diffusing out of
materials. It should be safe to open the gate valve to the trap and the beamtube
for periods of hours. If the pressure drops below 2 x 10^-8 torr when the chamber
is exposed to the trap and the beamtube, the gate valve can be left open permanently.
The plot shows the current trend.
Non-image files attached to this report
H1 ISC
keita.kawabe@LIGO.ORG - posted 19:31, Thursday 10 April 2014 (11280)
Checking the clipping in EY TMS green QPD path

Wanted to check the clipping in Green path at EY. Since EY doesn't have WFS ready, the only thing I can do is to see the QPDs, which is not that interesting, but I asked EX people to do this kind of thing for EX using QPDs and WFSs to check the full green REFL path.

What was done for EY:

If there's a clipping there's a linear coupling to NSUM, but it's difficult to get a sense of how large the excitation is. To get that sense, we look at QPD PIT signal itself. Apparently, PIT signal depends on where the QPD is placed (e.g. QPDB is mostly insensitive to PZT1 while QPDA is less sensitive to PZT2 than QPDB is, and this is by design), so we need to pick a good QPD for a given PZT. I didn't mix QPDs as using one QPD looked good enough.

Anyway, this is only with QPDs and thus things are simple, you need to look at QPDB for PZT2 (left top, blue) and QPDA for PZT1 (right top, red). 50dB difference between the beam displacement on the QPD and the NSUM signal. This might be some small clipping or inbalance in the QE or in the transimpedance or maybe some coupling via cable, but the point is, this looks good.

As I wrote above, you should be able to do this using WFS and check the full green REFL path.

Images attached to this report
H1 AOS
keita.kawabe@LIGO.ORG - posted 17:54, Thursday 10 April 2014 (11279)
ITMY video

In preparation for peeking down the Y arm tomorrow, I checked the video hardware to monitor ITMY (as it turned out that we don't have IY baffle diodes).

Both the spool camera and the BSC camera cans were there and the cables were still coming out of the cans. I asked Filiberto to find if the cables are still routed to the control room.

H1 ISC
keita.kawabe@LIGO.ORG - posted 17:49, Thursday 10 April 2014 (11278)
ICSTEY fiber path realigned

Something must have happened while I was working on the WFS path, and when I looked at the beat note before returning to the corner station the beat note was -40dbm. (Was -10dbm before).

Changing temperature had almost no effect. Measured the IR power from Prometheus and the fiber, both were good.

Started realigning the path and eventually got back to -16dbm at about 40MHz. Still big, though not as big as before.

Now the laser temperature is 35.6 degree C (was 33.7 before), though to me both of these temperature look perfectly fine.

H1 ISC
gerardo.moreno@LIGO.ORG - posted 17:26, Thursday 10 April 2014 (11276)
ALS Shutter Replacement

(Joseph D., John W., Justin B., Sheila D.,  and Gerardo M.)

Attempted to install new ALS shutter, but as soon as we started we found 3 scratches on the viewport (inside side), see photo, John was consulted and the decision was to abort the rest of process, first contact was not applied to viewport, and the rest of the components were staged to finish work tomorrow.  GV7 will remain soft closed until then.

Images attached to this report
H1 SEI
sheila.dwyer@LIGO.ORG - posted 16:51, Thursday 10 April 2014 (11274)
ITMY trips

ITMY tripped twice while we were switching blends, guardian brought it back fine

H1 CDS (PEM)
david.barker@LIGO.ORG - posted 16:33, Thursday 10 April 2014 (11273)
overview pem medm for front end fast channels

I have built overview MEDM screens showing the EPICS monitor of all PEM fast channels. To add these for CS, EX and EY to the sitemap I had to give PEM two related pull downs. All weather screens are in the right pull down, dust and others in the left.

Currently the BLRMS signals are missing because they have different name suffixes, I'm in the process of adding them.

LHO General
gerardo.moreno@LIGO.ORG - posted 16:20, Thursday 10 April 2014 - last comment - 17:00, Thursday 10 April 2014(11272)
Operator Summary

- 9:00 am, Apollo to LVEA, prep for beer garden transformation.
- 9:15 am, David to LVEA, check on TCS cable short.---> done by 10:05 am.
- 9:30 am, Aaron to LVEA, cable run for photodiode amplifier.
- 9:41 am, Betsy and Travis to Y-End, SUS hardware retrieval.
- 10:14 am, Pablo to LVEA, hunt for a spare VCO.
- 11:30 am, Robert and guests to LVEA beer garden, installation of microphone.
- 1:00 pm, Kyle to Y-arm, open gate valves, not GV18.
- 1:10 pm, Karen to Y-End, cleaning.
- 1:10 pm, Corey and Cyrus to YBM, gigE camera testing.---> done by 1:35 pm.
- 2:00 pm, Apollo crew to LVEA, setup to move items around beer garden, remove stairs, support platforms, etc.
- 2:54 pm, Sheila and Justin to H1PSL laser enclosure, block ALS path for change of shutter.
- 3:15 pm, Joe and Gerardo to LVEA, remove and replace ALS path shutter.
- 3:24 pm, David and Greg to LVEA, TCS plumbing work.
- 3:49 pm, LVEA transitioning to laser safe.

Comments related to this report
gerardo.moreno@LIGO.ORG - 17:00, Thursday 10 April 2014 (11275)

GV7 was soft closed for ALS shutter work.

H1 AOS
daniel.sigg@LIGO.ORG - posted 12:01, Thursday 10 April 2014 - last comment - 07:51, Friday 11 April 2014(11269)
ITMY AOS baffle PD

(Filiberto, Aaron, Thomas, Daniel)

We installed the baffle PD amplifiers for ITMY. This is a new double chassis, so we replaced the old single unit. This should also fix channel 4 for the ITMX diodes. Previously, channel 4 was connected to channel 3, but now is back on channel 4. The TwinCAT system has been reconfigured to recognize the new channels.

Comments related to this report
daniel.sigg@LIGO.ORG - 07:51, Friday 11 April 2014 (11282)

Activated the ETMY baffled diode amplifier in TwinCAT.

H1 TCS
david.hosken@LIGO.ORG - posted 10:26, Thursday 10 April 2014 - last comment - 17:29, Thursday 10 April 2014(11262)
TCS status
Dave H, Alastair, Thomas, Greg

Quick summary of progress:

TCSX:
Laser was operated for a few hours on Monday with an output power of ~58.5W. Optics have been mounted and placed in position on the table. This table is now ready for alignment.

TCSY:
Optics/mounts have been staged, and are ready for table installation. Cabling is almost complete. Attempts were made on Wednesday to operate the laser/test the output power, however this was unable to be performed due to a fault with the paddlewheel flow meter (amongst other interlock/laser controller issues that are still to be tracked down). Some additional cabling is still to be installed. 

TCSX/Y periscopes have been partially assembled, still to track down one last component. Socket head cap screws with lower profile heads have been ordered, as it was observed that the cap screws for the periscope base sit proud. 
Comments related to this report
david.hosken@LIGO.ORG - 11:17, Thursday 10 April 2014 (11264)
TCSY paddle wheel flow sensor power checked and settings confirmed. Still unable to display water flow value. Will need to remove from system and check operation on the bench and/or replace.
david.hosken@LIGO.ORG - 17:29, Thursday 10 April 2014 (11277)
DavidH/Greg : Paddle wheel flow sensor removed, tested and was found to be working as expected. Reinstalled/reseated and now appears to be working correctly. As per installation instructions, for this install no teflon tape was used... previously used tape was removed.
H1 SEI (SEI)
hugo.paris@LIGO.ORG - posted 13:21, Wednesday 09 April 2014 - last comment - 14:50, Friday 11 April 2014(11240)
04/01/14 Chile Earthqake Seismic Study

A magnitude 8 earthquake coming from Chile tripped all the BSC-ISIs on 04/01/14. Sheila's wd plots show that the ISIs tripped on the actuator watchdogs. We suspected that the servo loops were trying to compensate for the common mode seen by the BSC-ISIs at both ends of the arms, thus saturating the actuators. We studied the ground motion recorded by the ground STS at the corner station (BS-STS) and the ground T240 installed at EX (EX-T240) at the GPS time provided by Sheila, in order to find out.

On the attached document:

 

We could considerably reduce the amount of signal sent to the BSC-ISI actuators during a major earthquake (factor as big as 6), and thus reduce the risk of saturating the actuators, by removing the common mode from the signal we feed to the servo loops of the BSC-ISIs.

 

Data, plots and scripts are commited to the seismic SVN:
/ligo/svncommon/SeiSVN/seismic/Common/Data/2014_04_01__Chile_Earthquake_Data/

 

Note 1: X and Y had to be swapped on EX data, and a minus sign was also added to the new x-axis EX data. It is likely that EX T240 is mis-oriented.
Note 2: The calibration of EX-T240 was still the one that JeffK made, at the time we looked at. RichM updated it since.

Non-image files attached to this report
Comments related to this report
hugo.paris@LIGO.ORG - 14:50, Friday 11 April 2014 (11289)

Units were updated.

Plots and script were commited to the svn.

Non-image files attached to this comment
H1 PSL (DetChar, IOO)
laura.nuttall@LIGO.ORG - posted 07:22, Tuesday 08 April 2014 - last comment - 08:33, Friday 11 April 2014(11212)
PSL and IMC ODC look odd
Since Saturday the ODC for the PSL and (obviously) IMC have looked a little odd. They both keeping reporting very short, quick times when both the systems are not 'good'. These happen throughout the day as you can see by the two attached plots which show yesterday's activities (you can see more of these plots on the summary pages - https://ldas-jobs.ligo-wa.caltech.edu/~detchar/summary/). Just wanted to check you knew about this and if so is this nothing to worry about? Thanks! 
Images attached to this report
Comments related to this report
stefan.ballmer@LIGO.ORG - 08:33, Friday 11 April 2014 (11284)
This was another iteration of the ISS actuation running into its range limit.