Work Permit 4509, update windows virtual machine for dust monitors
Throughout the day as well
LASER IS ON - Output Power = 28.3 W - Watchdog is active - System status is good PMC - Locked for 14 hours - Refl Power = 1.2 W, Trans Power = 10.1 W FSS - Ref Cav locked for 14 hours - Alignment looks slightly off but still resonant, PD threshold = .812 Volts ISS - 13.2% diffracted power - Saturated 14 hours ago.
As a reminder the aLOG is down for maintenance today starting at 12:15pm pacific. Please save your log entries as drafts or post them to the log book prior to this time, or they will be lost.
The maintenance is completed.
model restarts logged for Mon 17/Mar/2014
2014_03_17 23:20 h1fw1
unexpected restart of h1fw1, it has gone slightly unstable in the past week.
This is the only restart since last Thursday.
TMS Work (Corey, Jax, Keita, Margot)
Apollo roughly positioned the ISCT-EY Table (via floor markings).
Chamber Floor was first cleaned upon entry for work (did not do an exit floor wipe). Margot then entered the chamber to remove First Contact from inside surface of pair of TMS Viewports (then went out and removed First Contact off outer surfaces). She mentioned "finger prints" on the outside surface of one of the TMS viewports; Margot will document in the DCC.
By eye, we checked position of the table, we ended up pushing the table about 3" west. We then attached ducting between the chamber and the table. Then we went in to check our line of sight from the TMS Table to the Table Periscope. This required us to move the GREEN periscope an inch east, and also the top periscope mirror down 4-6". At this point the laser wasn't quite making it down the ductThis is about where we ended things last evening.
Dust Monitor Check Of Purge Air For BSC10 (Corey, John, Keita)
John whether there was dust coming from the purge air. So I, with handheld Dust Monitor in hand, crawled under the ACB, and took a few measurements from the Dust Monitor (which was running continuously). I took measurements at four spots above the input of the purge air. At the highest point, I had readings which would hover between 1500-2500 counts of 0.5um particles. At the lowest point (with sensor of Dust Monitor right at the input), the 0.5um counts could be kept at basically 0-counts (with flashes of a few hundred possibly. So, it would seem the purge air is relatively clean.
These 2 statements seem contradictory:
"At the highest point, I had readings which would hover between 1500-2500 counts of 0.5um particles. [At the lowest point ...] So, it would seem the purge air is relatively clean."
Maybe can John elaborate at where he thinks the high counts are "coming from" if not the purge? Is it just that the air is turbulent in chamber and stirring up the 1500-2500 counts already in the chamber?
Corey saw high background levels in the beam manifold but was able to drive the particle counts to zero by moving the detector close to the purge port at the floor of the beam manifold. I walked around the VEA sampling and found low levels throughout. Counts inside cleanrooms were close to or equal to zero except at the open BSC door. There was activity here as well as equipment staged. Corey was inside and Keita was outside at the BSC entrance. The overhead work platform reduces the effectiveness of the clean room in this location. Inside, the arm cavity baffle obstructs access to the beam manifold so any work in the beam manifold requires a person to laydown and slide under the baffle. This may very well abrade clothing. I recommend we establish a horzontal clean flow as we have while working in HAM chambers.
A reminder that the purge air can only provide 25--50 cfm of air flow into the chamber. In a 6 foot diameter tube (beam manifold) this translates to air velocities of only 0.6 to 1.2 feet per MINUTE. Think how far you walk in a minute.
My impression is we have a reservoir of particulate in the vacuum chamber from the series of operations which have taken place - for example there have been two cartridge installs and one removal. Also this cartridge is an early assembly - probably assembled prior to some of the "in process" cleaning steps we have adopted.
Yes, I should elaborate a little (was quickly entering alog during Morning Meeting). So we did measure counts while I was in BSC10. And seemed like we had steading counts in the several thousands [for 0.5um counts with continuous sampling]. When I took measurements along the Purge Air plume, I would get up to 2500 at the most at the top of the plume (6' high). As I went closer and closer down to the Purge air inlet, the counts started to drop. And it was zero right at the inlet.
So the picture looked as though we have a baseline of particles floating in the chamber. And in the turbulent air above the Purge Air inlet the counts waiver a bit, but counts decrease the closer you are to the inlet. So above the purge we have particles moving around more (vs further away from purge these particles are more "statically" floating...perhaps they are more on the floor when someone like me isn't shuffling them into the air).
Basically we have particles all over the surfaces in the chamber/tube. They may be gently floating around or resting on the floor. They get rustled around when we work in-chamber & also get blown around and away from the Purge Air inlet. We need to remove these particles...which I know is obvious and daunting.
We're going to coninue wiping these particles on the floor toward door, but not sure what that does. Hopefully, particles get attached to our wet wipes, but I wonder if particles just get pushed to the edge of the floor and then fall over the edge of the temporary floor and then rain down to the bottom of the chamber. Sad sad.
Are these raw or normalized counts?
J. Kissel, A. Staley The H1 HAM2 ISI consistently trips using the guardian on the GS13s, right as the X, Y, Z, RZ isolation filters begin to turn on, just after the RX and RY alignment biases are slewed. I had thought it might have been because I found the GS13s in high gain mode (why? because of a restart of the guardian process maybe?), but I switched them back to low gain mode (with dewhitening ON) and things still trip because we're trying to engage horizontal GS13s that that just been yanked around in tilt. I confess, we *didn't* reset the CPS offsets and store them in the target before getting started and I don't know the difference between the equilibrium state and the current target, nor do I know the last time they were reset and stored, so it might be fine if I just do that. I'm surprised to see the RX and RY alignment biases being ramped in between turning on each of the isolation filters already. We have certainly discussed doing this, but I would have expected more testing to iron out these bugs. Jamie's update aLOG doesn't mention anything about it, other than nodes have been restarted with some minor bug fixes. For the evening, I left the requested state in damping, and brought up the isolation loops using the commands script. That works because it doesn't play with the biases until the isolation filters are completely engaged. Also note, that if you manual put the ISI into the HIGH ISOLATED state, and then switch the request to such, it turns the isolation loops off and starts from scratch. Not desirable, but may be tough to code up / or insure that you're actually in high-isolated. I post to examples of the GS13 trip, but it's clear what's happening, as I describe above.
(Alexa, Jax)
The PZTs on ISCTEY are now working. We had found that the AA chassis hooked up to the DAC channels was turned off. The PZTs move as expected. When we run the servo we might want to be aware of the sign convention (it seems to obey positive counts in pitch moves the beam down).
NOTE: Anti-Aliasing chassis in slot 9 of rack ISC-C1 has no power cable. Filiberto help!
Output power is 28.4 W (should be ~30 W) Watchdog is active Only warning in SYSSTAT.adl is 'VB program online'. PMC is NOT locked FSS is NOT locked ISS is NOT locked
The guardian and cdsutils (ezca) libraries have been upgraded:
Mostly just bug fixes and some performance improvements.
All SUS and ISI guardian nodes were restarted. ISC nodes were not restarted but should be restarted soon.
David Hosken, Thomas Vo, Greg Grabeel Ran the chiller pumps starting from around 2pm until 5pm. Only one small leak on the loop back hose at BSC 3 was found. BSC 1 had a flow rate of 7 lpm when running in a partial bypass pressure of 24 psi. BSC 3 had a flow rate of 7.5 lpm when running at a partial bypass pressure of 21 psi. Both were running at 20* C and had a very minimal fluid level drop. Hopefully a longer test tomorrow will yield the same positive results. Good job Apollo.
dust monitors 1 and 15 going in and out of communication prep work for opening HAM5 doors 10:02 - 11:02 Jeff B. installing dust monitor 4 in clean room over LVEA test stand 10:19 - 11:23 Filiberto checking ESD cable connections at end Y 10:47 Betsy, Travis staging equipment in LVEA, opening rollup door 11:00 BS ISI left with Start blend filters (Patrick, Corey, Jeff K.) 11:03 Andres working on SR3 11:05 - 13:11 Gerardo working on OFI in H2 PSL enclosure (no laser) 12:58 - 15:01 Karen cleaning at end Y 13:16 Greg, David H., Thomas going to test TCS chiller lines in LVEA 13:46 Cris to end X VEA to get Acetone 14:16 Gerardo working on OFI in H2 PSL enclosure (no laser) 15:17 Kyle done testing valve in of temporary RGA at Y1 16:20 end Y going to laser hazard
(Craig, Doug, Travis, Jason) We set the camera pointing path by mimicking the camera view using a laser pointer. An existing fixture was modified and worked well and mounted up well. We aligned the north side camera view without much issue. The south side required a bit more tweaking of the internal steering mirrors. The procedure we used involved retro-reflecting a laser pointer through a 1/8" pin hole centered on the viewport. We steered the beam with a couple of turning optics on the fixture. We then propagated the beam through 2 steering optics permanently mounted to the periscope inside of the beam tube and then onto the P-cal target mounted in front of ETMy core optic. All P-cal hardware is removed from the vacuum chamber and repackage for storage.
The ETMX decoupling filters for top mass drive to pitch motion at the test mass are now installed in the appropriate L2P bank (split in two filters in FM1 and FM2), and using a gain of -1 (cf 2nd attached screenshot L2P_medm)
It reduces the pitch motion from length drive by a factor of ~7 @ .44Hz and ~5 @ 1Hz (cf first screenshot ETMX_L2P_testing), comparing the L2P transfer function with/without the filter.
Method :
1) Measured L2P and P2P transfer functions using following templates
/ligo/svncommon/SusSVN/sus/trunk/QUAD/H1/ETMX/SAGM0/Data/2014-03-17_H1SUSETMX_M0_LtoPY_WhiteNoise_0p1to10Hz.xml
/ligo/svncommon/SusSVN/sus/trunk/QUAD/H1/ETMX/SAGM0/Data/2014-03-03_H1SUSETMX_M0_PtoPY_WhiteNoise_0p1to10Hz.xml
2) Compared the measurement with model, fitted the measurements, inverted P2P and calculated L2P/P2P using the script LP_decoupling.m located in
/ligo/svncommon/SusSVN/sus/trunk/QUAD/H1/ETMX/SAGM0/Scripts
The fitting and inverting process is summarized in the attached pdf.
Note : There's a factor of 11 between fit and model at DC
J. Kissel We're really getting pummelled by ground motion, especially the past few days. I attach plots of the band-limited RMS in the Z direction of PEM ground inertial sensors in the corner station and the X end station over the past 48 hours. We've been hit by earthquakes (in the 30-100 [mHz] band), high-micro seism from windstorms and spring ocean activity (in the 100-300 [mHz] band), and gusts of wind and anthropogenic noise (in the 1-3 and 3-10 [Hz] bands). I think this is an excellent representation of why we've had so much trouble trying to find a configuration of the isolation systems that "just works" -- the characteristics of the input motion radically change constantly on a ~3-hour timescale. Not to mention there are times (like in the middle of the plot, 2014-03-16 21:50 UTC) where the earth is just down right angry with all three bad things at the same time. I apologize for the ambiguity in calibration, I have an email out to Robert asking the proper calibration into physical units. The FOMs with these channels on the wall suggest that the channels are calibrated into "[decaum/s]" in the frames (which I think is 10 * 1e-6 [m/s]) but with no calibrations in the DMT template (and none on the data viewer trace, obviously), I get different numerical values. pem.ligo.org suggests that both the corner-station and endx should be 0.0076e-6 [m/s]. I think whatever units they are, they're at least self-consistent. I'll take spectra at choice times to gather the diversity; stay tuned.
Here're the promised, associated spectra. I attach an annotated version of the BLRMS too, with vertical lines demarcating the UTC time in the same colors as the traces on the spectra. As indicated by the legend, I chose representative times that reflected the variety of ground motion: 2014-03-16 15:45 UTC - High micro-seism 2014-03-16 18:05 UTC - High micro-seism + Gusty Wind 2014-03-16 21:45 UTC - High micro-seism + Large Earthquake, in Chile + Gusty Wind 2014-03-17 05:50 UTC - Medium micro-seism + Cluster of Small Earthquakes (Chile, Again in Chile, Philippines, Puerto Rico, and Mexico, at magnitudes 6.2, 5.0, 5.1, 3.0, and 2.8 respectively). 2014-03-17 18:45 UTC - Low micro-seism + Gusty Wind Notes: - While we don't necessarily expect to be able to stay up during large earthquakes, it's good to see a sort of upper bound, and the contrasting color of the ground motion as it fills in the 30 to 100 [mHz] band. - It's interesting to see that during periods of high microseism, the peak at 55 [mHz] seems to be present regardless of whether the winds are gusting or not (comparing BLUE and RED) . - Further, there exists times (i.e. MAGENTA) where there is lots of gusting winds, but the microseism is relatively low. - Most importantly we see that ground is sort of oscillating between requiring more isolation in the 30 to 100 [mHz] band and in the 1 to 10 [Hz] band. - The variations in the 30 to 100 [mHz] band can be as much as a factor of 100 during earthquakes, but not too much change between windy and not windy, maybe at most a factor 5 in a small range between 40 and 80 [mHz]. - There's very little to no change in the region of the lowest SUS resonances between 0.2 and 0.6 [Hz] between all of these seismic bad times - Naturally, gusty wind times are the worst at high frequency, but again the variation is only a factor of 3 to 4. We should be able to ride this out. Let's see what the HEPI L4Cs say, maybe the gusts have an interesting affect playing with the pier flag poles.
J. Kissel Here're the HEPI L4Cs for each of the times described above. While they show the same sort of variety at the microseism and below (where they can sense the ground motion above their self-noise), the most interesting is how much more varied the tilt spectra are (in this case RY) in the 0.3 to 1 [Hz] band -- exactly where the translation degrees of freedom claim there's very little difference. And naturally the ITM reacts differently than the ETM, just to make things difficult. For ITMX, both high microseism conditions and gusty wind show elevated tilt in the 0.3-1 [Hz] band, by about a factor of 10. Only the during the medium microseism + small earthquakes did the L4C hit it's (tilt) noise floor. For ETMX, there's quite a variety, with gusty winds alone being the worst-case scenario. But the moral of the story is that, where translation degrees of freedom get tossed around by an order of magnitude between 0.03-0.3 [Hz] and 1-10 [Hz] during these excurisions, the tilt fills in the 0.3-1 [Hz] gap with its own order of magnitude variation, and as we know *both* tilt and translation of the table affects the optics just about equally. So -- if we want to operate the isolation systems during these 90th percentile times, we're gunna have a lot of automation and blend tailoring to do, but just increasing the blend frequency won't necessarily win. Further, when we *do* #movetheblendup, the green still can't handle the loss in performance.
The data for the above measurements can be found in the following templates: /ligo/svncommon/SeiSVN/seismic/BSC-ISI/H1/Common/Data/ 2014-03-16to17_GroundMotion_ASDs.xml 2014-03-16to17_HEPIPierMotion_ASDs.xml There's way to many curves for me to export, but all curves shown are stored as references so you can export them at your leisure and use them in any models. Ground Motion Pier Motion 2014-03-16 15:45 UTC Ref. 0-11 Ref. 0-23 2014-03-16 18:05 UTC Ref. 12-23 Ref. 24-47 2014-03-16 21:45 UTC Ref. 24-35 Ref. 48-71 2014-03-17 05:50 UTC Ref. 36-47 Ref. 72-95 2014-03-17 18:45 UTC Ref. 48-59 Ref. 96-119 All plots and templates are committed to the repository as of this entry.