Reports until 19:27, Thursday 06 February 2014
H1 AOS
keita.kawabe@LIGO.ORG - posted 19:27, Thursday 06 February 2014 (9903)
TMSY today

1.  Cabling.

QPD, picomotor and beam diverter were connected to the cables coming from the ISI. We spent an hour or so just to connect the green QPD cable (D1000568 s/nS1104468), as the male pins of DB25 don't align well with the female pins and the male pins are sort of deformed. This is a known issue with this specific connector, and hopefully this is the last time we have to do this.

2. Hartman reference path.

Two Siskiyou mounts and optics for Hartman reference path were removed from the assembly, as these are not in the production units. However, periscope for Hartman reference path stays as removing it might change the weight too much.

3. Black glass thing.

Attempted to install 5 black glass beam dumps (https://services.ligo-wa.caltech.edu/integrationissues/show_bug.cgi?id=5), but couldn't. The issue is that the head of the tensioner screw on the Siskiyou mount that is holding the picomotors is slightly sticking out from the mirror mount surface, and this interferes with the beam dump holder (https://dcc.ligo.org/LIGO-D1002701).

For newer production unit we remove one washer under the screw head before assembling and the screw head doesn't stick out any more, but in this case we need to retrofit, and removing the screw to remove the washer means that the picomotors come out and the alignment would be ruined.

After some discussion with John Worden, he showed me how to mill using clean tools, and we milled slots for the beam dump holders such that the slot would accomodate the screw head.

Tomorrow morning I'll give them to C/B people so they could be cleaned in untra sonic bath and then air baked. I hope that this can be done by the end of the day, without these things we cannot do initial alignment as 5 pieces of black glasses are heavy enough to change the table balance completely.

4. IAS target not found.

This is another thing that are necessary for  IAS to do their thing. Doug may have these, Corey couldn't find them in the EX lab.

H1 ISC
daniel.sigg@LIGO.ORG - posted 18:30, Thursday 06 February 2014 (9902)
Second order HOM locking

This morning the X-arm accidentally locked to what looked like a second order higher order mode of the ALS beam. The power of the transmitted light in arbitrary units was

Zero level 35 0
TEM00 845 810
2nd order HOM 150 115

This would mean about ~15% of the incident power is not mode matched to the cavity.

H1 SUS (COC)
margot.phelps@LIGO.ORG - posted 15:53, Thursday 06 February 2014 (9900)
Updates from the LHO Bonding Lab this week
(Gerardo and Margot)
ITM03 and ITM11 have both ears bonded on, and are back in their cake tins for curing.
ITM03 S1 also had its fc pulled, and coating inspected as seen in T1400043. A “ thick balanced layer” was re-applied to face, leaving a small part at 12 o’clock position off for welding alignment. 
Pulled PEN-ETM08 out and staged, will get at least one ear onto it tomorrow morning (friday). 
CP05: Fiducial measurement staged and completed (had to get granite table moved to bonding lab, and equipment set up etc.) Left CP05 in flipper under flow bench for getting its prisms on next week. Measurements are on the dcc under E1400054.  
LHO large optics inventory: Went through cabinets here, then updated nebula location and install vs spare status for CPs, ITMs, LHO PEN-ITMs, LHO PEN-ETMs, SRMs, SR2s, PRMs, and PR2s. 
H1 IOO
laura.nuttall@LIGO.ORG - posted 15:43, Thursday 06 February 2014 (9899)
ASD over the past week of IMC-F and IMC-X
Just for your information, from Jan 30th-Feb 6th the IMC has had a duty cycle of 81.5% (according to the ODC) and attached are the ASD of IMC-F and IMC-X for this period (i.e. all the good time in the past week). Plotted are the median ASD of this time period with the 5th and 95th percentile showing the shaded regions. As you can see the spectra look quite stable. 
Images attached to this report
H1 CDS
james.batch@LIGO.ORG - posted 15:08, Thursday 06 February 2014 (9897)
DTT icon on controls desktop reassigned to test version of DTT
I have changed the controls account desktop DTT icon to read DTT-debug, and have redirected it to start a test version of diaggui which should solve a critical bug that has generated complaints for the last few years.  The bug involves the inability for diaggui to properly restore Reference traces to the plot window when read from a .xml file.  This should show up on new logins of the control room computers running Ubuntu.

The command line invocation of diaggui still opens the non-test version.

Please use the desktop DTT-debug icon if you would like to test this.  Feedback is appreciated.  Once further testing is complete, a new version of the gds tools will be released.
H1 SEI
hugh.radkins@LIGO.ORG - posted 14:29, Thursday 06 February 2014 (9895)
ITMY ISI Matrices Updated--Target Positions Reset

Reloaded the Local to Cartesien Matrices to correct errors (per T1000388).

This changed the Location Monitor numbers mostly in sign but some minor magnitudes too. The X Y RX & RY values changed signs.  I reset the targets with the ISI off (and HEPI position loops on).  The Rz value changed by a couple urads.

Images attached to this report
H1 CDS
patrick.thomas@LIGO.ORG - posted 14:21, Thursday 06 February 2014 (9896)
Added Beckhoff channels back into Conlog
I added back the Beckhoff channels minus a new list of ones that appeared to be changing too quickly. This time the update rate appears reasonable. Conlog is now monitoring 97,308 channels (target_grep_channel_list_minus_fast_beckhoff.txt). The list of fast channels I removed is also attached (beckhoff_ro.txt).
Non-image files attached to this report
H1 General
patrick.thomas@LIGO.ORG - posted 13:05, Thursday 06 February 2014 (9894)
Richard, Arnaud to ETMX to troubleshoot ground loops


			
			
H1 SUS
jeffrey.bartlett@LIGO.ORG - posted 12:30, Thursday 06 February 2014 - last comment - 16:27, Thursday 06 February 2014(9892)
Pre-Glass Installation Measurements of H1-SR3
Jeff B & Andres R

   We moved the HLTS suspension SR3 into position to have the metal Bottom Mass replaced with the Glass Optic. We took height and blade tip breakoff measurements as a pre-installation base line. All measurements are within tolerances. 

Measurement Point            Target/Tolerance  	                         Measurement 
Top Blade Wire Breakoff       806.12mm	                                 804.93mm, 805.89mm 
Bottom of T-Block                 552.23mm	                                 552.60mm
Top of Intermediate Mass     461.63mm	                                 461.63mm
Lower Blade Wire Breakoff   608.84mm tip coplanar <0.5mm  607.75mm, 608.11mm, Coplanar = 0.36mm
Top of Bottom Mass              291.0mm +-1mm	                         291.17mm

   The next step is to center and adjust the OSEMs, and then run Phase 2A Transfer Functions.  
Comments related to this report
andres.ramirez@LIGO.ORG - 16:27, Thursday 06 February 2014 (9901)
The OSEMs have been re-centered and then retracted for taking the OLVs. A D1000234 quadruple cable needs to be attached before running the "PrettyOSEMgains" script.
H1 DAQ (CDS)
james.batch@LIGO.ORG - posted 12:25, Thursday 06 February 2014 (9893)
Restarted h1nds1 daqd
Corrected daqdrc file, restarted daqd on h1nds1.
H1 SEI (SEI)
richard.mittleman@LIGO.ORG - posted 12:18, Thursday 06 February 2014 (9891)
Sensor Correction for BS-BSC-ISI

  In preparation for installing sensor correction I took a ground to platform transfer function to see what kind of coherence we have, short answer is lots from 0,1 to a few hertz

 

Images attached to this report
Logbook Admin General
jonathan.hanks@LIGO.ORG - posted 11:40, Thursday 06 February 2014 - last comment - 12:03, Friday 07 February 2014(9890)
Scheduled downtime Friday 7 Feb 2014 noon Pacific
The aLOG will be down for maintenance tomorrow at noon (pacific time).

Please post or save your log entries before the maintenance.
Comments related to this report
jonathan.hanks@LIGO.ORG - 10:05, Friday 07 February 2014 (9905)
The downtime is being moved earlier in the day to 11:30am pacific.
jonathan.hanks@LIGO.ORG - 12:03, Friday 07 February 2014 (9915)
The work is completed
LHO General
patrick.thomas@LIGO.ORG - posted 11:35, Thursday 06 February 2014 (9889)
Mitchel out of LVEA west bay


			
			
H1 CDS
patrick.thomas@LIGO.ORG - posted 10:21, Thursday 06 February 2014 (9887)
updated alarm handler
I commented out the DC watchdog components in /opt/rtcds/userapps/release/cds/h1/alarmfiles/h1cds_iop_sus_watchdog_b123.alhConfig.
H1 General
patrick.thomas@LIGO.ORG - posted 10:05, Thursday 06 February 2014 - last comment - 11:23, Thursday 06 February 2014(9886)
Jeff B. working on test stand by HAM4,5


			
			
Comments related to this report
patrick.thomas@LIGO.ORG - 11:23, Thursday 06 February 2014 (9888)
Done.
H1 General
patrick.thomas@LIGO.ORG - posted 10:03, Thursday 06 February 2014 (9885)
Corey to end X, end Y
Getting alignment targets from end X and installing them on TMS at end Y.
H1 DAQ (CDS)
james.batch@LIGO.ORG - posted 09:55, Thursday 06 February 2014 (9884)
Restarted h1fw1 and h1nds1 daqd process
Frame writer 1 daqd and nds1 daqd were restarted to read new daqdrc files to allow writing of raw minute files in the proper place, following moving of old files to a different file system.  
H1 IOO (IOO)
paul.fulda@LIGO.ORG - posted 23:43, Wednesday 05 February 2014 - last comment - 16:15, Friday 07 February 2014(9870)
IMC mirror alignment offset calibration using transmitted power drop

I finally got a script working to step the alignment offsets on the IMC mirrors and record the transmitted power drop with MC2trans and IM4trans QPDs. 

The idea behind this was to compare the quadratic function for power drop with misalignment with the theoretical function, giving us a means of accurately calibrating the alignment offsets.

The reason I'm interested in calibrating these offsets accurately is for beam jitter measurements using the coupling from jitter to RIN in transmission of a misaligned IMC [see e.g. LHO aLOG entry 8190]. The coupling factor is determined by the slope of the quadratic function, so we can't calibrate jitter measurements made in this way any better than we can calibrate the DC alignment offset.

The first attached plot shows the normalized transmitted power obtained for each individual mirror DOF, from both IM4trans QPD and MC2trans QPD, over "intended" alignment offset. Also included is a plot of the normalized transmitted power from a Finesse model of the IMC over "real" misalignment offset. From these plots we can see that in general the alignment offsets actually applied to the MC mirrors are larger than the intended alignment offsets. However, the measured data is not always symmetric (especially for IM4). This could be due to clipping at the QPDs. The centering on IM4trans is not as good as the centering on MC2trans, so I would be more confident in the numbers from MC2trans.

I fitted a quadratic function P=A(x-h)^2+k to each of the curves. The calibration is then done by scaling the alignment offsets applied to the actual suspensions by sqrt(Amodel/Adata). The second attached plot shows each DOF again, but this time with the x-axis scaled for the measured data to fit the model. I used the scaling factors calculated from MC2trans data since the centering on this QPD was better. For the most part I'd say the data matches the model well after this scaling.

These scaling factors are:

DOF Scaling factor
MC1 Pitch 0.7043
MC1 Yaw 0.8223
MC2 Pitch 0.8572
MC2 Yaw 0.8326
MC3 Pitch 0.7823
MC3 Yaw 0.8588

I would propose to include these scaling factors in the calibration of the MC mirror offsets.

The script can be run again at any time to check for any possible changes in e.g. the OSEM coil driver gains over time. It might be beneficial to take more data points at some point too, but the script takes 15mins or so to run as it is (mainly due to the time given for optics to settle between changes of offset). Another improvement would be to step MC1 and MC3 pitch over a larger range, since the transmitted power is actually fairly insensitive to these DOFs. Both these things can be edited in the top few lines of the script.

In case anyone is interested in running this script in future, it is located at opt/rtcds/userapps/release/ioo/h1/scripts/imc/pfulda/IMC_align_calibrate.py

Be sure to run the mcWFSrelieve script located in opt/rtcds/userapps/release/ioo/h1/scripts/imc/ first though!

I attach the analysis scripts here too, including the measured data, Finesse model and results, and other functions used.

Non-image files attached to this report
Comments related to this report
paul.fulda@LIGO.ORG - 20:07, Thursday 06 February 2014 (9904)

In preparation for beam jitter measurements, I applied these calculated gains to the MC mirror M1 OPTICALIGN filter banks. Rather than just edit the gain directly, I made a new filter in each DOF's filter bank with the calculated gain. These filters are all called "alog9870" to point anyone towards the above entry for explanation. I then calculated the required new input offset values to retain the current alignment, and adjusted these while switching the filters on. The IMC is still aligned, but now the alignment offsets are calibrated to um using the data gathered from the IMC power drop measurement.

paul.fulda@LIGO.ORG - 15:12, Friday 07 February 2014 (9919)

Last night I had a bit of time to run the script again for a more detailed measurement, with 21 alignment steps, waiting 15 seconds for alignment to stabilize between each, and also averaging PD data for longer than previously. I also increased the misalignment range from ±30urad to ±50urad for MC1 and MC3 pitch.

Since the alignment offsets are now calibrated based on the previous measurement, I was curious to see if the model now fits well to the new data without the step of adjusting the x-axis.

The attached plot shows the new measured data and the model, without any adjustment of x-axis scaling. I think they all agree pretty well, though the one thing that concerns me slightly is the apparent offset in MC2 pitch. Is it possible there is an offset somewhere in the WFS loop that causes this? If so, maybe we could try adjusting this to maximize transmitted power / minimize reflected power.

Non-image files attached to this comment
paul.fulda@LIGO.ORG - 16:15, Friday 07 February 2014 (9922)

Just for completeness. the new MC opticalign offsets with this calibration included are:

DOF Old offset New offset
MC1 P 883.3 1254.2
MC1 Y -1945.7 -2366.2
MC2 P 470.4 548.8
MC2 Y 257.2 308.9
MC3 P -430.6 -550.4
MC3 Y -2119 -2467
Displaying reports 74261-74280 of 83866.Go to page Start 3710 3711 3712 3713 3714 3715 3716 3717 3718 End